Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
Closing Date
19 Mar 2021, 3:00 pmClosed
Executive Engineer
CHMD (East), PWD, GTBH Complex Delhi
Provision make as per fire safety norms in Dr. Hedgewar Arogya Sansthan, Karkardooma, Delhi including fire check door and replacement of fire overhead tank after inspection of fire officer.
2021_PWD_201345_1
57/EE/BPD B-221(N)/CHMD(East)/2020-21
Open Tender
Civil Works
Works
120 days
CHMD (East), PWD, GTBH Complex Delhi
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
Exempted
25 Mar 2021
10 Mar 2021
19 Mar 2021
10 Mar 2021
19 Mar 2021
10 Mar 2021
Amount
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
Cement mortar 1:6 (1 cement : 6 coarse sand)
Marble work gang saw cut (polished and machine cut) of thickness 18 mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade (To be secured to the backing by means of cramps, which shall be paid for separately), Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble
Area of slab upto 0.50 sqm
Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to be paid for separately)
Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge (panneling to be paid for separately).
Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. Sheet (Zinc coating not less that 120 gm/ m2) of size 20 33 mm screwed with M4 x 38 mm SS Screws at distance 75 mm from the edges and 150 mm c/c, including applying a coat of approved fire resistant primer/ powder coating of not less that 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3): 2016 and as per direction of Engineer-in-charge with glass of required thickness having 60 minutes of fire resistance both integrity & radiation control (EW 60) and minimum 20 min. of insulation (EI 20). The manufacturer have to give test report/ certification of fire glass and the glass should have the stamp showing the value of E, EW & El. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/ IEC 17011 and accredits labs as per ISO/ IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100 x 2200 mm (w x h) or 2.42 sqm.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of
20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with ecommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- Part I
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening“for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required.
Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK
15 mm cement plaster on rough side of single or half brick wall of mix:
1:6 (1 cement: 6 coarse sand)
Providing and applying two coats of fire retardant paint on cleaned wood / ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendations of manufacturer to make the surface fire retardant
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.
Two coat
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
In cement mortar
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
Of area beyond 3 sq. metres
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead :
Of area 3 sq. metres and below
Of area beyond 3 sq. metres
Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
Granite work gang saw cut (polished and machine cut) of thickness 18mm for wall lining (veneer work), backing filled with a grout of average 12mm thick in cement morta 1:3 coarse sand), including pointing with white cement mortar 1:2 (I white cement:2 marble dust) with an admixture of pigment to match the marble shade (To be secured to the backing by means of cramps, which shall be paid for separately). area of slab over 0.50 sqm
Refixing of existing fire door i/c frame with necessary accessories on the location decided by engineer-in-charge.
Supply and fixing of 2nd class teakwood door frame with 02 nos. heat activated intumescent fire seal strip of section 10 mm x4 mm. The frame shall be painted with fire retardant primer FR880 type. The frame shall be fixed in existing opening with the help of stainless steel hold fasteners of 10mm x 160 mm size as per direction of Engineer-in-charge. The door frame shall be minimum 2 hours fire rating (fasteners paid separately). a) Door frame of section 145 mm x 90 mm
Providing and fixing 50 mm thick wooden fire rated doors as per BS: 476 Part-20 & 22 & IS 3614 part-1 & part-2 for stability, integrity and thermal insulation (3 criteria wooden door) with the following specification. Fire door should be tested at CBRI for fire rating of 2 hrs. Fully insulated fire door shutter shall be comprising of 70mm z 44mm hardwood internal timber frame work consisting of 2 vertical members and minimum 4 horizontal members, with infill of 20 mm thickness of 48 kg/cum, ceramic fiber blankets, coated on both side for insulation. The coated insulation shall be sandwiched between 12 mm thick, calcium Silicate Boards on both sides (edge to edge on internal Hardwood frame) and facing with 3 mm commercial ply (BWP) ply on both sides, with 50 mm x14 mm teak beading 20 x 4 mm fire & smoke intumescent seal complete as per direction of Engineer-in-charge. a) 1070 mm x2050 mm
Supply and fixing of interlayer fire rated glass minimum 11 mm thick interlayer, 120 minutes fire rated (EW120, EI 15 minutes) Non wired, Toughened interlayer glass of approved make which can also withstand thermal shock up to 800 degree centigrade in glazing (Vision Panel top/side fixed glazing) to be fixed in between the glass beading by using ceramic fiber in accordance with BS: 476 PART 22/EN 1363 EN 1364 for stability and integrity of size 300 mm x 500mm (clear vision)
Providing and fixing two hours fire rated, 304 grade stainless steel touch type panic exit device double leaf type of approved make as approved by Engineer-in-charge including accessories etc complete in fire rated door.
Providing and fixing two hours fire rated, 304 grade stainless steel panic trim (outside access device ) used with panic exit device of approved make as approved by Engineer-in-charge including accessories etc complete in fire rated doors.
Providing and fixing 304 grade stainless steel ball bearing butt hinges of size 100x75x3 mm in fire rated door shutters of approved make, approved by Engineer-in-charge including stainless steel screws etc. complete as per direction of Engineer-in charge.
Providing and fixing pair of stainless steel 304 grade ‘D’ type pull handle of size 300 m long and 22 mm dia back to back, of approved brand, as approved by Engineer-in-charge including.
Providing and fixing batwing seal of Lorient or equvalent as approved by the Engineer-in-charge for door frame for double leaf door set as per IS 1212, automatic drop seal for bottom of the shutter as per IS 8010 and for double leaf shutter as per IS 7061.
Provding and fixing fire rated hydraulic door closer of make Dorma Bechker FS, GEZE or equivalent with necessary accessories and screws etc. complete.
Providing and fixing ISI marked Stainless Steel tower bolt black finish, (Barrel type) with necessary screws etc. complete : 300x10mm
Providing and fixing ISI marked Stainless Steel sliding door bolts with nuts and screws etc. complete : 300x16mm
Providing and fixing, assembling GRP SMC panel tank of required dimentions & capacities with Access entry cover, including cutting making holes in tank for inlet & out let complete for all lead & lift as per direction of engineer-in-charge.
Credit for dismantiled material to be taken by Agency as and where basis.
Wooden Door shutter
Steel Door
SMC panels of damaged tank
Credit of Old dismantled brick.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .