Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.3 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹45.2 L+₹82,788 (1.87%)Rejected-Finance FLAT NO 201 GREEN VALLEY CHS PLOT NO 26 SECTOR 19 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L2 | Rejected-Finance NOT ADMITTED BEING L2 | |
| 3 | L3₹50.4 L+₹6.1 L (13.7%)Rejected-Finance GARDEN AVENUE PLOT NO 242 243 244 RH 4 SECTOR 21 NERUL NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L3 | Rejected-Finance NOT ADMITTED BEING L3 | |
| 4 | L4₹55.7 L+₹11.4 L (25.7%)Rejected-Finance | L4 | Rejected-Finance NOT ADMITTED BEING L4 | |
| 5 | Rejected-Technical | - | Rejected-Technical NOT ADMITTED DUE NOT ENLISTED IN b i CATEGORY |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
13 Nov 2023, 6:00 pmClosed
GE NW KARANJA
NAVAL STATION KARANJA, URAN, RAIGAD, MAHARASHTRA
PREVENTIVE MAINTENANCE OF DG SET AND CONTROL PANEL INCLUDING REPAIR REPLACEMENT OF DISPLAY BOARD AND PAINTING OF MACHINERIES IN NAD EXPLOSIVE AND NON EXPLOSIVE AREA TUNIR AND COMMON AREA AT NAVAL STATION KARANJA
2023_MES_623391_1
8742/E8
Open Tender
Electrical and Maintenance Works
Item Rate
GE NW KARANJA
D and above b i
8 documents required · 8 mandatory
₹500
Yes
GE NW KARANJA
₹98,000
Yes
23 Dec 2023
16 Oct 2023
15 Nov 2023
16 Oct 2023
13 Nov 2023
30 Oct 2023
Amount
Notes : (i) The work consists of 01 job as under:- JOB (A) : TPP 23-24 Ser No. 60 (ii) Please refer schedule 'A' notes before quoting the tender. (iii) Amount of Schedule of Credit shall be deducted off line by the department. ITEMS FOR JOB 'A'
Servicing for capcity 250 KVA MAKE KIRLOSKAR , NTA 855 G FFC ENGINE installed at JETTY S/S -01 No,R550 S/S , drain out engine oil from sump,cleaning and filling up with new engine oil as per recommended grade & quality & including repair/ replacement of following worn out spare parts for smooth running at rated speed complete all as manufacture specification & better performance complete all as specified and directed.
SUPPER BYPASS HOSE (Cat Pt AK601200SS or equivalent as approved by GE)
SUPPER BYPASS HOSE (Cat Pt AK604200SS or equivalent as approved by GE)
OIL PAN GASKET (Cat Pt 178788 or equivalent as approved by GE)
OIL SUCTION TUBE O RING (Cat Pt 178937 or equivalent as approved by GE)
OIL SUCTION TUBE GASKET (Cat Pt 15751 or equivalent as approved by GE)
B' CHECK KIT (Cat Pt 328536 or equivalent as approved by GE)
AIR CLEANER ELEMENT (Cat Pt 4055283 or equivalent as approved by GE)
MAKE UP HOSE (Cat Pt 505062 or equivalent as approved by GE)
MAKE UP HOSE CLAMP (Cat Pt 43828 or equivalent as approved by GE)
BYPASS HOSE (Cat Pt 63495 or equivalent as approved by GE)
BYPASS HOSE CLAMP (Cat Pt 125742 or equivalent as approved by GE)
BARREL & PLUNGER (Cat Pt KT3880783 or equivalent as approved by GE)
VENT HOSE (Cat Pt AK050480SS or equivalent as approved by GE)
DIESEL SUPPLY HOSE (Cat Pt AK100240SS or equivalent as approved by GE)
DIESEL SUPPLY HOSE (Cat Pt AK100720MS or equivalent as approved by GE)
RPM MATER (Cat Pt 501151 or equivalent as approved by GE)
TECH CABLE (Cat Pt 500185 or equivalent as approved by GE)
SHUT DOWN VALVE (Cat Pt 3239599 or equivalent as approved by GE)
FAN BELT (Cat Pt 178611 or equivalent as approved by GE)
WATER PUMP BELT (Cat Pt 200238 or equivalent as approved by GE)
ALTERNATOR BELT (Cat Pt 3040349 or equivalent as approved by GE)
STARTING KEY SWITCH (Cat Pt 504975 or equivalent as approved by GE)
PUSH BUTTON (Cat Pt 504395 or equivalent as approved by GE)
All as per item No 1.01above but DG set capcity 250 KVA, CUMMINS NTA 855 G ENGINE installed at A 244 S NAD Explosive area complete all as specified and directed.
OIL PRESSURE GAUGE (Cat Pt 500109 or equivalent as approved by GE)
OIL SUCTION TUBE O RING (Cat Pt 3010157 or equivalent as approved by GE)
VALVE INTAKE (Cat Pt 3000926 or equivalent as approved by GE)
VALVE EXHAUST (Cat Pt 145701 or equivalent as approved by GE)
BARREL & PLUNGER KIT (Cat Pt 324528 or equivalent as approved by GE)
BYPASS HOSE (Cat Pt 63495 or equivalent as approved by GE)
BYPASS HOSE CLAMP (Cat Pt 125742 or equivalent as approved by GE)
FAN BELT (Cat Pt 178611 or equivalent as approved by GE)
WATER PUMP BELT (Cat Pt 200238 or equivalent as approved by GE)
ALTERNATOR BELT (Cat Pt 3040349 or equivalent as approved by GE)
STARTING KEY SWITCH (Cat Pt 50497 or equivalent as approved by GE)
PUSH BUTTON (Cat Pt 504395 or equivalent as approved by GE)
SILENCER
CYL HEAD SERVICING (Cat Pt SAC 998717 or equivalent as approved by GE)
P.T. PUMP CALIBRATION WITH PARTS (Cat Pt SAC 998717 or equivalent as approved by GE)
TURBO REPAIR CHARGESS (Cat Pt SAC 998717 or equivalent as approved by GE)
INJECTOR CALIBRATION WITH PARTS
All as per item No 1.01 above but Dg set capcity 400 KVA ,GREEVES TBD 3 V 12 MK 1 ENGINE installed at MRF S/S complete all as specified and directed.
TURBO CHARGER REPAIR KIT (Cat Pt 10697210008 or equivalent as approved by GE)
AIR FILTER OUTER ELEMENT (Cat Pt 105413100102 or equivalent as approved by GE)
AIR FILTER INNER ELEMENT (Cat Pt 105413100103 or equivalent as approved by GE)
WATER PUMP PULLY
SPARES REQUIRE FOR PMUP/NOZZLE CALIBRATION
DIESEL FILTER (Cat Pt 00240911 or equivalent as approved by GE)
DIESEL FILTER (Cat Pt 00240912 or equivalent as approved by GE)
OIL FILTER (Cat Pt 873 or equivalent as approved by GE)
AIR CLEANER (OUTER) [Cat Pt 501310102 or equivalent as approved by GE]
AIR CLEANER (INNER) [Cat Pt 501310103 or equivalent as approved by GE]
S&F in replacement of the following various Diesel filter of DG capacity 50 KVA to 500 KVA complete all as specified and directed :
Diesel filter (Cat Pt 3238943 or equivalent as approved by GE)
Diesel filter (Cat Pt 48.999.20.0.00 or equivalent as approved by GE)
Diesel filter (Cat Pt DV0.020.30.0.0 or equivalent as approved by GE)
Diesel filter (Cat Pt F002H20306 or equivalent as approved by GE)
Diesel filter (Cat Pt 605411880008 or equivalent as approved by GE)
Diesel filter (Cat Pt 4962810 or equivalent as approved by GE)
All as per item No 1.01 above but DG set capcity 75 KVA, 6 BT 5.9 G 1 ENGINE installed at Aradhana complete all as specified and directed.
FUEL FILTER (Cat Pt 3931063 or equivalent as approved by GE)
LUB OIL FILTER (Cat Pt 3933743 or equivalent as approved by GE)
WATER SEPARATOR
AIR CLEANER SET
All as per item No 1.01 above but DG set capcity 110 KVA, KIRLOSKAR GREEN ( 6 R 1080 TA ) installed at 36 Lt cdr complete all as specified and directed.
Expansion bellow
Diesel filter (Cat Pt 48.117.01.0.00 or equivalent as approved by GE)
Diesel filter (Cat Pt 48.117.02.0.00 or equivalent as approved by GE)
oil filter spinon (Cat Pt 06.436.01.0.00 or equivalent as approved by GE)
Diesel supply hose
Diesel return hose
Air filter (Cat Pt 6H.411.02.00 or equivalent as approved by GE)
Fan belt
All as per item No 1.01 above but DG set capcity 125 KVA, 6 R 1080 TA ENGINE installed at 84 leading complete all as specified and directed.
DIESEL FILTER (Cat Pt F002H20306 or equivalent as approved by GE)
OIL FILTER (Cat Pt 06.436.01.0.00 or equivalent as approved by GE)
AIR FILTER PRIME (Cat Pt 6H411.01.0.00 or equivalent as approved by GE)
AIR FILTER SECON (Cat Pt 6H411.02.0.00 or equivalent as approved by GE)
DOOR HINGES LEFT & RIGHT
TURBO CHARGER
All as per item No 1.01 above but Dg set capcity 125 KVA, Kirloskar 6 R 1080 TA ENGINE installed at Ac Store Accn , RMSF Chunabhatti & RMSF Proof house complete all as specified and directed.
HOSE THERMOSTATE TO RADIATOR (Cat Pt 6H.075.01.0.00 or equivalent as approved by GE)
CLAMP (Cat Pt 50519/11 or equivalent as approved by GE)
HOSE WATER PUMP TO RADIATOR (Cat Pt 6H.073.02.0.00 or equivalent as approved by GE)
ALTERNATOR (Cat Pt 46.390.01.0.00 or equivalent as approved by GE)
CAP ASSY(Cat Pt 34.036.60 or equivalent as approved by GE)
ROTARY SHAFT SEAL (Cat Pt 03.007.91.0.00 or equivalent as approved by GE)
STRTING RING (Cat Pt 03.035.02.0.00 or equivalent as approved by GE)
AIR FILTER (Cat Pt 6H.411.02.00 or equivalent as approved by GE)
FAN BELT
HOSE THERMOSTATE TO RADIATOR (Cat Pt 6H.075.01.0.00 or equivalent as approved by GE)
DIESEL FILTER (Cat Pt 48.117.01.0.00 or equivalent as approved by GE)
DIESEL FILTER (Cat Pt 48.117.02.0.00 or equivalent as approved by GE)
OIL FILTER SPINON (Cat Pt 06.436.01.0.00 or equivalent as approved by GE)
DIESEL SUPPLY HOSE
DIESEL RETURN HOSE
All as per item No 1.01 above but DG set capcity 110 KVA, Kirloskar 4 R 1080 TA ENGINE installed at (SM 39 ) Building no. 582, for NAD Depot area complete all as specified and directed.
Diesel filter (Cat Pt 48.117.01.0.00 or equivalent as approved by GE)
Diesel filter (Cat Pt 48.117.02.0.00 or equivalent as approved by GE)
oil filter spinon (Cat Pt 06.436.01.0.00 or equivalent as approved by GE)
Diesel supply hose
Diesel return hose
Air filter Cat Pt 6H.411.02.00 or equivalent as approved by GE
Fan belt
All as per item No 1.01 above but DG set capcity 200 KVA , CUMMINS NTA 743 G ENGINE installed at EKM complete all as specified and directed.
RADIATOR HOSE TOP (Cat Pt 67185 or equivalent as approved by GE)
RADIATOR HOSE CLAMP (Cat Pt 125741 or equivalent as approved by GE)
MAKE UP HOSE & CLAMPS ( Cat Pt 505062 or equivalent as approved by GE)
BYPASS HOSE (Cat Pt 63495 or equivalent as approved by GE)
BYPASS HOSE CLAMP (Cat Pt 125742 or equivalent as approved by GE)
C. R. HOSE & CLAMP
VENT HOSE (Cat Pt AK504800SS or equivalent as approved by GE)
ALTERNATOR BELT( Cat Pt 3040349 or equivalent as approved by GE)
GAUGE WATER TEMP (Cat Pt 500108R or equivalent as approved by GE)
GAUGE OIL TEMP(Cat Pt 500410 or equivalent as approved by GE)
GAUGE OIL PRESSURE (Cat Pt 500109 or equivalent as approved by GE)
RPM MATER (Cat Pt 501151 or equivalent as approved by GE)
ACC. DRIVE SEAL (Cat Pt 3004316 or equivalent as approved by GE)
SLINGER (Cat Pt 181236 or equivalent as approved by GE)
SEA KEY WAY (Cat Pt 3008947 or equivalent as approved by GE)
PULLY SLEEVE (Cat Pt 3008947 or equivalent as approved by GE)
BREATHER ASSY (Cat Pt 190397 or equivalent as approved by GE)
TURBO HUMP HOSE AT TURBO
TURBO HUMP HOSE AT TURBO AT AIR CLEANER
All as per item No 1.01 above but DG set capcity 625 KVA, CUMMINS VTA 28 G5-1 ENGINE , ESN. 25314131 installed at ATIME NAD NEW complete all as specified and directed.
TECHO CABLE
PRIMING PUMP
DIESEL FILTER WITH O RING
OIL FILTER WITH O RING
SUPER BYPASS FILTER WITH O RING
RADIATOR HOSE SET
CLAMP SET
AIR CLEANER HUMP HOSE
AIR CLEANER HUMP HOSE CLAMP
TURBO HUMP HOSE
TURBO HUMP HOSE CLAMP
VANT HOSE (Cat Pt AK 507200SS or equivalent as approved by GE)
All as per item No 1.01 above but Dg set capcity 400 KVA ,kirloskar ENGINE installed at sbm12/13/14 Road no 2 complete all as specified and directed.
Diesel filter (Cat Pt AK 1200240911 or equivalent as approved by GE)
Diesel filter (Cat Pt AK 1200240912 or equivalent as approved by GE)
Oil filter Cat Pt AK 8.873 or equivalent as approved by GE
Air cleaner ( Outer ) [Cat Pt AK 10501310102 or equivalent as approved by GE]
Air cleaner ( Inner) [Cat Pt AK 10501310103 or equivalent as approved by GE]
Fan Belt
Uniball Joint
Thermostate
Hose diesel ( 7 Ft. )
Diesel filter pump hose
Oil filter head gasket
RPM meter (Cat Pt AK 501151 or equivalent as approved by GE)
Radiator hose set
Clamp set
Oil pressure gauge
Water temp gauge
Oil pressure hose
water pump pullye
Running hours meter
All as per item No 1.01 above but Dg set capcity 625 KVA, CUMMINS installed at ATIME NAD NEW complete all as specified and directed.
DIESEL FILTER WITH O RING Cat Pt 3238493 or equivalent as approved by GE
OIL FILTER WITH O RING (Cat Pt 328204 or equivalent as approved by GE)
SUPER BYPASS FOLTER WITH O RING (Cat Pt 3879488 or equivalent as approved by GE)
AIR CLEANER ELEMENT (Cat Pt 4055283 or equivalent as approved by GE)
BREATHER RED HOSE
ELBOW HUMP HOSE WITH CLAMP
PUMP RETURN HOSE (Cat Pt AK601680SS or equivalent as approved by GE)
SUPER BYPASS HOSE (Cat Pt AK604800SS or equivalent as approved by GE)
SUPER BYPASS HOSE (Cat Pt AK606000SS or equivalent as approved by GE)
SUPER BYPASS HOSE (Cat Pt AK601200SS or equivalent as approved by GE)
SUPER BYPASS HOSE (Cat Pt AK603600SS or equivalent as approved by GE)
VENT HOSE (Cat Pt AK608400SS or equivalent as approved by GE)
DIESEL HOSE (Cat Pt AK100240SS or equivalent as approved by GE)
DIESEL HOSE (Cat Pt AK100192SS or equivalent as approved by GE)
HUMP HOSE with clamp (Cat Pt 3000303 or equivalent as approved by GE)
ELBOW HUMP HOSE WITH CLAMP
DIESEL TANK PIPE
All as per item No 1.01 above but DG set capcity 500 KVA, Kirloskar installed at DBM 12 13 complete all as specified and directed.
Lub oil filter (Cat Pt 605411880008 or equivalent as approved by GE)
Fuel pre filter 1 ltr (Cat Pt 1200240911 or equivalent as approved by GE)
Fuel micro filter 1 Ltr (Cat Pt 1200240912 or equivalent as approved by GE)
Air filter outer element (Cat Pt 105413100102 or equivalent as approved by GE)
AIR FILTER INNER ELEMENT (Cat Pt 105413100103 or equivalent as approved by GE)
Tappet Gasket
All as per item No 1.01 above but DG set capcity 400 KVA,KIRLOSKAR ENGINE installed at TAL complete all as specified and directed.
Fuel filter (Cat Pt F002.H22.004 or equivalent as approved by GE)
Oil filter (Cat Pt DVO.014.27.0 or equivalent as approved by GE)
Oil filter (Cat Pt DVO.011.00.0 or equivalent as approved by GE)
Diesel filter DVO (Cat Pt 002.H22.028 or equivalent as approved by GE)
Air filter (inner/Outer)
All as per item No 1.01 above but DG set capcity 500 KVA, KIRLOSKAR installed at PCB Repair complete all as specified and directed.
DIESEL FILTER WITH O RING
OIL FILTER WITH O RING
SUPER BYPASS FILTER WITH O RING
AIR CLEANER ELEMENT
OIL TEMP. GAUGE
WATER TEMP. GAGUE
OIL PRESSURE GAUGE
DIESEL SUPPLY HOSE
OIL SAFETY CONTROL
WATER SAFETY CONTROL
SHUT DOWN COIL
PUSH BUTTON
HERNESS WIRING SET
All as per item No 1.01 above but DG set capcity 500 KVA, KIRLOSKAR installed at KASTAN WORKSHOP complete all as specified and directed.
Fuel filter (Cat Pt F002.H22.004 or equivalent as approved by GE)
Oil filter (Cat Pt DVO.014.27.0 or equivalent as approved by GE)
Diesel filter DVO (Cat Pt 002.H22.028 or equivalent as approved by GE)
Air filter (inner/Outer)
Relay Board (Cat Pt 853.05.0.00 or equivalent as approved by GE)
Generator control (Cat Pt DVO.0901.13.0.0 or equivalent as approved by GE)
All as per item No 1.01 above but DG set capcity 200 KVA,CG TBD 3 V 6 VT 1710 G ENGINE installed at B SUB STATION complete all as specified and directed.
Fuel pre filter 1 ltr (Cat Pt 1200240911.00 or equivalent as approved by GE)
Fuel micro filter 1 Ltr (Cat Pt 1200240912.00 or equivalent as approved by GE)
INSTAKOOL COOLANT
GROOVE NUT (Cat Pt 623403600014.00 or equivalent as approved by GE)
INJECTOR SLEEVE (Cat Pt 623403600044.00 or equivalent as approved by GE)
RING/INJ SLEEVE WASHER (Cat Pt 623403400174.00 or equivalent as approved by GE)
INJECTOR SLEEVE O RING (Cat Pt 604931302404.00 or equivalent as approved by GE)
COPPER WASHER 6 MM (Cat Pt 604931302404.00 or equivalent as approved by GE)
INJECTOR SEALING RING (Cat Pt 622223408550044.00 or equivalent as approved by GE)
COPPER SLEEVE BIG (Cat Pt 623403300124.00 or equivalent as approved by GE)
TURBO CHARGER REPAIR KIT (Cat Pt 106907210008.00 or equivalent as approved by GE)
AIR FILTER OUTER ELEMENT ( Cat Pt 106900000014.00 or equivalent as approved by GE)
AIR FILTER INNER ELEMENT Cat Pt 106900000014.00 or equivalent as approved by GE
All as per item No 1.01 above but DG set capcity 400 KVA,8 K 15 TA ENGINE installed at LONG TERM complete all as specified and directed.
DIESEL FILTER (Cat Pt 65.12503.50011 or equivalent as approved by GE)
OIL FILTER (Cat Pt 65.05510.50208 or equivalent as approved by GE)
AIR FILTER
All as per item No 1.01 above but DG set capcity 400 KVA, 8 K 15 TA ENGINE installed at SBM 13/15 complete all as specified and directed.
DIESEL FILTER (Cat Pt 65.12503.50011 or equivalent as approved by GE)
OIL FILTER (Cat Pt 65.05510.50208 or equivalent as approved by GE)
AIR FILTER
S&F in replacement of battery 180 Ah 12 volt ,maintainenace free heavy duty with battery terminals and copper lead for +ve and -ve ends complete all as specified and directed.
Supply & Filling of heavy duty diesel engine oil of 20W40 grade for DG Sets having capacities varying from 15 KVA to 625 KVA in replacement complete all as specified and directed.
Supply and mixing water coolant in radiator water of DG Sets having capacities varying from 15 KVA to 625 KVA complete all as specified and directed.
Supply and filling distiled water inside the battery and charge properly to maintain battery voltage for 15 KVA to 625 DG Sets complete all as specified and directed.
All as per item No 1.01 above but Dg set capcity 200 KVA, 6 SL 1500 TA ENGINE installed at URAN MISSILE complete all as specified and directed.
DIESEL FILTER (Cat Pt 06.436.01.0.00 or equivalent as approved by GE)
OIL FILTER (Cat Pt F6.0729.010.00 or equivalent as approved by GE)
All as per item No 1.01 above but Dg set capcity160 KVA, TBD 4 L 4 13090 480 3153 GREEVES ENGINE installed at Map Officers
Lub oil filter (Cat Pt 605411880008 or equivalent as approved by GE)
FUEL PRE FILTER (Cat Pt 1200240911 or equivalent as approved by GE)
FUEL MICRO FILTER (Cat Pt 1200240912 or equivalent as approved by GE)
AIR FILTER PRIME (Cat Pt 106900000014.00 or equivalent as approved by GE)
AIR FILTER SECON (Cat Pt 106900000014.00 or equivalent as approved by GE)
All as per item No 1.01 above but Dg set capcity 180 KVA, CUMMINS 6 CTA B 3 G2 -1 ENGINE COUPLED installed at FODC complete all as specified and directed.
DIESEL FILTER ( FS 19634 ) [Cat Pt 4962810 or equivalent as approved by GE]
OIL FILTER ( LF 9009 ) [Cat Pt 3401544 or equivalent as approved by GE]
WATER FILTER ( WF 2152 ) Cat Pt 3800394 or equivalent as approved by GE
All as per item No 1.01 above but Dg set capcity 30 KVA Kirloskar installed at Volna tower complete all as specified and directed.
DIESEL FILTER
OIL FILTER
AIR FILTER
All as per item No 1.01 above but Dg set capcity 160 KVA,TBD 4 L 4 13090 480 3153 GREEVES ENGINE installed at Map Sailors complete all as specified and directed.
Lub oil filter (Cat Pt 605411880008 or equivalent as approved by GE)
FUEL PRE FILTER (Cat Pt 1200240911 or equivalent as approved by GE)
FUEL MICRO FILTER (Cat Pt 1200240912 or equivalent as approved by GE)
AIR FILTER PRIME (Cat Pt 106900000014.00 or equivalent as approved by GE)
AIR FILTER SECON (Cat Pt 106900000014.00 or equivalent as approved by GE)
S&F in replacement of battary 150 Ah 12 volt ,maintainenace free heavy duty with battery terminals and copper lead for +ve and -ve ends complete fixing and testing.
M&L for dismantling of complete radiator assy form engine and taking out all, dissclaing, rusty,sludg and mudy particals inside the radiator by using of sodium hydroxide with water pressure cleaning complete and refixing the radiator assy on its exsisting position and testing complete for its satisfactory perfomance complete all as specified and directed.
For DG Set capacity 15 KVA to 110 KVA
For DG Set capacity 125 KVA to 250 KVA
For DG Set capacity 380 KVA to 750 KVA
Taking out old burnt out Automatic voltage regulator from DG set alternator and S&F suitable capacity of automatic voltage regulator complete testing and checking voltage regulation of the DG set after full load position of DG set for its satisfactory performance complete all as specified and directed.
For DG Set capacity 15 KVA to 110 KVA
For DG Set capacity 125 KVA to 250 KVA
For DG Set capacity 380 KVA to 625 KVA
M&L taking out alternator from exsisting position after disconecting all electrical connection and de-coupling from engine assy and transprting to repair workshop, dismantling the alternator taking out stator/rotor/excitor coil, re-vernishing and rewinding the complete coil heating up for dehydration of moisture cleaning servicing gressing of complete alternator including replacement of bearing re-assembling the alternator complete and transporting to site , refixing the alterator on its exsisting position including coupling with engine assy connection of cable complete all as specified and testing for its satisfactory performance complete all as specified and directed.
For DG Set capacity 50 KVA to 110 KVA
For DG Set capacity 125 KVA to 250 KVA
For DG Set capacity 380 KVA to 625 KVA
M&L for Dismantling the self startor assy from engine and repair servicing of startor by replacing old work out bearing bushing armature coil soloniod switch etc. re-assembling the complete startor fixing the same on engine and testing for its satisfactory performance complete all as specified and directed.
For DG Set capacity 50 KVA to 110 KVA
For DG Set capacity 125 KVA to 250 KVA
For DG Set capacity 380 KVA to 625 KVA
M&L for dismantling of complete radiator assy form engine and , transporting to the workshop and replacement of leakage broken and rusty radiator core for the radiator assy reassemble complete, radiator assy with complete testing and transporting to the site and refixing at the same place from the DG set with complete testing for its satisfactory perfomance complete all as specified and directed.
For DG Set capacity 50 KVA to 110 KVA
For DG Set capacity 125 KVA to 250 KVA
For DG Set capacity 380 KVA to 625 KVA
M&L for disconnection of Diesel Oil tank with inlet and outlet disel pipe line hose/pipe and cleaning of complete oil tank and drain out slug, muddy oil partical complete and refixing after at the same place and connecting complete with existing system including marking of tank showing the capacity in Ltrs and repalacement of transparent PVC pipe complete all as specified and directed.
For DG Set capacity 50 KVA to 110 KVA
For DG Set capacity 125 KVA to 250 KVA
For DG Set capacity 380 KVA to 625 KVA
S&F in re[lacement 12 Volt 10 Amps Auto charge Battery charger with fitment complet with necessary cable connection as frequired for fixing complete all as specified and directed.
S&F in repacement 24 Volt 10 Amps Auto charge Battery charger heavy duty with fitment complet with necessary cable connection as frequired for fixing complete all as specified and directed.
S&F in replacement battery charger heavy duty with charging mode 12 volt to 24 volt, complete with necessary cable connection complete all as specified and directed.
S&F in replacement battery 88 Ah 12 volt dry type ,maintainenace free heavy duty with battery terminals and copper lead for +ve and -ve ends with complete fixing and testing complete all as specified and directed.
S&F in replacement battery 100 Ah 12 volt dry type ,maintainenace free heavy duty with battery terminals and copper lead for +ve and -ve ends with complete fixing and testing complete all as specified and directed.
S&F in replacement copper battery leads of 70 sqmm with brazing work, copper lugs connected to the both ends for +ve and -ve. Length of the leads must be in between 1 to 1.5 Mtrs complete all as specified and directed.
S&F in replacement copper battery leads of 70 sqmm with brazing work, copper lugs connected to the both ends for paring two batteries. Length of the leads must be 0.5 Mtr complete all as specified and directed.
S&F in replacement battery terminals for both the poles i.e pole and neutral complete all as specified and directed.
S&F in replacement engine Harness Includes all the engine wiring, sensor wiring with power con panel assembly for 15 KVA to 62.5 KVA DG Set complete all as specified and directed.
S&F in replacement engine Harness Includes all the engine wiring, sensor wiring with power con panel assembly for 75 KVA to 125 KVA DG Set complete all as specified and directed.
S&F in replacement engine Harness Includes all the engine wiring, sensor wiring with power con panel assembly for 160 KVA to 200 KVA DG Set complete all as specified and directed.
S&F in replacement engine Harness Includes all the engine wiring, sensor wiring with power con panel assembly for 250 KVA to 400 KVA DG Set complete all as specified and directed.
S&F in replacement engine Harness Includes all the engine wiring, sensor wiring with power con panel assembly for 500 KVA to 625 KVA DG Set complete all as specified and directed.
S&F in replacement engine Harness Includes all the engine wiring, sensor wiring with power con panel assembly for 750 KVA DG Set complete all as specified and directed.
S&F in replacement governor controller/ speed controller for the DG set cap 200/250/320 KVA DG set complete all as specified and directed.
S&F in replacement governor controller/ speed controller for the DG set cap 380/400 KVA DG set complete all as specified and directed.
S&F in replacement governor controller/ speed controller for the DG set cap 500/625/750 KVA DG set complete all as specified and directed.
S&F in replacement power contractor 3 pole ,with 2 No + 2NC aux contacts with standard coil voltage 240 volts, rating 32 amp including testing, commisioning as in repairs complete all as specified and directed.
S&F in repacement power contractor 3 pole ,with 2 No + 2NC aux contacts with standard coil voltage 240 volts, rating 40 amp including testing, commisioning as in repairs complete all as specified and directed.
S&Fin replacement power contractor 3 pole ,with 2 No + 2NC aux contacts with standard coil voltage 240 volts, rating 70 amp o including testing, commisioning complete all as specified and directed.
M&L for cleaning of carbon and replacement of old unserviceable asbestos rope suitable size as per KVA rating of DG set on silencer body of the DG set with applying of POP layer complete complete all as per directed
For DG Set capacity 75 KVA to 110 KVA
For DG Set capacity 125 KVA to 250 KVA
For DG Set capacity 380 KVA to 625 KVA
M&L for attending to check the serviceability of DG set of various capacity installed at different locations and specify faults if any within 24 hrs of information as instructed complete all as specified and directed.
M.K Enterprises
M/s S.D Construction Co
M/s Vishwakarma Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .