Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 2ND FLOOR SHOP NO 303 MARUTI PLAZA RONCHI BANGAR TOWNSHIP MATHURA | MATHURA | UTTAR PRADESH | 281001 | Admitted-Finance |
| 4 | Admitted-Finance 19 A DURGA BARI SADAR BAZAR MEERUT MEERUT MEERUT UTTAR PRADESH 250001 | MEERUT | UTTAR PRADESH | 250001 | Admitted-Finance |
| 5 | Admitted-Finance BH 16 MANSAROVER COLONY LINE PAR MORADABAD UTTAR PRADESH 244001 | MORADABAD | UTTAR PRADESH | 244001 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
31 Mar 2021, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER
132 KV S/S Lalkuan, Ghaziabad
works
2021_UPTCL_573886_1
T-30/ETD-II/GZB/2020-21
Open Tender
Electrical Works
Fixed-rate
60 days
132 KV S/S Lalkuan, Ghaziabad under ETD-II, GZB
as per documents
2 documents required · 2 mandatory
₹1,180
As per NIT
₹10,000
5 Apr 2021
20 Mar 2021
31 Mar 2021
20 Mar 2021
31 Mar 2021
20 Mar 2021
120 days
Amount
Erection of structures
Sorting and stacking of structures
Erection of Auxiliary structure lactic type ALP,BBL,ABL,BCT,CCM,CPM etc. consisting of column, beam, peak, mast etc. and auxiliary structure for installation of LA, etc. The job consist of shifting of all material from store to site of erection . Erection of structure as per drawing with the help of GI nut & bolt, flat & spring washer, matching the hole , cutting & matching of member if required including cost of all men and T&P excluding GL structure Nut & bolt to complete the work. Erection of main & Auxiliary structure lattice type ALP etc. upon foundation and its proper tightening.
Making the hole in part of GI main/auxillary structure/cutting of GI angle drilling of hole existing/defective structure/plate/angle and grinding machine with all cost of men,T & P etc
Erection of following equipments/panels as per the technical specification , manual ad instruction as per supervising engineer.
145 KV SF6 circuit breaker
145 KV Current transformer
145 KV Bus isolator
145 KV Post insulator for support
120 KV Lightening arrestor
145 KV Potentional Transformer
Erection and mounting of 132KV CT/PT Junction box
33 KV Vaccum Circuit breaker
33 KV Bus Isolator
30 KV Lightening isolator
33 KV Bus Post Insulator
Erection and mounting of 36 CT/PT Junction box
132/33 KV 63 MVA T/F Control and relay panel
Earthing work
Laying of 400 mm dia MS round bar 700 mm below the ground level by the cutting straihtening welding painting excavation of trench back filling of trench after laying of earth mat including shifting of MS round bar from store place at the sub station to switchyard.
Fabrication of 3 meter long electrodes with 40 mm dia MS round bar having 150 mm long conical shape by digging cutting, straightening etc. and then placing it vertical inside the ground with Top 700 mm below the ground level including shifting of MS round bar from storage place at the sub station to switchyard.
Delta earthling of 120/30 KV LA and its neutral of 63 MVA Transformer neutral by 40 mm dia 150 mm long conical shape its placing inside the ground in rectangular shape and connecting all 3/6 Nos electrodes with MS ROD/M S Flat laid on its edge and then this rectangles/tringle shape be connected to main earth mat at two place in opposite direction strictly as drawing.
120 KV LA (Rectangular/Triangular shape by 04/03 electrodes) with 40 mm dia round bar
33 KV LA (Rectangular/Triangular shape by 04/03 electrodes) with 40 mm dia round bar
63 MVA T/F (Triangular shape by 03 electrodes) with 40 mm dia round bar
Earthing of equipment’s by cutting straightening, bending, laying 700 mm below ground and above ground of following size of MS flat for ear thing of main and auxiliary structure, equipment structure. Transformer body and its neutral point including welding with main earth mat and with main earth mat and with object to be earthed. Excavation of trenches, its. Back filling. Painting and all other associated work as required to complete the work.
Laying of MS Flat of size 75 x10 mm
Laying of MS Flat of size 50 x6 mm
Laying of MS Flat of size 25 x6 mm
Panting of MS flat of different size welding with Equipment/structure I coat of red oxide and 2nd coat of bus green paint as per side requirement.
Cable laying and terminattion work
Laying & Termination of following size control cable in trench/cable trays from different control room equipment to Transformer marshaling box and other outdoor equipment installed in 220/132 KV switch yard as per cable schedule including cartridge of cable drum from store and all other associated work.
2 core x 2.5 mm
4 core x2.5 mm
6 core x 2.5 mm
10 core x 2.5 mm
Termination of control cable
Jumpering, interconnection of equipment with specified conductor of various 132/33 KV equipments with Main/Transfer/Tack Bus Bar of ACC Tarantulla/ACSR Moose/Zebra/Panther conductor. The work includes cutting of conductor, bending in proper shape3, clamping with the helf of clamps and all other associated work to complete the work.
132 KV 63 MVA Transformer Bay with ACSR single Zebra
33 KV Site 63 Mva Transformer LV side fo Twin Moose condcutor.
Supply Portion
4 Bolted type PG clamp suitable for Zebra to Zebra conductor complete with HDG nut bolt & washer as per technical specification
4 Bolted type PG clamp suitable for Zebra to Panther conductor complete with HDG nut bolt & washer as per technical specification
4 Bolted type PG clamp suitable for Moose to Moose conductor complete with HDG nut bolt & washer as per technical specification
4 Bolted type PG clamp suitable for Moose to Moose conductor complete with HDG nut bolt & washer as per technical specification
Bimetallic terminal connector for 63 MVA T/F HV side bushing rod 30 mm dia made of aluminium alloy LM-6 suitable for single ACSR Zebra conductor matching with bushing rod complete with hot dip galvanized nut & bolts as per technical specification
Bimetallic terminal connector for 63 MVA T/F LV side bushing rod 30 mm dia made of aluminium alloy LM-6 suitable for ACSR twin moose conductor matching with bushing rod complete with hot dip galvanized nut & bolts as per technical specification
Bimetallic 132 KV CT clamp made of aluminium alloy LM-6 for Zebra conductor with HDG nut & bolts and washer as per technical specification
Bimetallic 132 KV Isolator clamp made of aluminium alloy LM-6 for Zebra conductor with HDG nut & bolts and washer as per technical specification
Bimetallic 132 KV Circuit Breaker clamp made of aluminium alloy LM-6 for Zebra conductor with HDG nut & bolts and washer as per technical specification
Bimetallic 132 KV LA clamp made of aluminium alloy LM-6 for Zebra conductor with HDG nut & bolts and washer as per technical specification
Bimetallic 132 KV Post Insulator clamp made of aluminium alloy LM-6 for Zebra conductor with HDG nut & bolts and washer as per technical specification
Bimetallic 132 KV PT clamp made of aluminium alloy LM-6 for Zebra conductor with HDG nut & bolts and washer as per technical specification
Bimetallic 33 KV Isolator clamp for ACSR twin moose conductor complete with hot dip galvanized nuts,bolts and wsaher as per technical specification
33 KV Circuit Breaker clamp for ACSR twin moose conductor complete with hot dip galvanized nuts,bolts and wsaher as per technical specification
33 KV CT clamp for ACSR twin moose conductor complete with hot dip galvanized nuts,bolts and wsaher as per technical specification
33 KV LA clamp for ACSR twin moose conductor complete with hot dip galvanized nuts,bolts and wsaher as per technical specification
33 KV PT clamp for ACSR twin moose conductor complete with hot dip galvanized nuts,bolts and wsaher as per technical specification
33 KV Bus Post clamp for ACSR twin moose conductor complete with hot dip galvanized nuts,bolts and wsaher as per technical specification
Technocrat Electrical
ishu brothers
P&H Engineering
TIRUPATI ELECTRICALS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .