Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.5 LAccepted-AOC HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹12.2 L+₹72,614.81 (6.33%)Rejected-Finance | L2 | Rejected-Finance not lowest |
Tender Value
₹16.2 L
EMD Value
₹32,420
Closing Date
12 Sept 2024, 6:00 pmClosed
GARRISON ENGINEER ABOHAR
GARRISON ENGINEER ABOHAR PIN 152116
PROVN OF SERVO VOLTAGE STABILIZER TO NFS NODE OF SIGNAL CENTRE AND PROVN OF HIGH MAST SECURITY LIGHT NEAR BN MAG OF INF BN-I AT MIL STN ABOHAR.
2024_MES_665794_1
TOKEN NO GE ABH-31/24-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
ABOHAR MIL STN
AS PER NIT
7 documents required · 7 mandatory
₹500
GE ABOHAR
₹32,420
Yes
1 Jan 2025
13 Jul 2024
14 Sept 2024
13 Jul 2024
12 Sept 2024
27 Jul 2024
Amount
Supply & install, commissioning, testing of Servo voltage stabilizer copper winding for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V 480 V with output voltage stabilized at 415 volt with accuracy ± 2.5% and speed of correction 8 volt per second and of capacity 100 KVA including provision of by arrangement to switching complete all as specified and directed
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3½ core including provision of LT cable path indicator CI round shape mentioning LT cable of Blue color paint fixed with 0.75 Mtr length angle iron of size 40x40x4 mm laying intervals 20 Mtr and refer laying of cable shall be compile with SSR Part -I Section 19.75.1 Note: Cable path indicators and end termination joints with aluminium lugs/thimbles deemed to include with quoted rates
Supply & install, commissioning, testing of out door type feeder pillar, LT type (CPRI approved) of size 1.0 mtr x 1.0 mtr x 0.6 mtr fabricated out of 3.15mm thick CRCA sheet angle size 50 x 50 x 5 mm thick frame factory made totally enclosed dust and vermin proof are side hinged opening arrangement on front and back with weather proof canopy of top with locking arrangement, cable entry and exist from bottom both side i). INCOMING: a) MCCB 160 A,415 Volts 4 pole, 50 KA-(Adjustable Thermal Magnetic protrction) b) Indicator lamp LED type (set of three Red,Yellow,Blue) ii) OUTGOING c) MCCB 125 A,415 Volts 4 pole 36 KA(Adjustable Thermal Magnetic protrction)-01 No d) MCCB 100 A,415 Volts 4 pole 36 KA(Adjustable Thermal Magnetic protrction)-01 No e) MCCB 63 A,415 Volts 4 pole 36 KA, -01 No f) MCB 40A,230 Volts 2 pole 16 KA, DP-01 No g) Aluminium bus 250 A, 40mmx6mmx reqd length-04 nos (h) Digital Volt meter & Ammeter with suitable CT's each set Note:- (i) All types of spares such as glands, lugs, bolts etc, necessary excavation and earth work, PCC work and making good the disturbed surfaces shall deemed to be included in the quoted rate. (ii) Drawing of panel shall be approved before fabrication be GE.
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to galvanised iron earth strip 32x6 mm thick fixed by means of bolts, nuts and washers and watering pipe 20mm dia GI medium grade with socket and plug 30 cm above ground level including earthwork, PCC chamber in PCC (1:3:6) type C-2 using 40mm stone aggregate, cast iron cover, wire mesh etc all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete and all as specified and direcrted by Engr-in-charge Notes :- (i) 20 mm dia GI pipe medium grade for watering to be provided with a socket and plug and should be 30 cms above ground level. (ii) GI strip connecting upto panel and DBs earth connection is included in this item. (iii) GI pipe 40 mm dia protection pipe shall be provided upto Ground level.
M&L for Earthing for Panels complete with galvanized steel plate electrode of size 600x600x6.3mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanized iron earth strip of size 25 x 4mm earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed.
M&L for PCC preparation including cutting up to 45 cm width and depth of the road/hard standing and making good disturbed surfaces by using PCC type C2(1:3:6) by using 40mm graded stone aggregate for the fixing the pipe/laying cables complete all as specified.
M&L for 80mm dia steel tubes (light grade) galvanised with fittings, laid in trenches/wall for protection of underground earth strip when crossing the road/fixing on wall as in repair complete all as specified and directed.
Supply and fixing RCCB of 4 pole 63 Amps rating with sensitivity of 30 mA suitable for 415 volts
M&L for submain wiring comprising single core, 4 Runs of 16 sqmm nominal cross sectional area multimultistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. PVC conduits and conduit fittings/existing concealed PVC conduit and conduit fittings not less than 40 mm dia complete, including provision of 2x16 sqmm nominal cross sectional area multimultistranded copper conductor cable PVC insulated unsheathed 1100 Volts grade as earth wire and using color code as per IS and specified and making good all disturbed work to match the existing complete.( Note :- Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly)
Excavation in trenches any type of soil , n exc 1.5m wide and n exc 1.5m in depth , for foundation , etc or for shaft, well, cesspits , manholes , pier hole etc n exc 1.5 m in depth and getting out for laying of cable complete all as specificed and directed.
Returning , filling in including, spreading , levelling , watering and well reamming in layers not exc. 25 cm within the 1 mtr strech complete all as specificed and directed.
Removing excavated material n exc 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specificed and directed.
M & L for sand cushioning with dry coarse sand to under ground cable 23 cm thick, 8 cm thick below the cable and 15 cm thick after laying the cable complete all as specified and directed by Engineer-in-Charge. Note : Thickness after punning shall be considered for payment.
Supplying and laying reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm complete all as specified anddirected.
M&L for construction of plateform suitable for 100 KVA stablizer of size 2X1.5 m with 2 feet (clear height with additional 150 mm thick PCC 1:3:6 type C-02 using 40mm graded crushed stone aggregates as in foundation below after that 23 cm wide brick masonry in CM 1:6 Below & Above ground level , hollow space to be filled hard core of size not exceeding 63 mm, deposited spread and levelled in layers not exceeding 15cm thickness, watered and well rammed with 100 mm thick cement concreate 1:2:4 type B-2 as in Fllor/Top of Platform, brick surface plastered with CM 1:4 complete all as specified and directed.
S&F Galvanized steel High Mast of 16 Mtrs height lighting system in two section, 3 mm section thickness, top dia not less than 150mm & bottom dia not less than 340 mm with its accessories including foundation bolts manufactured from special steel and Hot Dip Galvanised along with nuts, washers, anchor plates and templates, feeder pillar panel control and raising & lowering mechanism for integral power tool, Twin aviation Lamp etc. Mast shaft shall be in two sections, hot dip galvanized and suitable for wind velocity as per IS 875 part 3 minimum 180 km per hour. It shall also include accessories for high mast including head frame, steel wire rope (7/19 construction) double drum which is operated by motor gear mechanism with inbuilt starter, Galvanized Lantern carriage arrangement 'suitable for 08 Nos.luminaires Symmetrically & its control gear boxes and with 03 point suspension system. The mast shall have an integral power tool installed inside the base compartment for its operation. ( Material construction of high mast sheet will be of BSEN 10025 / IS 5986 or equivalent ). with wiring cable for luminaire connection including suitable size of foundation for 16.0 mtr high mast considering the soil bearing capacity 10 T / Sq. mtr at 2 meter depth and using RCC M-25 grade (design mix) concrete with reinforcement,form work,earthwork complete all as per manufacturers instructions and as directed by Eng-in-charge. Note:- a) Making of civil foundation for erection of high mast and feeder pillar panel as per manufacturer recommendation demeed to be included in the unit rate. b) Cable of required size and length from top to bottom for connection of LED flood light an related switchgears included in above quoated rate.
Supply and fixing LED flood light fittings with and including lamp 200W rating, separate individual peanut plated Lens housing should be made of LM6 Pressure die Cast Aluminum . Optical cover should be only Toughened Glass only, IP Protection not less than IP 66, Protection should be Class I,Product Standard IS 10322/IEC 60598, Driver Operating Voltage should be 140 V-270V, Driver Frequency 50Hz, Power Factor>0.9, Lumen output should not be less than 100 Lumen/watt and Luminaries with separate external surge protection device 4 Kv to 10 kv rating and separate connector block for termination of incoming cable connection all as specified and directed. Make - Catpart no- LFSMD-200C of Orient or equivalent in Crompton/Bajaj
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth for taking out/for laying under ground cables/pipes etc and getting out any type soil complete all as directed
Returning filling in including spreading, levelling, watering and well ramming in layers n-exc 25 cm complete all as directed.
Removing excavated soil to a distance n-exc 50 mtr and depositing where directed at a level n-exc 1.5 mtr above the starting point complete all as directed.
Supply and spreading sand cushioning with coarse sand to under ground cable 23 cm thick 8 cm thick below the cable and 15 cm thick after laying the cable complete all as directed.. Note : - Only punned thickness shall be measured for payment purpose
Supply and lay rainforced precast concrete cable cover class LV, type I, falt, size 250mm x 150mm x 40mm complete all as directed.
Boring of holes under road, pavement, hard standing by trenchless technology technique for 40-80 mm dia pipe all as specified and as directed.
M&L for GI pipe light grade of sizes 40mm dia, ISI marked with all fitting for cable protection, laid in trenches, under road or fixing on wall/pole/ crossing nallah etc all as specified and as directed.
Supply, laying and testing LT XLPE cable Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directed
M & L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, earth plate surrounded by 15cm thick and packed layer of charcol dust and common salt connected to galvanised earth strip 32x6mm GI strip by means of bolts, nuts, check nuts and washers watering pipe 20mm dia GI medium grade with socket and plug 30cm above ground level including earth work PCC chamber in PCC (1:3:6) type C-2 using 40mm stone aggregate cast iron cover wire mesh all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as directed.
P.K ENTERPRISES (BID ID -3085462)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .