Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.2 LAccepted-AOC H NO 07 SHIVAJI NAGAR PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹29.5 L+₹63,319 (2.19%)Rejected-Finance 99 MODEL TOWN PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹31.4 L+₹2.5 L (8.66%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹31.9 L+₹3.0 L (10.5%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹32.2 L+₹3.3 L (11.4%)Rejected-Finance VPO BAILLY TEHSIL DALHOUSIE DISTT CHAMBA HP PIN 176303 | CHAMBA | HIMACHAL PRADESH | 176303 | L5 | Rejected-Finance Not being L1 |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
28 Aug 2020, 6:00 pmClosed
GE(SOUTH)PATHANKOT
GE(SOUTH)PATHANKOT
PROVN OF DEFI STANDBY DG SUP TO 2ASD SECURITY PERIMETER LIGHTS WATER SUPPLY FOR GD POST NO 11 12 and 13 GEYSERS FOR JCOS OR SINGLE ACCN AT 2ASD 18FAD GEYSERS INCL UPGRADATION OF LT DISTRIBUTION SYSTEM AT BHADURIYA COMPLEX SPECIAL REPAIR REPLACEM
2020_MES_362651_1
GES/PKT/T-18/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE(SOUTH)PATHANKOT
The firms not enlisted with MES shall meet the enlistment criteria of D class MES contractor and category b i
8 documents required · 8 mandatory
₹500
Yes
GE(SOUTH)PATHANKOT
₹92,000
Yes
16 Oct 2020
21 Jul 2020
31 Aug 2020
4 Aug 2020
28 Aug 2020
4 Aug 2020
Amount
Supply, install, test and commissioning of minimum 50 KVA/40 KW DG set diesel engine driven Generating set with alternator out put Voltage 415 Volts +/- 1% at set value of 415 V at a frequency 50HZ +/- 0.5% with STD inbuilt control panel and AMF panel to be errected inside acoustice enclosure (NTP for suitable for installing at 2ASD , Bhaduriya Complex,Pathankot), all mounted in acoustic enclosure and Control panel as per manufacturers design and specification as per approved CPCB-02 norms confirming to the detailed specifications appended below :-Make : CUMMINS- STAMFORD / KIRLOSKAR GREEN /CATTERPILLER or equivalent approved make of HQ CEWC
(I) ENGINE
(a) General: Suitable four stroke compressed ignition, radiator water cooled,Turbocharged aspiration, continuous duty with 10% overload capacity for 1 hour in 12 hours continuous running, with 50°C intake air temperature, CPCB-02 Euro emission engine ,turbocharged four stroke engine developing minimum 83 HP @ 1500 RPM under NTP conditions, coupled to alternator mounted on Channel Iron base frame with in built fuel tank of minimum capacity suitable for 12 Hrs continous running at 75% load. The prime mover provided should be as per IS specifications.
(b) Air intake system : Should comprise of dry type intake air filter mounted on engine, one in number vacuum indicator mounted on intake piping.
(c ) Exhaust System: Should comprise of one exhaust manifold, dry type, mounted on engine, one exhaust residential type silencer which should be positioned in such a way that the exhaust gas is not sucked by the fan on the radiator, thereby affecting the cooling system. The silencer should cater to the noise level tolerance prescribed in the relevant IS/BS. The silencer should be provided with flaps with a provision so that it will open only when the generator is running. The complete exhaust system shall be properly supported so that entire lot of the exhaust system shall not fall on the DG Set.
(d) Fuel System: Should comprise of disposal type element fuel filter, pressure type fuel pump mounted on engine, non return check valve in fuel supply and drain lines, wire braided hose between filter and pump, fuel system with suitable capacity electronic governor and engine mounted actuator. The fuel tank must have proper locking arrangement with level indicator and to be integrated with base frame.
(e) Cooling System: Should comprise of radiator designed, residential type silencer and tested for 50o C ambient temperature with 7 PSI pressure cap mounted on base rail. The thermostat installed in the engine coolant outlet, fresh water pump mounted on engine, fan and fan hub mounted on engine. A reservoir of 50% of radiator capacity to replenish coolant by gravity (as and when required) is also to be provided.
(f) Lubricating System: Should comprise of lubricating oil sump mounted on engine, gear driven lub oil pump mounted on engine, lubricating oil cooler-fresh water cooled integral with engine cool out circuit mounted on engine, oil filter lubricating with cap and lubricating oil dip stick for oil level check mounted on engine. The system should be capable of feeding lube oil to the main end & large end bearings, cam shaft, valve rocker gear and all moving parts.
(g) Starting System: Should comprise of suitable voltage DC electrical starter mounted on engine, with suitable maintenance free battery of capacity 12 V DC -2 Nos with suitable AH to be mounted in trays (having rubber insulation) on the main frame. It should have the provision to charge the battery from external sources during static condition and while running of the generator.
(h) AC Generator : The generator shall be horizontal and foot mounted,minimum 50 KVA, 415 Volts, 3 phase, 4 wire, 0.8 PF, 50 HZ, self excited, self regulated, brushless AC generator, suitable for an ambient temperature of 50° C with IP-23 enclosure class H insulation and temperature rise limited to class H as per following technical details
(i) Type, Brush less AC Generators
(ii) Output rating minimum 50 KVA/40 KW
(iii) Output Voltage: 415 ± 1% under all loading conditions and with maximum voltage Dip at full load 0.8 PF shall be < 20% as per OEM design.
(iv) Output frequency 50Hz ±0.5% up to 0.8 lagging.
(v) No of Phases: 3 phase with 01 Neutral (4 wire)
(vi) Mounting : Horizontal foot mounted.
(vii) Enclosure : Minimum IP-23 / Drip proof and screen protected.
(viii) Electronic Automatic voltage regulator with response time < 75 m sec and + range of voltage adjustment.
(ix) Class of insulation-'H'
(x) Short circuit withstand 3 times rated current for 3 secs and overload withstand capacity for continuous duty with 10% overload capacity for 1 hour in 12 hours continuous running, & 150% overload for 30 sec running (xi) Overspeed capacity 1800 RPM for 2 min
NOTE : Following shall be deemed to be included in cost quoted :-
(i) AMF Panel indoor type with IP-43 for minimum 50 KVA DG set
(ii) Suitable size RCC cement concrete foundation platform of canopy base with height as required at site to mount the generator as per manufacturer's instructions/ recommendations. The cost of foundation bed incl earth work and dismantling existing CC and foundation etc is deemed to be included in the quoted rate.
(iiI) Connecting cables, from existing panels and connecting cables , cables glands, cable lugs to new panel complete with all necessary accessories.
(iv) Install on the foundation, connecting fuel lines, cable etc.
(v) Test and commissioning complete
(vi) The cost of control cables from engine Control panel to AMF panel, transportation, installation, testing & commissioning etc shall be deemed to be included in the cost quoted.
(j) BASE FRAME: Shall be stand by and fabricated with CRCA sheet metal which shall be suitable to mount the engine, alternator and radiator, channel width of base frame shall be adequate to accommodate anti-vibration pads.
(l) AMF Panel :
Auto mains failure (AMF) panel, floor mounted type, vertical, factory made oudoor type, double door , canopy, fabricated out of 2.0mm thick CRCA sheet with angle iron base frame , dust and vermine proof, suitable for voltage 415 V Three Phase 4 wire, 50 HZ AC supply, weather proof, with IP-43 protection, with separate hinge door for each compartment & locking arrangement, with back door openable (Screwed), legs grouted in PCC complete including painting with two coats of epoxy powder paint over a coat of primer after under going a rigorous metal treatment process involving alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate and with aluminium busbar (TPN) of suitable rating, suitable double compression copper cable glands and including provn of the following suitable for minimum 50 KVA DG set.
(a) SWITCH GEAR :-
(i) Suitable rated 3 pole contactor for ALTERNATOR with thermal O/L relay suitable for minimum 50 KVA DG set
(ii) Suitabale rated 3 pole contactor for MAINS of suitable capacity.
(iii) 4 pole neutral contactor
(b) BACK-UP PROTECTION :-
HRC Fuse for short circuit protection.
(c) MICRO PROCESSOR BASED AMF MODULE :-
(i) Functions:-
(aa) Supply failure timer
(ab) Restoration timer
(ac) 3 in pulse automatic engine start/stop logic & engine fails to start lockout
(ad) Generator voltage ,current & frequency monitoring
(ae) Battery Voltage sensing & monitoring
(ab) Engine START/STOP
(iii) Metering : Remote monitoring system with GPRS/GSM modem with SIM card and 2 year data charges complete for monitoring all DG set parameters such as Hrs run, fuel level, Engine oil pressure, temperature, speed, Voltage/current/KW, battery monitoring , PF, frequency etc complete as per OEM design.
(iv) Annuciation (LED Type): (Faults)
(aa) Engine fails to start
(ab) Low lub oil pressure
(ac) High water temperature
(ad) Generator over load
(ae) Battery Voltage
(af) Low fuel level
(v) Additional features;-
(aa) Continuous reading digital voltmer/Ammeter/freqauency meter
(ab) Multifunction meters
(ac) Electronic (with counter display)KWH Meter.
(vi) Relay consisting of following features.
(aa) 3 Phase mains supply voltage sensing
(ab) Earth fault
(ac) Earth leakage
(ad) LED Indications
(ae) Engine ON, Load on DG
(af) Mains On, Load on Mians
(ag) overload
(vii) Push buttons (AMF Module by pass mode):-
(aa) Engine START/STOP
(ab) Geneator contactor CLOSE/TRIP
(ac)Mains contractor CLOSE/TRIP
(ad) Fault ACCEPT/RESET
(viii) Engine Meters:-
(aa) Lub oil pressure
(ab) Water Temparature
(ix) Battery Charger:- SMPS Based automatic float cum boost battery charger with following :-
(aa) DC Voltmeter & Ammeter
(x) Bypass switch of suitable rating
(m) Accessories :-
(i) 01 No standard mechanical and electrical tool box.
(ii) Internal covered tube lights.
(n) Acoustic Enclosure :-
Specially designed to meet CPCB norms 75dBA @ 1 mtr at 75% load under free field conditions. The Acoustic enclosure is made of CRCA sheets and a structural/sheet metal base with high quality noise absorbent and fire-retardant grade acoustic insulation material (P.U.Foam) complying to IS 8183 with two point lifting handles.
(a) Internal Lighting: Tube lights with protective mesh around it to be fitted inside the container for proper illumination
(b) Doors : The enclosure will be provided with suitable doors on the side and rear to enter the enclosure during operation and maintenance. All doors will be provided with lock and handles for opening/ closing the doors, retainers for holding the panel door.
(p) Painting Scheme
ISS shade 220 olive green 1994 or all as per manufacturers specifications
(q) Lifting/ Transportation arrangements :-
Container with suitable corners will be provided to lift the DG set along with container. This is suitable for road/ rail/ sea transportation.
(r) Trials:-
Trials on site should be given as per load tests prescribed and all functional trials should be shown.
Note : (i) The Engine, alternator, Control Panel, AMF Panel, Acoustic enclosure shall be integrated unit sourced shall be from OEM only as per Make given in Sch 'A'.(ii) The rate quoted inclusive for supplying next nearest higher capacity as per OEM design.
Notes :- (i) Testing of DG set shall carried by representative of AO. The cost of POL & resistive load bank required for testing the DG Set is deemed to be included in quoted rates. The DG Set shall run for a period of 12 Hours continuosly out of which 15 minutes on No Load , 2 Hrs 15 minutes of 25% rated load, 2 hrs on 50% rated load , 2 Hrs 30 minutes on 75 % rated load, 4 Hrs on rated full load, 1 Hrs on 110% rated full load.
(ii) First filling of coolant, Engine Oil, lubricants and fuel etc should be arranged by contractor for complete testing and quoted rate deemed to be inclusive for the same.
Material and labour for earthing with copper earth plate electrode of size 600 mm x600 mm x3.0 mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected with 20 x 3 mm copper strip as earth lead electrode by means of nuts, bolts and washers, GI medium grade pipe 40 mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, copper earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing).
Supply & fix copper strip 20mm x 3 mm buried in ground
Supply, laying,testing and commission of LT UG cable, XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of sizes 70 Sqmm 3.5 Core complete all as specified and directed. Note: Earth work ( Excavation, Returning & refilling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Sch 'A'.
Material, labour , testing & commissioning of cable end termination in door/out door, heat shrinkable type suitable for XLPE/ PVC cables of size 25 Sqmm to 50 sqmm 3½ or 4 core with working voltage 1100 volts make: Denson/ M Seal/Raychem.
Material, labour , testing & commissioning of cable end termination in door/out door, heat shrinkable type suitable for XLPE/ PVC cables of size 70 Sqmm to 150 sqmm 3½ or 4 core with working voltage 1100 volts make: Denson/ M Seal/Raychem.
Material and labour for earthing with steel earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, GI medium grade pipe 40 mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing).
Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables,pipeline, foundation filling of poles or stays or any other indicated positions complete all as specified and directed. (cable shall be laid 60 cm below ground level )
Returning filling in including spreading, leveling ,and well ramming, in layers not exceeding 25 cm each layer of any kind of soil.
All as per item No .08 here in before but exc 1.5 mtr or part there of in depth beyond 1.5 mtr depth.
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point.
M & L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of MES Schedule part-I (2009) Note : Sand shall be fined sand as specifed and punned thickness shall be measured and paid.
Supply and laying sub class 'B' bricks of old size (230x115x75 mm) or of size locally available , laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
Supply and fixing GI tubing light grade ISI marked with requisite fittings laid in trenches or crossing roads/paths/culverts/along poles/walls complete all as specified and directed for 40 mm dia size.
Cutting the tarmac / hard standings and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:3:6, type C1 matching with the surroundings all as directed.
M & L for supply, fixing and laying GI water tubing medium grade ISI marked with all required fittings such as bends elbows, tees short pieces, connector check nuts & threading complete in trenches/ on wall/ on roof all required at work site following Sizes.(Excavation shall be measured and paid separately).
(a) 50 mm dia bore
(b) 40 mm dia bore
(c) 25 mm dia bore
(d) 20 mm dia bore
(e) 15 mm dia bore
M & L in Gun metal gate valve ISI marked with iron wheel head screwed both ends for pipe of following sizes :-
(a) 50 mm dia bore
(b) 40 mm dia bore
(c) 25 mm dia bore
(d) 20 mm dia bore
(e) 15 mm dia bore
S & F Rotational moulded polyethylene water storage tanks triple layered of cap 2000 ltrs(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I with complete T&P for errection and installation all as directed.
Supply and Fix Gun Metal Horizontal lift check valve screwed, ISI marked, Class-I of size 50 mm dia bore all as specified and directed by Engr-in charge.
Supply and Fix Bronze relief valve straight type of size size 50 mm dia bore all as specified and directed by Engr-in charge.
Supply, laying, testing and commissioning of LT UG cable, XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of fsize 6 Sq mm X 4 core complete all as specified and directed. Note: Earth work ( Excavation, Returning & refilling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Sch 'A'.
M&L for PCC 1:4:8 type D2 with 40 mm graded aggregate as in foundation or any other indicated positions all as directed.
M&L for PCC 1:3:6 with 20 mm graded aggregate for coping of poles and stay including form work or any other indicated positions all as directed.
M&L for Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below normal ground level )with top edge of the plate not less than 1.5 Mtr below normal ground level connecting with galvanized iron GI earth wire 4mm dia by means of bolt nut check nuts and washers of galvanized iron and provision of GI tubing medium grade (ISI marked)of size 15mm for protection of GI earth wire upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing).
Taking down Coventional street light fitting of 150 W/250W or of any size/type HPSV/MH from height of pole of any location exceeding 7.0 m saggregating the serviceable fittings and keeping it in safe custody for re-using serviceable fittings complete all as directed.
Fixing only serviceable street light fittings of wattage 150 W any type HPSV/MH to street light pole of any location exceeding 7.0 m retrieved from item No.1 above including checking, inspecting, testing and commmissioning complete all as directed by Engr-in-Charge.
Supply & fixing LED street light fittings on rail/ steel tubular poles of height not exceeding 7.5 mtrs, comprising of epoxy powder coated housing, enclosed with glass cover in frame, of minimum wattage 72 Watts (with total lumen output not less than 6840 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) with ingress protection IP 65/66 and SPD of capacity 5 KV etc including necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket, PVC insulated 3 core 1.5 Sqmm copper wire if required will be measured and paid separately under relevant schedule items
Note : (i) MS Clamp fittings with nut bolts and GI bracket will be measured and paid separately.(ii) Minimum 2 years guarantee period of LED fittings (iii) Driver shall be IP 66 degree of protection potted seal type with inbuilt SPD and external SPD of capacity 10 KV to be provided in addition to inbuilt. (iv) Power factor more than 0.9 (v) Contractor shall submit LM 79 and LM 80 test reports from manufacturer from approved laboratory. The luminaries/fittings shall comply the following:- (a) Potted type driver with Driver efficacy : >85%(constant current driver), THD < 10%, (b) LED driver current <750 mA. (c) Efficacy of LED fixture > 95 lm/watt, (d) Efficacy of LED chip - > 130 lm/watt. (e) Surge protection : min 4KV& above as per IEC standards inbuilt in driver and external SPD of capacity 10 KV. (f) Working humidity : 10 % to 90% RH.
(g) LED make: Nichia/Philips lumiled/Cree/ Osram/Seoul. (h)LED Life shall be 50,000 Hrs at 70% lumens. (j) CRI > 70 (k) Lens: Each LED shall be of High Power (1 to 3 Watt only) with mandatory modular lens (l) Working temperature 0 to 50 Degree Centigrade. (m) Heat sink : Pressure die cast aluminium (n) Junction temp : 100 Degree Centigrade (p) Body fitting/enclosure: Pressure Die cast with company logo/make engraved or embossed in housing LM 6 grade with IP 65/66. (q) Impact code: > IK05 (r) LM 79 test report from NABL accredited third party lab instead of in house lab & LM 80 test report to be submitted before placing order. (s) Low/High Voltage, reverse polarity, overload and short circuit protection inbuilt in fixture.(t) Tenderer shall submit detailed specification sheet of luminaries for approval before placing order (u) 02 Years minimum warranty from OEM to submitted before claiming payment.
S&F, PVC insulated 3 core 1.5 Sq mm stranded copper conductor cable for connecting junction box to street light fitting, testing and commissioning all as directed. Make: Plaza/ Gloster/Polycab/Havells.
M&L for bracket for street light fitting made out of 40 mm bore pipe light grade GI tube 1.2 Meter length bent to shape required, fixed with and including MS flat iron clamps, bolts, nuts, washers duly painting the bracket with two coats of aluminium paint over a coat of zinc chrome primer complete.
Supply, laying and testing of LT UG cable, XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following sizes complete all as specified and directed including dismantling old defective one. Note: Earth work ( Excavation, Returning & refilling and removal), sand cushioning , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Sch 'A'.
16 Sqmm 4 core
10 Sqmm 4 core
Removing existing 1100 volts grade, XLPE, armoured, electric power cables (heavy duty) with aluminium conductor of sizes 6 Sqmm 4 core to 16 Sqmm 4 core from trench/ duct/ pipe carefully for identifying the defects and relaying the same after rectification of defects complete all as directed. Note: Earth work ( Excavation, Returning & refilling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Schedule
Material, labour , testing & commissioning of straight through jointing kit, heat shrinkable type suitable for XLPE/ PVC cables of size 6 to 16 Sqmm 3.5/4 core with working voltage 1100 volts make: Denson/ M Seal.
Material, labour , testing & commissioning of cable end termination in door/out door, heat shrinkable type suitable for XLPE/ PVC cables of size 6 to 16 Sqmm 3.5/4 core with working voltage 1100 volts
Supply and erection in vertical position Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws, type 410 SP-31 (9.00 metres long) all as specified duly factory painted with two coats of black bituminous paint internally through out and externaly for embeded portion and painting with one coat of red oxide primer, applying two coats of synthetic enamel aluminium paint on remaining exposed surfaces after errection complete, painting with synthetic enamel paint of colours black and yellow alternate strips of 30cm width upto 1.5 mtr from the top of coping complete including making suitable holes where required all as specified and directed .Note : PCC in foundation, coping, Earth work ( Excavation, Returning & refilling and removal) will be measured and paid separately under relative items of Schedule
Supply and fixing timelite distribution boards (street light DBs) 40 A 3 pole with 230 V Astronomical time switch suitable for operation on 415V 3 Phase AC supply with IP-54 complete all as directed including dismantling old one .
S&F loop-in/loop-out box of internal size 250x210x115 mm made out of FRP(Hot moulded type) with weather proof canopy and locking screws along with with 5/6 Amps MCB - 01 No, 50 Amps rated 3 pole connector- 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector etc complete in the box, duly fixed to to steel tubular/rail/PCC/RCC pole using 25 x 3mm FI clamp, including suitable gland and lugs for connecting cable complete all as directed including dismantling old one.
Dismantling steel poles/ struts, any size including transportation and stacking complete all as directed.
Laying only old bricks retrieved from relevant items of schedule of any size/type laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
Dismantling old unserviceable fittings and Supply & fixing Solar smart intergreted Solar LED Street light fitting (All in one type) with built in Mono Crystalline Panel, lithium ion battery (LiFePO4), MPPT charger controller, PIR sensor with colour temp 600-6500 K with minimum 40 W capacity LED light fittings with hybrid switch, Mono crystalline solar panel of capacity 48W+ 4W (mono), PIR sensor, IP65, 12.8V, 27 Ah lithium ion (LiFePo4) battery inbuilt in fitting, MPPT charge controller with efficiency > 90%, CRI > 70, autonomy for minimum 2 days, charging time 1 day, suitable for working temperatures -10 Degree C to +55 Degree C, fixed on 9.0 meter steel tubular pole/RCC pole complete all as directed & specified.Note : The rate is inclusive of fitting, battery, controller etc complete. The GI pipe bracket along with clamps, steel tubular pole and PCC foundation will be measured and paid separately.
Supply, installation and testing of solar Water Heating system at 60 degree C (Average) temperature, comprising of : (a) Flat Plate collector(as per BIS 12933),01 No for each system of 300 LPD with heating electric backup (b) Stand for the collectors (c) Hot water tank (SS-304) TIG welded with PUF insulation & Stainless Steel Outer cladding (d) Stand for hot water Tank (e) Hydraulic steam hose pipe with with check nut (f) Air vent 1 No for each system Note: The angle iron supports for solar stand will be measured and paid separately under relevent schedule items.
S&F triple layered Rotational moulded polyethylene water storage tanks of capacity 500 Ltrs (cylindrical vertical with closed top) hoisted and fixed in position all as specified with complete T&P for errection and installation all as directed .
S&F Hot water pipe duly insulated with glass wool and aluminium cladding of size 25 mm bore.
S&F Hot water pipe duly insulated with glass wool and aluminium cladding of size 20 mm bore.
S&F Hot water pipe duly insulated with glass wool and aluminium cladding of size 15 mm bore.
S&F Ball Polythene valves high pressure with polythene float and flynut complete, screwed for iron pipe or ferrule at any position and description of 25 mm bore size all as specified and directed by Engr-in-charge.Make: Prayag/Polytuf
M&L for PCC 1:2:4 type B1 20mm graded stone grade aggregate for the bottom basement layer of the solar stand/water tank stand or any other indicated positions complete all as directed.
M/L for solar panel/Solar water tank stand made by fabricated MS steel (angular iron, channel, flat,nut & bolts etc) including welding, reverting jointing and bending of any shape including two coat of enammel paint and one coat of red oxide paint as directed by Engineer-in Charge.
Supply and fix Water heater storage type, electric,capacity 25 litres.BEE 5 star rated suitable for 8 bar pressure with nano polymer coated tank, incoloy heating element,rust proof ABS body etc complete all as specified.
Supply and fixing sheet metal enclosure single pole and neutral with a 2 pin and earth plug and socket 20 A 240V complete with one single pole MCB of capacity 20 A complete all as specified and directed.
Supplying and laying of PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified.
S&F angle /stop valve , cast copper alloy screwed down high pressure with handle screwed both ends for iron pipe or for union of 15 mm dia of ISI Marked.
S&F bib taps cast copper alloy with capstan head CP screwed down high pressure, with or without lettered Hot or Cold of size 15mm dia of ISI Marked.
Supply & Fixing for distribution board iron clad, double door with IP-54 1K-09 protection suitable for MCCB as incomer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar and neutral link complete including with one MCCB 4 pole 415 Volts 100 Amps rating with rupturing cap 16 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site and as directed. Note : The quoted rate inclusive of cutting of cement concrete/brick wall for dismantling old one and making good the disturbed surfaces complete.
Supply & Fixing for sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 8 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification . Note : The quoted rate inclusive of cutting of cement concrete/brick wall for dismantling old one and making good the disturbed surfaces complete.
Supply & Fixing MCB single pole 240 volts any rating from 6 to 32 amps, with rupturing capacity 10 KA,C curve type, including providing thimbles for out going cables.
Supply & Fixing for MCB SPN 240 volts any rating from 20 to 32 amps, with rupturing capacity 10 KA,C curve type, including providing thimbles for out going cables.
M & L for submain wiring with two single core FRLS PVC insulated flexible copper conductor cable of size 4 sqmm and one single core FRLS PVC insulated flexible copper conductor cable green colour of size 4 Sqmm as earth lead in and including concealed PVC conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed. Note : The quoted rate inclusive for the following :- (a) Proper colour coding is to be followed as per IS Specification. (b) Test certificates of cables to be submitted before commencement of work/ claiming for payment.(c) wiring shall be concealed/ on surface with rigid PVC conduit medium grade as per site requirement.(d) Electric Wiring test sheet before and after completion of wiring to be submitted before claiming payment.
M & L for submain wiring with two single core FRLS PVC insulated flexible copper conductor cable of size 6 sqmm and one single core FRLS PVC insulated flexible copper conductor cable green colour of size 6 Sqmm as earth lead in and including concealed PVC conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed. Note : The quoted rate inclusive for the following :- (a) Proper colour coding is to be followed as per IS Specification. (b) Test certificates of cables to be submitted before commencement of work/ claiming for payment.(c) wiring shall be concealed/ on surface with rigid PVC conduit medium grade as per site requirement.(d) Electric Wiring test sheet before and after completion of wiring to be submitted before claiming payment.
Supply, laying and testing of LT UG cable, XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of sizes 35Sqmm 3.5 Core complete all as specified and directed. Note: Earth work ( Excavation, Returning & refilling and removal), sand cushioning , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Sch 'A'.
Sch of Credit = 69125.00
Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.
satpal and brothers
star india engineers
kailu construction co
Havish Construction
M/S Vijay Punj Constructions
SATISH AND CO
AV ENTERPRISES
Vijay Kumar Contractor and Engineers
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .