Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.4 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹19.4 L+₹3.0 L (18.0%)Rejected-Finance RZF 498 MG MARG RAJ NAGAR II PALAM DELHI CANTT 110077 | NEW DELHI | DELHI | 110077 | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹20.0 L+₹3.5 L (21.4%)Rejected-Finance | L3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | L4₹23.4 L+₹6.9 L (42.0%)Rejected-Finance H NO 74 6 JUTOGH CANTT SHIMLA HP 171 008 | SHIMLA | HIMACHAL PRADESH | 171008 | L4 | Rejected-Finance BEING NOT LOWEST | |
| 5 | L5₹23.8 L+₹7.3 L (44.3%)Rejected-Finance N A | NEW DELHI | DELHI | 110001 | L5 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
19 Apr 2024, 6:00 pmClosed
GE863 EWS
GE 863 EWS C/O 56 APO
REPAIR MAINTENANCE TO EXTERNAL ELECTRIC SYSTEM LT PANELS AND OTHER CONNECTED WORKS AT POOH KHAB and NAMGIA DOGRI UNDER AGE EM WE POOH IN GE 863 EWS
2024_MES_648196_1
GE 863/EWS-T-84 OF 2023-24REPAIR MAINTENANCE TO EXTERNAL ELECTRIC SYSTEM LT PANELS AND OTHER CON
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KHAB NAMGIA DOGRI AND POOH
As PER NIT
8 documents required · 8 mandatory
₹500
GE 863 EWS
₹36,000
Yes
27 Jun 2024
28 Mar 2024
26 Apr 2024
28 Mar 2024
19 Apr 2024
10 Apr 2024
28 Mar 2024 - 17 Apr 2024
Amount
Excavation in trenches not exc 1.5 Mtr wide and not exc 1.5 Mtr in depth in soft/loose soil for laying underground cables / erection of steel tubular poles / stay pit etc complete all as specified and directed.
Returning and filling in two parts (i) using riddled soil obtained from excavated soil upto depth of 30 cm (8 cm below cable and remaining above cable for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil complete all as specified and directed. Note- Excavated soil shall be riddled by using sieve to separate composite particles etc as per IS - 1255-1983 and refilling in trenches as in cable cushioning.
Removing excavated surplus material to a distance n exc 50m and depositing where directed at level n. exc 1.5m above the starting point complete all as specified and directed.
M&L for laying dry bricks old size with subclass 'B' made of burnt clay best quality locally available with permissible tolerance, laid straight trench for protection of cable complete all as specified and directed.
M&L for cement concrete (1:4:8) type D2 with 40 mm graded stone aggregate for poles foundation etc complete all as specified and directed.
M&L for cement concrete (1:3:6) type C1 with 20 mm graded stone aggegate for pole coping & road crossing etc including foam work complete all as specified and directed.
Supply and stringing in replacement ACSR conductor ,any size conductor in accordance with site requirement and binding on insulators by means of aluminium binding wire complete all as specified and directed .
S & F in replacement of galvanised steel wire of dia 4 mm for guard wire, continuous earth wire etc complete all as specified and directed.
M&L for steel tublar swaged poles complete with cast iron base plate, final taper plug, bolt, nuts & screw all as specified type 410 SP-31 (9 mtr long LT poles) and incl painting with one coat of red oxide primer and two coats of aluminium paint (inside and outside) and black bitumen paint on hidden surface in foundation incliding drilling of holes for fixing 'D' iron clamp & hooks for conineous GI earth wire, staying in a truly vertical porstion till the foundation is set to earthwire of any size complete all as specified and directed. Note:- (i) Excavation, earth work and PCC work shall be measured and paid separetaly
S & F in replacement cross arms bracings, supports, clamps and back plates fabricated from structural steel sections incl nut & bolts , washers welding, bending cold or hot drilling holes for bolts, washers in any shape or size including two coats of synthetic enamal paint over a coat of red oxide primer complete all as specified & directed.
S & F in replacement of pin type, porcelain vitreous, white, brown or green insulator incl one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 100 mm height 65mm dia for 1100 Volts grade complete all as specified and directed.
S & F in replacement shackle type porecelain vitreous white brown or green insulator for working pressure 1100 volts of 90mm dia and 75mm height incl galvanised steel straps of 31x3 mm size insulator and 12 mm dia bolt,washer & nuts complete all as specified and directed.
Removing and dismantalling old U/S over head line conductor (ACSR) of any size ( 2/4 line) and then cleaning , restringing in original position incl binding on insulators by means of aluminium binding wire, tapes complete all as specified and directed. (a) The rate quoted are inclusive of cutting/ removing all tree branches/ vegetation around 3 mtrs with 02 run of conductor. (b) Length of span is approx 30 mtrs with 02 run of conductor. (c) Adjusting & tightning of stay assembly shall be done wherever required.
S&F in replacement synthetic line separator of LT OH lines with nut,bolts & washers straight type horizontal configuration fixed at a point as directed and suitable for single phase 2 wire LT lines complete all as specified and directed.
S&F in replacement synthetic line separator of LT OH lines with nut,bolts & washers straight type horizontal configuration fixed at a point as directed and suitable for single phase 4 wire LT lines complete all as specified and directed.
M&L for Cleaning and preparation of surface of MS Tubular pole 9.00 Mtr long and applying, Painting of two coat with aluminium paint over a coat of red oxide primer on MS tubular pole 9 Mtr long. Writing of Pole Nos on 1.5 mtr height from coping of pole, with synthetic enamel paints in 25 CM height , complete all as specified & directed.
S & F in replacement of HDPE 50mm dia pipe PE 80 and 16 kg/sqcm laid in trenches / under road or fixed to wall as mechnical protection of UG cable complete all as specified and directed.
S & F in replacement of GI tubing 80mm (Medium grade) , laid in trenches under road as in mechnical protection of UG cable complete all as specified and directed.
Supplying, laying, jointing & testing in repair cable XLPE insulated in , IS 7098 (Part-I)-1988, ISI marked, screened, PVC sheathed, armoured electric power cable ( heavy duty) with aluminium conductor for working voltage upto and including 1100 Volts of croos sectional area 10 Sqmm 4 core with aluminium stranded, laid in trenches / fixed on pole / wall / passed through pipe complete with jointing material of LT Cable complete all as specified and directed. Note :- Any type of road cutting shall deemed to be be included in quoted rate and making good with PCC shall be measured separately.
All as per item no 19 above but size 16 sqmm 4 core
All as per item no 19 above but size 25 sqmm 3.5 core
All as per item no 19 above but size 35 sqmm 3.5 core
All as per item no 19 above but size 50 sqmm 3.5 core
All as per item no 19 above but size 70 sqmm 3.5 core
All as per item no 19 above but 95 Sqmm 3.5 core
All as per item no 19 above but 150 Sqmm 3.5 core
Supplying and fixing in repair 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 10 Sqmm stranded conductor ,complete all as specified & directed.
All as per item no 27 above but size 16 sqmm.
S&F in repair MCCB 4 pole 415V, Adjustable thermal and fixed magnetic type of capacity 400 Amps with breaking capacity 36 KA ,complete all as specified & directed. Make : Havells Cat Part No - IHLLSEB40400 or equavalent as approved.
S&F in repair MCCB 4 pole 415V, Adjustable thermal and fixed magnetic type of capacity 250 Amps with breaking capacity36 KA ,complete all as specified & directed. Make : Havells Cat Part No - IHLLSEB40250 or equavalent as approved.
Repair/ removing of tilted 9 mtrs LT pole by dismantling LT overhead line, excavating completely upto bottom of pole and re-fixing same pole at original position providing PCC (1:4:8) 15cm Depth in bottom of Pit for foundation bed concrete and PCC concrete (1:3:6) over foundation upto GL, all as specified and directed.
S&F in repair MCCB 4 pole 415V, Adjustable thermal and fixed magnetic type of capacity 160 Amps with breaking capacity 25/27 KA, complete all as specified & directed. Make : Havells Cat Part No - IHA13DB40160 or equavalent as approved.
S&F in repair MCCB 4 pole 415V, Adjustable thermal and fixed magnetic type of capacity 100 Amps with breaking capacity 16 KA, complete all as specified & directed. Make : Havells Cat Part No - IH13DB40100 or equavalent as approved.
S&F in repair MCCB 4 pole 415V, Adjustable thermal and fixed magnetic type of capacity 63 Amps with breaking capacity 16 KA, complete all as specified & directed. Make : Havells Cat Part No - IHA13DBF0063 or equavalent as approved.
Supply and fix in replacement of on load change over 4 pole with front handle, 415 volt AC, 50/60Hz, 63 amps complete all as specified & directed.
Supply and fix in replacement of on load change over 4 pole with front handle, 415 volt AC, 50/60Hz, 100 amps complete all as specified & directed.
Supply and fix in replacement of on load change over 4 pole with front handle, 415 volt AC, 50/60Hz, 160 amps complete all as specified & directed.
Supply and fix in replacement of on load change over 4 pole with front handle, 415 volt AC, 50/60Hz, 200 amps complete all as specified & directed.
Supply and fix in replacement of on load change over 4 pole with front handle, 415 volt AC, 50/60Hz, 250 amps complete all as specified & directed.
Supply and fix in replacement of 32 amps change over double pole with side operated handle, 230 volt AC, 50/60Hz, complete all as specified & directed.
Supply and fix in replacement of 63 amps change over four pole with side operated handle, 415 volt AC, 50/60Hz, complete all as specified & directed. Make : Havells Cat no IHBFFE0063 or equavalent as approved.
Supply and fix in replacement of 100 amps change over four pole with side operated handle, 415 volt AC, 50/60Hz, complete all as specified & directed. Make : Havells Cat No IHBFFE0100 or equavalent as approved.
Supply and Fix in replacment of terminal box made out of PVC with hinged door and locking arrangements of size 240x130x95 mm including four way connector, fixed on pole with necessary clamps complete all as specified & directed.. Make Sintex, Cat No- GSJB-2014 or equavalent as approved.
Supply and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified & directed.
Supply and fix in replacement of Bus bar chamber box in sheet metal enclosure of 100 Amps capacity, 4 way, 415 V complete all as specified & directed. Make:Havells Cat Part No IHBC010004 or equavalent as approved.
Material & labour in repair earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 mtr depth below ground level at any type of strata) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. Connected by 32x6 mm GI strip as earth lead by means of brass nuts and bolt, thimbles, check nuts, washers including concrete chamber of PCC 1:3:6 type C1 (using 20mm graded stone aggregate) with fair finish, internal surface of concrete chamber shall be given internal dia 300mmx300mm, 15mm thick plaster in CM 1:4) funnel with wire mesh, RCC pit cover of 320x320x80mm size in (1:2:4) Type B1 (using 20mm graded stone aggregate ) reinforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1 (2009) and specified including and provision of GI strip upto 7.5 mtrs long with 40 mm dia light grade GI pipe for protection and watering pipe of GI 20 mm bore, medium grade, including all excavation and earth work and connecting the earthling strip to panel, including testing on completion complete all as specified and directed. Note : (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick reinforced with XPM weighting not less than 4kg/sqm in lieu of CI cover.
Note:- The total shall subject to adjustment of credit of Rs 101879.20 for old Materials as per Schedule of Credit.
MRITUNJYA ASSOCIATES
JAMDAGNI ENGG WORKS
M/S SHIV NATH ENTERPRISES
M/S Rohit Enterprises
PRITPAL SINGH
H S ENTERPRISE
R B TRADERS
Dharm Singh Contractor
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .