Tender Value
₹3.1 L
EMD Value
₹6,224
Closing Date
6 Jan 2022, 6:00 pmClosed
EE CIVIL
O/o EE CIVIL BSNL CIVIL DIVISION VARANASI
Painting and other miscellaneous civil works in Leased out space to CGST at third floor CTO Tar Ghar Building at BSNL CTO Compound SSA Varanasi
2021_BSNL_99679_1
09/2021-22/EEBSNLCD/VNS
Open Tender
Civil Works
Item Rate
30 days
VARANASI
2 documents required · 2 mandatory
₹590
ACCOUNT OFFICER (CLAIM) O/o GMTD VARANASI
₹6,224
Yes
13 Jan 2022
27 Dec 2021
10 Jan 2022
27 Dec 2021
6 Jan 2022
27 Dec 2021
27 Dec 2021 - 4 Jan 2022
Amount
Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
Welding by gas or electric plant including transportation of plant at site etc. complete.
Distempering with 1st quality acrylic distemper (ready mixed) of approved manufacturer, of required shade and colour complete, as per manufacturer's specification.
a) Two or more coats on new work.
Distempering with 1st quality acrylic distemper (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade :
a) Old work (one or more coats)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
a) One or more coats on old work.
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground , all complete as per directions of Engineer-In-Charge.
With cement mortar 1:4 (1 cement : 4 fine sand).
Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:
a) Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm).
Providing & fixing White vitreous china water closet squatting pan (Indian type) along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge.
Orissa pattern W.C Pan of size 580x440 mm
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required :
W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.
10 litre capacity - White
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively.
Providing and fixing 100 mm sand cast Iron grating for gully trap.
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall
a) 20 mm nominal outer dia. Pipes.
a) 25 mm nominal outer dia. Pipes.
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931:
15 mm nominal bore.
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 :
a) 15mm nominal bore
Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.
a) 15 mm nominal bore with 45 cm length.
Providing unskilled labour for miscellaneous works as required, all complete as per directions of Engineer-in-charge
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
Providing and fixing MTA/FTA in cPVC pipes of
(a) 15 mm nom dia
(b) 20 mm nom dia
Providing manual assistance for plumbing sewer, masonry & carpentry work which are not covered above and are not possible to measure.
Providing and erecting suitable scaffolding/Safety arrangements alonwith safety equipment with necessary anchorge up to required height, for plumbing work all complete as per directions of the E-in-C
Providing and laying water proofing treatment over Roof Terrace or at place where leakage occured etc after cleaning of joints and terrace surface with wire brush and removing all dusts ,debris etc ., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry, all complete as per direcion of E-in-C
Labour charges for Mopping/ Cleaning of all floors in all the rooms i/c wall tiles in bathrooms with detergents/surf etc complete as per direction of Engineer-in-charge
Replacing damaged G.I. Jali in Jali doors/windows i/c cost of material & labour all complete as per direction of Engineer-in-charge.
Transportation of Unusable items like Iron sections, furniture, Almirahs, Aluminium Section,partition and all other miscellaneous items etc lying at 3rd Floor,Tar Ghar, CTO Compound, Cantt to BSNL Store at Lalpur per trip all complete as per direction of E-in-C
Credit of unserviceable/rusted material
a) GI pipes 15mm
b) GI pipes 15mm
c) Cistern
M/S S K CONTRACTOR
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .