| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.7 LAccepted-Finance NEAR PUMP HOUSE ROAD NEAR RED ROSE SCHOOL BABINA CANTT JHANSI DISTT UP 284401 | JHANSI | UTTAR PRADESH | 284001 | L1 | Accepted-Finance Being L1 | |
| 2 | L2₹41.2 L+₹9.5 L (29.9%)Rejected-Finance 34 35 ASHOKA ESTATE NEAR S S PUBLIC SCHOOL SEWLA SARAI AGRA 282001 | AGRA | UTTAR PRADESH | 282001 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹47.2 L+₹15.4 L (48.7%)Rejected-Finance C 40 BHAGAT SINGH NAGAR BHIND ROAD GWALIOR MP 474005 | NA | NA | 474005 | L3 | Rejected-Finance Other than L1 | |
| 4 | Rejected-Technical HOUSE NO 164 SHASTRI NAGAR NEAR JAL NIGAM BABINA CANTT DISTT JHANSI UP | BABINA CANTT | JHANSI | UTTAR PRADESH | - | Rejected-Technical Not enlisted in Requisite category i.e. c (i) | |
| 5 | Rejected-Technical 0 SANRPUR MISHRAULIYA PUCHPEDIYA ROAD SANTPUR MISHRAULIYA BASTI UTTAR PRADESH 272001 INDIA | BASTI | UTTAR PRADESH | 272001 | - | Rejected-Technical Not enlisted in Requisite category i.e. c (i) |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
8 Apr 2025, 6:00 pmClosed
GE Babina
GE Babina Cantt PIN- 284401
REPAIR/MAINT OF COOLING APPLIANCES, DEEP FREEZER, WATER COOLER, AIR CONDITIONER, DESERT COOLER AND REPAIR/ REPLACEMENT WORK TO CENTRAL AIR CONDITIONING INSTALLATION UNDER GE BABINA
2025_MES_700922_1
8366/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
GE Babina
As per tender documents
8 documents required · 8 mandatory
₹500
GE Babina
₹94,000
Yes
2 May 2025
10 Mar 2025
10 Apr 2025
10 Mar 2025
8 Apr 2025
25 Mar 2025
Amount
Taking down & M&L for complete Servicing of Split/window AC 2 Ton capacity ,any make any model at various locations comprising of all the installed machineries and accessories such as Rotary/Reciprocating type compressor, condenser,air filter,liquid line filter ,capallary tube,expension valve and other electrical components complete including checking of any leakage in system and repairing, greasing/ lubricating of moving parts, fan motors complete all as specified and directed . Note (i) All servicing and repairs works shall be carried out by authorised service centre/at workshop of manufacturer. (ii) The replacement of defective/ nonfuctional parts such as PVC air filter, relay, capacitor, thermostat, contactor, gas drier filter and other connected items etc, shall be measured and paid separately under relevant item of BOQ . (iv) Quoted rate shall include transportation charges .Note (v) Checking of gas leakage in complete system.Gas and gas charging shall be measured and paid separately. (vi) Cleaning of the indoor & out door unit by cleaning of dust from condenser,air filter, cooling coils, by water pressure pump .
Taking down & M&L for complete Servicing of split /Window type AC 1.5 Ton capacity ,any make any model at various locations comprising of all the installed machineries and accessories such as Rotary/Reciprocating type compressor, condenser,air filter,liquid line filter ,capallary tube,expension valve and other electrical components complete including checking of any leakage in system and repairing, greasing/ lubricating of moving parts, fan motors complete all as specified and directed . Note (i) All servicing and repairs works shall be carried out by authorised service centre/at workshop of manufacturer. (ii) The replacement of defective/ nonfuctional parts such as PVC air filter, relay, capacitor, thermostat, contactor, gas drier filter and other connected items etc, shall be measured and paid separately under relevant item of BOQ . (iv) Quoted rate shall include transportation charges .Note (v) Checking of gas leakage in complete system.Gas and gas charging shall be measured and paid separately. (vi) Cleaning of the indoor & out door unit by cleaning of dust from condenser,air filter, cooling coils, by water pressure pump .
S & F in replacement hermetical sealed gas compressor,ISI Marked suitable for 2.0 Ton MODAL No PH310/410 M2C-4FT6 / SH410/310UV / CR30 for Window Air Conditioner complete all as per directed by Engr-in-Charge. Make Copland/GMCC/Highly
S & F in replacement hermetical sealed gas compressor,ISI Markedsuitable for 2.0 Ton MODAL No PH310/410 M2C-4FT6 / SH410/310UV / CR 30 for Split type Air Conditioner complete all as per directed by Engr-in-Charge. Make Copeland/GMCC/Highly
S & F in replacement hermetical sealed gas compressor,ISI Marked suitable for 1.5 Ton capacity Split type Air Conditioner of MODAL No PH290M2C-4FT6 / SH410UV / SHY33MC2-U as reqd for site suitable for working on 230 V , 50 Hz as per existing make and model including necessary welding/bracing work to existing refrigerant pipes complete all as specified & directed by Engr-in-Charge.Make Copeland/GMCC/Highly
S & F in replacement hermetical sealed gas compressor,ISI Marked suitable for 1.5 Ton Window type AC MODAL No PH290M2C-4FT6 / SH410UV / SHY33MC2-U for Window type Air Conditioner.Make Copeland/GMCC/Highly
S & F in replacement single phase Contactor up to 30 Amp capacity 230 V,50Hz suitable for split type AC complete all as specified and directed. Make- L&T/Havells / BCH / Siemens / ABB
S & F in replacement of gas drier filter two way/One way for window type AC of any make & capacity complete all as specified and directed.
S & F in replacement PVC air filter suitable for window/split type AC of any make & capacity complete all as specified and directed.
S & F in replacement of running capacitor of 36/45 MFD capacity ,230V 50Hz suitable for 1.5 Ton AC complete all as specified and directed. Make –Epcos/Annpurna/Godrej/Hills
S & F in replacement of running capacitor of as 50/60 MFD , 230 V,50Hz capacity complete all as specified and directed. Make Epcos/Annpurna/Godrej
S & F in replacement of starting capacitor of 80/100 MFD ,230 V, 50Hz complete all as specified and directed. Make –Epcos/Annpurna/Godrej/Hills
S & F in replacement of starting capacitor of 100/120 MFD , 230 V, 50Hz capacity complete all as specified and directed. Make Epcos/Annpurna/Godrej/Hills
Dismantling blower/Condenser fan motor of window type AC of 1.5/2.0 TR capacity and Supply and fixing new fan motor alongwith fan of existing make and size and refixing in position, connecting and testing on load all as specified and directed . Make : Crompton/Voltas//GE/Carrier/Samsung/Hitachi/LG
All as per Item No 14 but for split air conditioner of 1.5 /2.0TR capacity.
S & F in replacement of electronic circuit (PCB) Original / Assembled (External type) complete including controlling unit i.e. (remote) all as per existing system and suitable for 1.5/2.0 TR capacity split type / window AC compatible with all AC's Brands in original position as per specified and directed. (As per sample)
S & F in replacement of thermostat suitable for 1.5 TR/2.0 TR capacity Window AC/split AC complete all as specified and directed. Make :- Godrej or equivalent as approved by Engr-in-Charge.
S&F in replacement of internal wiring Kit suitable for 1.5/2.0TR window air conditioner complete all as specified and directed.
S&F in replacement of internal wiring Kit suitable for 1.5/2.0 TR split type air conditioner complete all as specified and directed.
S & F in replacement copper pipe 3/8" dia, wall thickness 0.035 mm including insulation complete all as specified & as directed. .
S & F in replacement copper pipe 1/4" dia, wall thickness 0.032 mm including insulation complete all as specified & as directed.
S & F in replacement copper pipe 5/8" dia, wall thickness 0.032 mm including insulation complete all as specified & as directed.
S & F in replacement copper pipe ½” dia, wall thickness 0.032 mm including insulation complete all as specified & as directed.
S & F in replacement of blower motor for 1.5/2 ton split type AC indoor unit / Invertor unit as per existing shape and capacity complete all as specified and directed. Make : Crompton/Voltas//GE/Carrier/Samsung/Hitachi/LG
S & F in replacement of rubber bush for blower motor, set of two, suitable for window/split type AC of any make and capacity as per sample complete all as specified and directed.
S & F in replacement of louver blades synchronous motor/swing motor for 1.5/2 ton window/split type AC indoor unit of any make and capacity as per sample complete all as specified and directed.
S & F in replacement of electronic display assembly suitable for window/split type air conditioner of any make and capacity as per the sample complete all as specified and directed.
S & F in replacement of drain pipe up to 20 mm dia and up to 3 mtr length including draining pan/drip port suitable for split type air conditioner indoor unit of any make and capacity complete all as specified and directed.
S & F in replacement of blower fan blade suitable for window/split type AC of any make and capacity as per sample complete all as specified and directed.
S & F in replacement of front grill suitable for window type air conditioners 1.5/2.0TR as per sample complete all as specified and directed. (As per sample)
S & F in replacement of temperature sensor assembly for window/split type air conditioner 1.5/2.0 TR as per sample complete all as specified and directed.
S&F in replacement of thermostat switch for 1.5 / 2 ton window/split type AC as per sample complete all as specified and directed.
S & F in replacement of PVC insulated and sheathed multistranded copper conductor cable 3 core of size 4 sqmm dia complete all as specified and directed.
M&L for gas charging with R22/R-32/ refrigerant up to required quantity to window / split type AC 1.5 / 2 Ton capacity on any make / model including flushing of gas,oil charging, necessary welding and bracing works, checking of leakage and testing on full load complete all as specified and directed Note:- No extra payment will be given to contractor to top up the gas in case of leakage from air conditioner.
All as per item No 34 but Refrigerant gas R 410
S & F in replacement of 2 way/3 way valve set of two suitable for split type AC out door unit of any make/capacity complete all as specified and directed.
S& F in replacement of sheet metal enclosure with two pin socket, chain plug cover with one MCB SP 20 to 32 Amp capacity ‘C’ series complete all as specified and as directed.
Supply and fix in replacement, 1100 Volts grade heavy duty cable PVC insulated standard aluminium conductor served with inner sheathing of PVC tape & overall PVC sheathed in service connection, one twin core cable flat or circular of size 10 Sq mm to be connected to existing MCB box / Main switches complete all as specified as dircted.
Supply and fix in replacement, 1100 Volts grade heavy duty cable PVC insulated standard aluminium conductor served with inner sheathing of PVC tape & overall PVC sheathed in service connection, one twin core cable flat or circular of size 6 Sq mm to be connected to existing MCB box / Main switches complete all as specified as dircted.
S & F in replacement of outdoor Condensor coil unit complete suitable for 1.5/2 Ton window type AC including welding/bracing work etc of existing model & make complete all as specified and as directed.
S & F in replacement of outdoor Condensor coil unit complete suitable for 1.5/2 Ton split type AC including welding/bracing work etc of existing model & make complete all as specified and as directed.
S&F in replacement of Indoor Cooling coil unit suitable for 1.5/2.0 Ton window type AC including welding/bracing work etc of existing model & make complete all as specified and directed.
S&F in replacement of Indoor Cooling coil unit suitable for 1.5/2.0 Ton split type AC including welding/bracing work etc of existing model & make complete all as specified and directed.
M&L for taking out existing split AC of 1.5/2.0 TR capacity and reinstalled from one location to other using proper handling including making hole of existing wall for drawing copper pipe/cable to connect in-door unit and out door unit including all electric connection,testing complete all as specified and directed.
M&L for taking out existing window AC of 1.5/2.0TR from one location to another using proper handling and making necessary arrangement in existing window sitable for 1.5/2.0 TR window type AC including all electric connection,testing complete all as specified and directed.
M& L for spray painting with one coat of synthetic enamel paint of cream tint on internal & external steel surfaces of window / split type A/Cs complete including preparing the existing painted surfaces and writing SM No, MES No etc complete all as specified and directed.
M&L for Cutting & removing deteriorated sheet steel surfaces of body, chasis, body bottom portions etc, of window type air conditioners any make and capacity and reconstructing body to the exisitng shape and size with PGI sheet of 16 / 20 SWG, necessary welding / bracing work, including all necessary items such as nuts, bolts, washers, drilling holes etc. including applying two coats of synthetic enamel paint using spray gun over a coat of red oxide primer matching with the existing tint & shade complete all as specified and directed.
S & F in replacement reversible cycle heating unit suitable for split /window type AC 1.5/2 ton capacity including necessary welding /brazing work complete all as specified and directed.
S & F in replacement of three way switch for reversible cycle heating unit to change AC in (1) heating (2) off (3) cooling mode including making connections with suitable size wire and thimbles etc complete all as specified and directed.
Dismantling the old U/S out door unit of split type AC of cap 1.5 Ton and fixing of the New Out Door unit complete with condensor coil, cooling coil made of copper coil , blower motor with PVC fan blade ,Wiring Kit,two pole contactor,running and starting capaciter of 40 to 45 MFD capacity including provision of fixing existing compressor & charging refrigerant gas R22/R32/R410A of required quantity including testing on full load all as specified & directed.
Dismantling the old U/S out door unit of split type AC of cap 2 Ton and fixing of the New out door unit complete with condensor coil, cooling coil made of copper coil , blower motor with PVC fan blade ,Wiring Kit,two pole contactor,running and starting capaciter of 50 to 60 MFD capacity including provision of fixing existing compressor & charging refrigerant gas R22/R32/R410A of required quantity including testing on full load all as specified & directed. Note: Charging of refrigerant gas of required quantity to be measured and paid separately
Dismantling the old U/S Indoor unit of split type AC of cap 1.5 Ton and fixing of the New Indoor unit complete with cooling coil made of copper, blower motor,swing motor,electonic PCB,Display unit,temprature sensor,box type relay complete with PVC drum & electronic circuits including testing all as specified & directed.
Dismantling the old U/S Indoor unit of split type AC of cap 2 Ton and fixing of the New Indoor unit complete with cooling coil made of copper, blower motor,swing motor,electonic PCB,Display unit,temprature sensor,box type relay complete with PVC drum & electronic circuits including testing all as specified & directed.
Dismantling the old U/S of window type AC of cap 2 Ton and fixing of the New unit complete with condensor coil and cooling coil made of copper of suitable size, blower motor with PVC fan blade & PVC drum,,electronic PCB,temprature sensor provision for fixing existing compressor & charging refrigerant gas R22/R32/R410A of required quantity including testing on full load all as specified & directed. Note: Charging of refrigerant gas of required quantity to be measured and paid separately
Dismantling the old U/S of window type AC of cap 1.5 Ton and fixing of the New unit complete with condensor coil and cooling coil made of copper of suitable size, blower motor with PVC fan blade & PVC drum,,electronic PCB,temprature sensor provision for fixing existing compressor & charging refrigerant gas R22/R32/R410A of required quantity including testing on full load all as specified & directed. Note: Charging of refrigerant gas of required quantity to be measured and paid separately
M & L for Taking out of existing blower / condenser motor from split /window type AC of 1.5/2.0 TR capacity and Rewinding the same with supper ennamelled copper wire as existing gauge and varnishing complete with 'E' class varnishing including replacement of necessary parts regrding motor and reassembling and refixing in same position complete all as specified .
M&L for Stripping up deep freezer of any make & capacity 200 to 320 ltr dismantling and taking out unserviceable parts such as relay,over load, thermostat, gas drier filter, bulb etc including fixing new parts with new nut bolts and washers etc re-assembling the deep freezer after repair and testing complete all as specified and directed. Note:- Spare parts shall be measured and paid separately under respective items
S&F in replacement blower fan 5"x5" size 220 VAC 50/60 Hz 0.1 Amp suitable for deep freezer of any make and capacity complete all as specified and directed.
S&F in replacement blower motor with fan blade including nuts, bolts and clamps etc for deep freezer of any make and capacity complete all as specified and directed.
S&F in replacement over load protector for deep freezer of any make/capacity complete all as specified and directed. Make- Technomech/Classic/Annapurna/Lion/coopland.
S&F in replacement starting relay assembly suitable for Deep freezer of any make/capacity complete all as specified and directed. Make- Technomech/Classic/Annapurna/Lion/copeland.
S&F in replacement liquid line filter suitable for deep freezer of any make & capacity complete all as secified and directed.
S&F in replacement thermostat switch for deep freezer of any make and capacity complete all as specified and directed. Make : Renutol / Danfoss
S&F in replacement electronic timer circuit for deep freezer 200-300 ltrs capacity of any make as specified and directed.
M&L for gas charging with R134a refrigerant up to required quantity to deep freezer of any make and capacity including flushing of gas,oil charging, necessary welding and bracing works, checking for leakage and testing on full load complete all as specified and as directed. Note:- No extra payment will be given to contractor to top up the gas in case of leakage from deep freezer.
S&F in replacement condenser coil complete with copper tube and aluminium fins suitable for deep freezer 200-320 ltrs capacity of any make and necessary welding/bracing work complete all as specified and directed.
S&F in replacement sealed compressor MODAL No MA72LCEG/MA88LCEJ/131 suitable for 200-250 ltr capacity deep freezer of any make and model as per sample including necessary welding / bracing work to existing refrigerant pipes complete all as specified & directed.Make LG/Emerson/Copeland/Voltas/Godrej/LG
S&F in replacement sealed compressor MODAL No KCN444/KCN 372LAG/131 suitable for 300 to 400 ltr capacity deep freezer of any make and model as per sample including necessary welding / bracing work to existing refrigerant pipes complete all as specified & directed. Make Emerson/Copeland/LG/Voltas/Godrej
M&L for stripping up refrigerator of any make & capacity 165 to 320 ltr dismantling and taking out unserviceable parts such as starting relay,OLP, thermostat, gas drier filter, bulb etc including fixing new parts with new nut bolts and washers etc re-assembling the refrigerator after repair and testing complete all as specified and directed. Note:- Spare parts shall be measured and paid separately under respective items.
S&F in replacement copper capillary tube size 36 gauge for any capacity refrigerator as specified & directed.
S&F in replacement copper pipe size 1/4" dia for any capacity refrigerator and water coolers & AC as specified & directed.
S&F in replacement PVC stand suitable for any capacity refrigerator as specified & directed..
S&F in replacement evaporator fan motor for double door/single door refrigerator of any make & capacity as specified and directed.
S&F in replacement bimetal thermostate for double door/single door refrigerator of any make & capacity as specified and directed.
S&F in replacement temperature sensor assembly for double door/single door refrigerator of any make & capacity as specified and directed.
S&F in replacement manual timer for double door/single door refrigerator of any make & capacity as specified and directed.
S&F in replacement electronic power supply control PCB for double door/single door refrigerator of any make & capacity as specified and directed.
S&F in replacement electronic timer circuit for double door/single door refrigerator of any make & capacity as specified and directed.
S&F in replacement freezer evaporator assembly for double door/single door refrigerator of any make & capacity as specified and directed.
S&F in replacement PVC freezer door assembly complete with door spring for refrigerator of any make / capacity complete all as specified and as directed.
S&F in replacement ice chamber (Freezer) assembly complete suitable for 165 to 320 ltrs refrigerator of any make / capacity surrounded by freezer pipes complete all as specified and directed.
Supply & fixing condenser coil suitable for 165 to 320 ltrs refrigerator of any make and capacity including welding /bracing work complete as specified and directed.
M&L for gas charging with R-134 A/R-600/R-280 refrigerant up to required quantity to refrigerator of any make and capacity range 165 to 320 Ltr including flushing of gas,oil charging, necessary welding and bracing works, checking for leakage and testing on full load complete all as specified and as directed. Note:- No extra payment will be given to contractor to top up the gas in case of leakage from refrigerator.
M & L for applying a coat of superior quality duco paint of approved tint and shade on the external painted surfaces of refrigerators of any capacity using a spray jet gun including necessary preparation of old painted surfaces including writing of MES No and SM No complete all as specified and directed.
S&F in replacement sealed compressor suitable for 165-220 Ltr capacity MODAL No MSA43LBEG/ MA57LBEG / MA53LAEG for refrigerator of any make and model as per sample suitable for working on 230 V 50Hz including necessary welding/bracing work complete all as specified & directed. Make LG/Godrej/Voltas
S&F in replacement sealed compressor suitable for 280-350 ltr capacity MODAL No MA57LBEG / MA62LCEG for refrigerator of any make and model as per sample suitable for working on 230 V 50Hz including necessary welding/bracing work complete all as specified & directed.. Make LG/Godrej/Voltas
M&L for Stripping up water cooler (storage type) of any make & capacity 40/80, 60/120 & 150 ltr dismantling and taking out unserviceable parts such as starting relay, OLP, thermostat, capacitors, gas drier filter, push cock, floot valve, fan blade etc including fixing new parts with new nut bolts and washers etc re-assembling the water cooler after repairs and testing complete all as specified and as directed.
Taking out and opening carefully blower motor, fan blade of water cooler 40/80 ltrs & 60/120 ltrs & 150 Ltr dismantling, cutting and removing the unserviceable copper winding wire of blower motor and rewinding with super enamelled copper winding wire of existing gauge including replacement of unserviceable bushes/bearings, long nuts, bolts etc and reasembling complete all as specified and directed.
S&F in replacement thermostat switch for water cooler of any make and capacity complete all as specified and directed.Make : Renutol / Danfoss / Whirlpool
S&F in replacement Starting capacitor 40/60 MFD 250 VAC complete all as specified and directed. Make : Havells/Amcap/Epcos/Hills
S&F in replacement Starting capacitor 60/80 MFD 250 VAC complete all as specified and directed.Make : Havells/Amcap/Epcos
S&F in replacement Box type starting relay 20 Amp suitable for water cooler of any make/capacity complete all as specified and directed. Make- Technomech/Classic/Annapurna/Top
S&F in replacement starting relay 8 Amp to15 Amp assembly suitable for water cooler of any make/capacit complete all as specified and directed. Make- Technomech/Classic/Annapurna/Lion/Copeland
S&F in replacement over load protector for water cooler of any make/capacity complete all as specified and directed. Make- Technomech/Classic/Annapurna.
S&F in replacement gas drier filter two way/One way for water cooler of any make & capacity complete all as specified and directed.
S&F in replacement liquid line filter for water cooler of any make & capacity complete all as specified and directed.
S&F in replacement copper capillary tube size 50 No. for water coolers complete all as specified and directed.
S&F in replacement CP push cock / lifting cock (water taps) suitable for 15 mm dia pipe complete all as specified and directed.Make Pryag or any ISI marked.
S&F in replacement PTMT push cock made of stainless steel having 15 mm dia complete all as specified and directed.Make : Prayag / Polytuf
S&F in replacement blower motor 1/10 HP with fan blade including nuts , bolts and clamps etc for any make and capacity of water cooler complete all as specified and directed.Make Godrej/Hills/LG
S&F in replacement blower motor 1/35 HP with fan blade including nuts , bolts and clamps etc for any make and capacity of water cooler complete all as specified and directed.Make Godrej/Hills/LG
S&F in replacement PVC fan blade for blower motor of any size for water cooler complete all as specified and directed.
S&F in replacement PVC float valve assembly complete for 15 mm dia suitable for water cooler complete all as specified and directed. Make : Prayag / Polytuf
S&F in replacement CP nipple 15 mm x 125 mm for water out let pipe all as specified and directed.
S&F in replacement PVC connection 15 mm x 450 mm long for water cooler complete all as specified and directed. Make : Prayag / Polytuf
S&F in replacement PVC flexible pipe 32 mm dia for water cooler drain out pipe complete all as specified and directed
S&F in replacement of PVC insulated and sheathed multistranded copper conductor cable 3 core of size 2.5 sqmm dia for external connection of water cooler, Refrigerator & voltage stablizer Make : Havells/ Plaza/Finolex/National
S&F in replacement condenser coil complete with copper tube and aluminium fins suitable for water cooler 40/80 ltrs, capacity of any make with welding/bracing work complete all as specified and directed.
S&F in replacement condenser coil complete with copper tube and aluminium fins suitable for water cooler 60/120 ltrs capacity of any make with welding/bracing work complete all as specified and directed.
S&F in replacement condenser coil complete with copper tube and aluminium fins suitable for water cooler 150 ltrs capacity of any make with welding/bracing work complete all as specified and directed.
M&L for gas charging with R22/R134A/R290 refrigerant up to required quantity of water cooler any make & capacity including flushing of gas,oil charging, including replacement of necessary capilliary copper tube, necessary welding and bracing works, checking of leakage and testing on full load complete all as specified and directed. Note:- No extra payment will be given to contractor to top up the gas in case of leakage from water cooler.
M & L for applying a coat of superior quality duco paint of approved tint and shade on the external painted surfaces of water cooler any make & capacity using a spray jet gun including necessary preparation of old painted surfaces and applying a coat of black synthetic enamel paint to all internal parts such as compressor unit, condensor fan etc, and writing of MES No and SM No complete all as specified and directed.
S&F in replacement hermetical sealed compressor unit suitable for water cooler 40/80 ltrs capacity Make- Emerson copeland Model No. KCN415 LAG/KCJ444HAG or equivalent approved make, suitable for working on 230 V 50Hz including necessary welding/bracing work complete all as specified & directed.Make Copeland/Emerson/Tecumseh/Voltas
S&F in replacement hermetical sealed compressor unit suitable for water cooler 60/120 ltrs capacity Make- Emerson copeland Model No. HY113 B/S / KCN463HAG or equivalent approved make,suitable for working on 230 V 50Hz including necessary welding/bracing work complete all as specified & directed.Make Copeland/Emerson/Tecumseh/Voltas
S&F in replacement hermetical sealed compressor unit suitable for water cooler 150 ltrs capacity Make- Emerson copeland Model No. KCJ513HAE/KCM511CAL or equivalent make.suitable for working on 230 V 50Hz including necessary welding/bracing work complete all as specified & directed.Make Copeland/Emerson/Tecumseh/Voltas
Supply in replacement of desert cooler heavy duty,electric driven fabricated with 18 gauge GI sheet including vertical support structure of 20X5 angle iron,top and bottom water tank of 18 gauge GI sheet having dimension 85cmX 60cmX 15 cm inside duly painted with double coat rubber paint, and overall size with bottom tank and motor body part not less than 85CM X60CM X110CM when fixed with tank and MS wire net with grass wool pads, with air flow of minimum 5000 CUM/hr complete with submersible type water pump of suitable capacity ,main fan motor (Exhaust fan type) with mild steel fan blade of exhaust fan type motor 450 mm sweep with copper winding,duly protected from front side,swich control panel with separate control for fan and water pump ,230 Volt 50 Hz ,AC single phase including all necessary fitting such as double diversion grill and grill box suitable for 450 mm sweep fan having 1400 rpm including 4 way PVC distributor ,PVC pipe 1 to 2 mtr for spray water,wool pad,electrical wiring for fan & pump ,controlled separately with 15 Amp piano type swich including connection cable of 3 meter length three core sheathed power cable of size 1.5 sqmm and pug top etc complete all as specified and directed.Note:(i) The design of complete desert cooler has to be approved before ordering full qty by accepting officer. (ii) The angle iron and wire net to be pained with synthetic enamel paint over a coat of red oxide primer.The water tank of GI sheet will be painted with double coat of anti rusting rubber paint from inside.
M&L For repairs to water cooler body, base frame with legs, door unit, storage tank, FHP motor base etc of any capcity & make by cutting worn out / deteriotrated portions of sheet steel and reconstructing body including providing ventilation grooves, hinges where required and steel storage tank to the exisitng shape and size using PGI sheet of 16 SWG as per the existing, necessary welding / bracing work to match with the existing surface, including all necessary items such as nuts, bolts, washers, drilling holes etc. and applying two coats of synthetic enamel paint on the affected previously painted area using spray gun over a coat of red oxide primer matching with the existing tint & shade complete all as specified and directed.
Front grill/louvers to desert cooler made out from 0.80 mm thick Galvanised Iron sheet suitable for 5000/4000 Cum/hours capacity desert cooler of any make fixed in repair complete all as specified and directed.
Supply in replacement of desert coolar tank fabricated with 18 gauge GI sheet water tank having dimension 85cm X 60 CM X 15 CM inside duly painted with double coat rubber paint complete all as specified and as directed.
Supply in replacement automatic voltage stabilizer, wall mounted type, single phase, naturally air cooled, indoor type designed for input variation between 170 to 250 Volt and out put voltage stabilised at 230 Volts with accuracy of (+) 2.5% and capacity 4 KVA complete all as specified. Make: V.Guard/Microtech/Blue Bird/Livguard
Supply in replacement automatic voltage stabilizer, wall mounted type, single phase, naturally air cooled, indoor type designed for input variation between 170 to 250 Volt and output voltage stabilised at 230 Volts with accuracy of (+) 2.5% and capacity 5 KVA complete all as specified and directed. Make: V.Guard/Microtech/Blue Bird/Livguard
Supply in replacement fan kit motor suitable for desert coolar RATED OUTPUT 100 W insulation E class single phase small AC induction motror capacitor start run 230 v, 50 hz max current capacity 2025 Mfd complete all as specified and as directed
S&F water lifting pump heavy duty suitable for desert cooler of capacity 4000/5000 cfm, 230 Volts 50 Hz Single Phase, including suitable size PVC three way distributor and PVC pipe of suitable size with elbow and bends including taking down old unserviceable water pump complete all as specified and directed.
S&F wood pad, minimum weight 0.80 Kg, fixed in side panels of desert coolers including taking down old unserviceable complete all as specified and directed.
S&F plug top, three Pin, 5/6 Amps, 230 volts, ISI Marked including taking down old unserviceable complete all as specified and directed.
S&F for sub main wiring(on surface or concealed as site requirement ) with PVC insulated, unsheathed 2 single core cable 1100 volts grade with copper conductor of size 6 sq mm (Nominal area) multi stranded drawn into conduit (Existing / new) with and including 6 sqmm green stranded copper conductor as contineous earthwire with lugs complete all as specified and as directed. Note: New conduit and conduit accossories shall be measured separately.
S & F regid non-metallic PVC conduit not less than 25 mm dia (external) ISI marked (on surface or concealed as site requirement ) incl of all accessories and all fittings such as Tees,bends, elbows, reducers, bell mouth, tube ends and fixing accossories such as couplers,lock nuts, saddles, pipe hook etc complete all as specified and as directed
S&F in replacement of MCB DP 40/63 Amp 240 V ,10KA ,'C' series,complete all as specified and as directed with copper lugs complete all as specified and directed .
S&F in replacement of MCB single pole 6 to 32Amps 240 V,10KA, 'C' series,complete all as specified and as directed with copper lugs complete all as specified and directed .
S&F in replacement of MCCB 100 Amps,4 pole,415volts,3 phase,50HZ, having 16 KA rupturing capacity, 415 volts with electronic trip arrangment and setting screw upto 70- 100% including making connection with excisting cable with connection and materials like copper strips,lugs,nut & bolts etc. complete all as specified and as directed.
S&F TPN DB-DPX 125 MCCB DBs 4 way single door with provision for DPX 125 MCCB and as incomer and SP/TP MCBs as out going no of modules DPX 125+12, concealed Complete all as specified and as directed. Make:- ABB / Havells / HPL / Standard.
S&F sheet metal enclosure double door concealed suitable for distribution boards when MCBs to be used having 100 Amp rated bus bar SPN DB 8 ways 240 V complete all as specified and as directed .
S&F Plastic MCB enclosure suitable for distribution boards when MCBs SPN to be used having 20 to 32 Amp 240 V complete all as specified and as directed .
S&F Metal MCB enclosure suitable for distribution boards when MCBs SPN to be used having 20 to 32 Amp 240 V complete all as specified and as directed .
S&F in repair factory made metal AC stand of required length as per site requirement complete as all specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick weithing not less than 17.5 Kg buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade) and chamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 2009 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs) complete all as specified & testing on completion. NOTE:- (I) item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire. (iii) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe,bends,elbow etc shall be deemed included in the unit rate.
M&L for complete servicing of central AC chiller plant, scroll type capacity 2 X 50 TR central AC plant of Make BLUE STAR Model No:XWC4S-052W (01 x 50 TR running and 01 x 50 TR standby) comprising of all the installed machineries and accessories with scroll compressors (04 x 12.5 TR in each unit), cooling towers , AHUs , water pumps, LT panels ,shell & tube type condensing unit and insulated chiller complete including checking of any leakage in system and repairing, checking of all controls, cleaning of cooling tower unit and greasing/ lubricating of moving parts, fan motors, checking of core filters etc complete all as specified and directed. All servicing and repairs works shall be carried out by authorised service centre /OEM of Blue star company . Note A :- 1. The plant shall be serviced by auth service technician /engineer of Blue star company and will check all parameters /defects and leakage of plant and submit report to Engineer in charge. All necessary repairs/servicing will be done by auth service engineer of Blue star company. 2. All spares /material required for repairs will be paid and measured separatly against relevent items of schedule hereunder.
M&L for complete servicing of 3x5 TR floor-mounted vertical units Central AC Plant( 02 x 5 TR of Blue Star Make and 01 x 5 TR of Voltas Make ) comprising the installed machineries and accessories mainly sealed compressors (01 x 5 TR in each unit), compressors, cooling towers , AHUs , water pumps, LT panels ,shell & tube type condensing unit and insulated chiller complete including checking of any leakage in system and repairing, checking of all controls , cleaning of cooling tower unit and greasing/ lubricating of moving parts, fan motors, checking of core filters etc complete all as specified and directed . All servicing and repairs works shall be carried out by authorised service centre /OEM of Blue star and Voltas company . Note A :- 1. The plant shall be serviced by auth service technician /engineer of Blue star company and will check all parameters /defects and leakage of plant and submit report to Engineer in charge. All necessary repairs/servicing will be done by auth service engineer of Blue star company. 2. All spares /material required for repairs will be paid and measured separatly against relevent items of schedule hereunder.
M&L for descaling and cleaning of condenser of central AC Plants shell/ tube type water cooled DX type or chilled water type of capacity 02 x 50 TR (01 x 50 TR running and 01 x 50 TR standby) by carefully opening of condensers covers, cleaning of copper tubes with descaling chemical suggested by manufacturer of chiller machine or concentrate acid circulated by using of descaling pump, nylon bristles brushes of suitable sizes carefully without damaging tubes, removing scale, foreign matter and cleaning with water complete including replacement of worn out/damaged parts, like gaskets, nuts, bolts, studs etc complete all as specified and directed by Engineer-in-Charge.
All as per item No 140 here-in-before but of capacity 10 TR (03 x 5 TR) (Signal centre). Note:- De scaling work will be carried out through Auth. Rep of menufacturer of chiller unit
M & L for descaling of choked condenser pipe/ water circulating pipes (condenser to cooling tower ) of 50 TR (01 x 50 TR running and 01 x 50 TR standby) capacity AC plant at Auditorium including descaling and cleaning tower with MAIC solution/ descaling chemical or concentrated acid and water in cooling tower for removing complete scale including cooling tower basin etc with help of steel wire brushes and draining out complete solution and filling of fresh water for checking leakage in pipes including replacing flange packing, nuts,bolts etc complete all as spacified and directed by Engineer-in-Charge.(Auditorium)
All as per item No 142 here- in-before but for capacity 10 TR (03 x 5 TR) (Signal centre). Note:- De scaling work will be carried out through Auth. Rep of menufacturer of chiller unit
M&L for repair and servicing of cooling tower of cap 50 TR AC plant of any make and type including dismantling of cooling tower for removing of top cover and fills, replacement of unserviceable nozzle/sprinkle,replacement of rusted nuts, bolts with washers etc and cleaning bottom tank to remove mud and dust complete all as directed by Engineer-in-Charge.
M&L for repair and servicing of cooling tower of cap 05 TR AC plant of any make and type including dismantling of cooling tower for removing of top cover and fills, replacement of unserviceable nozzle/sprinkle,replacement of rusted nuts, bolts with washers etc and cleaning bottom tank to remove mud and dust complete all as directed by Engineer-in-Charge. (Note: the replaced parts shall be measured and paid separately under item Sl no. 140 & 141 as supply only .)
Supply only the following spare parts for item required for item no. 138 & 139
(a) Float valve assembly complete any size
(b) PVC spray assembly / Nozzel
M&L for Inspection,checking of 02 x 50 TR (01 x 50 TR running and 01 x 50 TR standby) capacity AC plant at Auditorium by authorised Representative of Blue Star/ Voltas Company of all connections of control wiring of microprocessor based AC compressors and compressor panel ,testing and calibration of compressor through panel for loading and unloading test on required set temprature(as specified by the user) of the compressor and some other priodical tests required of the plant as per menufaturer guideline for smooth functioning of plant and submit the test report and their recommendation/suggetions for better performance of Plants on their standard formate complete all as specified and directed by Engineer-in-Charge.
M&L for Inspection ,checking of 03 x 5 TR (02 x 05 TR running and 01 x 05 TR standby) capacity AC plant at Signal Centre by authorised Representative of Blue Star/ Voltas Company of all connections of control wiring of microprocessor based AC compressors and compressor panel ,testing and calibration of compressor through panel for loading and unloading test on required set temprature(as specified by the user) of the compressor and some other priodical tests required of the plant as per menufaturer guideline for smooth functioning of plant and submit the test report and their recommendation/suggetions for better performance of Plants on their standard formate complete all as specified and directed by Engineer-in-Charge.
Supply & Fix, PVC sheet cover/shed (for reain protection) of motor along with fixing arrangement i.e nuts, bolts, washers etc complete all as specified and as directed.
Supply & Fix PVC filling blocks of size approx 600mm x 300mm x 150mm suitable for cooling tower of 50 TR AC plant complete all as specified and as directed. Make : MIHR/AVIRAT/SUVIDHA
S&F in repairs PVC honey comb fillings for 5 ton AC plants cooling tower by taking down cooling tower at site & dismanteling carefully and keeping in safe custodyn for reuse complete all as specefied and directed by Engnr-in-charge.
Taking out the burnt electric motor of capacity 1.0 HP to 3 HP from existing position, transporting to civil work shop, separating the stator and rotor housing, cutting and removing the existing winding of stator completely, cleaning the slots and rewinding with existing gauge of super enamelled copper winding wire with suitable insulation, applying insulation varnish and heating in heating chamber till completely dried and reassembling the motor including supply and replacement of DE(01 No.) &NDE(01 No) bearings (make: NBC/SKF/TATA), transporting back to site and re-installing in its original position including proper alignment for smooth running and testing on completion complete all as specified and directed by Engineer-in-Charge.
All as per item no 155 but 5 HP to 7.5 HP motor
All as per item no 155 but 10 HP to 15 HP motor
M&L for taking out the defective pump set of capacity upto 1 to 3 HP of AC plant from existing position by carefully disconnecting all water pipe lines and electrical cables and carrying out overhauling by dismantling the pump casing, cleaning of the impeller and supply and replacement of Gunmetal bush(01 No), gland plate (01 No.) alongwith studs, nuts, gland packing rope, greasing and re-assembling and re-installing in its original position and testing on completion complete all as specified and directed by Engineer-in-Charge. Note:-spare parts other than mentioned above under this item will be measured and paid separately as supply only.
Supply only end ball / roller bearing with good quality grease suitable for pump sets 1 HP to 3 HP complete all as specified and directed.Make:NBC/SKF/Tata
Supply only star coupling key any size as per sample complete all as specified and directed.
Supply only pump shaft suitable for pump sets 1 HP to 3 HP capacity complete all as specified and directed.
Supply only pump impeller brass suitable for pump sets 1 HP to 3 HP capacity complete all as specified and directed.
Supply only gun metal bush bearing complete set of two as per sample for 1 HP to 3 HP pump complete all as specified and directed.
M&L for taking out the defective pump set of capacity upto 5 to 7.5 HP of AC plant from existing position by carefully disconnecting all water pipe lines and electrical cables and carrying out overhauling by dismantling the pump casing, cleaning of the impeller and supply and replacement of Gunmetal bush(01 No), gland plate (01 No.) alongwith studs, nuts, gland packing rope, greasing and re-assembling and re-installing in its original position and testing on completion complete all as specified and directed by Engineer-in-Charge. Note:-spare parts other than mentioned above under this item will be measured and paid separately as supply only.
Supply only end ball / roller bearing with good quality grease suitable for pump sets 5 HP to 7.5 HP complete all as specified and directed. Make:NBC/SKF/Tata
Supply only pump shaft suitable for pump sets 5 HP to 7.5 HP capacity complete all as specified and directed.
Supply only pump impeller brass suitable for pump sets 5 HP to 7.5 HP capacity complete all as specified and directed.
Supply only gun metal bush bearing complete set of two as per sample for 5 HP to 7.5 HP pump capacity complete all as specified and directed.
M&L for taking out the defective pump set of capacity upto 10 to 15 HP of AC plant from existing position by carefully disconnecting all water pipe lines and electrical cables and carrying out overhauling by dismantling the pump casing, cleaning of the impeller and supply and replacement of Gunmetal bush(01 No), gland plate (01 No.) alongwith studs, nuts, gland packing rope, greasing and re-assembling and re-installing in its original position and testing on completion complete all as specified and directed by Engineer-in-Charge. Note:-spare parts other than mentioned above under this item will be measured and paid separately as supply only.
Supply only end ball / roller bearing with good quality grease suitable for pump sets 10 HP to 15 HP complete all as specified and directed. Make:NBC/SKF/Tata
Supply only pump shaft suitable for pump sets 10 HP to 15 HP capacity complete all as specified and directed.
Supply only pump impeller brass suitable for pump sets 10 HP to 15 HP capacity complete all as specified and directed.
Supply only gun metal bush bearing complete set of two as per sample for 10 HP to 15 HP pump capacity complete all as specified and directed.
Supply and fix in repalcement of high grade iron pully having dia up to 60 cm and thickness up to 3 cm with V shape grooves suitable for B-77 belt and shaft hole up to dia 6 cm suitable for AHU blower motor complete by dismantling old pully from blower unit and fixing the same in original position complete all as specified and directed
Supply and fix in replacement of Blower Shaft having approx dia 6 cm suitable for 10/15HP AHU motor by dismantling old unserviceable shaft from AHU unit including transportation ,filling metal to deshaped portion of key groove,grinding ,polishing the key groove ,replacing lock key ,refixing in existing position in AHU unit, testing complete all as specified and directed
Supply and fix in repalcement of 6 mm thick nitrile rubber insulation on condensate drain pipe of size 50/40mm dia and fitting like valve,flanges, and union etc complete all as specified and directed Make: Accoflex,Armacell,K flex
Dismantling and taking down scrolled type sealed compressor 12..5 TR( Make : Denfoss model No:SZ18554RC,) from main unit and complete repair of compressor including changing of compressor oil to existing capacity ,solder sleeve,Rotolock valve,gasket ,angle adapter descaling the entire copper tube by using HCL or any other chemical specified as per manufacturer complete testing and refixing to original position all as specified and directed. Note:- Repairing work will be carried out through Auth. Rep of menufacturer of chiller unit
S&F in replacement of sealed unit scroll compressor of 12.5 TR model No. SZ185S4RC, 380-400 V, 50 Hz including charging of gas complete after taking down defective compressor from enclosure and making connection/jointing suction/discharge pipe for 50 Ton capacity AC Plant{50 TR x 02( 01 unit run , 01 stand by), 01 unit consisting of 04 X 12.5 TR cap . Compressors} complete all as specified and as directed. Make:- Danfoss/Copeland/Emmerson/ Tecumseh or equivelent. Note:- fixing of new compressor work will be carried out through Auth. Rep of menufacturer of chiller unit
S&F in replacement sealed compressor unit suitable for 5 ton type AC plant, Model No. CR72KQM-TFM of Emerson Copeland or equivalent approved make suitable for working on 380-420 V 50 Hz 3 phase including necessary welding/bracing work to existing refrigerant pipes and including R-22 refrigerant gas of required and testing on load complete all as specefied and directed by Engnr-in-charge. Note:- fixing of new compressor work will be carried out through Auth. Rep of menufacturer of chiller unit
S&F in replacement cooling coil unit complete for AC plant 5 ton capacity including making connection with expansion valve & discharge of compressor (for reference only dimensions of cooling coil 70 x 46 x 12 cm approx 09 vertical coils & 03 Horizontal coils, dia of cooling coil 15 mm approx) including top up filling of refg. gas R 22 of required quantity including testing on full load complete all as specefied and directed by Engnr-in-charge. Note : (i) Refg Gas for top up /filling will be measured & paid separatly under relevant items. (ii) Repairing work will be carried out through Auth. Rep of menufacturer of chiller unit
Supply and fix in replacement of filter drier danfoss model No:DCL165 suitable for 5TR AC plant complete all as specified and directed.
Supply and fix in replacement of filter drier danfoss model No:DCL305 suitable for 50 TR AC plant complete all as specified and directed.
Supply and fix in replacement of Bimetal overload relay suitable for 5 TR central AC plant complete all as specified and directed.
Supply and fix solder tube union (with valve core & copper tube) as per existing size complete all as specified and as directed.
Supply and fix in replacement of Bimetal overload relay suitable for 50 TR central AC chiller plant complete all as specified and directed.
Supply and fixing in replacement of expansion valve Denfoss model No:TGEX or equivalent approved by GE for 12.5TR compressor complete removing of old expansion valve from company mechanics and refixing the new expansion valve and connection with own arrengement and making plant running condition complete all as specified and directed.
Supply and fixing in replacement of expansion valve of 5 TR plant complete removing of old expansion valve from company mechanics and refixing the new expansion valve and connection with own arrengement and making plant running condition complete all as specified and directed.
M&L for gas charging to compressor 5 ton capacity with R 22 gas and compressor topl up to specified quantity including flushing out old gas and oil including testing on full load & checking for leakage by filling nitrogen gas up to the pressure of 250 psi in the plant for 24 hours complete all as directed. Note:- (i) No extra payment will be given to contractor to top up the gas in case of leakage from plant. The cylinder for refrigerant provided by the Contractor. Empty cylinder will be returned to the Contractor after consumption of refrigerant. (ii)Repairing work will be carried out through Auth. Rep of menufacturer of chiller unit
M&L for gas charging to compressor 12.5 ton capacity with R 407C gas including flushing out old gas and oil including testing on full load & checking for leakage by filling nitrogen gas up to the pressure of 250 psi in the plant for 24 hours complete all as directed. Note:- (i)No extra payment will be given to contractor to top up the gas in case of leakage from plant. The cylinder for refrigerant provided by the Contractor. Empty cylinder will be returned to the Contractor after consumption of refrigerant.(ii)Repairing work will be carried out through Auth. Rep of menufacturer of chiller unit
S&F in repair complete wiring kit as per existing size for 5 ton capacity AC plant complete all as directed.
S&F in repair complete wiring kit as per existing size for 50 TR capacity AC plant complete all as directed.
S&F in repair high pressure / low pressure control switch complete all as directed Make : Emerson / Denfoss
S&F in repair high pressure / low pressure / Oil pressure sensor complete all as directed.
S&F of aluminium rotery sprinkler 50 mm dia with branch/sprinkler pipe 4 Nos suitable for cooling tower unit complete all as specefied and directed by Engnr-in-charge.
S&F Gun metal gate valves of 25 mm bore (class I) ISI marked with iron wheel head, screwed both ends for iron pipe including dismantling and taking up/ down all as specified and directed at site.
S&F Gun metal gate valves of 40 mm bore (class I) ISI marked with iron wheel head, screwed both ends for iron pipe including dismantling and taking up/ down all as specified and directed at site.
S&F Gun metal gate valves of 50 mm bore (class I) ISI marked with iron wheel head, screwed both ends for iron pipe including dismantling and taking up/ down all as specified and directed at site.
Taking up or down 25 mm dia steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 40 mm dia steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 50 mm dia steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed.
Supplying, fixing, jointing and testing 25 mm dia galvanised steel tubing medium grade with all fittings such as bends, elbow, socket, reducer etc, laid under floor / trenches complete all as specified and directed.
Supplying, fixing, jointing and testing 40 mm dia galvanised steel tubing medium grade with all fittings such as bends, elbow, socket, reducer etc, laid under floor / trenches complete all as specified and directed.
Supplying, fixing, jointing and testing 50 mm dia galvanised steel tubing medium grade with all fittings such as bends, elbow, socket, reducer etc, laid under floor / trenches complete all as specified and directed.
supply and fix in replacement Butterfly valves PN 1.6 flanged type heavy duty of size 100 mm bore including necessary accessories to fix the same in existing hot as well as in chilled water line complete all as specified and directed. Make : Audco/Advance/Castle or any equivalent ISI marked.
supply and fix in replacement Butterfly valves PN 1.6 flanged type heavy duty of size 150 mm bore including necessary accessories to fix the same in existing hot as well as in chilled water line complete all as specified and directed. Make : Audco/Advance/Castle or any equivalent ISI marked.
Supply and fix in repair of 'Y' strainer of size 100 mm bore as per existing sample complete all specified and directed.
Supply & fixing in replacement of PCB card for 50 TR Central AC Plant BLUE STAR Model No:XWC4S-052W as per existing size and capactiy and install all the programe and making plant in running condition complete all as specified and directed.
Supply & fixing in replacement of PCB card for 05 TR Central AC Plant BLUE STAR as per existing sample and capactiy, installed, testing and comissioning by authorised company mechanics/dealer and making plant in running condition complete all as specified and directed.
supply and fix in replacement Sub Zero 7510 T-Temperature Controller as per existing sample complete all as specified and directed.
supply and fix in replacement Power contactor 3 pole 32/30 Amps with no volt coil and all accessories for fixing the same in exisitng starter all as specified and directed. Make : L&T Type MNX 32 or equivalent in schneider / GE / Siemens ./ ABB
supply and fix in replacement Power contactor 3 pole 25 Amps with no volt coil and all accessories for fixing the same in exisitng starter. Make : L&T/Siemen/C&S./ABB
S&F in repair thermal overload relay range28 - 36 Amps complete all as directed Make : Seimens / L&T/ABB
S&F in repair thermal overload relay range17 - 25.5 Amps complete all as directed Make : Seimens / L&T/ABB
S&F single phasing preventor suitable for AC plant complete all as directed Make : Minilec / L&T / Seimens
Supply and fix in replacement MCCB 4 pole 415 volts Ics=100%Icu, 35 KA of capacity 400 Amps with adjustable thermal setting all as specified and directed. Make : L&T/Schneider/GE/Legrand/Havells
Supply and fix in replacement MCCB 4 pole 415 volts Ics=100%Icu, 35 KA of capacity 200 Amps with adjustable thermal setting all as specified and directed. Make : L&T/Schneider/GE/Legrand/Havells
Supply and fix in replacement MCCB 3 pole 415 volts Ics=100%Icu, 25 KA of capacity 160 Amps with adjustable thermal setting all as specified and directed. Make : L&T/Schneider/GE/Legrand/Havells
Supply and fix in replacement MCCB 3 pole 415 volts Ics=100%Icu, 25 KA of capacity 63 Amps with adjustable thermal setting all as specified and directed. Make : L&T/Schneider/GE/Legrand/Havells
Supply and fix in replacement MCB 3 pole 415 volts Ics=100%Icu, of capacity 32 Amps with adjustable thermal setting all as specified and directed. Make : L&T/Schneider/GE/Legrand/Havells
Supply and fix in replacement MCCB 3 pole 415 volts Ics=100%Icu, 25 KA of capacity 100 Amps with adjustable thermal setting all as specified and directed. Make : L&T/Schneider/GE/Legrand/Havells
S & F in replacement off Load Change over switch 4 pole 415 Volt 50 HZ ,side operated 315 Amp in SS enclosure with side handle Make Havells /HPL/INDO ASIAN/L&T/ABB
S & F in replacement off Load Change over switch 4 pole 415 Volt 50 HZ ,side operated 630 Amp in SS enclosure with side handle Make Havells /HPL/INDO ASIAN/L&T/ABB
M&L for Opening of AHU Coil, Supply duct & return duct, diffusers, grills, fire damper and any other installed component that part of Central AC plant at Cav Auditorium and signal center . All above part should be cleaned with following procedures and equipments:- (a) Rotary brushes system self-propelled type with different types of brushes and used to agitated and loosen dirt with duct. (b) Wiper set used again to loosen dirt depending upon the type & size of duct. (c) Contact vacuuming menthod of HVAC system cleaning which incorporates agitation and vcuum collection principle into one operation. (d) Compressed air washing mechanical means to agitate and dislodge particulate form the interior surface of HVAC system. (e) All of the grill and differs are removed and clean (f) Starting for farthest vent opening each branch line is cleaned using nylon duct brushes, cable driven brushes, or forwarded air blast assemblies to loosen debris. The agitation tool causes debris to the quickly caught up in the air movement from the HYPE M/c The process is then repeated at each vent opening . Once all the branch line have been cleaned , the main pocket filter is cleaned. (g) After the dust and debris is removed from the system, an light fogged through the air duct system, This product immediately kills fungus or bacteria. The blower motor is inspected and cleaned if necessay and accessible. (h) The insulation in the air handler unit case is manually cleaned and then treated with fogger m/c to kill an residual mold, fungus, or bacteria. The blower motor is inspected and cleaned if necessary and acessible. (j) Coil cleaning with the COIL CLEANER (k)Testing the duct after cleaing all part of the system of air ducts.
Dismantling and taking down of existing micro filters of size 5 to 10 micron from AHU duct plannum for checking the serviceablility of flter element, servicing and cleaning of filter elements, replacement of existing unserviceable filters and fixing serviceable filters in position complete all as specified and as directed.
supply and fix in replacement Pressure guage 0-10 Kg/cm2, round dial type including brass nipple, test cock and other minor accessories to fix the same in AC plant/AHUs all as specified and directed. Make : H. Guru/ Fiebig/ Dwyer.
supply and fix in replacement Temperature guage 0-50ºC, rectangular type with transparent glass to see the reading including brass nipple and other minor accessories to fix the same in AC plant/AHUs all as specified and directed. Make : Taylor/ H. Guru/ DS Engg or any equivalent ISI marked.
Supply and fixing in replacement VFD of AHU/ AC plant unit for existing motor capacity as er existing samle complete all as specified. Make: Danfoss or as approved by GE
supply and fix fully automatic star-delta starter for central AC plant capacity from exceeding 10 to 15 HP complete all as specified and directed . Make L&T/Havells/C&S
M&L for PVC Insulated, unsheathed multi stranded copper conductor cable, heavy duty, 1100 Volts grade 3 core of RYB colour 16 Sqmm in replacement for connection from LT panel board to motor starters and from starters to electric motors including necessry cable end termination with copper lugs of suitable size all as directed, confirmong to IS:694 drawn through concealled heavy grade PVC conduites of not less than 32 mm nominal dia with necessary fittings such as bends, sockets etc. laid under the floor or fixed to the walls with suitable clamps or saddles including taking down of existing cable all as specified and directed. Make :- KEI Industries/ Polycab/FINOLEX/ Havells
Supply, laying & testing of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with multi stranded aluminum conductor, 1100V grade with stranded aluminium conductor of size 10 sqmm 4 core . Make :- KEI Industries/ Polycab/FINOLEX/ Havells
M&L for replacement of existing street light with new generartion energy saving and enviromental friendly long life LED Street light made up innovative die cast aluminium housing high power LED as light source with IP-66 power consuption 120 Watt having minimum luminous 100 Watt complete input voltage of 150-240V (Nominal rated 240V)including multistranded twisted copper cable of 1.5 Sqmm dia for connecting street light to junction boxes through PVC coated copper connectors and the rate include taking down of existing unserviceable street light from poles etc complete all as specified and directed. Havells/Bajaj/CG/ Halonix/phillips/Belno
S&F in replacement of fins and strip type heating element industrial type suitable for AHU unit of AC plant of capacity 4 to 6 KW or higher capacity available by dismantling old unserviceable heater including refixing at existing place,testing complete all as specified and directed.
M & L for earthing complete with galvanized steel earth plate electrode 60 x 60cm x 6 mm thick burried directly in ground vertically to a depth not less than 3.0 mtr deep below GL with top edge of the plate not less than 3.0 mtr below normal GL and connected to earth plate . Earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt upto 1.5 meter depth all around the earth plate and connected to earth lead of GI strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvd iron or steel and thimbles and other end of the earth wire connected to DB and protected by galvanized iron or steel pipe light grade 15 mm bore and water pipe 20mm bore GI medium grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of 2009 and also including making test point for testing of earthing made out of gun metal or phosphorous bronge size 75x75x25 mm complete . Note : 1. RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmm in lieu of CI cover. 2. Charcoal dust and common salt upto 1.5 meter depth shall be filled in layers of 15 centimeters all around the earth plate inside earth pit . On testing after completion of earthing if desired earth resistance is not achieved , the earthing will be redone at no extra cost to obtain the desired earth values
S&F GI earth strip 32X6 mm fixed to wall, on battens, or recess or chases or buried in found, complete all as specified and as directed by Engineer–in –Charge.
S&F in repair thermostat as per existing size complete all as directed Make : Emerson / Denfoss
Supply and fix in replacement of superior quality V belt(B-77) suitable for blower motors of AHU unit. Make; Fenner/ Dunlop
Supply and filling compressor oil Freezol 68 or equivalent as approved by GE for topping up all as specified Make: HP/Bharat/ Indian Oil
S&F in replacement of mild steel foundation channel support assembly made out of MS channel size 4X10cm having thickness of 4 mm suitable for monoblock pump moter set of capacity 3 HP to 5 HP coupled with suction/delivery pipes of size 150mm/100mm/80mm/50mm/40mm with necessary bolts complete all as specified and directed Note:Provision of connection withn existing suction/delivery pipe including proper alignment necessary bushing,tapers,reducesers,MS flange ,welding work,etc as required at site for commissioning of pump sets in deemed to be included in the quoted rates.
M&L for leakage detection and making AC system leakage free including testing after application of nitrogen gas pressure to find out any leakage and stopping of all leakage detected, re-application of nitrogen pressure(kept for a 24 Hrs) to ensure leak proof gas circulated in system, flushing out the nitrogen gas and vaccume the entire system before charging of refrigerent gas by standing desired pressure complete all as directed by Engr- in-charge. (50 TR AC Plant) Note:- Repairing work will be carried out through Auth. Rep of menufacturer of chiller unit
M&L for leakage detection and making AC system leakage free including testing after application of nitrogen gas pressure to find out any leakage and stopping of all leakage detected, re-application of nitrogen pressure(kept for a 24 Hrs) to ensure leak proof gas circulated in system, flushing out the nitrogen gas and vaccume the entire system before charging of refrigerent gas by standing desired pressure complete all as directed by Engr- in-charge. (05 TR AC Plant) Note:- Repairing work will be carried out through Auth. Rep of menufacturer of chiller unit
Supply and fix of insulation on AC duct with closed cell chemically crossed linked polyethylene foam 19 mm thick duly laminated aluminum foil (class “O”) and fixing with suitable adhesive and joints shall sealed with suitable size self adhesive aluminum/ silver insulation tape complete all as specified and directed.
Supply, fabrication, installation and testing of sheet metal ducts made of 0.80 mm thick plain galvanised iron (PGI) sheet confirming to IS-277 and IS-655 (Galvanising @ 120 per Sqm inclusive of both sides, 'O' grade sheets) with and including necessary GI hangers, supports, volume control duct dampers, other accessories, vanes, 3 mm thick EPDM rubber gasket etc. complete all as specified and directed. NOTE: - Unit quoted rate shall be inclusive of reinforcement, strengthening work for ducts, making air tight joints, accessories such as splitter, damper, guide vanes, hangers, fasteners and supports as required at site.
M&L for preparation of old painted surfaces by removing dust, rust etc and, applying two coats of synthetic enamel paint with spray gun of approved make and colour for cooling tower, condensing pipe line condenser water pumps including all pipe line valves etc. of 5 TR to 50 TR Capacity Plant complete all as specified and as directed.
M&L for repair, servicing of complete AHU including opening and dismentaling making noiseless in all respect duly oiling, greasing or replacement of suitable size of ball bearing and ballancing of AHU motor and connecting accessories with duct etc complete all as specified and directed.
M&L for dismenteling/opening air filter,nut bolts , tray for AHU including cleaning of cooling coil complete with coil cleaner solution and high pressure water of 50 TR capacity AHU including rectified leackage of refrigerant and making complete cooling coil in functioning condition and refixing same air filter,nut bolts , tray complete all as specified and directed.
M&L for dismenteling/opening air filter,nut bolts , tray for AHU including cleaning of cooling coil complete with coil cleaner solution and high pressure water of 05 TR capacity AHU including rectified leackage of refrigerant and making complete cooling coil in functioning condition and refixing same air filter,nut bolts , tray complete all as specified and directed.
Disconnecting and removing existing unserviceable interlocking wiring and connection of electric control panels of any description and in any position after through checking and inspection at site and material & labour for repair of electric control panel and its interconnected system with using PVC insulated ,unsheathed multistranded copper conductor cable,single core 1.5 Sqmm size, 1100 Volts grade for making functional control of the compressor,chilled water pump,condenser water pump, AHU, cooling tower fan, LP/HP/Differential coil, pressure switch, solenoid valve, capacity control valve, thermostat, humidistate, heater, auxilliary contactor,push buttons, indicators, Ammeter,Voltmeter complete as required at site for functioning of Central AC plant,DX type/chilled water type complete all as specified and directed by Engineer-in-Charge. Note:- (i) Work shall be executed at site by proper skilled,experienced workers . (ii) The complete panel shall be checked and tested on full load after necessary repairs and replacement of unserviceable parts for its smooth functioning and proper interlocking including tripping on single phase.
M & L for PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in plinth block for support of pipe including form work weathering slightly chamfered angle and throating with and including necessary form work and finished concrete surface even & smooth without using extra cement complete, all as specified and directed by Engr-in-charge .
M&L for providing and fixing stainless steel (Grade 304) railing/sign board made of hollow tubes/ rectangular/square as per site requirement, channels, plates etc, including welding, grinding, buffing, polishing and making curvature (where ever required and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the ralling with necessary accessories & Stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed.
S&F Retro reflective sign board made up with 1.2mm thick stainless steel sheet of which both faces shall be fully covered with high intensity prismatic(HIP) retro reflactive sheeting of approved specification as MORT having approved massage (Matter and Base) fully processed by pressure sensetive equipment of approved brand (Avery Dennison/3M) fixed on stainless steel frame made up of SS as described in the item above specification complete all as specified and directed.
Supply, installation in repair ABC type fire extinguisher of capacity 9 Ltrs (ISI Marked) with all accessories complete all as specified and directed by Engineer-in-Charge.
Supply and installation in repair set of 3 Bucket made out of MS Sheet of capacity 9 Ltrs with carrying handle at bottom of the bucket each for fire fighting point duly painted with PO Office red enamel complete all as specified and directed.
Construction in repair (including dismantling) of Fire fighting post of Height 3.5 Feet x length 6 feet x width 3 Feets made out of MS Angle and MS Sheet duly painted with PO Red enamel and construction of PCC Foundation for fire fighting to be prepared as per direction of Engineer in Charge
Supply and fixing in replacement brass angular valve as per existing sample of AC plant complete all as specified and directed
S&F in replacement of Microprocessor controller based operating control board as per existing sample or recommended by OEM complete all as specified and directed.
S& F XLPE insulated armoured and pvc sheated heavy duty electric cable with aluminium conductor 1100 volt grade laid in tranches passing through pipes /ducts including testing complete of 3.5 x 400 sqmm LT cable complete all as specified and directed. Note- rate is inclusive of cable gland & cable lugs
S& F XLPE insulated armoured and pvc sheated heavy duty electric cable with aluminium conductor 1100 volt grade laid in tranches passing through pipes /ducts including testing complete of 3.5 x 120 sqmm LT cable complete all as specified and directed. Note- rate is inclusive of cable gland & cable lugs
Supply and fixing of GI cable tray perforated of size 250mm x 50mm and 14 gauge thick including accessories like coupler plate, nut bolts washers, suspension rod for fixing /hanging tray in wall/ceiling, clamps wall brackets up/down, elbows bends tees etc and fixing with FRP saddles in equal distance on wall/floor/through wall crossing and making good the surface and painting matching with existting tray complete all as directed by Engr-in-charge.
Surface excavation n. exc. 30cm deep and averaging 15cm deep and getting out in soft /loose soil including cutting of bushes, sapling sand cutting trees not exc 30m girth etc complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, approved earth including spreading, levelling, watering and well ramming in layers n.exc 25 Cm thick after cable are laid and tested complete all as specified and directed.
Removing excavated material / surplus soil to a distance not exc. 50 mtrs & deposited where directedat a level not exc. 1.5 mtr above the ground level complete all as specified & directed.
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation, filling and mass complete all as specified and directed.
Providing and laying 60 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
M&L for chain link MS galvanised fencing including lines wires, dia of chain link n less than 3.5 mm any mesh any size any type to any type strands rails, straining bolts etc complete all as specified and directed.
M&L for structural MS frame work half round or other stock section including securing posts and stuts in fencing, frame work for gates of substations, base frame for equipments including securing bolts, posts and sturts in fencing including cutting and makeing shapes as desired, drilling holes, notching for wire cut to size and made to the exisitng shape suitable for fixing MS chequred duct covers / door panels, including nuts, bolts and washers, welding / bracing works, bending cold or hot drilling holes for bolts in any shapeetc flat iron fillets (for securing wire mesh etc) all necessary drilling, bolting or riveting etc and similar work confirming to Fe-290 Gde E-165 including one coat of primer and two coats of synthetic enamel paint to the entire steel surfaces all as specified and directed.
Supply and fix central AC plan flow process diagram in PVC board (achrelic sheet) of size 3 m x 1.5 m indicating size & cacty of all equipments i.e. chhiler unit, compressor, condensor, pump set , valve etc in diffirent colour including all fixing arrangment complete all as speicified and directed.
M/S SHARADA ASOCIATE (BID ID -3274984)
SHRI HARI CONSTRUCTION (BID ID -3278640)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .