| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹30.4 LAccepted-AOC SHOP NO 33 GOPI NATH BAZAR DELHI CANTT 10 | DELHI CANTT | NEW DELHI | DELHI | 110010 | 1 | Accepted-AOC ACCEPTED BEING L1 | |
| 2 | 2₹33.1 L+₹2.7 L (8.94%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | 2 | Rejected-Finance REJECTED BEING NOT L1 | |
| 3 | 3₹34.8 L+₹4.5 L (14.7%)Rejected-Finance HOUSE NO 142 GALI NO 07 PREM VIHAR NANGLI SAKRAWATI NAJAFGARH NEW DELHI 110043 | NEW DELHI | NAJAFGARH | DELHI | 110043 | 3 | Rejected-Finance REJECTED BEING NOT L1 | |
| 4 | 4₹36.6 L+₹6.2 L (20.4%)Rejected-Finance | 4 | Rejected-Finance REJECTED BEING NOT L1 | |
| 5 | 5₹39.1 L+₹8.7 L (28.6%)Rejected-Finance RZ 212F D BLOCK RAJ NAGAR PART II PALAM COLONY NEW DELHI 110077 | SOUTH WEST | DELHI | 110077 | 5 | Rejected-Finance REJECTED BEING NOT L1 |
| Sl No | Description | Qty | Unit | Vijay Electricals L8 | mayur enterprises L6 | M/s JAIMAA ASSOCIATES L1 | Commercial Traders L2 | MV Engineers And Contractors L5 | DS CONSTRUCTION L4 | M P TYAGI ENGINEERS AND CONTRACTORS L7 | S K ENGINEERS AND CONTRACTOR L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for servicing /testing of breaker/control panel including CT/ PT and relays in control panel of VCB of capacity 630-800 Amps and rating 11 KV complete as details mentioned as under :- (a) Details of servicing of breaker :-
(i) Adjustment of mechanism if required.
(ii) Clean the circuit breaker to remove dust and dirt. The envelope of the vacuum interrupter and insulating materials shall be wiped with a clean cloth.
(iii) Apply a small amount of oil to rotary sections, sliding surfaces, pins, coupling section, etc.use grease for the operating shaft and bearings, and machine oil for other parts.
(iv) Check for rust and wear.
(v) Check Spring Tension and pitting of the Cluster Contacts.
(vi) Visual check for rust and deformation. (vii) Check for loosened bolts and nuts, broken spring washers and snap pins etc.
(viii) Check for loosened connections, rust, damaged lead wires.
(ix) Check whether the contacts are damaged by arcing.
(x) Checking of control circuit & tighten the connections if any.
(xi) Check close & trip coil.
(xii) Checking of Jaw Contacts Conditions and repair/adjust.
(xiii) Replace the jaw contacts,If required.
(xiv) Improvement of resistance of epoxy insulator and epoxy body by applying post heated varnish.
(xv) Replacement of Dashpot/shock absorbers .
(xvi) Replacement of carbon brush of spring charging motor
(xvii) Checking, cleaning, tightening , testing the busbars incl bus chambers,support insulator, Spouts, CT/PT etc.
(b) The following test shall be carried out:-
(i) Primary Injection Test of CT / PT
(ii) Closing & Opening Timing Test for all three poles.
(iii) IR Test with megger in open and closed condition. | 26 | Each Job | 12,000 ₹3,12,000 | 3,000 ₹78,000 | 5,000 ₹1,30,000 | 1,000 ₹26,000 Lowest | 4,500 ₹1,17,000 | 8,000 ₹2,08,000 | 10,000 ₹2,60,000 | 4,900 ₹1,27,400 |
| 1.01(c) Testing of following relays of control panel with Secondary Injection Kit ,checking and programming of relay : -(i) Over current and earth fault relay (d) Testing of followig Aux relay (i) DC Supply supervision relay. (ii) Master trip relay | |||||||||||
| 2.00 | Supplying, installation, commissioning and testing in replacement of 11 KV Current Transformer (CT`s), indoor type, resin cast epoxy type, of 13.1 KA/Sec having ratio 200/100/5-5 Amps having Core1: Class 5P10, 10VA for protection , Core2: Class 0.5, 10VA for metering including associated wiring complete all as specified and directed by Engr-In-Charge. | 1 | Set of 3 | 3,800 ₹3,800 Lowest | 15,000 ₹15,000 | 9,000 ₹9,000 | 15,000 ₹15,000 | 15,000 ₹15,000 | 15,000 ₹15,000 | 5,000 ₹5,000 | 16,000 ₹16,000 |
| 3.00 | All as per item No 2 here-in-before but having ratio 150/75/5-5 Amp | 3 | Set of 3 | 3,800 ₹11,400 Lowest | 15,000 ₹45,000 | 9,000 ₹27,000 | 15,000 ₹45,000 | 15,000 ₹45,000 | 15,000 ₹45,000 | 5,000 ₹15,000 | 16,900 ₹50,700 |
| 4.00 | All as per item No 2 here-in-before but having ratio 100/50/5-5 Amp | 3 | Set of 3 | 3,800 ₹11,400 Lowest | 15,000 ₹45,000 | 9,000 ₹27,000 | 15,000 ₹45,000 | 15,000 ₹45,000 | 15,000 ₹45,000 | 5,000 ₹15,000 | 17,900 ₹53,700 |
| 5.00 | Supplying, installation, commissioning and testing in replacement of PT unit three phase, three limbs, upto 11 KV draw-out type, resin cast dry type, single ratio having primary voltage 11 KV & secondary voltage 110 volts, 50 VA class-1 including necessary bus bar connections & wiring for metering complete all as specified and directed by Engr In Charge. | 4 | Set of 03 | 6,000 ₹24,000 | 22,000 ₹88,000 | 28,000 ₹1,12,000 | 40,000 ₹1,60,000 | 25,000 ₹1,00,000 | 35,000 ₹1,40,000 | 5,000 ₹20,000 Lowest | 19,000 ₹76,000 |
| 6.00 | S&F in replacement of LED indication lamp 24/110 Volts for breaker ON/OFF/TRIP/Breaker Spring Charged/R-Y-B etc for 11 KV control panel including associated wiring, if reqd, complete all as specified and directed by Engr In Charge. | 15 | Set of 03 | 1,000 ₹15,000 | 220 ₹3,300 | 300 ₹4,500 | 150 ₹2,250 | 100 ₹1,500 Lowest | 200 ₹3,000 | 100 ₹1,500 Lowest | 100 ₹1,500 Lowest |
| 7.00 | Supply and installation in replacement Anti-condensation space-heater withThermostatic control in cable and circuit breaker compartments of HT switchgears complete all as specified and directed by Engr-In-Charge. | 10 | Each | 700 ₹7,000 | 2,000 ₹20,000 | 800 ₹8,000 | 600 ₹6,000 | 500 ₹5,000 | 500 ₹5,000 | 200 ₹2,000 Lowest | 2,200 ₹22,000 |
| 8.00 | S&F in replacement of isolating contact assembly suitable for 630/800 amps, 11 KV HT VCB complete all as specified and directed by Engr-In-Charge. | 5 | Each | 600 ₹3,000 Lowest | 2,200 ₹11,000 | 1,800 ₹9,000 | 750 ₹3,750 | 1,500 ₹7,500 | 1,500 ₹7,500 | 1,000 ₹5,000 | 990 ₹4,950 |
| 9.00 | S&F in replacement of fixed contact block complete suitable for 630/800 amps, 11 KV HT VCB complete all as specified and directed by Engr In Charge. | 5 | Each | 600 ₹3,000 Lowest | 2,200 ₹11,000 | 1,800 ₹9,000 | 750 ₹3,750 | 1,500 ₹7,500 | 1,500 ₹7,500 | 1,000 ₹5,000 | 1,290 ₹6,450 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
5 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITY ELECTRIC SUPPLY
GE UTILITY ELECTRIC SUPPLY DELHI CANTT-10
REPAIR AND MAINTENANCE OF 11 KV SWITCHGEARS, 11 KV CABLE / DISTRIBUTION SYSTEM WITH PROTECTION SYSTEM WITH ALLIED WORKS AT KABUL LINE, BAIRD PLACE, KOTWALI LINE, CEDZ OFFICE, CDA (ARMY) AND ASSOCIATED AREA OF AGE (SLDC) E/S UNDER GE (U) ELECT SUPPLY
2025_MES_712626_1
GE ELECT/D-06/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE UTILITY ELECTRIC SUPPLY
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
Yes
GE UTILITY ELECTRIC SUPPLY
₹96,000
Yes
2 Sept 2025
7 Jun 2025
7 Jul 2025
7 Jun 2025
5 Jul 2025
21 Jun 2025
Amount
M&L for servicing /testing of breaker/control panel including CT/ PT and relays in control panel of VCB of capacity 630-800 Amps and rating 11 KV complete as details mentioned as under :- (a) Details of servicing of breaker :- (i) Adjustment of mechanism if required. (ii) Clean the circuit breaker to remove dust and dirt. The envelope of the vacuum interrupter and insulating materials shall be wiped with a clean cloth. (iii) Apply a small amount of oil to rotary sections, sliding surfaces, pins, coupling section, etc.use grease for the operating shaft and bearings, and machine oil for other parts. (iv) Check for rust and wear. (v) Check Spring Tension and pitting of the Cluster Contacts. (vi) Visual check for rust and deformation. (vii) Check for loosened bolts and nuts, broken spring washers and snap pins etc. (viii) Check for loosened connections, rust, damaged lead wires. (ix) Check whether the contacts are damaged by arcing. (x) Checking of control circuit & tighten the connections if any. (xi) Check close & trip coil. (xii) Checking of Jaw Contacts Conditions and repair/adjust. (xiii) Replace the jaw contacts,If required. (xiv) Improvement of resistance of epoxy insulator and epoxy body by applying post heated varnish. (xv) Replacement of Dashpot/shock absorbers . (xvi) Replacement of carbon brush of spring charging motor (xvii) Checking, cleaning, tightening , testing the busbars incl bus chambers,support insulator, Spouts, CT/PT etc. (b) The following test shall be carried out:- (i) Primary Injection Test of CT / PT (ii) Closing & Opening Timing Test for all three poles. (iii) IR Test with megger in open and closed condition.
(c) Testing of following relays of control panel with Secondary Injection Kit ,checking and programming of relay : -(i) Over current and earth fault relay (d) Testing of followig Aux relay (i) DC Supply supervision relay. (ii) Master trip relay
Supplying, installation, commissioning and testing in replacement of 11 KV Current Transformer (CT`s), indoor type, resin cast epoxy type, of 13.1 KA/Sec having ratio 200/100/5-5 Amps having Core1: Class 5P10, 10VA for protection , Core2: Class 0.5, 10VA for metering including associated wiring complete all as specified and directed by Engr-In-Charge.
All as per item No 2 here-in-before but having ratio 150/75/5-5 Amp
All as per item No 2 here-in-before but having ratio 100/50/5-5 Amp
Supplying, installation, commissioning and testing in replacement of PT unit three phase, three limbs, upto 11 KV draw-out type, resin cast dry type, single ratio having primary voltage 11 KV & secondary voltage 110 volts, 50 VA class-1 including necessary bus bar connections & wiring for metering complete all as specified and directed by Engr In Charge.
S&F in replacement of LED indication lamp 24/110 Volts for breaker ON/OFF/TRIP/Breaker Spring Charged/R-Y-B etc for 11 KV control panel including associated wiring, if reqd, complete all as specified and directed by Engr In Charge.
Supply and installation in replacement Anti-condensation space-heater withThermostatic control in cable and circuit breaker compartments of HT switchgears complete all as specified and directed by Engr-In-Charge.
S&F in replacement of isolating contact assembly suitable for 630/800 amps, 11 KV HT VCB complete all as specified and directed by Engr-In-Charge.
S&F in replacement of fixed contact block complete suitable for 630/800 amps, 11 KV HT VCB complete all as specified and directed by Engr In Charge.
S&F in replacement of moving contact block complete suitable for 630/800 amps, 11 KV HT VCB complete all as specified and directed by Engr In Charge.
S&F in replacement of spring bearing gear suitable for 630/800 amps, 11 KV HT VCB complete all as specified and directed by Engr In Charge.
S&F in replacement of closing coil assembly 24 volts DC suitable for 630/800 amps, 11 KV HT VCB complete all as specified and directed by Engr In Charge.
S&F in replacement of tripping coil assembly 24 volts DC suitable for 630/800 amps, 11 KV HT VCB complete all as specified and directed by Engr In Charge.
S&F in replacement close/trip coil 24V DC for 11 KV HT VCB of capacity 630/800 Amps capacity complete all as specified and directed by Engr-In-Charge.
S&F in replacement of panel door lock suitable for 400/630/800 amps, 11 KV HT VCB complete all as specified and directed by Engr In Charge.
S&F in replacement auxillary switch (7 No + 7NC) suitable for 630/800 amps, 11 KV HT VCB complete all as specified and directed by Engr In Charge.
S&F in replacement TNC Switch for Breaker ON/OFF purpose in HT 11 KV VCB panel including associated wiring, if reqd, for proper functioning of switch complete all as specified and directed by Engr In Charge.
S&F in replacement support rod with screws suitable for 630/800 amps, 11 KV HT VCB complete all as specified and directed by Engr In Charge.
S&F in replacement support insulator suitable for 630/800 amps, 11 KV HT VCB complete all as specified and directed by Engr In Charge.
S&F in replacement upper connector suitable for 630/800 amps, 11 KV HT VCB complete all as specified and directed by Engr In Charge.
S&F in replacement lower connector suitable for 630/800 amps, 11 KV HT VCB complete all as specified and directed by Engr In Charge.
S&F in replacement only set of 6 Nos fixed arcing contacts suitable for 630/800 amps, 11 KV HT VCB complete all as specified and directed by Engr In Charge.
S&F in replacement Caution plate “CAUTION MEN AT WORK of size 40cmx15cm made out of white acrylic sheet with Red coloured glow tape complete all as specified and directed by Engr In Charge. NOTE :- Sample kept in Engr-in-charge's office.
S&F in replacement of HRC fuse of capacity 20 Amps for VCB complete all as specified and directed by Engr In Charge.
S&F in replacement MCB 20 to 32 Amps SP , curve 'B' complete all as specified and directed by Engr In Charge.
S&F in replacement of Digital Volt meter Secondary voltage 110 V for 11 KV VCB Control Panel complete all as specified and directed by Engr In Charge. Note for item no-26 & 27:- The volt meter/ Amp meter shall be fixed on new 3 mm thick backlite sheet suitable size covering all blank space or cutting the sheet of panel for installation the same (if necessary).
Supplying, fixing, testing of PT fuse failure relay, 110 Volt AC in control panel including wiring complete all as specified and directed by Engr-In-Charge.
Supplying, fixing, testing of HT fuse failure relay, 110 Volt AC in control panel including wiring complete all as specified and directed by Engr In Charge.
Supply, installation and testing of Numerical Relay draw out type in replacement of any type, in HT 11 KV VCB Panel comprising of new and modern numerical scheme for detecting, indicating and tripping the breaker on faults over-current and earth-fault in any of the three phases, Trip circuit supervision relay, 5% pick up for OC and 5% for EF. The relay shall also have the following features as minimum; (i) Programmable rated current 1A & 5A, (ii) Last 8 fault record & 200 event record with time stamping, (iii) 4 analog input, 8 DI & 4 DO, (iv) Communicable on IEC61850 protocol, (v) Disturbance recording upto 300 cycles, (vi) Self supervision function. The relay shall be fully integrated with the feeder, internally capturing feeder statuses if available including Breaker On, Off, Spring Chrgd, Test, Service, AC-Fail, DC supervision relay, Trip circuit healthy relay, inter panel tripping, Master trip relay, local remote and display the same locally on a built-in LCD screen and suitably labeled status LEDs. Relay shall have facility to locally Trip/Close the breaker as a backup to TNC switch provided separately on the panel. The relay shall be fixed on new 2mm CRCA sheet of matching existing VCB panel color and suitable size covering all blank space formed by removing old mechanical type IDMT relay or any type complete including associated wiring and integration with existing HT VCB panel complete all as specified and directed by Engr In Charge.
Supply installation & commissioning in replacement of 24V/40A Float Cum Boost Battery Charger unit including battery bank comprising 12 Nos of 2 Volts-120 AH sealed maintenance free battery. The CCCV battery charger consisting of copper wound, air cooled transformer, 01 Set single phase full wave bridge rectifier consisting of diodes and SCRs, liberally rated mounted on heat sink and complete with resistor/condenser network for surge supperssion . During auto float mode automatic changeover shall take place from float mode to boost mode and vice versa, 01 Set of solid state constant potential controller to stabilize the DC output voltage of the float cum boost charger, 01 No electronic controller , DC digital ammeter , DC digital voltmeter, Potentiometer , DC, MCB for reverse battery protection . The charger should have alarm annunciation with visual and audible alarm with manual reset facility for fuse fail alarm. Float cum boost battery charger and DC distribution board shall be housed in powder coated sheet steel cubicle with panels of 1.6mm thickness , louvers for ventilation , gland plate will be provided for cable entry from bottom . The battery charger shall be divided into two compartments. The upper compartment shall house the battery charger & DCDB with all necessary controls. The lower compartment shall be suitable for housing the batteries. Tech specification shall be as under:- (a) Input working voltage-180 -270 Volts (b) Nominal Input Voltage - 230 V , AC , 50 Hz,1 (c) On load input power factor - > 0.8 (d) On load unit watt efficiencies-> 80% (e) No load losses of complete charge-< 10% (f) Ripple contents on the load (RMS)= 1% to 5% (g) Over load - 110% for 30 minutes and will give visual indication for over load condition. (h) Boost charging - 2.4 V/Cell . (j) Float charging -2.15 V/Cell (k) Float cum boost charging-Automatically changes from one state to another state as per battery condition and will give the visual indication for either float or boost based on charging mode. (l) Reverse polarity -No damage will caused . A visual indication for reverse polarity will appear with an audio alarm.
(m) Short circuit-MCB protecton provided. Make of battery charger :- Statcon/Sinetrac/Amar Raja Make of batteries :- Exide/Amaron/Okaya
M&L for excavation in trenches not exc. 1.5 m wide and not exc 1.5 m deep in soft/loose soil) for laying of cables or GI pipe and getting out including levelling of bottom suface to required level complete all as specified and directed by Engr In Charge.
M&L for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified and directed by Engr In Charge.
Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1, flat size 300mmx 180mm x 40mm complete all as specified and directed by Engr In Charge.
M&L for returning filling in,. including spreading, levelling, watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and directed by Engr-In-Charge.
M&L for removing excavated material (ie soil) from site to a distance n. exc 50 m away and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed by Engr-In-Charge.
Supplying, laying, testing and connecting in replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade, IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches / ducts / encased in GI pipe / fixed to pole or against re-routing / diversion from residential buildings / road / footpath etc complete all as specified and directed by Engr In Charge, including jointing & testing complete all as specified and directed by Engr-In-Charge of following sizes:-
95 sqmm 3 core
120 sqmm 3 core
150 sqmm 3 core
185 sqmm 3 core
M&L for boring of hole under road/pavement/hard standing or any other situation by mannual means and suitable for passing of GI pipe 80 to 100 mm bore and making good both ends complete all as specified and directed by Engr-In-Charge.
Supply and laying GI pipe light grade in replacement as cable protection laid on trench/floor, fixed on pole/wall etc of size100 mm dia complete all as specified and directed by Engr-In-Charge.
All as per item No 39.00 above but of size 80 mm dia complete all as specified and directed by Engr-In-Charge.
S&F of Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size :-
95 Sqmm 3 core.
120 Sqmm to 185 Sqmm, 3 core.
S&F of Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size :-
95 Sqmm 3 core.
120 Sqmm to 185 Sqmm, 3 core.
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size :-
95 Sqmm 3 core.
120 Sqmm to 185 Sqmm, 3 core.
S&F in replacement for Danger Notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bobes in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT, 25x20 cm size including taking down old one complete all as specified and directed by Engr-In-Charge.
M&L for painting with two coats of superior aluminium/smoke grey paint or as existing including necessary preparation of surfaces of steel fencing by brushing/cleaning complete with steel structure/wire mesh/frame/ gate for 11 KV transformer/ HT panels/Sub Station complete all as specified and directed by Engr-In-Charge.
M&L for PCC 1:3:6 (type C2) using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed by Engr-In-Charge.
Suplying and laying as replacement in sub station fixing 3.3 to 11 KV electrical insulation mat of size 5 mtr x 1 mtr x 2.5 mm thick specification as per IS 15652 2006 complete all as specified and directed by Engr-In-Charge.
M&L for earthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to GI Strip 32 mm x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanised ironside complete all as specified, including testing and commissioning complete all as specified and directed by Engr-In-Charge. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 15 mm bore GI pipe medium grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.
M&L for cutting and removing grass, vegetation bushes etc from surrounding 4 pole/6 pole HT structure, outside area of HT installation and removing all rubbish to a distance not exceeding 50 m complete all as specified and directed by Engr-In-Charge.
M&L for spreading of stone aggregate of nominal size not more than 40 mm at the bay/yard manually without damaging any equipments, cable or parts of the 33 KV Grid bays, spreading & levelling of finished gravel uniformaly in layers n. exc. 15 cm thick watered and rammed to true surface complete all as specified and directed by Engr-In-Charge.
S&F in replacement of Cross arms, bracings, supports, clamps and back plates or surge tower of fabricated from structural steel sections including nuts, bolts, washers,welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint, complete all as specified and directed by Engr-In-Charge.
M&L for brick work for sub class 'B' bricks straight or cruved on plan exc 6 mtr mean radius built in cement mortor 1:4 complete all as specified and directed by Engr-In-Charge.
M&L for Cement Concrete type C-1 mix, 1:3:6 (20mm graded aggregate) finishing the top surfaces fair and even complete all as specified and directed by Engr-In-Charge.
S&F in replacement 4 mm dia MS wire 75 x 75 mm mesh, made upto into mattress or cages appx 1.8 to 2.0 mtr height and fixed with flat iron/angle as per existing by welding in position complete all as specified and directed by Engr-In-Charge.
M&L for two coats of synthetic enamel paint of silver colour on steel surfaces over a coat of red oxide primer including preparation of surfaces complete all as specified and directed by Engr-In-Charge.
M&L for preparation of painted surface of floor mounted HT control panel for fixing of FLOURCENT REFELCTIVE LETTERING as follows of approved colours by Engr-In-Charge. (a) Re-write the details of HT Control panel,O/G, I/C fedeers, Sl No of HT Panel, CTR etc on the HT panels in capital letters of size not less than 40 mm width and 50 mm height and works not exceeding 70 letters per panel. (b) Numbering of the HT Panels in both front and back side of size not less than 80 mm width and 80 mm height. Name of HT Control panel,O/G, I/C fedeers should be written on backside of HT Panels also as size mentioned para (a) above complete all as specified and directed by Engr-In-Charge.
S&F in wall of sub stn, in replacement of Exaust Fan of size 450 mm sweep, 1400 RPM, copper wounded with MS blade complete with louver all as specified and directed by Engr-In-Charge.
M&L for dismantling the existing unserviceable (damaged/broken) PCC 4/2 pole electric pole structure of any type and size, from ground after necessary excavation & breaking of concrete foundation & encasing the pole including making good the disturbed surfaces complete all as specified and directed by Engr-In-Charge.
(iv) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt. II/1993 (Latest Version). The MCCB should have Ics=100% Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacture.
Note : Contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Engr-in-charge.
Commercial Traders (BID ID -3339875)
S K ENGINEERS AND CONTRACTOR (BID ID -3340147)
DS CONSTRUCTION (BID ID -3347804)
MV Engineers And Contractors (BID ID -3340187)
mayur enterprises (BID ID -3339821)
M P TYAGI ENGINEERS AND CONTRACTORS (BID ID -3333729)
Vijay Electricals (BID ID -3339641)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .