GE WEST HISAR
GE WEST HISAR, HISAR MIL STN, HISAR - 125006
SPECIAL REPAIR TO BLDG NO P-67 OF OLD YOUNG STOCK AT EBS HISAR, HISAR MIL STN UNDER GE (WEST) HISAR
2021_MES_471353_1
GE(W)HSR-19/2021-22
Open Tender
Civil Works
Item Rate
180 days
HISAR MILITARY STATION
Please refer tender documents
9 documents required · 9 mandatory
₹500
Yes
GE WEST HISAR
₹77,600
Yes
29 Oct 2021
28 Aug 2021
29 Sept 2021
28 Aug 2021
27 Sept 2021
13 Sept 2021
Amount
Demolition of stone slabs and tiles of any description or thickness in floors, aprons. laid bedded and pointed in any mortar including removing rubbish etc complete all as specified and directed.
M&L for 20 to 25mm thick machine cut Kota stone (550 x 550 mm) flooring over cement screed base laid and jointed with grey cement slurrry mixed with pigments to match the shade of the slab including rubbing and polishing complete all as specified over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed.
All as per item No 2.0 above but kota stone slab (100/150mm x 550mm) and 20-25mm thick in riser of steps, skirting , dados and pillar laid over and including 10mm thick rendering to receive the stone in cement mortar 1:3 and jointed complete all as specified and directed.
Dismantling floor, heath or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for coloured designed glazed ceramic tiles in vertical surface of size 350x250x7mm /450x350x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed.
M&L for 25mm thick cement concrete type B-0 , 1:2:4 (using 12.5mm graded stone aggregate ) fair finished as in levelling course to receive tiles complete all as specified and directed.
M&L for 50mm thick, cement concrete 1:3:6 type C1 using 20mm graded crushed stone aggregate as in plinth protection, finished even and smooth without using extra cement, including making joints 12mm wide to the full depth of PCC at every 3 metres and at every change of direction and filling the same with & including bitumen and sand 1:3 by weight complete all as specified and directed. .
Taking down cement plaster incl racking out joints, hacking for key & scrubbing down with water etc including removing rubbish complete all as specified and directed.
M&L for 15mm thick plaster in CM 1:4 on brick or concrete wall surface finished even and fair without using extra cement mixed with liquid water proofing admixture as per manufacturer's instructions complete all as specified and directed. Note :- WPC will be paid separately.
M&L for 15mm thick rendering in CM 1:6 over brick / concrete wall surfaces trowelled to even & fair w/o using extra cement for internal wall surfaces complete all as specified and directed.
M&L for 10mm thick rendering in CM 1:3 over brick / concrete ceiling surfaces trowelled to even & fair w/o using extra cement for internal wall surfaces complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed.
M&L for preparation of newly plastered surfaces on wall and applying two coats of cement base paint of any tint over one coat of primer complete all as specified and directed
M&L for preparation of old plastered surfaces of wall and applying one coat of cement base paint of any tint over one coat of primer complete all as specified and directed
M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
M&L for preparation of old decorated plastered surfaces of wall and applying one coat of white wash complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for preparation of old decorated plastered surfaces of ceiling and applying one coat of white wash complete all as specified and directed.
Demolition of brick work built in cement mortar including all quoins, arches pillars etc and removing rubbish complete all as specified and directed.
M&L for brick work with fly ash Bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 complete all as specified and directed.
All as per item No 20 above but except bricks. Note: old bricks obtained from demolition shall be reused.
M&L for brick work with fly ash Bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:4 in half brick thick complete all as specified and directed.
M&L for coloured chequered cement concrete tiles with grey cement and pigments 25CM x 25CM x 25mm thick and including provision of cement screed bedding layer 15 mm thick in CM 1 :6 etc set with neat grey cement slurry ,jointed and pointed in cement slurry and pigments in floor/ paths complete all as specified and directed.
Dismantling brick tiles or terracing tiles single layers as on roof and removing complete all as specified and directed .
Demolition of mud phuska on roof of any thickness including plastering and leeping whether full thickness removed or only a part there of removing debris to a distance exc 1 km but not exc 1.5 Km all as specified and directed.
M&L for cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate in padding, levelling courses and the like finish even & fair average 50mm thick or as required at site including Removal of old waterproofing treatment any type and preparation of RCC roof surfaces (old or new) with wire brush drying and cleaning to remove all foreign materials and washing with water to remove loose particles. Filling the cracks by crack filler complete all as specified and directed.
M&L for 40mm thick brick tiles laid on cement mortar 15 mm thick screed & jointed in CM 1:6 and pointed flush in cement mortar 1:3 mixed with 5% of crude oil by weight of cement on PCC padding complete all as specified and directed. Note : PCC padding will be measured and paid separately.
All as per item No 27 but except brick tiles. Serviceable qty of roof tiles obtained from item No 24 above.
M&L for plain cement concrete 1:3:6 type C-1( using 20mm graded crushed stone aggregate) as in roof kerbs complete all as specified and directed .
Demolition of cement concrete as in ground floors and pavings not exceeding 15 cm thick below or above ground level (unreinforced) incluiding removing rubbish complete all as specified and directed.
M&L for cement concrete type D2 1:4:8 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete, floor sub base etc. complete all as specified and directed .
M&L for 100mm thick cement concrete type B-2 , 1:2:4 ( using 40mm graded stone aggregate) as in floor / hardstanding surface finished even and fair complete all as specified and directed.
Taking up or down steel water tubing and connections including for re-fixing or remove from site 15 mm bore of pipe complete all as specified and directed.
Taking up or down steel water tubing and connections including for re-fixing or remove from site 20mm bore of pipe complete all as specified and directed.
S&F steel water tubing (medium grade) galvanised with all fittings and fixed complete to walls and ceiling or laid in floors 15 mm bore of pipe complete all as specified and directed.
S&F steel water tubing (medium grade) galvanised with all fittings and fixed complete to walls and ceiling or laid in floors 20 mm bore of pipe complete all as specified and directed.
S&F in repair vitreous china wash basin white flat back size 550 x 400mm size, incl cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe and 15mm pillar tap cast copper alloy with capstan head chromium plated complete all as specified and directed
S&F in repair 1000 litre capacity ISI marked double layered rotational molded polyethylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position including making inlet/outlet connection complete all as specified and directed.
S&F in repair 15mm bore bib tap, brass chromium plated cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed all as specified .
S&F in repair 15mm bore stop valve, cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed complete all as specified and directed.
S&F in repair 20mm bore stop valve, cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed complete all as specified and directed.
S&F in repair PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed.
Demolition of reinforded cement concrete of any description and in any position chajjas, roof projection, PCC railing, precast covers, Columns taken for pressure grouting including removing rubbish complete all as specified and directed.
M&L for providing precast reinforced cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in cover slabs (for manholes etc), shelves and similar articles with plain faces including necessary moulds and setting in cement mortar 1:4 including demolition of existing RCC cover slabs complete all as specified and directed. (Note :reinforcement to be measured separately)
M&L for providing RCC 1:2:4 type B-1 (20mm graded stone aggregate) as in Beams, cantilevers, Chajjas , lintels complete all as specified and directed.
Removing all disintegrated and loose concrete of any thickness including plaster if any in RCC Column, Chajja, slab, beams, lintels etc, removing all loose rust/scale form exposed reinforcement bars by using wire brushes and sand paper including cleaning of exposed reinforcement bars by using wire brushes and sand paper including cleaning of exposed surfaces of reinforcement with protective anti corrosive epoxy bonding chemical (Make : Pidilite) and including tied reinforcement bars / IRC fabric 50mm x 50mm x 12guage if required to reinforcement concrete bonding primer uniformly to exposed surfaces and applying cement mortar 1:3:1 with WPC (1 Part Cement : 3 part sand : 1 part 6mm coarse aggregate) to an average thickness not less than 20mm and removing debris complete all as specified and directed.
M&L for RCC M-25 (Design mix) 20mm graded aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick flat rough finished surface complete all as specified and directed.
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.rough finished surface complete all as specified and directed.
M&L for MS TMT bar 10mm dia or over cut to length bent to shape reqd incl cranking bending etc complete & binding with MS wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for mild steel TMT bars upto 8mm dia and over cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire 0.9 mm dia complete all as specified and directed.
All as per item No 51 above but for 5mm dia and over upto and incl 10mm dia in stirrups, spacers and binders.6 to 8mm dia complete all as specified and directed.
S&F in reapair 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls with suitable mild steel clamps
Taking down carefully copper/aluminum point wiring (light/fan/socket or power) complete including taking out existing unserviceable terminal boxes & conduit with switches/sockets/fan regulators and fittings such as ceiling rose, pendants, tube light fittings, lamp holders, brackets light fittings, rectangular blocks etc. and making good disturbed surface of walls, floors etc. to match with the existing surface etc complete all as specified and directed.
M&L for point wiring for one light / bell / Ceiling fan/Exhaust Fan point controlled by one switch with 1.5 Sqmm (nominal area) PVC insulated, unsheathed multi strand copper conductor cable FRLS drawn through rigid PVC coduit 20 mm dia medium grade and conduit accessories concealed type in walls/ceilings and including change of steel terminal sunken boxes and 3 mm thick phenolic laminated sheet top cover for sunken boxes flush to surface for one light point/fan point, controlled by one switch on the same board with other switch or independent including PVC insulated unsheathed 1.5 Sqmm copper conductor cable FRLS connected to common earth dolly complete complete all as specified and directed. (Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of BoQ' ).
All as per item No.55 above but for one 5 Pin 5 Amp socket outlet on the same board controlled by one number one way switch on same board.
All as per item No.55 above but for one 5 pin 5 Amp socket outlet on independent board controlled by one number one way switch on independent board.
S&F flush type socket outlet multipurpose 2&3 Pin, 5/6 Amp 230 volts AC complete all as specified and directed.
S&F switch piano flush type, single pole, one way, 5/6 Amp, 230/240 Volts grade complete all as specified and directed.
S&F Lamp holder of PVC / Polycarbonate type surface with 9 watt LED bulb complete all as specified and directed.
S&F ceiling rose surface bakelite, 3 terminals with back plate etc complete all as specified and directed.
S&F LED tube light fitting 18W metallic frame /batten, Retro, Box type surface and wall mounted, including LED tube light rod high efficiency including making connection, complete all as specified and directed.
S&F LED flood light fitting 70 watts , 230 volts high efficiency including making connection, complete all as specified and directed.
S&F electronic fan regulator stepped type 230 volts complete all as specified and directed.
S&F MCB SPN, 32 to 40 Amps 240 Volts , type 'B' curve, 10 KA, for fixing in DB complete all as specified and directed.
S&F MCB SP, 6 to 32 Amps 240 Volts , type 'B' curve, 10 KA, fixing in DB complete all as specified and directed.
S&F Sheet metal enclosures for DBs when MCBs to be used Single pole and neutral (SPN 240 Volts) with 200 Amps rated busbar 8 way double door complete and all as specified and directed
Taking down carefully copper/aluminium Submain wiring from battan /conduit from DBs,MCBs, etc) and making good to disturbed surfaces of walls, floor etc. all as specified and directed
S&F Sub main wiring with two single core cable PVC insulated unsheathed of copper multi stranded conductor FRLS cable of size 4 sqmm, 1100 votls grade drawing through and including PVC casing and caping with acessories and including PVC insulated 4 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly complete all as specified and directed. (Note:- Two lengths of 4 Sqmm cable, one length of 4 Sqmm cable and one length of PVC casing and caping will be measured as one length).
Supplying laying, jointing, testing and commissioning of LT UG XLPE insulated screened PVC beded galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 volts grade of size 16 sqmm 2 core including taking down old U/S cable complete all as specified and directed. (Note :- cable may be laid in trenches, under road, across the nallah, along poles/walls and in ducts etc . Eexcavation, earhtwork, sand cushioing, cable cover, pipe for cable protection to be measured and paid for separtely) complete all as specified and directed.
Supplying laying, jointing, testing and commissioning of LT UG XLPE insulated screened PVC beded galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 volts grade of size 6 sqmm 2 core including taking down old U/S cable complete all as specified and directed. (Note :- cable may be laid in trenches, under road, across the nallah, along poles/walls and in ducts etc . Eexcavation, earhtwork, sand cushioing, cable cover, pipe for cable protection to be measured and paid for separtely) complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/ equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore upto 7.50 metre long GI pipe light grade for earth wire protection fixed with poles/wall with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing.
virendra constructions
SHRI HARI BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .