Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.0 LAccepted-AOC 254 MG ROAD LAMBA LANE JUNGLIGHAT PORT BLAIR SOUTH ANDAMAN ANDAMAN AND NICOBAR ISLANDS 744103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹15.1 L+₹1.2 L (8.35%)Rejected-Finance MES WORKS SITE CARNICOBAR ANDAMAN NICOBAR ISLAND | CARNICOBAR | NICOBAR | ANDAMAN AND NICOBAR ISLANDS | 744301 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹15.7 L+₹1.7 L (12.2%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹16.0 L+₹2.0 L (14.3%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹16.0 L+₹2.0 L (14.5%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
18 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(I)866EWS CARNICOBAR
GE(I)866EWS CARNICOBAR
SPL REPAIR TO SEWAGE LINE SEPTIC TANK AND SOAKAGE WELL IN VARIOUS LOCATION AT AF STATION CARNICOBAR
2021_MES_463156_1
8539/21-22/E8
Open Tender
Civil Works
Item Rate
180 days
AREA UNDER GE(I)866EWS CARNICOBAR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE(I)866EWS
₹28,000
Yes
11 Sept 2021
27 Jul 2021
25 Aug 2021
28 Jul 2021
18 Aug 2021
11 Aug 2021
60 days
Amount
Demolition of reinforced cement concrete of any description as in manhole/septic tank cover slabs in any position complete all as directed by Engineer in Charge
M&L for precast reinforced cement concrete (1:2:4) type B1 using 20mm graded stone aggregate as in manhole cover / septic tank manhole cover set in cement mortar (1:4) complete all as directed by Engineer in Charge.
M&L for TMT bars 8 to 10mm dia and over, cut to length, bent to shape as required, including crancking, bending spirally for hooping for column, hooking ends and binding with and including mild steel wires (annealed) not less than 0.9mm dia or secured with clips complete all as directed by Engineer in Charge.
Demolition of PCC block masonry built in cement mortar of any description and at any position complete all as directed by Engineer in Charge.
M&L for precast cement concrete (1:3:6) type C1 using 20mm graded stone masonry solid blocks exc 10 cm in width and setting in cement mortar (1:6) complete all as directed by Engineer in Charge.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for cooping, benching etc. complete all as directed.
M&L for PCC (1:2:4) ype B0 using 12.5mm graded stone aggregate as in benching /cooping complete all as directed by Engineer in Charge.
M&L for loose filling with aggregate of gauge 40 to 80mm as in soak pit, soakage well complete all as directed by Engineer in Charge.
M&L for rendering 10mm thick on fair face of concrete surface of wall in cement mortar (1:4) and finished with even and smooth without using extra cement all as specified & directed.
Excavation in trenches n exc 1.5mt wide and n exc 1.5mtr depth for foundation etc. for shafts, wells, cess pits, manholes, piers etc. not exc 10Sqm on plan and not exc 1.5mtr depth and getting out in soft /loose soil complete all as directed by Engineer in Charge.
Dismantling of cast iron or reinforced cement conrete drain pipe 100mm dia (internal) jointed in cement mortar including PCC haunching and bed concrete and taking out of trenches if required (excavation in trenches shall be measured & paid seperately) all as directed by Engineer in Charge.
All as per item non 11 here in before but for 150mm
M&L for concrete bed to drains to drain pipes including packing under and completely sorrounding pipes with cemet concrete (1:3:6) type C2 with using 40mm graded stone aggregate after they are laid and tested in trench for 100mm dia pipe complete all as directed by Engineer in charge.
All as per item no.13 here in before but for 150mm dia of pipe
S&F cast iron (spun) soil , waste pipe 100 mm dia in any length with or without ears, with cement joints , laid in trenches complete all as directed by Engineer in Charge.
All as per item no. 15 here in before but for 150mm dia pipe
Returning filling in and including spreading, watering and well ramming in layerss not exc 25cm in soft / loose soil complete all as directed by Engineer in Charge
Removing excavated material (soil) exceeding 50mtr but not exceeding 250mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as directed by Engineer in Charge.
M&L for PVC(SWR) pipe 110 mm dia single socketed in any length with rubber ring joints, fixed to wall complete all as directed
M&L for PVC(SWR) bend suitable for 110mm dia pipe with acess door complete all as directed
M&L for PVC(SWR) bend suitable for 110mm dia pipe with out acess door complete all as directed
M&L for PVC(SWR) junction single socketed 110mm bore, single (T) equal or unequal with acess door complete all as specified
M&l for PVC(SWR) 110mm vent cowl complete all as specified
M&L for matting double layers and fixing to frame or supports with munj or other approved string complete all as directed by Engineer in Charge.
M&L for PVC(SWR) pipe 75 mm dia single socketed in any length with rubber ring joints, fixed to wall complete all as directed
M&L for PVC(SWR) bend suitable for 75mm dia pipe with acess door complete all as directed
M&L for PVC(SWR) bend suitable for 75mm dia pipe with out acess door complete all as directed
M&l for PVC(SWR) 75mm vent cowl complete all as specified
M&L for Cast iron floor trap 100mm dia with grating includings jointing to waste pipe fixed in cment concrte type B1(1:2:4) using 20mm gradded stone aggregate complete all as directed
M&L for Cast iron floor trap 75mm dia with grating includings jointing to waste pipe fixed in cment concrte type B1(1:2:4) using 20mm gradded stone aggregate complete all as directed
M&l for PVC(SWR) Gully trap 125/110 mm , setting and jointing with solvant cement concrete type B-1 (1:2:40 complete all as directed
M&L for 50mm dia HDPE pope of pressure rating 6 Kg/Sqcm fixed to wall complete all as directed
ASHOK BISWAS
bansal construction
M/s Pooja Enterprises
RS ENGINEERING WORK
NAVJEEVAN ENTERPRISES
KML CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .