Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.2 LQualified Make: PARADYNE
Model: paradyne 1.0 kva 168 vah 40A 8 I ST FLOOR ASHOK NAGAR NEW DELHI DELHI 110018 UDYAM DL 11 0006731 | WEST DELHI | DELHI | 110018 | Make: PARADYNE
Model: paradyne 1.0 kva 168 vah | L1 | Qualified | |
| 2 | L2₹1.2 L+₹3,030 (2.53%)Qualified Make: microtek
Model: UPS TGE PRO 100+ C 305 MANUBHAI TOWER OPP COMMERCE COLLEGE SAYAJIGUNJ VADODARA GUJARAT 390005 UDYAM GJ 24 0040300 24AARFS2191R1ZC R M | VADODARA | GUJARAT | 390005 | Make: microtek
Model: UPS TGE PRO 100+ | L2 | Qualified | |
| 3 | L3₹1.3 L+₹9,030 (7.53%)Qualified Make: LUMINOUS
Model: Luminous UNO 1000 1 KVA ALIGANJ LUCKNOW 2845 226024 INDIA | LUCKNOW | UTTAR PRADESH | 226024 | Make: LUMINOUS
Model: Luminous UNO 1000 1 KVA | L3 | Qualified | |
| 4 | L4₹1.5 L+₹27,030 (22.5%)Qualified Make: Eaton
Model: Eaton Aurora 1000VA UPS PLOT NO 839 BASEMENT SHALIMAR GARDEN EXTN I SAHIBABAD GHAZIABAD UTTAR PRADESH 201005 | GHAZIABAD | UTTAR PRADESH | 201005 | Make: Eaton
Model: Eaton Aurora 1000VA UPS | L4 | Qualified | |
| 5 | Disqualified Make: zebronic
Model: zebronic) (Zebronics UPS ZEB-U1200) 2 SHAH MARKET KATPIECE GALI BOMBAY BAZAR KHANDWA MADHYA PRADESH 450001 | EAST NIMAR | MADHYA PRADESH | 450001 | Make: zebronic
Model: zebronic) (Zebronics UPS ZEB-U1200) | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
17 Jul 2018, 11:00 amClosed
Line Intractive UPS with AVR Average Turn Over of Last 3 Years 20 Lakh (s) Experience with Gov. Required 3 Year (s) Line Intractive UPS With AVR ( 30 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/168 1.0/168 Technology MOSFET-PWM MOSFET-PWM
IGBT- PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 Rated Output (Volt) Single phase sinewave 230v AC
50Hz Single phase sinewave 230v AC
50Hz
Single Phase Quasi-Sin-wave 230 V AC
50 Hz Degree of protection IP 20 IP-21
IP 20 Inverter Efficiency (%) >/= 60% >/= 60%
>/= 70% Warranty for the battery from the date of delivery 1 year - Warranty for Line Interactive UPS 1 Year 1 Year
2 Years
5 Years Installation and commissioning instructions No - 1/4 CONSTRUCTIONAL Type of enclosure ABS - AC out put for printer (not through inverter) Yes Yes
No Inverter out put socket AC out put for printer (not through inverter) 3 Three pin 2 Three pin
3 Three pin
Hard wiring
Not applicable FUNCTIONAL Total harmonic distorsion (%) </= 40% - Input (Volt) Single phase sinewave(160-280v) - Switching over time (Mili sec) Maximum 10 milli seconds - Overload Time (Minutes) >/= 10 minutes - Load power factor >/= 0.6 - Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9%
50 +/-3 Hz - Overload (%) >/=10% - Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% - Variation on output frequency in battery mode (Hz) </=0.5 - PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 - Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts
the system shall switch over to battery mode Yes - Protection against short circuit of UPS Yes - Protection for over voltage and over load Yes - REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree
RH -95% for 2-cycle as per IS:9000 Yes - 2/4 pt-5/sec-1 Dry heat Test at 45 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Yes - Cold Test as per IS:9000 pt-2/sec-4 Yes - Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes - Type Test certificate no. and date 400079/01012018 - Name Of Lab NABL - Address of Lab NABL PANCHKULA HARYANA - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Rohit Tiwari 182101
COMMAND HOSPITAL UDHAMPUR 30 30 Required No ePBG Required No
283714
GEM/2018/B/40272
Line Intractive UPS with AVR
30 days
Jammu And Kashmir; Udhampur
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Line Intractive UPS with AVR Average Turn Over of Last 3 Years 20 Lakh (s) Experience with Gov. Required 3 Year (s) Line Intractive UPS With AVR ( 30 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/168 1.0/168 Technology MOSFET-PWM MOSFET-PWM | - | - | - |
| IGBT- PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 Rated Output (Volt) Single phase sinewave 230v AC | - | - | - |
| 50Hz Single phase sinewave 230v AC | - | - | - |
| 50Hz | - | - | - |
| Single Phase Quasi-Sin-wave 230 V AC | - | - | - |
| 50 Hz Degree of protection IP 20 IP-21 | - | - | - |
| IP 20 Inverter Efficiency (%) >/= 60% >/= 60% | - | - | - |
| >/= 70% Warranty for the battery from the date of delivery 1 year - Warranty for Line Interactive UPS 1 Year 1 Year | - | - | - |
| 2 Years | - | - | - |
| 5 Years Installation and commissioning instructions No - 1/4 CONSTRUCTIONAL Type of enclosure ABS - AC out put for printer (not through inverter) Yes Yes | - | - | - |
| No Inverter out put socket AC out put for printer (not through inverter) 3 Three pin 2 Three pin | - | - | - |
| 3 Three pin | - | - | - |
| Hard wiring | - | - | - |
| Not applicable FUNCTIONAL Total harmonic distorsion (%) </= 40% - Input (Volt) Single phase sinewave(160-280v) - Switching over time (Mili sec) Maximum 10 milli seconds - Overload Time (Minutes) >/= 10 minutes - Load power factor >/= 0.6 - Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9% | - | - | - |
| 50 +/-3 Hz - Overload (%) >/=10% - Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% - Variation on output frequency in battery mode (Hz) </=0.5 - PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 - Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts | - | - | - |
| the system shall switch over to battery mode Yes - Protection against short circuit of UPS Yes - Protection for over voltage and over load Yes - REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree | - | - | - |
| RH -95% for 2-cycle as per IS:9000 Yes - 2/4 pt-5/sec-1 Dry heat Test at 45 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Yes - Cold Test as per IS:9000 pt-2/sec-4 Yes - Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes - Type Test certificate no. and date 400079/01012018 - Name Of Lab NABL - Address of Lab NABL PANCHKULA HARYANA - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Rohit Tiwari 182101 | - | - | - |
| COMMAND HOSPITAL UDHAMPUR 30 30 Required No ePBG Required No | - | - | - |
Exempted
17 Jul 2018
3 Jul 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_283714.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .