Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹8.5 L
EMD Value
₹8,500
Closing Date
15 Jan 2026, 5:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COMMISSIONER OF UJJAIN MUNICIPAL CORPORATION
CHATRAPATI SHIVAJI BHAWAN, AGAR ROAD UJJAIN
CONSTRUCTION OF SABHA MANDAP NEAR TEKARESHWAR TEMPLE IN JILA PANCHAYAT UJJAIN PREMISES LOCATED IN WARD NO. 52
2025_UAD_466759_2
243/ZONE4/E-TENDER/2025
Open Tender
Civil Works - Buildings
Percentage
60 days
IN JILA PANCHAYAT UJJAIN PREMISES LOCATED IN WARD
PLEASE REFER TENDER DOCUMENT
4 documents required · 4 mandatory
₹2,000
₹8,500
1 Jan 2026
1 Jan 2026
16 Jan 2026
1 Jan 2026
15 Jan 2026
1 Jan 2026
ALL KINDS OF SOIL
CRUSHER STONE DUST
CEMENT CONCRETE GRADE M-10 (NOMINAL MIX) WITH 40 MM MAXIMUM SIZE OF STONE AGGREGATE
THERMO-MECHANICALLY TREATED BARS. (FE 500 D OR MORE)
"FOUNDATIONS, FOOTINGS, BASES OF COLUMNS, ETC. FOR MASS CONCRETE."
CEMENT CONCRETE GRADE M-20 (NOMINAL MIX) WITH 20 MM MAXIMUM SIZE OF STONE AGGREGATE.
"WALLS (ANY THICKNESS) INCLUDING ATTACHED PILASTERS, BUTTERESSES, PLINTH AND STRING COURSES ETC"
CEMENT CONCRETE GRADE M-20 (NOMINAL MIX) WITH 20 MM MAXIMUM SIZE OF STONE AGGREGATE.
"FILLING BY AVAILABLE EXCAVATED EARTH (EXCLUDING ROCK) IN TRENCHES, PLINTH, SIDES OF FOUNDATIONS ETC. IN LAYERS NOT EXCE
CEMENT CONCRETE GRADE M-10 (NOMINAL MIX) WITH 40 MM MAXIMUM SIZE OF STONE AGGREGATE
THERMO-MECHANICALLY TREATED BARS. (FE 500 D OR MORE)
"FOUNDATIONS, FOOTINGS, BASES OF COLUMNS, ETC. FOR MASS CONCRETE."
CEMENT CONCRETE GRADE M-20 (NOMINAL MIX) WITH 20 MM MAXIMUM SIZE OF STONE AGGREGATE.
BRICK WORK WILL WELL BURNT OPEN BHATTA BRICKS CRUSHING STRENGTH NOT LESS THAN 25KG/CM² AND WATER ABSOPTION NOT MORE THAN
MOORUM/HARD COPRA
CEMENT CONCRETE GRADE M-10 (NOMINAL MIX) WITH 40 MM MAXIMUM SIZE OF STONE AGGREGATE
THERMO-MECHANICALLY TREATED BARS. (FE 500 D OR MORE)
"FOUNDATIONS, FOOTINGS, BASES OF COLUMNS, ETC. FOR MASS CONCRETE."
CEMENT CONCRETE GRADE M-20 (NOMINAL MIX) WITH 20 MM MAXIMUM SIZE OF STONE AGGREGATE.
THERMO-MECHANICALLY TREATED BARS. (FE 500 D OR MORE)
"COLUMNS, PILLARS, PIERS, ABUTMENTS, POSTS AND STRUTS."
CEMENT CONCRETE GRADE M-20 (NOMINAL MIX) WITH 20 MM MAXIMUM SIZE OF STONE AGGREGATE.
BRICK WORK WILL WELL BURNT OPEN BHATTA BRICKS CRUSHING STRENGTH NOT LESS THAN 25KG/CM² AND WATER ABSOPTION NOT MORE THAN
THERMO-MECHANICALLY TREATED BARS. (FE 500 D OR MORE)
"LINTELS, BEAMS, PLINTH BEAMS, GIRDERS, BRESSUMERS AND CANTILEVERS."
CEMENT CONCRETE GRADE M-20 (NOMINAL MIX) WITH 20 MM MAXIMUM SIZE OF STONE AGGREGATE.
BRICK WORK WILL WELL BURNT OPEN BHATTA BRICKS CRUSHING STRENGTH NOT LESS THAN 25KG/CM² AND WATER ABSOPTION NOT MORE THAN
"LINTELS, BEAMS, PLINTH BEAMS, GIRDERS, BRESSUMERS AND CANTILEVERS."
THERMO-MECHANICALLY TREATED BARS. (FE 500 D OR MORE)
"REINFORCED CEMENT CONCRETE WORK IN BEAMS, SUSPENDED FLOORS, ROOFS HAVING SLOPE UP TO 15° LANDINGS, BALCONIES, SHELVES,
"SUSPENDED FLOORS, ROOFS, LANDINGS, BALCONIES AND ACCESS PLATFORM."
THERMO-MECHANICALLY TREATED BARS. (FE 500 D OR MORE)
"REINFORCED CEMENT CONCRETE WORK IN BEAMS, SUSPENDED FLOORS, ROOFS HAVING SLOPE UP TO 15° LANDINGS, BALCONIES, SHELVES,
1:4 (1 CEMENT: 4 SAND)
1:4 (1 CEMENT: 4 SAND)
1:3 (1 CEMENT: 3 FINE SAND)
"PROVIDING AND LAYING VITRIFIED FLOOR TILES (WITHOUT SOLUBLE SALT) OR PRINTED (WITH SOLUBLE SALT) NANO POLISHED (GLOSSY
APPLYING ONE COAT OF CEMENT PRIMER OF APPROVED BRAND AND MANUFACTURE ON WALL SURFACE : CEMENT PRIMER.
"PROVIDING AND APPLYING 1.0 MM THICK WHITE CEMENT BASED WALL PUTTY OF BEST QUALITY, OVER PLASTERED SURFACE TO PREPARE TH
TWO OR MORE COATS ON NEW WORK
"IN GRATINGS, FRAMES, GUARD BAR, LADDER, RAILINGS, BRACKETS, GATES AND SIMILAR WORKS."
PAINTING STEEL WORK WITH DELUXE MULTI SURFACE PAINT TO GIVE AN EVEN SHADE. TWO OR MORE COAT APPLIED @0.90 LTR/
AREA OF SLAB UPTO 0.50 SQM
CEMENT CONCRETE GRADE M-20 (NOMINAL MIX) WITH 20 MM MAXIMUM SIZE OF STONE AGGREGATE
LIGHT POINT/FAN POINTS.SHORT POINT
LIGHT POINT/FAN POINTS.SHORT POINT
LIGHT POINT/FAN POINTS.SHORT POINT
3 PIN 6 AMP SOCKET OUTLET ON SEPARATE BOARD SHORT POINT
3 PIN 6 AMP SOCKET OUTLET ON SEPARATE BOARDMEDIUM POINT
3 PIN 6 AMP SOCKET OUTLET ON SEPARATE BOARDLONG POINT
"POINT WIRING INCLUDING METALLIC SWITCH BOX, SHEET, SWITCHES, SOCKETS FOR 3 PIN 6 AMP. SOCKET OUTLET POINT WITH 1.5 SQ.
2X2.5 SQ.MM.
4X2.5 SQ.MM.
SHORT POINT ON SEPARATE BOARD
MEDIUM POINT.ON SEPARATE BOARD
LONG POINT.ON SEPARATE BOARD
ON SEPARATE BOARD EXTRA LONG -I
"SUPPLING AND FIXING OF APPROVED MAKE STEP TYPE ELECTRONIC FAN REGULATOR INCLUDING CONNECTION ETC. AS REQUIRED ON EXISTI
CEILING FAN (ENERGY SAVER 60 W)-1400 MM SWEEP
400 SWEEP
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.05 MB
tender.pdf
Tender Documents • 1.85 MB
NIT.pdf
Other Document • 0.04 MB
BOQ_555566.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .