Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹23.4 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹26.9 L+₹2.9 L (12.1%)Rejected-Finance | L-2 | Rejected-Finance L-2 | |
| 3 | L-3₹31.3 L+₹7.3 L (30.6%)Rejected-Finance | L-3 | Rejected-Finance L-3 | |
| 4 | L-4₹31.6 L+₹7.6 L (31.7%)Rejected-Finance A 212B GALI NO 1 SHAKARPUR | DELHI | EAST DELHI | DELHI | 110092 | L-4 | Rejected-Finance L-4 | |
| 5 | L-5₹32.3 L+₹8.3 L (34.6%)Rejected-Finance | L-5 | Rejected-Finance L-5 |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
2 Apr 2024, 6:00 pmClosed
GE (AF) FARIDABAD
GE (AF) FARIDABAD
ADDN/ ALTN TO BUILDING NO P-33, P-35, P-36 AND P-46 IN TECH AREA OF MCC AF STN BASANT NAGAR IN AOR OF GE (AF) FARIDABAD
2024_MES_645040_1
GE (FBD)/AF-97/2023-2024
Open Tender
Civil Works
Item Rate
180 days
Delhi
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) FARIDABAD
₹87,000
Yes
16 Nov 2024
4 Mar 2024
4 Apr 2024
4 Mar 2024
2 Apr 2024
19 Mar 2024
4 Mar 2024 - 8 Mar 2024
Amount
Demolition of Brickwork or stone/ boulder masonry, built in Cement mortar including all quoins, arches, pillars, etc, but including ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-Charge.
M&L for Brickwork with subclass 'B' bricks (old size bricks), straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
All as per item No 02 above but except bricks.
M&L for brick work with sub class ‘B’ bricks (old size brick) straight or curved on plan to any radius in half bricks thick walls, built in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster of any description on concrete surfaces such as soffit of RCC slab, chajjas and brick walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15 mm thick in CM 1:6 on brick Work or concrete surfaces including finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for Rendering 15mm thick in CM 1:4 on of brick work or concrete surface finished even and smooth (w/o using extra cement) mixed with and incl WPC @ 3% by weight of cement as per user manual complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 10mm thick in CM 1:3 over concrete surface as on ceiling, chhajja, shelves etc to match with existing surfaces finish even and smooth w/o using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for Finishing walls with textured exterior paint of required shade : New work (Two coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm on new surfaces and obtain smooth finish using sand paper complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of new plastered surface and applying three coats of white wash on ceiling etc complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of old surfaces by removal of existing treatmen and applying three coats of white wash on ceiling primer etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered surface and applying on walls and applying two coat of plastic emultion paint and applying one coat of wall care putty 3 mm thick for smooth surfce complete all as specified and directed by Engineer-in-Charge.
All as per item No 12 above but on ceiling
M&L for preparation of old surfaces on walls by removal of existing treatment and applying two coats of plastic emulsion paint over a coat of acrylic primer incl 3 mm thick of wall care putty for smooth surface complete all as specified and directed by Engineer-in-Charge.
All as per item No 14 above but on ceiling
M&L for preparation of old painted surfaces removal of existing treatment and apply on, roof boarder, drops, fins, chajja / roof facia, column etc two coats of exterior emulsion paint over a coat of acrylic primer as per manufactures instruction complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered surface on walls/ceiling,roof boarder, drops, fins, chajja / roof facia, column surface obtain smooth finish using sand paper and applying two coats of exterior emulsion paint over a coat of acrylic primer as per manufacturer instruction complete all as specified and directed by Engineer-in-Charge.
M&L for Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade 'A' in on concrete slab 100mm complete all as specified and directed by Engineer-in-Charge.
M&L for Plain, Aluminium sheeting 0.56 mm thick, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) complete all as specified and directed by Engineer-in-Charge.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store yard and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
M&L for 1st quality non skid ceramic coloiured tiles joint free 7 to 8 mm thick (square/rectangular ) area of each tile exc 0.18 Sqm but not exc 0.38 Sqm as in floor & designed as approved by GE,set and jointed in neat cement slurry and pointed with white cement with colour pigment to match the colour of tiles over & incl 15 mm thick in bedding layer or screed bed in cement mortar (1:6) in floors etc complete all as specified and directed by Engineer-in-Charge. Note : shade & design as approved by GE.
M&L for 1st qualityGlazed ceramic colour tiles joint free in vertical surface 350x250x7/ 450x350x 7 mm thick set andjointed in neat cement slurry and pointed in white or colour cement to match with shade of tiles including 10mm thick rendering in CM (1:4) backing of wall tiles such as dado/skirting in vertical surface etc complete all as specified and directed by Engineer-in-Charge. Note : shade & design as approved by GE.
M&L for fully vitrified tiles 9 to 10mm thick (square/rectangular) polished, area of each tiles exc 0.42 sqm but not exc 1.00 Sqm in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match shade of tile over & incl 15mm thick screed bed in CM (1:4) for laying floor finishes having ulta/double charged/HD Vitrified tiles complete all as specified and directed by Engineer-in-Charge.
All as per item No 23 above but on vertical surface with 10mm thick screed in CM 1:4
M&L for vitrified tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles exc 0.36 sqm but n exc 0.42 sqm, in floors, set and jointed in neat cement slurry over and incl 15 mm thick screed bed or bedding layer in CM 1:4 for laying floor finishes and pointed in white or coloured cement to match the shade of tile and incl dismantling / demolition and rubbish off the primises etc complete all as specified and directed by Engineer-in-Charge.
All as per item No 25 above on vertical surface with 10mm thick screed in CM 1:4
M&L for outdoor Virified tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles n exc 0.36 sqm , in floors, dado , skirting etc. set and jointed in neat cement slurry over 15 mm thick screed bed or bedding layer in CM 1:4 for laying floor finishes and pointed in white or coloured cement to match and incl dismantling / demolition and rubbish off the primises etc complete all as specified and directed by Engineer-in-Charge.
M&L for 18 to 20 mm thick Kota stone slab flooring (Machine cut) with mirror polishing of any size laid over and incl 20mm thick bedding layer in cement mortar 1:6 over 75 mm thick PCC 1:4:8 type D-2 (using 40 mm garded stone agg) in sub base of flooring for laying floor finishes over neat cement slurry @ 3Kg/sqm over sub base , jointed and pointed in grey cement mixed with pigment to match the shade of slab including rubbing and polishing to achieve mirror finish complete as in flooring complete all as specified and directed by Engineer-in-Charge.
M & L for chequered tiles of size 300 x 300 x 25 mm thick (colour and glazed approved by EIC) with grey cement and pigments laid over & incl 15 mm thick screed bed in CM 1:6 bedded and jointed in neat cement slurry, incl dismantling old unserviceable complete all as specified and directed by Engineer-in-Charge.
M&L for Kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar laid over 10 mm thick 1:3 cement mortar jointed and pointed in grey cement mixed with pigment to match the shade of slab including rubbing and polishing to achieve mirror finish complete as in flooring complete all as specified and directed by Engineer-in-Charge.
M&L for Granite 18-20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms, wash basin platform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl moulding ,rounding of edgeing and dismantling complete all as specified and directed by Engineer-in-Charge.
M&L for Mirror polishing on marbel/granite/Kota stone/stone work where ever required to give hogh glossy finish complete all as specified and directed by Engineer-in-Charge.
Taking down chowkahts or frames with shutters (without taking off shutters from the frame) exceeding 1.5 Sqm but not exceeding 4 sqm each complete all as specified and directed by Engineer-in-Charge.
M&L for factory made solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with mild steel square tube, supplying and fixing in opening as per specification & drawing and complete all as specified and directed by Engineer-in-Charge.
S&F Pressed steel frames of size 105x60mm, made of 1.25mm thick sheet, for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed by Engineer-in-Charge.
S&F Pressed steel frames of size 125x60mm, made of 1.25mm thick sheet, for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate incl filling hollow of frame with plain cement concrete type B0 (1:3:6 )(using 12.5mm graded aggregate ,etc complete all as specified and directed by Engineer-in-Charge.
M&L for factory made, 2nd class hard wood, 35mm thick glazed and skeleton shutters, open rebated and prepared to receive glass / gauge etc. (without sash bars) edges or framing plain, chamfered or rounded fitted with cut or mitered beads for securing glass etc. size of members of shutters as specified in SSR Part - I section 8.20 (a), complete all as specified and directed by Engineer-in-Charge.
S & F in repair for stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples or wooden beads complete all as specified and directed by Engineer-in-Charge.
S&F 35 mm thick flush shutters, solid core construction, with particle board core and plywood face panels, veneered type on both sides face is covered with any type colour decorative face with lipping/frame to match complete all as specified and directed by Engineer-in-Charge.
S&F for Factory Made Solid PVC Moulded Door Shutter with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC sheet on the front face & 2 mm thick prelam PVC sheet on back side, supplying & fixing in frame at site as per specification & drawingand complete all as specified and directed by Engineer-in-Charge.
M&L for aluminium Anodized powder coated fixed frame of partiton or fixed window / ventilator , aluminium section weighting not less than 0.55kg/RM incl 4.8mm thick sheet glass oridinary quality ' frosted glass or ACP sheet joining with rubber beading , aluminium snap beading complete all as specified and directed by Engineer-in-Charge.
S&F aluminium wire guard mesh of 4mm nominal dia of wire and average width of aperture 75 - 85mm and fixed with aluminium frame / staples complete all as specified and directed by Engineer-in-Charge.
M&L for 4.8 mm thick float glass ordinary quality' frosted glass and glazing with aluminum beeding and gasket to aluminum framework in square exc 0.50 sqm in each pane in repair complete all as specified and directed by Engineer-in-Charge.
Easing andAdjusting aluminium door and window including refixing beading after replacement of defective portions such as door closer, aluminium handles, hinges, locks, new rubber gasket, aluminium beading, preleminated prarticle board, sheet glass etc complete all as specified and directed by Engineer-in-Charge. Notes : Door closer, door spring, aluminium beading, preleminated gasket, aluminum beading, preleminated particle board, sheet glass shall be measured and paid separately under respective item of schedules.
S&F floor door spring made of SS complete all as specified and directed by Engineer-in-Charge.
S&F door closer hydraulically regulated design No 2 (aluminium anodized) complete all as specified and directed by Engineer-in-Charge.
S&F Mortice lock 75mm vertical type 2 lever (Brass) complete all as specified and as directed etc complete all as specified and directed by Engineer-in-Charge.
S&F Neoprene/EPDM Rubber gasket for fixing aluminium door and window shutters etc complete all as specified and directed by Engineer-in-Charge.
S&F aluminium beading for fixing of aluminium door and window shutter etc complete all as specified and directed by Engineer-in-Charge.
S&F 150 mm long aluminium tower bolts for aluminium door and window shutter etc complete all as specified and directed by Engineer-in-Charge.
S&F aluminium handles 150 mm long for aluminium door and window shutter etc complete all as specified and directed by Engineer-in-Charge.
S&F aluminium handles 100 mm long for aluminium door and window shutter etc complete all as specified and directed by Engineer-in-Charge.
S & F for 3mm thick sheet glass ordinary quality glazing with oil putty in square n exc 0.5 sqm quality or description from steel frame and complete all as specified and directed by Engineer-in-Charge.
S&F 10 to 12 mm thick frosted glass door with 08 Nos of holes and two steel hinges and steel handles not less than 300 mm long on both sides of door, incl necessary locking arrangement complete all as specified and directed by Engineer-in-Charge.
M&L for 18mm thick water proof solid MDF Board prelaminated both sides of approved shade fitted with necessary arrangement as in kitchen cabinet back sides, partition, shutters and shelves, etc., fixed with solvent cement adhesive and stainless steel screws and providing 1mm thick PVC lipping to exposed edges, complete all as specified and directed by Engineer-in-Charge.
S & F for 30 mm Continuous (piano) hinges, mild steel, bright finish or elec trogalvanised complete all as specified and directed by Engineer-in-Charge.
S&F for Magnetic catcher suitable for kitchen cabinet shutters, complete all as specified and directed by Engineer-in-Charge.
S&F for 100 mm Hasp and staple, safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed by Engineer-in-Charge.
S&F in repair for Brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts 150mm long (ISI Marked) complete all as specified and directed by Engineer-in-Charge.
S&F for aluminum anodized barrel tower bolts of extruded section 150mm long (ISI Marked) complete all as specified and directed by Engineer-in-Charge.
S&F for Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed, 300mm long, complete all as specified and directed by Engineer-in-Charge.
S&F for Extruded brass handles, fabricated type polished 150 mm long complete all as specified and directed by Engineer-in-Charge.
M & L for one coat of synthetic enamel paint on steel surface including preparation of old steel surface plain or moulded, n exc 10cm width or girth when unconnected with other painting or when painted in a different tint complete all as specified and directed by Engineer-in-Charge.
M & L for one coat of synthetic enamel paint on steel surface including preparation of old steel surface width or girth exc 10cm complete all as specified and directed by Engineer-in-Charge.
M&L for one coats of synthetic enamel paint on wooden surfaces of any description over 10cm width or girth including preparation of old surfaces complete all as specified and directed by Engineer-in-Charge.
M & L for viterous china squating pan of (Orrissa Pattern) size 580x440 mm white with 'P' or 'S' trap front or back inlet and integral foot rest (excluding flushing cisteern and flush pipe) fixed in repair including lime concrete bedding as required set complete all as specified and directed by Engineer-in-Charge.
S&F in repair of PVC flushing cistem low level white with all accessories of 10 ltrs capacity incl flushing pipe, brackets and taking down of old CI/PVC flushing cistern complete all as specified and directed by Engineer-in-Charge.
S&F for rotational moulded polyetheylene water storage tanks three layered (cylingrical verticlal with closed top) of 500 ltr capacity, hoisted and fixed in repair in position including 20 mm dia float valve with aluminium fitting, dismantling existing water tank complete all as specified and directed by Engineer-in-Charge.
S&F for rotational moulded polyetheylene water storage tanks three layered (cylingrical verticlal with closed top) of 1000 ltr capacity, hoisted and fixed in repair in position including 20 mm dia float valve with aluminium fitting, dismantling existing water tank complete all as specified and directed by Engineer-in-Charge.
S&F in repair for 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repair for 20mm Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed by Engineer-in-Charge.
S&F for 20mm dia Nipple suitable for HDPE water tank.(Minimum weight 20mm 45gms) complete all as specified and directed by Engineer-in-Charge.
S&F 15 mm dia Unions. brass to connect iron to polyethylene and fixed complete all as specified and directed by Engineer-in-Charge.
S&F 20 mm dia Unions. brass to connect iron to polyethylene and fixed complete all as specified and directed by Engineer-in-Charge.
S&F stainless steel pegset of six suitable size of length complete all as specified and directed by Engineer-in-Charge.
Taking up or down 15 mm dia bore steel tubing and connection including cleaning for refixing or removed to store complete all as specified and directed by Engineer-in-Charge.
S&F for GI tubing 15mm bore medium grde with all fittings and fixed complete to wall and ceiling or laid in floors etc incl cutting chases in brick wall pinning in making good in CM 1:3 to facings where required complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing and connection including cleaning for refixing or removed to store, 20 mm dia bore complete all as specified and directed by Engineer-in-Charge.
S&F GI tubing 20 mm bore medium grade medium grde with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed by Engineer-in-Charge.
S&F for 110mm bore PVC pipes single socketed Pressure rating @4Kg/Sq cm length "medium grade " with rubber ring joint, fixed to walls with dash ture nut and bolt at every 2 mtrs length complete , incl taking up/down old pipe with all fittings complete all as specified and directed by Engineer-in-Charge.
All as per item No 80 above but laid in trench or in floor
S&F for 110mm bore PVC bends/junction any radius complete all as specified and directed by Engineer-in-Charge.
S&F for 110mm bore PVC bends/junction with access door any radiuscomplete all as specified and directed by Engineer-in-Charge.
S&F for 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed by Engineer-in-Charge.
S&F for 75mm dia PVC (SWR) multi floor trap, plain with grating including jointing with solvent cement complete all as specified and directed by Engineer-in-Charge.
S&F for 75 mm bore PVC pipes single socketed Pressure rating @4Kg/Sq cm length "medium grade " with rubber ring joint, fixed to walls with dash ture nut and bolt at every 2 mtrs length complete , incl taking up/down old pipe with all fittings complete all as specified and directed by Engineer-in-Charge.
All as per item No 86 above but laid in trench or in floor
S&F for 75 mm bore PVC bends/junction any radius complete all as specified and directed by Engineer-in-Charge.
Taking down old roof treatment in any description incl scrube and remove loose concrete, brick tiles, mud fuska, plaster, bitumen, oil grases and any other materials that might effect adhesion by wire brushing the surface and cleaning of the surface throughly with water and disposed off old materials complete all as specified and directed by Engineer-in-Charge.
M&L for 50mm thick cement concrete 1:2:4 type B-0 ( using 12.5mm graded stone aggregate) as in padding/ base on roof complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete type B0 1:2:4 (12.5 mm graded stone agg) providing in roof kerbs or mud stops, rounded or chamfered on edges on roof incl form wok complete all as specified and directed by Engineer-in-Charge.
Cleaning the internal surface areas throughly so that they are free of all contaminants like dirt and laitance & to remove all the loose materials by various mechanical means complete all as specified and directed by Engineer-in-Charge. (a) Removal of all surface Imperfections, protrusions, loose concrete & fittings of cracks using SBR latex Polymer Modified Mortar in the ratio Cement : Sand (1:4) and 5% by weight of cement . (b) Supplying and applying, water prrofing chemical for making liquid membrane (Acryllic Based High Performance Elastomeric Waterproof Coating) single component Liquid Applied water proofing members after applying One coat of Acrylic Primer @ 100ml/Sqm and allow the sealer coat to dry for two hrs, Apply first coat of @ 1.5 Sqm/ltr by roller or brush on the primed surface & allow drying for 4-5 hrs before application of second coat of @ 1.5 Sqm /ltr. Note :The laying of Liquid applied membrane shall be laid by the authorized & certified applicator of the manufacturer of liquid Membrane.
M&L for Rendering 10 mm thick on concrete surfaces on roof in CM 1:3 with WPC adding 3% by weight of cement and finishing the surface fair and even complete all as specified and directed by Engineer-in-Charge. Note :- WPC shall be paid sepratley
Supply only liquid waterproofing compound complete all as specified and directed by Engineer-in-Charge.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for, complete all as specified and directed by Engineer-in-Charge.
M&L for Precast RCC Nominal mix type B1 1:2:4 (20mm graded stone aggregate) in landings, chajjas,shelves and similar articles with plain faces, set in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge.
M & L for TMT bars 10mm dia and over, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with the mild steel wire (annealed) not less than 0.9mm dia or securing with clips and complete all as specified and directed by Engineer-in-Charge.
All as per item No 97 above but 6 to 8 mm dia and over and including in stirrups, spacers and binders and complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete unreinforced in of any desciption and in any position not otherwise specifically provided for (sunken floor) and concrete debris and rubbishoff to a distance n exc 100m complete all as specified and directed by Engineer-in-Charge.
M&L, for rendering 10mm thick in CM 1:3 with WPC in sunken slab complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of roof surface & applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 Kg/Sqm including APP based polymeric membrane minimum weighing 3.6 kg/sqm and minimum 3 mm thick reinforced wih polyster non wove fabric (wt not less than 150 gms/sqm) laid on primed surface by forced application, joints to be touched hot and width of overlaps not be less than 150 mm complete all as specified and directed by Engineer-in-Charge.
M&L, cement concrete 1:7:12 F-2 (40 mm graded stone aggregate ) in lean concrete complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete unreinforced in ground floors and paving n. exc 15 cm thickness below or above gound level , concrete debris and rubbish to a distance n exc 100m complete all as specified and directed by Engineer-in-Charge.
M & L for 75 mm thick PCC 1:3:6 type C-2 (using 40 mm stone aggregate agg. ) as in plinth protection / path/ any paved area complete all as specified and directed by Engineer-in-Charge.
M&L in repair for Soulwood WPC Exterior wall panelling size (2900x219x26) mm any colour/design approved by engr-in-charge, inclusive of fixing on to wall incl L Corner, moulding end caps and necessary frame work for fixed and screws as required at site complete all as specified and directed by Engineer-in-Charge.
S&F in repairs stainless steel letters (English/Hindi) and grade SS-204 consisting of 300 mm high, 50mm width and 25mm depth hollow wall fixed on walls fixed on wall surface ACP sheets board of any description using stainless steel screws of suitable size or best quality adhesive including LED lights fittings in each letters complete all as specified and directed by Engineer-in-Charge.
M&L for repair only to rolling shutter including necessary greasing, welding, locking arrangement including serviceing to gear box etc complete as to bring in service condtions etc complete all as specified and directed by Engineer-in-Charge.
M&L for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., incl welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed by Engineer-in-Charge.
M&L for repair only to collapsible steel gate including necessary greassing, welding, locking arrangement including serviceing etc complete as to bring in service condtions complete all as specified and directed by Engineer-in-Charge.
S&F 1.25mm thick Steel rolling shutters, gear operated type with bevel gear box and crank handle, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type incl taking down rolling shutters complete all as specified and directed by Engineer-in-Charge.
S&F Safety lever locks mild steel with 4 levers incl ball bearing for rolling shutters complete all as specified and directed by Engineer-in-Charge.
S&F vebetial blind for window including necessary items required for fix to wall complete all as specified and directed by Engineer-in-Charge.
S&F in repair door seals made of aluminium strip powder coated 20 mm wide and provided rubber/ cotton mat lining fixed with screws to door shutters up to 1m width opening complete all as specified and directed by Engineer-in-Charge.
S&F double legged door stopper of aluminium alloy with rubber complete all as specified and directed by Engineer-in-Charge.
Dismantling wall ceiling and boards, (fibere pulp, insulation etc.0 or insulation boards any thickness including cover fitllets complete all as specified and directed by Engineer-in-Charge.
M&L for providing and fixing 10 mm thick plaster of paris ceiling (Gypsum anhydrous) of approved design/pattern to flat surfaces incl all necessary MS frame work, 12 mm thick board and fittings as per standard practice and as per manufacturer's instrs reinforced with GI wire mesh incl dismantling of walls and ceiling board any type complete all as specified and directed by Engineer-in-Charge.
Taking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) complete including all electrical fittings & fixtures(DBs, submain,cables etc) and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall, complete all as specified and directed by Engineer-in-Charge.
M&L for one light/fan/exhaust fan point wiring controlled by one switch with PVC insulated unsheathed multi stranded copper conductor (FRLS) of size 1.5 Sqmm (for Phase colour code Red and for Neutral colour code Black) and one run of size 1.5 Sqmm PVC insulated unsheathed multi stranded copper conductor (FRLS) (as earth wire, colour code green) and connected to common earth dolly all as specified. , drawn through in and including concealed PVC Conduit medium grade, ISI marked 20 mm dia along with conduit fixing accessories and with pressed steel terminal box thickness 1.6 mm painted with one coat of black bituminous paint as a primary and two coats of enamel paint with 3 mm thick laminated sheet (Make: Hylam) for provision of switches/regulators complete all as specified and directed by Engineer-in-Charge. NOTE:-After rewiring cutting chasing portion should be matched with existing finishes of walls..
All as per item No 114 above but 5 Amp socket outlet, independent.
All as per item No 114 above but on the same board.
All as per item No 114 above but 2.5 sq mm wire for one 15 Amps socket outlet independent with continuous PVC insulated single core green colour copper earth wire of size 1.5 sq mm connected to common earth dolly.
Supply and fix switch piano, flush type single pole, one way, 5 Amps, 240 volts complete all as specified and directed by Engineer-in-Charge.
Supply and fix switch piano, flush type single pole, one way, 15 Amps, 240 volts complete all as specified and directed by Engineer-in-Charge.
Supply and fixing socket outlet 2 in 1, 3 pin 5 Amps complete all as specified and directed by Engineer-in-Charge.
Supply and fixing socket outlet 3 pin , 3 pin 15 Amps flush type complete all as specified and directed by Engineer-in-Charge.
Supply and fix ceiling roses, 3 phase, PVC/Polycarbonate, isolated body complete all as specified and directed by Engineer-in-Charge.
S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of LED tube light along with fixture,20W complete with all accessories with twin conductor complete all as specified and directed by Engineer-in-Charge.
S/Fix in replacement MCB DB TPN 4 Way factory made IP 42 protection class metal double door with 200 Amp rating bus bar with incomer as 4 pole MCCB 240/430V for fixing of MCBs/Isolators/RCCBs etc completed after dismantling old one complete all as specified and directed by Engineer-in-Charge.
Supply and install in replacement MCCB 4P fixed type 100 Amps rated with breaking capacity 16 KA complete all as specified and directed by Engineer-in-Charge.
Supply and install in replacement SPN enclosure including plug And socket with 16 to 32 Amp SP MCB C Curve 10 KA complete all as specified and directed by Engineer-in-charge .
Supply and fix exhaust fan sweep 300/ 250 mm in replacement made up of sturdy engineering plastic complete with louvers shutter , voltage 230 V , 50 Hz , 1200 RPM copper wound complete all as specified and directed by Engineer-in-charge .
M&L submain wiring with 2 runs of copper conductor PVC insulated unsheathed cable 1100 volt grade 4 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 2 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper complete all as specified and directed by Engineer-in-Charge. Note : Two runs of 4 sqmm cable alongwith one run of 2 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length).
M&L submain wiring with 2 runs of copper conductor PVC insulated unsheathed cable 1100 volt grade 6 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 2 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper complete all as specified and directed by Engineer-in-Charge. Note : Two runs of 6 sqmm cable alongwith one run of 4 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length).
M&L for earthing with galvanised steel plate electrode 60cmx60cmx6mm thick buried directly in ground (Earth pit not less than 2.25mtr deep from ground level) surrounded from all directions with charcoal dust, salt and edge of earth plate not less than 1.5 mtr below ground level connected to galvanised iron wire 4mm dia. earth lead by means of nuts, bolts and washers incl excavation and earth work PCC chamber and RCC cover of 1:2:4 type B-1 using XPM weighing not less than 4 Kg/Sqmm using 20mm graded stone aggregate for coping/under covers, 20mm dia GI pipe light grade for watering funnel wire mesh etc, complete all as specified and directed by Engineer-in-Charge and shown in electrical plate No-03 of SSR Part-I.
S&F in replacement street light GI pipe bracket 50 mm dia 1.50metre length (ISI marked) light grade bend to shape with two Nos MS clamp duly painted nuts and bolts etc complete all as specified and directed by Engineer-in-Charge.
S&F in replacement LED Street light fitting 45 W pressure die cast aluminium housing with lens and toughened glass top maintanable type , IP66 on building as secutiy light fitting ,the light fitting shall be fixed complete with all the connections complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of MCB SP 6 to 32 amps 230 Volt complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and directed by Engineer-in-Charge.
M&L for excavation in trenches not exceeding 1.5 m wide and and not exceeding 1.5 m depth in loose/soft soil and getting out complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, with excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm, complete all as specified and directed by Engineer-in-Charge.
Removal of surplus soil to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed by Engineer-in-Charge.
M & L for brick protection with sub class 'B' bricks laid dry flat over electric cable in trenches complete all as specified and directed by Engineer-in-Charge.
M & L for sand cushioning with a layer of sand 80mm thick consolidated before laying of cable and 150mm thick consolidated after laying of cable in trenches ducts for electric cable protection including consolidation complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engineer-in-Charge.
M& L for taking down and refixing Ceilling fan / exhaust fan of any type and rating on any surface complete all as specified and directed by Engineer-in-Charge.
High Tech Metal India
M/S Yamin
VED PRAKASH ARORA
Maninder Singh Lohia
SAGAR ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .