Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 CrAccepted-AOC SIBAL NIWAS BAGADGANJ POST OFFICE NAGPUR 440008 | NAGPUR | NAGPUR | MAHARASHTRA | 440008 | ₹8.7 Cr | L1 | Accepted-AOC Lowest bid found in order |
| 2 | L2₹9.3 Cr+₹61.4 L (7.04%)Rejected-Finance 14 KISHANGARH WEST IDGAH AGRA 282001 | AGRA | UTTAR PRADESH | 282001 | ₹9.3 Cr+₹61.4 L (7.04%) | L2 | Rejected-Finance Other than lowest bid |
| 3 | L3₹9.7 Cr+₹98.5 L (11.3%)Rejected-Finance 2ND FLOOR 9 EZRA STREET KOLKATA WEST BENGAL 700001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | ₹9.7 Cr+₹98.5 L (11.3%) | L3 | Rejected-Finance Other than lowest bid |
| 4 | L4₹9.8 Cr+₹1.1 Cr (12.1%)Rejected-Finance JODHPUR ROAD UTARLAI BARMER RAJ 344035 | BARMER | RAJASTHAN | 344035 | ₹9.8 Cr+₹1.1 Cr (12.1%) | L4 | Rejected-Finance Other than lowest bid |
| 5 | L5₹10.0 Cr+₹1.3 Cr (15.0%)Rejected-Finance | ₹10.0 Cr+₹1.3 Cr (15.0%) | L5 | Rejected-Finance Other than lowest bid |
| Sl No | Description | Qty | Unit | JASPAL SINGH & CONST L2 | surendra infrastructure pvt ltd L3 | AMIT ASSOCIATES L8 | M/s Matadeen Ramchandra Agarwal L6 | SIBAL AND SIBAL L1 | K R TRADERS L5 | RAMJI DAS DHAL CONSTRUCTION PVT LTD L9 | M/s godara infratech and power industries L4 | A.B. Projects Pvt. Ltd. L7 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00SCHEDULE A PART I (BUILDING WORKS) | ||||||||||||
| 1.01 | Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ Part I . | 1 | Lump Sum | 7,20,22,543.84 ₹7,20,22,543.84 | 7,57,00,000 ₹7,57,00,000 | 8,95,82,725 ₹8,95,82,725 | 7,75,00,000 ₹7,75,00,000 | 6,76,43,235 ₹6,76,43,235 Lowest | 7,75,00,000 ₹7,75,00,000 | 8,91,25,000 ₹8,91,25,000 | 7,50,00,000 ₹7,50,00,000 | 8,32,15,000 ₹8,32,15,000 |
| 2.00Sch A Part II (INTERNAL WATER SUPPLY WORK) | ||||||||||||
| 2.01 | Lump sum price worked out by the contractor for Internal Water Supply work as listed in Sch ‘A’ Part II. | 1 | Lump Sum | 4,50,057.79 ₹4,50,057.79 | 3,50,000 ₹3,50,000 | 4,17,550 ₹4,17,550 | 4,24,879.74 ₹4,24,879.74 | 3,37,481 ₹3,37,481 Lowest | 4,24,879.74 ₹4,24,879.74 | 4,31,250 ₹4,31,250 | 4,50,000 ₹4,50,000 | 4,44,180 ₹4,44,180 |
| 3.00Sch A Part III (INTERNAL ELECTRIFICATION WORK) | ||||||||||||
| 3.01 | Lump sum price worked out by the contractor for Internal Electrification work as listed in Sch ‘A’ Part III . | 1 | Lump Sum | 19,53,385.09 ₹19,53,385.09 | 21,00,414.08 ₹21,00,414.08 | 29,89,845 ₹29,89,845 | 22,00,000 ₹22,00,000 | 16,96,507 ₹16,96,507 Lowest | 23,10,455.49 ₹23,10,455.49 | 25,87,500 ₹25,87,500 | 23,00,000 ₹23,00,000 | 30,08,523 ₹30,08,523 |
| 4.00Sch A Part IV (EXTERNAL WATER SUPPLY WORK) | ||||||||||||
| 4.01 | Lump sum price worked out by the contractor for External Water Supply work as listed in Sch ‘A’ Part IV | 1 | Lump Sum | 2,76,065.19 ₹2,76,065.19 | 2,25,000 ₹2,25,000 | 2,22,010.47 ₹2,22,010.47 | 2,31,663.1 ₹2,31,663.1 | 2,16,663 ₹2,16,663 Lowest | 2,41,315.73 ₹2,41,315.73 | 2,58,750 ₹2,58,750 | 2,50,000 ₹2,50,000 | 3,35,775 ₹3,35,775 |
| 5.00Sch A Part V (EXTERNAL ELECTRIFICATION WORK) | ||||||||||||
| 5.01 | Lump sum price worked out by the contractor for External Electrification Work as listed in Sch ‘A’ Part V. | 1 | Lump Sum | 14,01,151.81 ₹14,01,151.81 | 14,00,000 ₹14,00,000 | 13,45,865 ₹13,45,865 | 14,40,436.44 ₹14,40,436.44 | 14,69,638 ₹14,69,638 | 14,40,436.44 ₹14,40,436.44 | 17,25,000 ₹17,25,000 | 12,50,000 ₹12,50,000 Lowest | 16,84,551 ₹16,84,551 |
Tender Value
Refer Docs
EMD Value
₹8.0 L
Closing Date
27 Sept 2025, 6:00 pmClosed
CEAF Prayagraj
HQ CEAF Prayagraj
PROVN OF DSC MESS ALONGWITH LIVING IN ACCOMODATION AT NEW LOCATION OF AF STN SONEGAON
2025_MES_722664_1
958457/E8
Open Tender
Civil Works
Lump-sum
540 days
Sonegaon
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
Yes
AGE(I) (AF) Sonegaon
₹8.0 L
Yes
26 Nov 2025
25 Jul 2025
4 Oct 2025
25 Jul 2025
27 Sept 2025
13 Sept 2025
Amount
SCHEDULE A PART I (BUILDING WORKS)
Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ Part I .
Sch A Part II (INTERNAL WATER SUPPLY WORK)
Lump sum price worked out by the contractor for Internal Water Supply work as listed in Sch ‘A’ Part II.
Sch A Part III (INTERNAL ELECTRIFICATION WORK)
Lump sum price worked out by the contractor for Internal Electrification work as listed in Sch ‘A’ Part III .
Sch A Part IV (EXTERNAL WATER SUPPLY WORK)
Lump sum price worked out by the contractor for External Water Supply work as listed in Sch ‘A’ Part IV
Sch A Part V (EXTERNAL ELECTRIFICATION WORK)
Lump sum price worked out by the contractor for External Electrification Work as listed in Sch ‘A’ Part V.
Sch A Part VI (SEWAGE DISPOSAL WORK)
Lump sum price worked out by the contractor for Sewage Disposal Work as listed in Sch ‘A’ Part VI.
Sch A Part VII (AREA DRAINAGE WORK )
Lump sum price worked out by the contractor for Area Drainage Work as listed in Sch ‘A’ Part VII
Sch A Part VIII (ROAD/ PATH WORK)
Lump sum price worked out by the contractor for Road / Path Work as listed in Sch ‘A’ Part VIII
Sch A Part IX (SITE CLEARANCE AND EARTH WORK)
Lump sum price worked out by the contractor for Site clearance and Earthwork as listed in Sch ‘A’ Part IX
Sch A Part X (SUMMER APPLIANCES WORK)
Lump sum price worked out by the contractor for Summer Appliances work as listed in Sch ‘A’ Part X
Sch A Part XI (HOT WATER SUPPLY WORK )
Lump sum price worked out by the contractor for Hot Water Supply work as listed in Sch ‘A’ Part XI
Sch A Part XII (Miscellaneous Items of B/R and E/M etc)
M&L for Double Wall Corrugated pipe, made of HDPE (High-Density Polyethylene) and feature a smooth inner surface and a corrugated (wavy) outer surface (SN8) pipes of 200mm (Outer Diameter) / 175mm (Inner Diameter) laid in trenches and jointed complete all as specified and as directed.
Construction of Septic Tank for 100 users with brick masonary wall, PCC in foundation floor, cover slab including sludge chamber, Cast Iron Vent pipe, Cast Iron cowl, inlet and outlet pipe, RCC bafle wall with all necessary earth work in any type of soil complete all as specified and as shown in Drawing.
Construction of Soakage wells of size 3.6m dia and 4.5m effective depth, including excavation in any type of soil, having PCC foundation (1:3:6), honey combed masonary walls with top ring constructed of M25 concrete including intercepting chamber and screen chamber constrcuted of Brick Masonary in cement mortar with RCC Cover slab of M25 Concrete/ SRFC cover and interconnecting pipes of RCC/DWC, completely filled with brick bats complete all as specified and as directed.
S & F wall mounted type LED light fitting batten type complete with LED 1x 10 watt (2 feet long), extruded aluminium body with heat sink provided for efficient heat dissipation and integrate electronic drive complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable complete all as specified and as directed.
Supply, Installation, testing and Commissioning of CPRI tested, factory made, totally enclosed, IP 54 dust, weather and vermin proof, LT Panel outdoor type KIOSK for 415V, 3 phase 4 wire, 50 Hz AC system made out of CRCA steel sheet 3.15 mm thick with TPN tinned copper bus bar of rating 1.5 times that of controlling MCCB supported on F class DMC/FRP insulator with short circuit withstand capacity 21 MVA for 1 second, neutral bus bar of capacity of that of phase bus bar, general construction confirming to IS-8623/93, having bottom base channel of MS section not less than 75mm x 75 mm x 5 mm, entire panel having common aluminium earth bar of size 25mm x 5mm at the rear with 2 Nos earth stud, solid connection from main bus bar to switchgears with required size ( minimum 1.5 Sqmm) PVC insulated copper conductor cable, cable alloys, cable gland plates in two half including LED indicating lamp for all phases and, mounted on suitable size of PCC foundation for the complete panel base with following accessories:- (A) Incoming (i) MCCB, 4 Pole, 250A, fixed thermal and magnetic setting, Ics=100%Icu, 35 KA with copper extension link. (ii) Copper bus bar of rating 1.5 times of Main incommer. (iii) Digital panel meter for Amp, Volt, KWH, power factor and other parameter flush mounting of size 96 x96 mm. (iv) LED indicating lamps for RYB. (B) Outgoing (i) MCCB,100 A TPN, 415V, with rupturing capacity 16 KA - 02Nos (ii) MCCB,32 A TP, 415V, 16A with rupturing capacity 16 KA - 01 Nos (iii) MCCB,160 A TP, 415V, with rupturing capacity 16 KA - 01 Nos
Supply, fixing & testing LED street light fittings of 35 Watt, 230 V AC outdoor type with surge protector & high pressure Die cast aluminium housing and heat resistant complete with driver, lamp with impact and corrosion resistant including thermal management in multiple optics complete with IP66 protection with LED asymmetric for 35/36 watt 230V inclusive of LED lamp & suitable capacity of control gear box/driver and suitable flexible wiring with 0.5 sq mm PVC insulated copper cable through and including fixing on pole with suitable MS flat iron braket or GI pipe in angle complete all as specified and as directed.
S & F house service bracket made of GI Pipe bend to shape, 1.5 m (32/40mm dia as required at site) with two Nos clamps made out of 50x6mm flat and two Nos bolts with nuts duly grouted in wall or fixing on wall complete all as specified and directed.
S & F factory made epoxy powder coated distribution board VTPN DB 4 ways coniform to IS 8623-1, IEC-61439-1&3 metal double door, IP54 with acrylic top cover fabricated from CRCA sheet and fixed flush to wall and suitable for universal mounting and including with insulated vertical phase bus bars, neutral bar, stranded DIN rail, earth bar, colour coded interconnecting wire set and cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified & directed.
S & F factory made epoxy powder coated distribution board VTPN DB 6 ways coniform to IS 8623-1, IEC-61439-1&3 metal double door, IP54 with acrylic top cover fabricated from CRCA sheet and fixed flush to wall and suitable for universal mounting and including with insulated vertical phase bus bars, neutral bar, stranded DIN rail, earth bar,colour coded interconnecting wire set and cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified & directed.
Supply and fixing of steel metal enclosure, 2 way, double door, water proof, fabricated out of 3mm thick MS sheet, powder coated both inside and outside, for housing MCB & aluminium bus bar of size 20mm x 3mm of required length including MCB SPN 6 Amps for control of single street light fitting / post top lamp fixed on pole, enclosure to be fixed with suitable size of clamp, nut & bolt and washer fixed to pole complete all as specified and directed.
Supply and laying bricks (old size) for cable protection by using common burnt clay building bricks, sub-class ‘B’ designation 75 laid dry flat across length of the cable with width of the trenches equal to length of bricks complete all as specified and directed.
Supply, installation, testing and commissioning of single stage split casing centrifugal pump set for clear water capacity 5 HP (3.7 KW) not less than 369 LPM (Ltr / Min @ 30 Mtr head), mounted on base frame, Electric driven, 3 phase, 440 Volt, 4 Wire, 50 cycles, AC type, 1500 RPM with copper wound induction motor directly coupled including Cast Iron casing and impeller, CI260 (012) suitable size of Suction pipe and discharge pipe of sizes 80x80 mm (GI/DI/CI pipe), connection from sump to pumps & delivery to main header coupling guard, presssure gauges at delivery side, necessary numbers of sluice valves, air release valves, CI foot valves, Automatic star delta starter of suitable capacity / size and all accessories as recommended by manufacturer for PCC foundation and MS channel of suitable size, nut bolts and washers, vibration rubber pads complete all as specified and directed & consisting of following :- (a) Centrifugal Pump set Model No : UP 100/38, Split Case of Kirloskar or equivalent as specified in make list and Induction Motor of Make Kirloskar/Crompton or equivalent as specified in make list. Note : (a) PCC foundation, base frame and all other minor items shall be provided as per manufacturer instructions and complete all as specified and directed. Cost of the same shall be deemed to be included in quoted rates. (b) S&F ASD Starter of suitable size for LT panels, connecting cables from panels to pumps of 5 HP capacities pumps ( pump houses ) and complete all as specified .Tenderer are advised to inspect site before quoting the rates. (c) S&F suitable copper connecting cables from starter to induction motor.
S & F foot valve having cast Iron body, cast iron door, hinge pin NA, door facing rubber ) from UG sump 80 mm bore GI tubing with flange of PN 1.6 and lowering in sump and make good priming system complete all as specified and directed
S&F Ductile iron pipes with push on joints of Class - K9 & conforming to IS 8329 (centrifugally cast spun ductile iron pressure with spigot end with cement mortar lining inside) in any length for 150 mm bore pipe complete all as specified and directed :- NOTE :- Earth work, Joints and DI specials/ fittings of the pipes shall be measured and paid for separately under appropriate item of BOQ/Schedule `A'.
S&F DI fittings such as Bends, tappers, straight connecting piece, Tee pieces, either one side flanged and other socketed / both flanged / both socketed any type, radius and upto 450 mm bore including nut bolt, packing material etc and making the joint leak proof complete all as specified and directed.
M&L for construction brick masonry valve chamber of size 900mm x 900mm x 900mm (Internal dimension) with PCC foundation (1:3:6) of 150mm thick, brick work 230 mm thick built in cement mortar (1:6), PCC coping (1:3:6) 50 mm thick, 15mm thick plastering in cement mortar (1:4) to all internal and exposed surfaces including excavation of earthwork in any type of soil, MS sheet cover 3.15 mm thick fixed with angel iron frame 50x50x6mm with locking arrangement embedded in PCC and painting of MS cover with two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
M&L for construction brick masonry valve chamber of size 600mm x 600mm x 600mm (Internal dimension) with PCC foundation (1:3:6) of 150mm thick, brick work 230 mm thick built in cement mortar (1:6), PCC coping (1:3:6) 50 mm thick, 15mm thick plastering in cement mortar (1:4) to all internal and exposed surfaces including excavation of earthwork in any type of soil, MS sheet cover 3.15 mm thick fixed with angel iron frame 50x50x6mm with locking arrangement embedded in PCC and painting of MS cover with two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
Supply, Fixing testing and commissioning of Refrigerator of capacity 400 Litre, Electric driven (single phase) and BEE 5 star rated complete all as specified and directed.
Supply, Fixing testing and commissioning of Desert Cooler (Steel body) having nominal air flow capacity of 4000 CuM per hour (or nearest size), electric driven (single phase) complete all as specified and directed.
Supply and fixing Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVA, confirming to BIS 9815(Parrt-II) and efficiency not less tha 98 % complete all as specified and as directed.
Supply and fixing Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2.0 KVA, confirming to BIS 9815(Parrt-II) and efficiency not less tha 98 % complete all as specified and as directed.
Supply and fixing Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1.0 KVA, confirming to BIS 9815(Parrt-II) and efficiency not less tha 98 % complete all as specified and as directed.
Supply, Fixing and testing of Reverse Osmosis Plant of output capacity 60 Litres per hour. Note: RO rates includes cost of civil work, raw water /clear water storage tank, softener, plumbing and electrical works complete. Feed water characterstics: Turbidity- less than 0.3 ppm, PH range- 6.5-7.2, Total hardness- less than 5000ppm, TDS- less than1500 ppm, Complete all as specified and as directed.
Supply & Fixing MS fabricated brackets /stand for desert cooler of grade Fe-410-W(Grade-E-250) quality-B framed work of angle or other section with gusset plates etc, rails, braces,etc, complete , drillled for fixing of steel sheeting or other covering etc. and hanging also fastering and fixing complete all as specified and as directed.
JASPAL SINGH & CONST (BID ID -3430603)
surendra infrastructure pvt ltd (BID ID -3436649)
M/s godara infratech and power industries (BID ID -3436736)
K R TRADERS (BID ID -3437171)
M/s Matadeen Ramchandra Agarwal (BID ID -3436898)
A.B. Projects Pvt. Ltd. (BID ID -3429397)
AMIT ASSOCIATES (BID ID -3436658)
RAMJI DAS DHAL CONSTRUCTION PVT LTD (BID ID -3436307)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tenderdocument.rar
Tender Documents • 18.27 MB
BOQ.xls
BOQ • 0.52 MB
Tenderdocument.pdf
Tender Documents • 2.60 MB
Tenderdocument_2.rar
Tender Documents • 13.30 MB
Tenderdocument_3.rar
Tender Documents • 18.63 MB
Tenderdocument_4.rar
Tender Documents • 22.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .