| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.5 LAccepted-AOC | L1 | Accepted-AOC As per NIT | |
| 2 | L2₹5.8 L+₹27,898.92 (5.10%)Rejected-Finance | L2 | Rejected-Finance As per NIT | |
| 3 | L3₹5.9 L+₹37,792.16 (6.90%)Rejected-Finance DB 6 A HARI NAGAR NEW DELHI 64 | L3 | Rejected-Finance As per NIT | |
| 4 | L4₹6.1 L+₹67,274 (12.3%)Rejected-Finance U 57 OPP AGGARWAL NURSING HOME RAJU GAS AGENCY OFFICE VIJAY NAGAR NARELA DELHI DELHI 110040 | NORTH | DELHI | 110040 | L4 | Rejected-Finance As per NIT |
Tender Value
₹6.6 L
EMD Value
₹14,000
Closing Date
30 Mar 2026, 3:00 pmClosed
Sh. Sudhir Kumar
Old Zonal MCD Office, Vishal Enclave, Rajouri Garden, West Zone, Delhi -110027.
Improvement and development of Electrical installations at Jaswant Rai Dhingra Yoga Centre Fateh Nagar for upgradation to Ayushman Arogya Mandir in Ward No. 100 Fateh Nagar under West Zone.
2026_MCD_273375_1
EE/Elect-III/WZ/2025-26/NIT No. 140
Open Tender
Electrical Works
Percentage
90 days
Electric West Zone
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹14,000
6 Apr 2026
28 Mar 2026
30 Mar 2026
28 Mar 2026
30 Mar 2026
28 Mar 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.001 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. . Group C | 26 | Point | - | - |
| 1.002 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/
recessed steel/PVC conduit including dismantling as required. Group C | 18 | Point | - | - |
| 1.003 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A
modular socket outlet and 15/16 A modular switch, connections etc. as required. | 11 | each | 659 | ₹7,249 |
| 1.004 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | 30 | Metre | - | - |
| 1.005 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 x2.5 sq.mm+2 x2.5 sq.mm earth wire | 20 | Metre | - | - |
| 1.006 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 × 4 sq. mm + 1 × 4 sq. mm earth wire | 70 | Metre | - | - |
| 1.007 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 × 4 sq. mm + 2 × 4 sq. mm earth wire | 20 | Metre | - | - |
| 1.008 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm | 20 | Metre | - | - |
| 1.009 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 6 x 2.5 sq. mm | 10 | Metre | - | - |
| 1.01 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 4 sq. mm | 10 | Metre | - | - |
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.09 MB
14001ConditionsandCircular.pdf
Tender Documents • 18.21 MB
14001GCC.pdf
Tender Documents • 1.74 MB
14001DNIT.pdf
Tender Documents • 4.32 MB
14001Schedule.pdf
Tender Documents • 3.37 MB
BOQ_319072.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .