Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹70.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹73.9 L+₹1.3 L (1.84%)Rejected-Finance 583 URBAN ESTATE II HISAR 125005 | HISAR | HISAR | HARYANA | 125005 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹76.0 L+₹3.4 L (4.72%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹81.9 L+₹9.3 L (12.8%)Rejected-Finance VPO SATROD KALAN HISAR HARYANA | HISAR | HISAR | HARYANA | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹82.8 L+₹10.2 L (14.0%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹1.7 L
Closing Date
30 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Mathura
HQ CWE Mathura Cantt
ADDN / ALTERATION INCLUDING REPAIR IN OLD TYPE JOCS / OR ACCN AT JOGINDER VIHAR AT HISAR MIL STN UNDER GE (WEST) HISAR
2020_MES_367992_1
CWE/MTR/HSR(W)/36 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
Hisar
Class C cat a (i)
7 documents required · 7 mandatory
₹1,000
GE (West) Hisar
₹1.7 L
Yes
27 Jan 2021
20 Oct 2020
2 Dec 2020
20 Oct 2020
30 Nov 2020
18 Nov 2020
60 days
Amount
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc. 1.50 sqm & n.exc 4.00 sqm each complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n exc. 1.50 sqm each complete all as specified and directed.
S&F Pressed steel frames for doors with one or more rebates including necessary lugs, hinges, lock strike plate, size of frame 125 x 60mm complete all as specified and directed.
S&F Pressed steel frames for doors with one or more rebates including necessary lugs, hinges, lock strike plate, size of frame 105 x 60mm complete all as specified and directed.
M&L cement concrete (1:3:6) type C-1 filling of pressed steel frame and hold fast block etc including necessary form work complete all as specified and directed.
M&L 35 mm thick factory made glazed and skeleton shutters of 2nd class HW open rebated and prepared to receive glass/gauze (without sash bar) etc edges or framing plain chamfered or rounded fitted with cut or mitred beads for securing glass etc as specified in SSR pt-1 section 8 and cluase 8.24 (a) complete all as specified and directed.
S&F 35mm thick factory made IInd class hard wood panelled door shutters (two panel) with panels of 12 mm thick BWR plywood having seven ply with commercial veneers on both face of BWP grade and bonded with phenol formaldehyde synthetic resin adhesive ISI mark. The size of rail & stile as per IS:1003 (Part-I) kilnseasoned and chemically pressure treated complete all as specified and directed.
S&F for 150mm long Extruded aluminium alloy handles, cast type, anodised complete all as specified and directed.
S&F 200mm long Aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F 250mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy complete all as specified and directed.
M&L for preparation of new wooden surfaces of any description not otherwise described exc 10 cm width or girth and applying two coats of synthetic enamels paints over a coat of pink primer complete all as specified & directed.
S&F butt hinges 100mm stainless steel including necessary welding if required complete all as specified and directed.
S&F 300mm, Mild Steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
M&L for pressed steel shutter (cup board shutter) 1mm thick including pressed steel frame of 1.25mm thick sheet, 12mm dia MS rod for locking two nos of chromium plated handle and one godrej pattern lock including two coats of spray painting over a shop coat of primer fixed to wall with necessary fixing lugs complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and removal complete all as specified and as directed.
M&L for coloured glazed ceramic tiles of size 450 x 300 x 7mm thick as in vertical surface like dado or skirting set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering in cement mortar (1:3) complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc, laid bedded and pointed in any mortar complete all as specified and directed.
M&L 20-25mm thick Kota stone slabs of size 550 x 550mm (minimum) over and including 20mm thick screed layer in CM (1:3), laid and jointed with grey cement slurry mixed with pigment to match the shade of stone incl rubbing & polishing complete all as specified and directed. Note : Kota stone on cooking platform/treads of steps shall be in one peice only.
M&L 20-25mm thick Kota stone slabs (100/150mm x 550mm) as in vertical surfaces like dado or skirting / riser of steps over 10mm thick rendering in CM (1:3) set & joined in neat cement slurry and pointed in coloured cement to match incl rubbing & polishing complete all as specified and directed. Note : Kota stone on riser of steps shall be in one peice only.
M&L for 20 mm thick granite stone slab topping table rubbed and polished (one piece) in cooking platforms laid over 15mm thick cement screed bed or bedding layer in CM (1:3) including pointing in white cement (1:2) using marble dust complete all as specified and directed.
Demolition of cement concrete in ground floor and paving n.exc 15cm thickness below or above ground level complete all as specified and directed.
M&L for non-skid ceramic coloured tiles 7 to 8mm thick (Square/rectangular) area of each tiles exceeding 0.18 sqm but not exceeding 0.36 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick cement screed bed CM (1:4) over and including 25mm thick PCC 1:2:4 type B-0 complete all as specified and directed.
Supply only water proofing compound complete all as specified and as directed.
S&F in repair fancy type stainless steel curtain rod 25mm dia with SS brakcet, knobs, rings @ 10cm c/c etc complete all as specified and directed.
S&F factory made steel window / ventilator, ISI Marked, (Box type) with side hung shutter including projecting type hinges with steel handle and tower bolt and steel peg stay with glazing bar, dovetailed or welded including one shop coat of zinc chromate primer and making good disturbed surfaces of walls complete all as specified and directed. Note : HQ CEJZ Drawing No TD/2013/01 Sheet 1/3,2/3,3/3.
S&F factory made steel window / ventilator, ISI Marked, (Box type) with side hung shutter including projecting type hinges with steel handle and tower bolt and steel peg stay without glazing bar, dovetailed or welded including one shop coat of zinc chromate primer and making good disturbed surfaces of walls complete all as specified and directed. Note : HQ CEJZ Drawing No TD/2013/01 Sheet 1/3,2/3,3/3.
S&F factory made steel ventilator (Box type) with top hung shutter incl hinges, steel peg stay including one shop coat of zinc chromate primer complete complete all as specified and directed. Note : HQ CEJZ Drawing No TD/2013/01 Sheet 1/3,2/3,3/3.
M&L MS window guard bars including necessary welding to frames confirming to Fe-290 gde E-165 complete all as specified and directed.
M&L for preparation of new steel surface of any description not otherwise described exc 10cm width or girth and applying two coats of synthetic enamels paints over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of new steel surface of any description not otherwise described exc 10cm width or girth and applying two coats of synthetic enamels paints complete all as specified and directed.
S&F figured glass 3mm thick pin head type and glazing with oil putty and securing with glazing pins not exceeding 0.50 Sqm in each pane complete all as specified and directed.
M&L 3mm thick sheet glass, ordinary quality and glazing with oil putty and securing with glazing pins area n.exc 0.5 Sqm in each pane complete all as specified and directed.
M&L 3mm thick sheet glass, ordinary quality n.exc 0.5 Sqm in each pane after hacking out old broken glass (any thickness, size, quality or description) from the frames (wooden / steel), glazed with oil putty and secured with glazing pins complete all as specified and directed.
S&F galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
S&F in repair galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
M&L 40mm thick cement concrete flooring 1:2:4 type B-1, using 20mm graged stone aggregate finished the surface even & smooth without using extra cement complete all as specified and directed.
M&L for 50mm thick cement concrete type C–1 (1:3:6) using 20mm graded stone aggregate as in plinth protection and PCC paved area and finishing the surface even and smooth without using extra cement complete all as specified and directed.
Taking down cement plaster including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed.
M&L for 15mm thick rendering in cement mortar (1:6) on fair face of brick walls/ concrete surfaces and finished even and smooth without using extra cement complete all as specified and directed.
M&L rendering 15mm thick on fair faces of brick work or concrete surfaces in two layers, first layer of 10 mm in CM 1:6 and top layer 5 mm in CM 1:4, top layer mixed with using liquid water proofing admixture as per manufacturer instruction and finishing surface even and smooth without using extra cement complete all as specified and directed. Note : Water proofing admixture shall be measured and paid for separatly.
M&L 5mm thick rendering in CM (1:3) on concrete surfaces of ceiling complete all as specified and directed.
M&L Rough cast plaster under coat not less than 10mm thick in C:M 1:3, while it is still in plastic state the rough cast mixture consisting of crushed stone or fine gravel agg (size 6 to 12mm) mixed with coarse sand and cement in the ratio of 1:1:1 shall be applied and finished even on external wall upto cill height complete all as specified and directed.
M&L two coats of Oil bound distemper on new plastered or unplastered surfaces over and including 1mm thick acrylic wall care (Birla / JK white / Asian / Berger) putty and a coat of alkali resistant primer on walls including preparation of surfaces complete all as specified and directed. Note : The work under this item shall be got carried out by contractor from authorised applicator of manufactrurer by using modern technique.
M&L for preparation of new plastered or unplastered surfaces of ceiling / soffit and applying three coats of white wash complete all as specified and directed.
M&L preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
S&F in repair vitreous china squatting pan (1st quality) ISI marked Orrisa pattern size 580mm x 440mm white with integral foot rest with CI ‘P’ or ‘S’ trap including connection to trap and to flushing pipe anti syphonage pipe etc and fixing in lime concrete (1 lime, 2 sand and 5 aggregate), 150mm thick alround and finished just below level of rim of pan to receive the floor finishing complete all as specified and directed.
S&F in repair, PVC low level cistern 10 lit capacity, valveless, syphonic action type with float, handle incl 32mm dia flush pipe of polyethylene complete all as specified and directed.
S&F in repair vitreous china wash basin, white, flat back, size 550 x 400mm with 32mm bore waste fitting of PTMT (minimum weight 45 grams) and PVC waste pipe 32mm bore and 15mm bore CP brass pillar tap cast copper alloy with captan head screws and fixing with new brackets including cutting and pinning in ends of brackets complete all as specified and directed.
Taking up or down steel water tubing and connection including cleaning for refixing of 15mm bore complete all as specified and directed.
Taking up or down steel water tubing and connection including cleaning for refixing of 20mm bore complete all as specified and directed.
S&F for GI tubing 15mm bore with all fittings and fixed complete to walls, ceilings or laid in floors medium grade complete all as specified and directed.
-ditto- as above but fixing only.
S&F for GI tubing 20mm bore with all fittings and fixed complete to walls, ceilings or laid in floors medium grade complete all as specified and directed.
-ditto- as above but fixing only.
S&F in repair 15mm bore chromium plated cast copper alloy bib taps with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F 15mm bore angle valves fancy type chromium plated cast copper alloy with crutch or butterfly handles screwed down high pressure screwed both ends for iron pipe or brass ferrule complete all as specified and directed.
S&F in repair 20mm bore stop valves cast copper alloy with crutch or butterfly handles screwed down high pressure screwed both ends for iron pipe or brass ferrule complete all as specified and directed.
S&F 15mm bore stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions chromium plated (long shank concealed type) and fixed to pipe or brass ferrule complete all as specified and directed.
S&F in repair brass chromium plated shower rose 125mm size with or without swivel joints fitted to 15mm bore steel pipe or union complete all as specified and directed.
S&F towel rail 600mm long of PTMT fixed with and including chromium plated brass screws and wooden / plastic cleats (minimum weight 190 gms) complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for chajjas, roof projection & manhole covers, RCC water tanks (reinforcement cut as required to facilitate demolition) complete all as specified and directed.
M&L 60mm thick machine pressed precast cement concrete rubberised glossy finish interlocking paver block with using grey cement and pigments of grade M-35 of any shape and size confirming to IS-15658-2006 such as I-Shape, unioctagonal, three X, dumble, zigzag etc laid over and including 25mm thick sand cushion complete all as specified and directed.
M&L for 75mm thick PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in Sub base of ground floors complete all as specified and directed.
S&F mild steel TMT bars as in reinforcement 10mm dia & over cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel (wire) annealed not less than 0.9mm dia complete all as specified and directed.
M&L for TMT MS bars of 5mm dia and upto 10mm dia as in stirrups and spacers cut to lengh bent to shape reqd incl cranking bending spirally for hooking for column and binding with MS annealed wire not less than 0.9mm dia complete all as specified and directed.
M&L for Cutting holes in brick walls built in cement mortar / concrete for inserting support for chhajjas / cooler flatforms / cooler stand etc and making good dismantelled portion in cement mortar 1:3 or PCC 1:2:4 type B1 as required super ficial area of cutting exc 250Sqcm but n.exc 500Sqcm complete all as specified and directed. Note : Cutting holes shall be corried out by core cutting machine.
S&F PVC water tank triple layer white in colour rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted & fixed in position of capacity 500 ltr complete all as specified and directed.
S&F ball valve 20mm bore high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed, (minimum weight 210 gms) complete all as specified and directed.
S&F in repair 110mm dia PVC rain water pipe single socketed with rubber joint, jointed with solvent cement fixed to wall with necessary clamps complete all as specified & directed.
S&F 110mm bore PVC (SWR) bends any radius complete all as specified and directed.
M&L for complete removal of existing treatment, washing down and stopping of distempered and painted surfaces by using electrical operated grinder and applying two coats of oil bound distemper over 01 mm thick acryllic wall care putty over a coat of alkali resistant primer as approved by GE complete all as specified and directed. Note : The work under this item shall be got carried out by contractor from authorised applicator of manufactrurer by using modern technique.
M&L for preparation of old plastered surface of walls and applying one coat of white wash complete all as specified and directed.
M&L for preparation of old plastered surface of ceiling and applying one coat of white wash complete all as specified and directed.
M&L for preparation of old plastered surface of walls and applying two coats of cement base paint after complete removal of existing treatment complete all as specified and directed.
M&L for preparation of old painted steel surface of any description not otherwise described exc 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old painted wooden surface of any description not otherwise described, exc 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified & directed.
Dismantling brick tiles or terracing tiles, single layer on roofs complete all as specified and directed.
Demolition of mud phuska any thickness, removing rubbish off the premises and cleaning the surface complete all as specified and directed.
M&L 80mm thick average consolidated thickness, mud phuska on flat roofs including 25mm thick mud plaster and 3mm thick leeping plaster complete all as specified and directed.
M&L for 40mm thick brick tiles laid on mud mortar and joints grouted flush in cement mortar(1:3) mixed with 5% of crude oil by weight of cement on mud phuska complete all as specified and directed.
All as per Item No 80 (here-in-above) but except brick tiles.
M&L applying evenly a tack coat of bitumen 85/25 @ 1.20 Kg/Sqm including cleaning of roof surface complete all as specified and directed.
M&L cement concrete 1:2:4 type B-1 (20 mm graded stone aggregate) as in lintels upto 1.5m clear span, copings, bed plates (block), roof kerbs, cills, steps and other bands, parapet and railing upto 60cm height including use of necessary form work complete all as specified and directed.
S&F PVC connection 15mm size, of length 450mm, with PTMT nuts complete all as specified and directed.
Demolition of brick work built in cement mortar including all quoins, arches pillars etc complete all as specified and directed.
M&L brick work with FLY ASH bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and directed.
M&L for brick work with fly ash bricks straight or curved on plan to any radius in half brick thick walls built in CM (1:4) complete all as specified and directed.
M&L brick work with sub class 'B' bricks old size straight or curved on plan exc 6mtr mean radius, built in CM (1:6) but except bricks complete all as specified and directed.
Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended (reinforcement cut as required to facilitate demolition) work complete all as specified and directed.
M&L for M-25 (design mix) using 20mm graded stone aggregate as in slabs supported on walls, beams and columns in floor, roof landings, balconies, canopies and in shelves complete all as specified and directed.
S&F factory made solid panel PVC door shutters 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail on either side and as gap inserted for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, fixed in the frame at site as per specification & drawing as shown in SSR part II (2010) complete all as specified and directed.
S&F factory made plain Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tubes of 19 x 19mm having wall thickness 19 gauge, fixed in opening as per specification & drawing given in SSR Part-II 2010.
Demolition of cement concrete (unreinforced) as in sunken portion or of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Treatment of sunken floor slab compraises of the following specifications and all as specified :- (i) M&L for cleaning the sunken/lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. 40mm thick avg PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in padding conc to achieve proper slope including cutting holes in bricks or RCC wall for spout. (ii) Rendering of uneven surfaces with 6mm thick CM 1:4 mixed with integral water proofing compound @ 3% by wt of cement consumed. (iii) All junctions points of side wall where CI/GI pipes are passing through shall be sealed with epoxy puty. (iv) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean. (v) M&L for applying two coats of polymer modified cementious water proof coating as per manufacturs instruction to bottom and vertical sides up to finished floor level+100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed. (vi) GI pipe 50mm dia medium grade not less than 50cm long laid on each sunken floor as spout complete all as specified and direced by EIC. (vii) Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with integral water proofing compound 3% by wt of cement consumed as per manufacturer's specification including rounding of corners and junctions sloping towards spout. (viii) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 all round after painting with anticorrosive paint. Note :- (i) Test the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage seepage and to the entire satisfaction of GE. The treatment shall be carried out by authorised applicators of chemicals. Cost of testing is included in the rates quoted above. (ii) All debries obtained from site will be thrown away out side MD land by contractor at his own expense. (iii) The cost of integral water proofing compound deemed to be inclusive in quoted rate.
M&L PCC 1:7:12 type F-2 using 40mm graded stone aggregate as in filling in sunken portion complete all as specified and directed. Note : PCC filling in sunken portion shall be carried out after carrying out satisfactory testing of slabs / walls by filling of water for 72 hours
S&F sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed. (Note : +10mm tolerance in size /dimension of sink is permissible as per standard manufacturers catalogues of makes mentioned in Appendix 'B')
S&F stainless steel plate rack of size 900 x 600 x 300mm made out of 1.00mm thick stainless steel of first quality complete all as specified and directed.
Dismantling of cast iron pipes any size or bore as in soil waste or vent pipe including removal of cement joints fixed to wall or laid in floor complete all as specified and directed.
S&F sand cast, cast iron soil, waste and vent pipes 100mm bore in any length with or without ears with lead joint, laid in floor or fixed to wall complete all as specified and directed.
S&F sand cast, cast iron soil, waste & vent pipes 75mm bore in any length with or without ears with lead joint fixed to wall complete all as specified and directed.
S&F 100mm CI Bends (any radius), diminishing pieces or tapers (larger bore measured) fitted with oval access door complete all as specified and as directed.
S&F 75mm CI Bends (any radius), diminishing pieces or tapers (larger bore measured) fitted with oval access door complete all as specified and as directed.
S&F 100mm CI Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed.
S&F 75mm CI Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed.
S&F cast iron cowl 75mm dia complete all as specified & directed.
S&F cast iron cowl 100mm dia complete all as specified & directed.
S&F CI Nahani trap 75mm bore with grating incl jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
S&F MS joists, channel, angle, or tee sections, fixed independently without connection plate etc (cut to ordinary lengths i.e. within 20mm of the length indicated) complete all as specified and directed.
M&L Preparation of new plastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strenght of 550 Mpa as in roof covering / cladding to wall and in chhajjas fixed with self tapping screws complete all as specified and directed.
Demolition and breaking up drain pipes (salt glazed stone ware, AC or reinforced concrete) set in cement mortar internal dia of pipe 150mm complete all as specified and directed.
M&L for 150mm bore Reinforced concrete pipes class NP2 laid and jointed with collars in trenches complete all as specified and directed.
M&L for concrete bed to drain pipes in PCC (1:3:6) types C-2 including cradles for 150mm bore of pipes complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shafts, wells, cesspits, man holes, pier holes etc, not exc 10 sqm on plan and n exc 1.5m in depth and getting out complete all as specified and directed.
M&L for returning filling in approved excavated soil including spreading levelling and well ramming in layers n.exc 25cm thick complete all as specified and directed.
Removing excavated soil / material to a distance exc 250m but not exc 500m and depositing where directed at a level not exc 1.5m above starting point complete all as specified and directed.
Removing all disintegrated and loose concrete of any thickness including plaster if any in RCC Column, Chajja, slab, beams, lintels etc, removing all loose rust / scale from exposed reinforcement bars by using wire brushes and sand paper including cleaning of exposed surfaces of reinforcement with protective anti corrosive epoxy bonding chemical (make : Pidilite) and tied reinforcement bars / IRC fabric 50mm x 50mm x 12gauge if reqd to reinforcement concrete bonding primer uniformly to exposed surfaces and applying cement mortar 1:3:1 with MPC (1 Part cement : 3 Part Sand : 1 Part 6mm coarse aggregate) to an average thickness not less than 20 mm and removing debris outside MD land complete all as specified and directed. Note : The cost of IRC 50mm x 50mm x 12 gauge or reinforcement bars shall be deemed to be included in quoted rate.
S&F MS framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting including steel sheeting or other covering, doors etc to be prepared for hanging, fastening and fixing complete conforming to FE-410-w Gde E-250 as in garrage door and roof access door complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not other wise provided for complete all as specified and directed.
Taking down carefully surface aluminium point wiring with wooden battens / PVC conduit (light, fan, socket, bell or power) including fittings such as switches, ceiling roses, lamp holders, pendants, sockets, regulators etc and making good disturbed surfaces complete all as specified and directed.
M&L for point wiring with 1.5 sqmm PVC insulated and unsheathed FRLS single core multistanded copper conductor for one light / fan / bell point in and including PVC rigid non metallic concealed conduit 19/20mm dia, medium duty, ISI marked to be terminated & including pressed modular steel terminal boxes and modular cover plate of any module as required on site including 1.5sqmm PVC insulated and unsheathed FRLS single core multistranded copper earth continuity conductor controlled by one switch and / or one regulator complete including repairing the surface in CM 1:3 and finishing the surface as per existing treatment complete all as per specified and directed.
One light / fan / exhaust fan / bell point controlled by one switch.
One socket outlet 5 pin, 6 amp controlled by one switch on the same board.
One socket outlet 5 pin, 6 amp controlled by one switch on indepdendent board.
M&L for point wiring with 2.5 sqmm PVC insulated and unsheathed FRLS single core multistanded copper conductor for one light / fan / bell point in and including PVC rigid non metallic concealed conduit 19/20mm dia, medium duty, ISI marked to be terminated & including pressed modular steel terminal boxes and modular cover plate of any module as required on site including 2.5sqmm PVC insulated and unsheathed FRLS single core multistranded copper earth continuity conductor controlled by one switch and / or one regulator complete including repairing the surface in CM 1:3 and finishing the surface as per existing treatment complete all as per specified and directed.
Taking down old unserviceable / burnt submain wiring of any size including earth wire and making good of the disturbed surface and removing the material from site complete all as specified and directed.
M&L submain wiring with 2 runs of single core 4 sqmm PVC insulated unsheathed multistranded 1100 volts grade with FRLS copper conductor drawn through and including ISI marks PVC conduit concealed and conduit accessories of medium grade not less than 20mm dia including one run of single core 4 sqmm dia FRLS PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth conductor along with wiring and connected from DB to DB / main board complete all as specified and directed. Note :- Two run of 4 Sqmm cable and one run of 4 Sqmm earth cable and one run of 20mm PVC conduit shall be considered as a unit for measurements purpose.
S&F modular Switch 6 amp single Pole one way, one module 230 V flush type complete all as specified & directed.
S&F modular Switch 16 amp single Pole one way, one module 230 V flush type complete all as specified & directed.
S&F modular Socket 6 Amp two in one 2/3 Pin (Two module) out let flush type Multipurpose 230 V complete all as specified & directed.
S&F modular Socket 6/16 Amp two in one 2/3 Pin (Two module) out let flush type multipurpose 230 V complete all as specified & directed.
S&F modular bell push, 6 Amp one module 230 V complete all as specified & directed.
S&F Bell ding dong type AC 230 volt complete all as specified & directed.
S&F modular electronic ceiling fan regulator stepped type, 120 W, two module heavy duty suitable to work on 230 volts complete all as specified & directed.
S&F modular Ceiling rose 3 terminals complete all as specified & directed.
S&F in repair LED tube rod 18/20 W only complete all as specified & directed. Make : Cat part No LT5RT1-18-CDL of Crompton or equivalent make as specified in Appendix 'B'.
S&F in replacement only LED batten CRCA sheet box type fixture 4 feet, long single side connection suitable for 18/20W LED tube light rod with G13 lamp holders complete with mounting brackets & accessories as required with connections complete all as specified & directed.
S&F modular Lamp holder B-22 base, insulated body, batten / angle type complete all as specified and directed.
S&F LED bulb B22 base of capacity 9 W complete all as specified & directed. Make : Make - Cat Part No LTHPLEDLAMP9W/B22 of C&S or equivalent make as specified in Appendix 'B'.
S&F MCB SPN 240 volts 5 to 32 Amp breaking capasity 10 KA (type 'C') complete all as specified and directed.
S&F MCB single pole, 240 volts, 2 Amps to 5 Amp breaking capacity 10 KA (type 'C') complete all as specified & directed.
S&F MCB single pole, 240 volts, 5 Amps to 32 Amp breaking capacity 10 KA (type 'C') complete all as specified & directed.
S&F in repair sheet metal enclosure MCCB DB VTPN 4 way with 200 amps rated bus bar 415 volts double door with isolated Neutral Bar & Shrouded bus bar IP protection 43 suitable for mounting MCCB / MCB confirming to IS-13032, IS-8623, BS-5484 having door earthing complete all as specified and directed.
S&F MCCB three pole, 63 Amps 16 KA 415 volts including taking down old u/s MCB complete all as specified & directed.
Dismantling and refixing carefully ceiling fans of any make 1200mm sweep after servicing oiling and greasing complete all as specified and directed.
M&L for taking down unserviceable ceiling fans 1200/1400mm sweep, strip opening and removal of burnt out winding wire, rewinding the fans with suitable size of copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish and bearing etc. reassembling and refixing at site including testing complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground not less than 2.25 mtrs deep below normal ground level with top edge of the plate not less than 1.5 mtrs below normal ground level, surrounded from all sides with mixture of charcoal and common salt, connected to galvanized earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel protected by galvanised iron light grade 15 mm dia pipe and GI pipe 20mm light grade for water filling including 15x20mm reducer socket funnel wire mesh, RCC cover with concrete 1:2:4 using 8 mm# bar@100 mm c/c both ways ,PCC chamber pit with PCC (1:3:6) type C-2 and excavation and earth work,disposal of suplus spoil to a dstance not exceeding 50mtrs all as specified and shown on electrical plate No. 3 of 2009 (Part-I) including taking out old existing earthing complete all as specified and directed. Note :- The unit rate includes for protection pipe and GI wire 4mm dia from top of earth plate up to 7.5 meter above ground level.
Supplying laying, jointing, testing and commissioning of LT UG XLPE insulated screened PVC beded galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 volts grade complete of size 35 sqmm 3.5 core all as specified and directed. Note :- cable may be laid in trenches, under road, across the nallah, along poles / walls and in ducts etc. Excavation, earhtwork, sand cushioing, cable cover, pipe for cable protection to be measured and paid for separtely complete all as specified and directed.
M&L for Sand filling in trenches with clean dry fine sand unwashed 8cm before laying of cable and 15cm after laying & stretching of cable including gently punning by hand around cables complete all as specified & directed. Note : Punned thickness shall be measured.
M&L for brick covering to underground electric cable using sub class "B" old size brick laid dry flat per pendicular to the direction of cable complete all as specified and directed.
S&F sheet metal enclosure MCB DB SPN 8 way with 200 amps rated bus bar 240 volts double door with isolated Neutral Bar & Shrouded bus bar IP protection 43 suitable for mounting MCB DB confirming to IS-13032, IS-8623, BS-5484 having door earthing complete all as specified & directed.
S&F LED street light luminaries of cap 40 watt, aluminium pressure die cast housing with epoxy powder coated toughned glass cover having IP-66 protection prismatic polycarbonate cover with individual LED lenses complete all as specified and directed. Make : Havells Cat part No ENDURAPEARLNEOSL40WLED757PASYTOPC or equivalent make as specified in Appx 'B
Supply & fixing in replacement of Street light bracket made to shape out of GI pipe 40 mm bore light grade, 1.20 mtr length and fixed including MS Calmps of size FI 40 x 6mm - 02 nos, nuts, bolts and washers including two coats of aluminium paint over a coat of rex oxide primer complete all as specified and directed.
M&L for replacement of 50 mm bore GI pipe light grade laid in trenches or fixed to wall / pole for protection of cable / earthing strip etc complete all as specified and directed.
Siya constructions
M/s Pioneer Construction Co.
M/S RAJINDER SINGH
LACHHMAN SINGH AND BROTHERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .