Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 CrAccepted-AOC ANANDI NIWAS MAIN ROAD ROURKELA 769001 | ROURKELA | SUNDERGARH | ODISHA | 769001 | ₹4.5 Cr | L1 | Accepted-AOC LOWEST |
| 2 | L2₹4.9 Cr+₹31.4 L (6.92%)Rejected-Finance 32 PANCHWATI NAGAR BATHINDA PUNJAB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | ₹4.9 Cr+₹31.4 L (6.92%) | L2 | Rejected-Finance NOT LOWEST |
| 3 | L3₹5.0 Cr+₹43.4 L (9.56%)Rejected-Finance WZ 143 A 7A S 4 43 GALI NO 2 OLD MAHAVIR NAGAR NEW DELHI 110018 | WEST DELHI | DELHI | 110018 | ₹5.0 Cr+₹43.4 L (9.56%) | L3 | Rejected-Finance NOT LOWEST |
| 4 | L4₹5.1 Cr+₹51.6 L (11.4%)Rejected-Finance | ₹5.1 Cr+₹51.6 L (11.4%) | L4 | Rejected-Finance NOT LOWEST |
| 5 | L5₹5.2 Cr+₹70.0 L (15.4%)Rejected-Finance | ₹5.2 Cr+₹70.0 L (15.4%) | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹4.1 Cr
EMD Value
₹4.9 L
Closing Date
14 Nov 2024, 6:30 pmClosed
HQ CE (AF) WAC PALAM
HQ CE (AF) WAC PALAM, DELHI CANTT-10
COMPLETION OF BALANCE WORK FOR DEMOLITION AND RECONSTRUCTION OF LIVING ACCN FOR AIRMEN AT 8 WING AT AF STN ADAMPUR
2024_MES_671006_1
CEWAC/ADM/T-15/2024-25
Open Tender
Civil Works
Lump-sum
520 days
GE (AF) ADAMPUR
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹2,000
GE (AF) ADAMPUR
₹4.9 L
Yes
28 Jul 2025
27 Sept 2024
18 Nov 2024
27 Sept 2024
14 Nov 2024
8 Nov 2024
Amount
SCHEDULE `A' PART - I (Building Works) is not prepriced by MES and prepriced rates indicates 0.0 under column 6 signified this fact only.
Construction of left over work for SINGLE LIVING ACCN FOR SNCO's (SM BARRACK FOR HAV/SGT -14 PERSONS) complete all as specified and shown on drawings.
Construction of left over work for SINGLE LIVING ACCN FOR OR's (SM BARRACK FOR OR/AIRMEN - 48 PERSONS) complete all as specified and shown on drawings.
Construction of CYCLE CUM SCOOTER SHED FOR OR complete all as specified and shown on drawings.
Construction of PARKING/SCOOTER SHED FOR HAV/SGT complete all as specified and as shown on drawings.
NOTE: Schedule ‘A’ Part II to XII under are Prepriced by MES.
Lump sum price worked out by the Contractor for “SITE CLEARANCE” as listed in Schedule ‘A’ Part II
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part III
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part IV
Lump sum price worked out by the Contractor for "DEMOLITION OF BLDG B/R & E/M ITEMS” as listed in Schedule ‘A’ Part V
Lump sum price worked out by the Contractor for “SOLAR WATER HEATING SYSTEM” as listed in Schedule ‘A’ Part VI
Lump sum price worked out by the Contractor for “ROAD/PATH/CULVERT” as listed in Schedule ‘A’ Part VII
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY ” as listed in Schedule ‘A’ Part VIII
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIFICATION ” as listed in Schedule ‘A’ Part IX
Lump sum price worked out by the Contractor for “WATER COOLER & DESERT COOLER ” as listed in Schedule ‘A’ Part X
Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL ” as listed in Schedule ‘A’ Part XI
Lump sum price worked out by the Contractor for “AREA DRAINAGE” as listed in Schedule ‘A’ Part XII
SCHEDULE `A' PART - XVI MISC B/R & E/M ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 6 signified this fact only.
INTERNAL ELECTRIFICATION
S&F LED light fitting 1 x 10 Watt, 220V, AC, box type with driver, holder incl making connection with three core flexible copper conductor cable 0.5 sqmm from ceiling rose complete all as specified and directed.
S&F LED security light fitting 15 watt, input 110 to 220 volts as per IP 65 luminaries comprising of rectangular shape, high pressure die cast aluminium housing, with weather proof gaskets for lamp and driver compartment with GI pipe 25 mm dia light grade bend to shape including necessary fixing arrangement complete all as specified and directed.
S&F MCB TPN 40 Amps, C curve type 10 KA , 415 Volts complete all as specified and directed.
S&F MCB SPN 32 Amps, C curve type 10 KA, 240 Volts complete all as specified and directed.
S&F MCB SP 6 to 32 Amps, C Curve type 10 KA breaking capacity, 240 Volts complete all as specified and directed.
DEMOLITION OF BLDG B/R & E/M ITEMS
Dismantling of Wash hand basin/urinals including all connections etc complete all as speciified and directed.
Taking down/dismantling of low level flushing cistern with connection etc complete all as specified and directed.
Taking down old bib tap/Stop Cock/Shower any type and size etc complete all as specified and directed.
Demolition of 150 mm thick, average consolidated thickness, mud phuska on flat roofs including mud plaster and leeping plaster etc complete all as specified and as directed .
M&L for taking out old/unserviceable gate/globe valve from existing pipe line complete all as specified and directed.
Dismantling existing old/US main switch, DB SPN/TPN incl MCB's complete all as specified and directed.
Taking down old/US Ceiling/Exhaust Fan incl dismantling blades and depositing the same in MES store yard for reuse/safe custody complete all as specified and directed.
Taking down old/US Light fitting of any description and in any position complete all as specified and directed.
Taking down old/US submain wiring of any type or size and in any position complete all as specified and directed.
Taking down old/US Electric Geyser of 25lit Capacity incl connection pipes etc and depositing the same in MES store yard for reuse/safe custody complete all as specified and directed.
Taking down old/US Suspension type cable 2x10sqmm of any type and in any position complete all as specified and directed.
SOLAR WATER HEATING SYSTEM
Supply, Install, Testing and Commissioning of 'Solar Hot Water System' (Flat Plate Collector) based on indirect transfer of heat of capacity 100 LPD incl backup electric system with heating element of suitable capacity, thermostatic switch, electrical connection etc with and incl complete civil work and MS work for staging for Solar Panel & Hot water tank complete all as specified and directed. Note:- i) Rates incl the cost of backup stainless steel hot water tank (insulated) but does not incl cost of cold water tank & hot/cold water piping. (ii) The solar heating system shall be procured & installed from MNRE approved manufacturer/vendor (iii) Testing shall be done as per MNRE standards.
ROAD/PATH/CULVERT
M&L for providing and marking broken centre/ side lines/zebra Lines, dashes, arrows etc on road pavement and the like of any description and width with termoplastic paint hot applied with machine confirming to BS-3265 and according to the specification laid down by IRC and MOST (Mininstry of Surface Transpost) specification 2001 (4th revision) complete all as specified and directed.
EXTERNAL WATER SUPPLY
M&L for construction of Valve pit chamber 60 cmx60cm (inner dimension) and 60 cm deep , from the top of MS cover fixed on frame of angle, top cover shall be of 3 mm thick MS Sheet with locking arrangement of pad lock of 50mm size including brick work with sub class"B'' bricks in CM 1:4 including 15 mm thick plaster in CM 1:4 (internally and externally) and necessary earth work in any type of soil including returning filling in and disposal of surplus oil to a distance n exc 50 mtrs and 150 mm thick PCC 1:4:8 , type D-2 , using 40mm graded stone aggregates as in floor complete all as specified and directed.
EXTERNAL ELECTRIC SUPPLY
NOTE FOR ITEM NO 8.03 :- The rate quoted by the contractor shall be deemed to include following provision of Platform for the panel with PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate, 15 cm thick in foundation, brick work in CM 1:6 with sub class B old size bricks, rendering sub class B old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100mm thick PCC padding (1:3:6) type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be at a height of 45 cm above the nearest road level. The platform shall be constructed as per manufacturer drawing and design.
WATER COOLER & DESERT COOLER
Supply and install desert cooler with ISI marked fan and made out of PGI sheet of size 18SWG heavy duty with electric driven single phase copper wound fan motor and water pump motor having nominal air flow capacity of 4000 cubic meter per hour or nearest higher side (without any financial effect) in steel body. It includes the provision of connect Gl tubing 15mm size with PVC connection, gland, ball valve and wire for electric connection copper wire 3 core size 1.5 sqmm appx length 3 mtr in desert cooler incl provision of suitable size & length angle iron stand complete all as specified and as directed. Note- Wire for electric connection is deemed to be included in quoted rate but PVC connection, ball valve and Gl tubing are separately measured.
Supply, instalation & testing of Voltage stabilizer of rated capacity 1KVA for automatic operation, single phase wall mounted, air cooled indoor type with digital display & designed for input variation between 170 V to 280 V with: output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1 KVA duly fixed on wall with the help of factory mounting metallic stand and nut, bolt, screw fastener etc incl making connection complete all as specified and directed.
Note :-Schedule of credit will be deducted from total quoted amount while calculating contract sum.
GEMINI PROMOTERS AND BUILDERS PVT. LTD. (BID ID -3165051)
M/S Sunil Steel Works (BID ID -3165400)
Shree Balaji Construction (BID ID -3165635)
Elite Builders (BID ID -3163905)
L G BUILDERS (BID ID -3164532)
Sachdeva Builders (BID ID -3165199)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .