Chief Engineer Chennai Zone
HQ CECZ Island Grounds Chennai - 09
PROVN OF EFFLUENT TREATMENT PLANT ETP WITH COMPLETE BR EM FITTINGS AT MH CHENNAI UNDER GE STM
2021_MES_470144_3
82931/E8
Open Tender
Civil Works
Lump-sum
365 days
GE STM
As per tender documents
8 documents required · 8 mandatory
₹2,000
GE STM
₹3.8 L
Yes
25 Apr 2022
8 Nov 2021
8 Dec 2021
8 Nov 2021
6 Dec 2021
24 Nov 2021
8 Nov 2021 - 17 Nov 2021
Amount
GENERAL SUMMARY NOTE: Schedule ‘A’ Part I to XI are under Ser No. 2.00 to 12.00 are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lumpsum price worked out by the tenderer for BUILDINGS / STRUCTURES as listed in Schedule ‘A’ Part-I
Lumpsum price worked out by the tenderer for SITE CLEARANCE as listed in Schedule ‘A’ Part-II
Lumpsum price worked out by the tenderer for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-III
Lumpsum price worked out by the tenderer for INTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-IV
Lumpsum price worked out by the tenderer for ROADS / FOOT PATH / CULVERTS as listed in Schedule ‘A’ Part- V
Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-VI
Lumpsum price worked out by the tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-VII
Lumpsum price worked out by the tenderer for STANDBY GENERATOR SET as listed in Schedule ‘A’ Part-VIII
Lumpsum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part- IX
Lumpsum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part- X
Lumpsum price worked out by the tenderer for COMPOUND WALL / FENCING as listed in Schedule ‘A’ Part- XI
SCHEDULE `A' PART - XII TO XVI are not prepriced by MES and prepriced rates indicating 0.0 under column 5 signifies this fact only. Bidders shall insert their rates in Green field under Col-6.
SCHEDULE 'A' PART XII -SEWAGE TREATMENT PLANT :
Construction of Sewage Treatment Plant (STP) 200 KLD capacity with permanent specification with RCC M-30 Grade, Design mix concrete, for tertiary treatment consisting bar screen chamber, oil and grease remover, equalization tank, Anoxic tank, Moving Bed Bio Reactor(s) (MBBR tank-1, MBBR TANK-2, MBBR TANK- 3), tube settler tank ,clear water tank, chlorine dozer tank, Treated water tank, Sewage sludge collection tank , sludge drying bed, Foundation for all E/M equipments etc., all as specified and as shown on drawings Note : STP E/M items as listed in Sl No 14.02 to 14.38 should be measured and paid seperately.
Supply and fixing stainless steel grade(SS-304) pipe varying from 20mm to 80mm dia heavy grade with all fittings and fixtures for provision of air grid laid in floors or fixed to wall, etc including necessary welding joints and coarse bubble v notch holes, etc complete all as specified
Supply and fixing of mid steel Pipe 32mm bore,ISI marked(IS-1239) heavy grade with all fittings and fixtures for fixed to wall, ceiling etc including necessary welding joints works complete all as specified
Supply and fixing of mid steel pipes 50 mm bore,ISI marked(IS-1239) heavy grade with all fittings and fixtures with flanged ends laid in trenches/wall/floors etc complete all as specified
Supply and fixing of mid steel pipes 65 mm bore,ISI marked(IS-1239) heavy grade with all fittings and fixtures with flanged ends laid in trenches/wall/floors etc complete all as specified
Supply and fixing of mid steel pipes 80 mm bore,ISI marked(IS-1239) heavy grade with all fittings and fixtures with flanged ends laid in trenches/wall/floors etc complete all as specified
Supply and fixing of mid steel pipes 100 mm bore,ISI marked(IS-1239) heavy grade with all fittings and fixtures with flanged ends laid in trenches/wall/floors etc complete all as specified
Supply and fixing of mid steel pipes 150 mm bore,ISI marked(IS-1239) heavy grade with all fittings and fixtures for fixed to wall, ceiling etc including necessary welding joints works complete all as specified
Mild steel flanges welded to MS pipe of any description including necessary nuts,Bolts & washers, tees, bends, dead plates, MS clamps etc completeall as specified
Supply and fixing CI butterfly valve,flanged type, confirming to IS 13095 suitable for 50 mm bore pipe complete all as specified
Supply and fixing CI butterfly valve,flanged type, confirming to IS 13095 suitable for 65 mm bore pipe complete all as specified
Supply and fixing CI butterfly valve,flanged type, confirming to IS 13095 suitable for 80 mm bore pipe complete all as specified
Supply and fixing CI butterfly valve,flanged type, confirming to IS 13095 suitable for 100 mm bore pipe complete all as specified
Supply and fixing CI butterfly valve,flanged type, confirming to IS 13095 suitable for 150 mm bore pipe complete all as specified
Supply and fixing/laying MBBR media made of poly proplyene with virgin plastic UV stabilised specific gravity 0.95 to 0.98 complete all as specified to provide the Microbial biofilms to the sewage..
Supply and fixing cast iron double end flanged and drilled non return valve confirming to IS -5312 suitable for 80 mm bore pipe complete all as specified
Supply and fixing cast iron double end flanged and drilled non return valve confirming to IS -5312 suitable for 65 mm bore pipe complete all as specified
Supply and fixing cast iron double end flanged and drilled non return valve confirming to IS -5312 suitable for 150 mm bore pipe complete all as specified
Supply and fixing/laying Tube settler modules made of PVC complete all as specified to enhance the rate of settling sludge in tube settler tank
Supply , installation, commissioning and testing of non clog submersible sewage pump set for type of installation stationary suitable to handle domestic sewage water having Discharge 300LPM at a head of 10 metre, 415 V (+/- 10%)& frequency 50HZ +/-3%), as per manufacturer specifications (For 02 Nos COLLECTION CHAMBER BEFORE STP-02 Nos pumps for each sump ).Pump includes Submersible cable of required size and length from non clog submersible pump set to starter. Material of constructions: Pump casing (pump+motor) CI (FG 260),Impeller: CI (FG 260),Shaft :SS-410,.
Supply , installation, commissioning and testing of non clog submersible sewage pump set for type of installation stationary suitable to handle domestic sewage water having Discharge 140 LPM at a head of 10 metre, 415 V (+/- 10%)& frequency 50HZ +/-3%), as per manufacturer specifications (For Equalisation tank ). Pump includes Submersible cable of required size and length from non clog submersible pump set to starter. Material of constructions: Pump casing (pump+motor) CI (FG 260),Impeller: CI (FG 260),Shaft :SS-410.
Supply, installing, testing and commissioning of centrifugal pumping set mounted on common base plate fountation with discharge of pumping set 152 LPM at 25 mtr head directly coupled with electric motor of suitable capacity for above pumping set complete with all acessories. (For clear Water Tank to filters) :- (i) PCC platform in cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate 30cm above ground level including necessary eye bolts etc as per manufacturer recommendation. (ii) Necessary cable connection of suitable size copper conductor laid from starter to motor terminals.
Supply, installing, testing and commissioning non-clog centrifugal pumping set mounted on common base plate fountation with discharge of pumping set 50 LPM at 5mtr head directly coupled with electric motor of suitable capacity for above pumping set complete with all accessories (For sludge transfer Tube settler to sludge drying beds) :- (i) PCC platform in cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate 30cm above ground level including necessary eye bolts etc as per manufacturer recommendation. (ii) Necessary cable connection of suitable size copper conductor laid from starter to motor terminals.
Supply & fixing electronic metering type dosing pump of 6 LPH with all acessories such as lead tubing, connecting nuts, injection check valve with including PVC tank of 200 ltrs.
Supply, fixing Air compressor assembly complete of capacity 150 Cum/hour @ 3 m head, 415 V, 3 Phase 50 Hz complete with valves, NRV, rubber flexible connections where required & connected to air distribution grid complete as required and 2mm thick Gl hood cover for protection from rain having proper ventilation arrangements, all connecting copper conductor cables, contrll cables, etc complete all as specified and shown on drawings. Note: (a)Type of blower: Twin lobe root blower
Supply and fixing of bar screen made of 3 x 20 x 650 mm strips spaced at a distance of 10 mm and fixed at an angle of 60 degrees to horizontal, all bar strips firmly welded to single frame of 30 x 3 mm, entire bar screen unit is made in stainless steel 304 grade material complete all as specified and directed.
Supply and fixing of lint catcher screen box of size 200 mm Dia x 600 mm Length, in SS 304 material, in bottom position in the MBBR tanks with SS riser pipe complete all as specified and directed.
Supply and fabrication framed brackets of angles or tees with web and flanges cut to shape, drilled and counter sunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel') Stuctural steel for support as required size and shape on ground or asper OEM DESIGNED ( with proper I.S) complete all as specified and directed.
Supply and fixing of Anoxic mixture of capacity 0.5 HP for Anoxic tank turbine type as per OEM recomandation complete all as specified and directed.
Supply and fixing of FLOW METER/TOTALIZER of following specifications. Online Electromagnetic water flow meter with totalizer meter in treated water line with all accessories.Full Bore Electromagnetic Flow meter cum Totalizer Sensor specifications are as under. (i) Meter size:50mm (ii) Sensor Housing :Cast Aluminium Alloy Linear Material:Elastomer End connection :Electrode Material :316 SS (iii) Metering Tube material:Stainless Steel (iv) Environmental protection:IP 68/NEMA 6 Transmitter Specifications are as under:- Power supply :85-256 V AC up to 400HZ at 20Va max . Outputs:Analog(4-20 mA) , Fully isolated Enclosure:Glass Loaded Polyproplene, polycarbonate window Electrical connections:1/2"NPT Display:2-line LCD Display Mounting :Integral Temperature: Operating-10 to 60C Environmental protection:IP 65/NEMA 4 Service :Water Flow (min/max) 0-60m3/hrs
Supply and fixing of LEVEL SENSOR, Magnetic type float switch to protect High Level/ overflow , dry run protection as required to on/off the connected pums/motors according to level of sewage/water,all as specified and directed
Supply and fix Hand operated Chain pulley Block of capacity 1 ton having load chain 6 mm dia and standard lift height 3 meters, automatic double pawl breaking system , alloy steel load wheel mounted on 4 ball bearing , double cover protection, fully forged hooks are fitted with safety latches, zinc plated hand chain etc complete all as specified .
Supply, fixing and commissioning factory fabricated multi media filter (MMF), cylinderical shape mild steel construction , epoxy coated of 1000 mm Dia and 1800 mm HOS with supporting layers of pebbles and graded quartz gravels as filter media with & including suitable staging as per manufactures/OEM instructions complete all as specified .
Supply, fixing and commisioning factory fabricated activated carbon filter (ACF), cylinderical shape mild steel construction , epoxy coated of of 1000 mm Dia and 1800 mm HOS with active carbon Layers as filter media with & including suitable staging as per manufactures/OEM instructions complete all as specified .
Supply and fixing new LT panel cubical type of suitable size, 3 phase 415 volt, factory made dust proof vermin proof (Kiosik type) for Indoor use made out of CRCA sheet 3.15mm thick except inner sheath OG 2mm powder coated, machinepressed, both side opening in two halves with provision of rubber beading and locking system , including aluminium busbar of 200 Amp capacity , 4 strip mounted on procelian insulator, bus bar chamber shall be provided with inspection covers each MCCB shall be have be independant opening, panel should be monthed on angle frame and legs ( vertical height on legs not less than 30cm except in PCC) made from angle of size 50X50X5 mm , frame and legs duly spray painted internally and externally with two coats of synthectic enamel paint over a coat of red oxide primer legs grounted in PCC(1:3:6) type B-2 (using 40mm graded stone aggregate) complete including all connection/ control wiring with suitable size of copper conductor cable, including danger notice sticker, comprising the followijng accessory including testing complete all as specified ( For main STP)
(a) MCCB 200 Amps 25 KA , 4 pole , Icu=100% Ics -01 No(Incomer) (b) MCCB 32 Amps 16 KA , 4 pole , Icu=100% Ics -08 Nos(Outgoing)(for equilization tank, filters, treated water pump,air compressor) (c) MCB TPN 10 Amps 10 KA , Icu=100% Ics -04 Nos(Outgoing)(sludge , chlorization) (d) Suitable Star delta / DOL Starter suitable for each 3 phase motor. (e) Suitable MCD for each single phase motor / dosing pump. (f) R,Y,B Indicators-01 set (g) digital Amp meter (0-200)Amp incl necessary CTs (set of three)-12 sets (h) Digital volt meter (0-500)- 01 No (j) ON Load Change over switch 160Amps 4 pole -01 No (k) Single phase preventer (l) Energy meter of suitable capacity 3 phase digital display alongwith 3 CT'sat main incoming-01 No (m) Rubber mating 12 mm thick for full length of main electric control panel -01 no (n) Out Going : MCCB 63 Amps , 3 Pole 16 KA , ICU =100 % , thermal Magnetic release , fixed Type -.03 Nos (o) One lot of power & control LT Cable XLPE insulated Screened PPVC Bedded , Galvanised steel strip or wire armoured , electric power cables (Heavy Duty) 1100 volts grade with Aluminium Conductor for interconnection between LT Panel / Starter to pump Motors. NOTE : The rates shall be included in the quoted rate.
Supply and fixing Aluminium Dosing pump high presure single head geared motor adjustable dosing pump with accessories such as Lead tubing , connecting nuts , injection check valve , clay weight and ferrules with following specifications including PVC tank of 200 ltrs. (i) Adjustable High Pressure 0-100 PSI (ii) Power -230 Volts , 50 Hz (iii) RPM -44 (iv) HP -1/30 fractional (v) Out put -2 US GPD to 40 US GPD
SCHEDULE 'A' PART XIII - EFFLUENT TREATMENT PLANT
Design, Supply, Installation,erection,testing and commissioning of Compact Efflument treatment plant (ETP) of capacity 50 KLD for treating of Hospital generated effluent and biological waste espisialy from blood bank / laboretory and other various locations from Military Hospital Chennai as a raw effluent/ sewage,designed on input average parameters and desired output parameters as given below to include civil works and all foundation, complete as specified in the specifications and work includes civil structural drawings for the RCC tanks vetted from NIT/Govt Engg College to be submitted by the bidder before execution of the work. as specified and OEM drawing and as mentioned below. (i) Daily Avg. Efflument/Sewage : 50m3/days ie 50 LD (ii) Avg flow of Efflument/Sewage : 2.5m3/hour (iii) PH : 6.0-8.0 (iv) Peak flow of Efflument/Sewage : 5m3/hour (v) TSS : 200-300 ppm (vi) BOD : <300 ppm (vii) COD (Bio degradable) :up to 1000 ppm (viii) Oil and grease :<50 ppm Treated water standards for reuse PH :6.0 to 8.5 TSS :<100 ppm BOD 5 :<30 ppm COD :<300 ppm Oil and grease :<10 ppm
All equipments and components pertaining to primary, Secondardy /biological treatment, tertiary treatment and sludge treatment to be provided with all acceddories complete comprising of the following components One no. Fine bar screen chamber fitted with screen of MSEP construction as per given specifications . (i) Size of chamber 1.0 x 0.3 x 0.5 m MOC of chamber RCC M 30 Design Mix MOC of Screen 15 x 5 mm thick SS flat, with frame Clear Spacing (mm) 6 mm Dimensions of Screen 0.3 x 0.5 m (ii) One no. Equalisation tank in RCC M30 Design Mix construction fitted with air grid of uPVC construction for providing aeration in the tank suitable to provide the 25 m³/hr air to the tank, covering complete bottom surface, the sizes of tank is 3.7 x 3.7 x 2.5 m SWD with 0.3 m Free board, (iii) Two nos. (1 working & 1 standby) raw effluent centrifugal monobloc self-priming pump each of 2.1 m3/hr @ 10 m head capacity with motor and all necessary accessories and fittings, to be installed for transferring sewage from equalization tank to process. Level sensor should be provided in the tank and interlinked with pumps for ON-OFF operation as per water level in the tank. One pressure gauge for each pump has to be provided to measure pressure at the outlet.
(iv) Two nos. (1 working & 1 standby) Twin lobe Air blower of 25 m3/hr @ 3.0 m head capacity with Direct drive 0.55 kW motor and all necessary accessories & fittings, for providing air in equalization tank. (v) One no. Flash Mixing tank in MSFRP construction fitted with agitator as per the given specifications and drawings Agitator 0.18 kW Mixer MOC Cast Iron Capacity of tank 300 lt. (vi) One set of Coagulant dosing system comprising of solution tank in HDPE of 500 ltr. Capacity fitted with agitator of 0.18 kw and 2 nos. (1 working and 1 standby) electronic metering type dosing pump of 20 lph each (single phase 100 Watt), as specified, with necessary connection. (vii) One set of Flocculant dosing system comprising of solution tank in HDPE of 100 ltr. Capacity fitted with agitator of 0.12 kw and 2 nos. (1 working and 1 standby) electronic metering type dosing pump of 6 lph each (single phase 40 Watt), as specified in PS, with necessary connection. (viii) One No. Ozonator having capacity of 10 gm/hr, Stainless steel water cooled ceramic dielectric type, Single Phase 230 V, 50 Hz 600 Watt. (ix) One no. Flocculation tank tank in MSFRP construction fitted with agitator as per the given specifications and drawings Agitator 0.18 kW Mixer MOC Cast Iron Capacity of tank 1000 lt.
(x) One Set of Tube settler tank in MS FRP construction with all internals comprising of media, supporting structure & collection trough as per specifications and drawings. Type Square tube type Media height at 60 degrees 600 mm MOC of Media UV Stabilized Virgin PVC Base Shape of Media Hexagonal (Chevron) Shape Cross Section Area Horizontal-120mm, Vertical-48mm Tube Fitting Tongue and Groove Thickness 1.0mm (+ 0.1mm) Plan settling area 12-14 m2/m3 Weight 64 kg/m3 Color Black Tank Dimension-1.5 x 1.5 x 2.5 m SWD + 1.0 m Hopper + 0.3 m FB (xi) Two nos. (1 working & 1 standby) sewage centrifugal monobloc self-priming sludge transfer pumps each of 2.0 m3/hr capacity @ 6 m head of 0.37 kW motor and timer based operation for set time after every set interval of time, with all necessary accessories and fittings for transferring sludge from bottom of the Tube settler to the sludge holding tank. One pressure gauge for each pump has to be provided to measure pressure at the outlet (xii) One no. Sludge Bag Unit in SS construction, fitted with one no. non-woven geotextile fabric bag as per given specifications, to receive sludge from tube settler tank, complete with DWPE dosing tank, static mixer and dosing pump.
SCHEDULE `A' PART - XIV- FITTINGS & FIXTURES AND MISCELLANEOUS ITEMS is not prepriced by MES and prepriced rates indicating 0.0 under column 5 signifies this fact only. Bidders shall insert their rates in Green field under Col-6.
M&L for earthing complete with Galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filled in alternate layers and electrode connections by using Galvanised earth strip 32x6mm connected by means of bolts, nuts, check nuts and washer of galvanised iron or steel, provision of 40 mm dia GI pipe light grade for protection of GI earth strip and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) type C1 chamber of size 45cm X 45cm X 45cm including, MS funnel, wire mesh, 50 mm thick RCC 1:2:4 type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to a distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of SSR Part-I
Supply, installing, testing commissioning of centrifugal pumping set mounted on common base plate foundation with discharge of pumping set 250 LPM at 15 mtr head directly coupled with electric motor of suitable capacity for above pumping set with all accessories :-(For treated water transfer for arboriculture):- complete all as specified and as directed. (i) Delivery pipe 80mm dia MS pipe medium grade from pump set to existing delivery pipe flanged type complete with all fitting suitable for flanged pipe and necesssary nut, bolts, washers and rubber gasket etc including fixing of sluice valves and non return valve all as required. (ii) PCC platform in cement concrete 1:2:4 type B- 1using 20mm graded stone aggregate 30cm above ground level including necessary eye bolts etc as per manufacturer recommendation. (iii) Necessary cable connection of suitable size copper conductor laid from starter to motor terminals.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure.
Construction of valve chamber of internal size 900X900X900mm suitable for 80 mm dia sluice valve including necessary earth work excavation PCC 1:4:8 in foundation type D2 using 40mm graded stone aggregate , brick wall in CM 1:4, PCC 1:2:4 type B1 for coping, 15mm thick rendering in CM 1:4 includin provision of MS Sheet cover 3.0 mm thick with MS angle frame 25X25X3mm all round and at diagonals of size 40X40X6mm and also MS plate welded to MS angle as shown in drawing, embedded in concrete with suitable hinges and locking arrangements, including two coats of synthectic enamel paint over a coat of rd oxide primer necessary excavation earth work etc ,all as specified and as directed
Construction of valve chamber of internal size 750X750X750mm suitable for 50 mm dia gate valve including necessary earth work excavation PCC 1:4:8 in foundation type D2 using 40mm graded stone aggregate , brick wall in CM 1:4, PCC 1:2:4 type B1 for coping, 15mm thick rendering in CM 1:4 includin provision of MS Sheet cover 3.0 mm thick with MS angle frame 25X25X3mm all round and at diagonals of size 40X40X6mm and also MS plate welded to MS angle as shown in drawing, embedded in concrete with suitable hinges and locking arrangements, including two coats of synthectic enamel paint over a coat of red oxide primer necessary excavation earth work etc ,all as specified and as directed
Suply, installation, Testing and commisioning of Laboratory components to do all basic testing likeBOD,COD,TSS,TDS,PH etc the following must be provided and additional if any required other than the ones provided in the list below to make testing complete all as specified and as directed. (i) BOD Incubator, (ii) COD Digestion Hood(Open Reflux Method), (iii) BOD Bottles, (iv) Hot air oven, (v) Filter Papers , (vi) Glass wares and chemicals (vii) PH and Conductivity meters (viii) Chemicals for BOD and COD Estimation
Supply and Fix LED street light fittings 80 watts 6000K new generation energy saving & environment friendly long life versatile pressure die cast aluminium IP 66 roadway luminaire with high power LED as light source and electronic driver electric operated AC single phase 240 volts with all accessories and pre-wired complete including PVC three core flexible copper conductor cable 2.5 Sqmm through PVC conduit pipe 20mm dia with clamps complete all as specified and as directed.Make:- Havells, CAT NO -ENDURAPEARLPLUSS L80W LED 757 PASYTOPC or its Equivalent make as specified.
Supply and installation of Gate light 25 W LED 5700K New generation Post top energy saving & environmental friendly long life versatile spun aluminium IP66 roadway luminaries with high power LED as light source and electronic driver electric operated AC single phase 240 volts with all accessories and pre-wired complete including PVC three core flexible copper conductor cable 2.5 Sqmm through PVC conduit pipe 20mm dia with clamps complete all as specified and as directed. Make:- Havells Cat part CORALPT25WLED757PSYMTOPC or equivalent in Philips/Wipro
Addn/ Altn to existingPanel Board including provision of MCCB 4 Pole125 Amps 25 KA -01 No with Steel Sheet enclosuresfor proposed tapping pointfrom existing power house
STANDBY GENERATOR SET Supply, install, test and commissioning diesel engine driven silent generating set with Microprocessor/ relay based AMF built in control panel, 415 volts, 62.5 KVA 3 phase, 0.8 power factor, 50 Hz, brushless, 1500 rpm, self excited, self regulated, AC, and conforming to conditions under IS 4722,1460 BS-5514,5000 and ISO 8528,3046 complete all as specified and as directed with and including following:- Make Kirloskar Green or Cummins.
(A) ALTERNATOR: Standard design alternator rated at 62.5 KVA at NTP and at power factor 0.8, AC 3 phase, 4 wire 415 volts, 50 cycles, 1500 rpm, self excited, self regulated, screen protected , brushless design, revolving field, self regulated through an AVR ,IP 23 protection with insulation class 'H'. (B) DIESEL ENGINE: Adequate capacity diesel engine suitable to above alternator, Liquid cooled, to drive independently above alternator directly coupled to alternator through flexible coupling or multicylinder, multistroke, direct injection, cold starting, 1500 rpm, as per relevant ISI/BS-5514 complete with standard accessories all as specified and required for safe running and operation. salient features of accessories shall be as under:- (i) Flywheel housing (ii) Air cleaner wet/dry type (iii) Fuel Filter (iv) Fuel Injection system incl. Injection pump, solenoid switch, nozzle as per manufacturer's specifications (v) Lubricating oil filter, bypass filter, oil cooler (vi) Lubricating oil pump (vii) Turbocharger (viii) Radiator for liquid cooling (ix) 12 volts starting system consisting of batteries of capacity as recommended by manufacturer, battery connections with copper leads and with lugs of adequate size, initial charging of batteries, battery charger/ generator with regulator, starter motor, starter gear, start and stop push buttons, ignition key and switch.
(x) Residential type exhaust silencer complete with exhaust pipe of suitable size dia upto outside the acoustic enclosure, all covered with glass wool wrapped with aluminium foil of suitable swg adequate to create draft for safe exhaust without transferring vibrations to buildings/walls, flexible exhaust pipe complete. (xi) Microprocessor control electronic metering and module (ECPG) for indication of battery voltage, oil pressure, water pump, engine rpm, hour meter and protection against low oil pressure, high water temperature and over speed of engine incl. electronic governing. (xii) Battery charging indicator (xiii) Radiator cooling system comprising of radiator, radiator fan belt, water pump with belts, thermostat. (xiv) Fuel hoses. (xv) Separate fuel tank of suitable capacity Type Drag type in base frame all fuel supply lines as required at site and as per manufacturers instructions including return and overflow as well as fuel filling arrangements. (xvi) Air intake system . (xvii) Common base frame of sturdy design suitable for antivibration mounting and permanent concrete foundation for mounting engine and alternator as per manufacturers instructions.
(C) AMF CONTROL PANEL: AMF Control panel shall be Microprocessor Relay based built in panel made out of suitable thick CRCA sheet of 14/16 gauge complete factory made dust and vermin proof, totally enclosed with front opening of 415V 3 phase, 4 wire system AC 50 Hz, having Aluminium busbar of capacity suitable capacity with incoming and outgoing termination with having facilities:-. (i) Key switch / Auto start generator set controller (ii) Multi digital function meters displaying the following parameters:- (iii) voltage, current, KVA, KW, Frequency (iv) oil pressure, water temperature (v) MCCB of suitable rating with overload and short circuit protection. (vi) current transformers. (vii) Indicating lamps for "load ON" and set running". (viii) Instrument fuses duly wired and ferruled . (D) Gen set controller: It should be a micro processor based generator set monitoring and control system mounted in the Gen set control panel .It should provide a simple operator interface to the generator set, manual and remote start/stop control, shutdown fault indication, and a LCD hour counter. (E) Control system : It should have all the functions necessary to locally or remotely start and stop and protect the generator set. (F) Key switch:- OFF and MANUAL/AUTO- in the off mode, the generator will immediately shut down (if running) and cannot be started. It also resets any fault.
(G) Manual start button -It should initiate a gen set in start sequence when the control is in MANUAL/AUTO mode. (H) LED indicating lamps- It should includes LED lamp indication for the following functions :- (i) Fail to start (ii) Over speed/ under speed (iii) Low oil pressure (iv) High engine temperature (v) Battery charging alternator fail. (J) Acoustic insulated enclosure/canopy for Generating set:- Acoustic enclosure shall be factory made up of 1.6/2 mm thick CRCA sheets built and walls of the enclosure are insulated with fire retardant foam so as cmply with the 75 dBA at a mtr sound level conforming to the provisions of environment (protection) second amendment rules 2002 issued vide notification no. GSR371(E) dated 17 May 2002 at Sl No 94 (Para 1&3) and tested complete . The enclosure has the following features: (i) Specially designed to meet stringent MOEF/ CPCB norms of 75 DBA at a mtr 75% load under free field conditions. (ii) Single point lifting for easy handling at site. (iii) Air inlet louvers specially designed to operate at rated load. (iv) Insulation materials should meet exacting IS 8183 specifications for better sound attenuation. (v) Fuel drains for lube oil and fuel. (vi) Fuel filling point
(K) Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads including PCC Foundation as per OEM design. NOTE: The capacity of generator set shall be net after all derating factors as per relevant design.
Supply and fix Steel gate 5.50m wide including 1.50M wicket gate construction of RCC pillars as per drawing incl plastering , granite wall cladding in pillar, excavation in hard dense soil complete all as specified and as directed.
Material and Labour for DWCPE 150mm pipe class SN8 double corrugated , laid and jointed complete all as specified and as directed.
Material and Labour for DWCPE 200mm pipe class SN8 double corrugated , laid and jointed complete all as specified and as directed.
SCHEDULE 'A' PART XV (MANNING AND OPERATION OF STP & ETP DURING DEFECTS LIABILITY PERIOD)
NOTE FOR ITEM NOS 17.03 , 17.04 , 17.05 ,17.06,17.08, 17.09 , 17.10 & 17.11 below:- (a) The quoted rates shall be deemed to include the following operations:- (i) Preventive and breakdown maintenance of all the equipments by regular oiling, greasing , changing of gland packing , replacement of nuts and bolts etc during the period of work order. (ii) To take care of house keeping and environmental cleanliness, area up to 5m all around installation shall be kept absolutely neat and clean. (iii) To maintain the installations provided under this contract as per IE rules/Standard Engineering practice. (iv) The cost of spare parts to be replaced for operation/maintenance of sewage treatment plant and Effluent Treatment Plant shall be borne by the contractor being the liability of the contractor during the currency of defect liability period as per conditions of the contract.The cost of Spares to be replaced for operation & maintenance of sewage plant shall also be borne by the contractor during Manning & Operation of STP & ETP for further 2 years period after defects liability period of 03 (Three) years (v) Periodical maintenance shall be carried out by the authorized representative of the original equipment manufacturer (OEM) of the plant. (vi) Electricity and water for operation of the plant will be supplied by the Department free of cost. (vii) operation of raw sewage pump, air blowers, fitter feed pump, dual media filter activate cabon filter (if applicable) , dosing system, ultra filtertion system (if applicable)& control panel. (viii) removing of material arrested at bar screen. (ix ) removing of oil floating at surface. (x) change over from one pump to another daily on requirement (xi) change over from one blower to another daily on requirement. (xii) cleaning of air filter of blower regularly on requirement basis. (xiii) Applying grease to all motors blowers periodically including supplying of suitable quality of grease as per site requirement (xiv) draining of sludge from MBBR reactor once in a month to avoid chocking of air grid (xv) removing of sludge from tube settler depending upon the actual load (xvi) maintaining of log books for records of operation of plants including cost of stationary (xvii) back wash of dual media filter and activate carbon filter weekly (xviii) screening of inlet & outlet mesh box of MBBR reactor weekly (xix) washing of tube media with low pressure jut of raw water required (xx) draining of burnout lubricant oil and refilling of appropriate lubricant oil in air blower after 2000-2500 hrs of operation including cost of lubricant (xxi) maintenacne and operation of filter press and collecting output neatly (xxii) operation of standby DG set st and when required
(xxiii) operating clear water pumps regularly and in consultation with Engr-in-charge. (xvi) maintaining of log books for records of operation of plants including cost of stationary. (xvii) back wash of dual media filter and activate carbon filter weekly. (xviii) screening of inlet & outlet mesh box of MBBR reactor weekly . (xix) washing of tube media with low pressure jut of raw water required . (xx) draining of burnout lubricant oil and refilling of appropriate lubricant oil in air blower after 2000-2500 hrs of operation including cost of lubricant (xxi) maintenacne and operation of filter press and collecting output neatly (xxii) operation of standby DG set st and when required (xxiii) operating clear water pumps regularly and in consultation with Engr-in-charge
Manning and operation of Sewage Treatment Plant of capacity 200 m3/day (200 KLD) including 62.5 KVA DG set & Effluent treatment plant capacity 50 m3/day (50KLD) installed and provided at MH Chennai, for 3 shifts of 8 hours each per day from certified date of completion of work by employing one well experienced operator in the trade and two helper in each shift of 08 hrs for operation of plant and carrying out daily, weekly, monthly,quarterly & half yearly maintenance as specified complete during the defect liability period of first year after physical completion , testing and commissioning of plant as specified. Note:- This item is to be operated after physical completion and commissioning of the ETP& STP.
Manning and operation of Sewage Treatment Plant of capacity 200 m3/day (200 KLD) including 62.5 KVA DG set & Effluent treatment plant capacity 50 m3/day (50KLD) installed and provided at MH Chennai, for 3 shifts of 8 hours each per day from certified date of completion of work by employing one well experienced operator in the trade and two helper in each shift of 08 hrs for operation of plant and carrying out daily, weekly, monthly,quarterly & half yearly maintenance as specified complete for remaining defect liability period of first year and second year .(Partly first year and partly second year). Note:- This item is to be operated after expiry of item no 17.03.
Manning and operation of Sewage Treatment Plant of capacity 200 m3/day (200 KLD) including 62.5 KVA DG set & Effluent treatment plant capacity 50 m3/day (50KLD) installed and provided at MH Chennai, for 3 shifts of 8 hours each per day from certified date of completion of work by employing one well experienced operator in the trade and two helper in each shift of 08 hrs for operation of plant and carrying out daily, weekly, monthly,quarterly & half yearly maintenance as specified complete for remaining defect liability period of third year .Note:- This item is to be operated after expiry of item no 17.04.
NOTE : The contractor's quoted rates for the item Nos 17.03 , 17.04 , 17.05 , 17.09 , 17.10 ,17.11,& 17.12 A.shall be deemed to include the cost of following also : (a) Maintain the internal and external area of plant. (b) Watch and ward and care of govt assets and equipments of the plant (c ) Maintain the safety and security measures of the plant (d) Keep the installation neat and tidy (e) Supply of suitable material/chemical for plant in appropiate quantity i.e chlorine solution,lubricant oil for air blowers,greases etc.. (f) Decision of GE shall be final and binding on account of quality and quantity of material /chemicals required for maintenance and operation of the plant. All materials brought at site record purpose duly indicated with relevant purchase vouchers and test certificates. (g) Disposal of treated sewage/sludge as directed by engr-in-charge. (h) HSD/DHPP shall be issued by the deptt free for consumption. (j) Efficient treatment of the sewage water shall be ensured by the contractor and required characterstics of outlet treated sewage shall be as under:- (i) Oil and grease-- ≤10ppm (ii) Suspended solid- ≤ 10 mg/Ltr (iii) BOD 5 <30 ppm (iv) COD- <300 ppm (v) PH - 6.5 to 8.5 (vi) Coliform count - 100 counts per 100 ml
B. Testing of treated water: The treated water shall be got tested by the tenderer once in a month from regional Govt.Lab/other approved lab. Samples shall be collected in the presence of engr-in-charge and test reports shall be submitted to engr-in-charge in original for record purpose.If parameters of tested water are beyond the limits mentioned above or contractor failed to carryout the required tests the recovery at double the quoted rates of the contractor for the entire month shall be made from the contractor. C. The recovery as follows to be made from payment of the contractor in the following exegency:- a) Operator found absent from duty @Rs.30/- per shift b) Not carrying out Testing of water sample @Rs.2500/- each c) Not maintaing log sheet/Log book @ 300/- per day d) Not maintaining designed parameters@Rs double the rate quoted rate per shiftby the contractor. D. Sludge from sludge drying beds shall be removed by the contractor outside defence land. The contractor shall consider the cost of credit of sludge and cost of removal of sludge in the per month rate of manning & Operation. Nothing extra shall be recovered / paid to the contractor on account of removal of sludge outside Defence land.
SCHEDULE 'A' PART XVI (MANNING AND OPERATION OF STP & ETP AFTER DEFECTS LIABILITY PERIOD)
Manning and operation of Sewage Treatment Plant of capacity 200 m3/day (200 KLD) including 62.5 KVA DG set & Effluent treatment plant capacity 50 m3/day (50KLD) installed and provided at MH Chennai, for 3 shifts of 8 hours each per day from certified date of completion of work by employing one well experienced operator in the trade and two helper in each shift of 08 hrs for operation of plant and carrying out daily, weekly, monthly,quarterly & half yearly maintenance as specified complete during the second year after physical completion of work in phase- I. Note:- This item is to be operated after completion of Item No. 17.05
Manning and operation of Sewage Treatment Plant of capacity 200 m3/day (200 KLD) including 62.5 KVA DG set & Effluent treatment plant capacity 50 m3/day (50KLD) installed and provided at MH Chennai, for 3 shifts of 8 hours each per day from certified date of completion of work by employing one well experienced operator in the trade and two helper in each shift of 08 hrs for operation of plant and carrying out daily, weekly, monthly,quarterly & half yearly maintenance as specified complete during third year (partly) after physical completion of work in Phase-I Note:- This item is to be operated after expiry of item no 17.09
Manning and operation of Sewage Treatment Plant of capacity 200 m3/day (200 KLD) including 62.5 KVA DG set & Effluent treatment plant capacity 50 m3/day (50KLD) installed and provided at MH Chennai, for 3 shifts of 8 hours each per day from certified date of completion of work by employing one well experienced operator in the trade and two helper in each shift of 08 hrs for operation of plant and carrying out daily, weekly, monthly,quarterly & half yearly maintenance as specified complete during fourth year (partly) after physical completion of work in Phase-I Note:- This item is to be operated after expiry of item no 17.10
Manning and operation of Sewage Treatment Plant of capacity 200 m3/day (200 KLD) including 62.5 KVA DG set & Effluent treatment plant capacity 50 m3/day (50KLD) installed and provided at MH Chennai, for 3 shifts of 8 hours each per day from certified date of completion of work by employing one well experienced operator in the trade and two helper in each shift of 08 hrs for operation of plant and carrying out daily, weekly, monthly,quarterly & half yearly maintenance as specified complete for remaining defect liability period of fifth year and Sixth year .(Partly fourth year and Fifth year).
Electromech Engineers
Chandel Construction Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .