Loading…
Loading…
Tender Value
Refer Docs
Closing Date
20 Sept 2024, 5:00 pmClosed
Narad Muni Gupta
Irugur TOP Installation, Bharat Petroleum Corporation Limited
SUBJECT: “ Upgradation of Control Room – S & F of New Console workstation, Smoke detector & controller, Providing & construction wooden Workstation & QA Showcase, Shifting of Existing Console Workstation” 1. You are invited to submit your offer as E-bids in two-part for the above work on the terms and conditions contained in this tender document. 1. This tender document consists of the following annexure, which are enclosed: a. General conditions of contract b. Special condition of Contract c. Scope of work d. Tender Work Sheet (BOQ) e. Safety requirement (Health, Safety & Environment) <p class="MsoNo Dear Sir/Madam, SUBJECT: “ Upgradation of Control Room – S & F of New Console workstation, Smoke detector & controller, Providing & construction wooden Workstation & QA Showcase, Shifting of Existing Console Workstation” CRFQ NO: 1000423182 SYSTEM ID: 17693 due on 26.09.2024 @17:00 hrs 1. You are invited to submit your offer as E-bids in two-part for the above work on the terms and conditions contained in this tender document. 2. This tender document consists of the following annexure, which are enclosed: a. General conditions of contract b. Special condition of Contract c. Scope of work d. Tender Work Sheet (BOQ) e. Safety requirement (Health, Safety & Environment) f. Bid Declaration Form - Annexure-F g.<span
17693
1000423182
Limited Tender
Works
Irugur TOP Installation
28 Sept 2024
5 Sept 2024
23 Sept 2024
6 Sept 2024
20 Sept 2024
6 Sept 2024
6 Sept 2024 - 18 Sept 2024
“Upgradation of Control Room – S & F of New Console workstation, Smoke detector & controller, Providing & construction wooden Workstation & QA Showcase, Shifting of Existing Console Workstation”
Tender Worksheet
SL NO: | SERVICE CODE | SHORT DESCRIPTION | Service No | Service Text | UOM | QUANTITY | UNIT RATE IN RS. | TOTAL COST
1 | 9008148 | ET-2, 18mm Top | Providing and constructing wooden table made out of 18mm thick top/carcass, 12mm thick drawers/back using commercial plywood of Anchor 2000 or approved equivalent make. The table top to be provided with additional 3" wide, 18mm thick plywood all around. The table top/top sides to be provided with 12mm thick Corean solid surface (with buffing) and laminate of approved make as per the drawing.The table shall be provided with 1 no. drawer box unit of approximate size 18"x 27" x 24" with required no. of drawers, openable shutters as per drawing. The cost to include necessary hardware, SS/brass handles/knobs, drawer locks of Godrej or approved eqvt. make , brass hinges, telescopic drawer channels of ebco or approved eqvt.make etc. All internal surfaces to be finished with french polish. | M2 | 3.0 |
2 | 9008120 | LHT STOR-16"D | Providing and constructing 16" deep low height storage cabinets made out of 18mm thick commercial plywood carcass/shutters and back with 6mm thick commercial plywood of Anchor 2000 or approved equivalent make. The storage cabinets shall be provided with required nos. of shelves in 18mm thick commercial plywood and all internal surfaces to be finished with french polish. The rate to include hardware, brass hinges, locks of 'Vijayan' or approved equivalent make, brass tower bolts, SS handles/knobs of Kich or approved equivalent make, ball catcher etc. complete | M2 | 9.0 |
3 | 9008238 | Fire Alarm Panel 2zone | Providing, fixing, testing and commissioning Fire Alarm Control Panel (Addressable type) comprising of a) 2 zone control system with built in hooter b) Fire/Open/Short/Test alarm and indication of various zones c) Rectifier/Charger with control fuses, 15A plug top using 3x2.5 sq.mm. copper unarmoured cable d) 16G painted CRCA casing complete with mounting brackets and fixing accessories e) Panels to have Alpha Numeric display showing exact location of the fire detected. The panel to have re-chargeable maintenance free dry battery with provision of dual rate battery charger to run for 48 hrs. in quiescent condition and 1/2 hr. of alarm condition as directed. | EA | 1.0 |
4 | 9004725 | SMOKE DETECTOR | Supply n installation (if required removing the old one, which will be the property of BPCL) Smoke Detectors with mounting base, LED etc. complete as required and suitable for site. | EA | 25.0 |
5 | 9023723 | S/L CAB 1PX1.5MM2 | Cables :Supplying, Laying; Testing and Commissioning Of 1.1 Kv Grade Cables ;PVC Insulated (Fire Retardant Low Smoke) ; Pvc Sheathed; Armoured copper Conductor Cables of Following Sizes As Per Is:1554 (Part-I), and Sealed properly with Pvc Caps In Built-Up Ready Made Trenches; Overhead Cable trays;Pull through Pipes Or Exposed On Wall .Beam/Rakes; Trusses Tie/Beamor Embedded In Floor Or buried Directly Underground (Excavation, sand and bricks shall be paid under seperate item of BOQ) Or Through G. I.Pipe.Unit Rates Quoted For Installationof Cables Shall Be Same Irrespective Of Route and Method Of Laying. The rates Shall Include Laying, Pulling Of Cables, Proper Dressing Of Cables on Cable Trays, Racks, Vertical Raceways and Supply and Installation Of saddles, Spacers and Nylon Chord For Tying As Required,Identification Tags At Strategic Points/ Every 50 Meter Intervales,aluminium Clamps. etc. Cable Identification Tags At Strategic Points/ Every 50 Meter Interval For Identification Of Cable; Etc. Complete.The Straight Through Joints/ tying with armour In The Cables Should Be avoided.
Procedure for laying of LT cables.MAKES/SPECIFICATIONS | RM | 200.0 |
6 | 9020869 | S/L CAB 3CX2.5MM2 | Cables :Supplying, Laying; Testing and Commissioning Of 1.1 Kv Grade Cables ; Pvc/XLPEinsulated; Pvc Sheathed; FRLS Armoured copper Conductor Cables of Following Sizes As Per Is:1554 (Part-I), IS 7098 Part I & IS 1225-Latest Version and Sealed properly with Pvc Caps In Built-Up Ready Made Trenches; Overhead Cable trays;Pull through Pipes Or Exposed On Wall .Beam/Rakes; Trusses Tie/Beamor Embedded In Floor Or buried Directly Underground (Excavation, sand and bricks shall be paid under seperate item of BOQ) Or Through G. I.Pipe.Unit Rates Quoted For Installationof Cables Shall Be Same Irrespective Of Route and Method Of Laying. The rates Shall Include Laying, Pulling Of Cables, Proper Dressing Of Cables on Cable Trays, Racks, Vertical Raceways and Supply and Installation Of saddles, Spacers and Nylon Chord For Tying As Required,Identification Tags At Strategic Points/ Every 50 Meter Intervales,aluminium Clamps. etc. Cable Identification Tags At Strategic Points/ Every 50 Meter Interval For Identification Of Cable; Etc. Complete.The Straight Through Joints/ tying with armour In The Cables Should Be avoided.
Procedure for laying of LT cables.MAKES/SPECIFICATIONS | RM | 100.0 |
7 | 9019162 | CAT6 CABLE | Supply and laying of CAT6 data cable from HUB to individual RJ 45 sockets through already laid PVC pipes and connection at both ends using crimping tool | RM | 300.0 |
8 | 9019161 | TELEPHONE WIRING 5P | Supply and laying of 5 pair standard telephone cable from exchange KRONE box to individual telephone sockets through already laid PVC pipes and connection at both ends | RM | 150.0 |
9 | 9019104 | POINT WIRE 6-10M | POINT WIRING :Supply & Laying primary Point Wiring from Switch Board to the lighting Fixture/Celing Fans Exhaust Fans/Call Bell lamps/ by means of 3 runs of 1.5 sq.mm. PVC FRLS 650 Volts/1100 Volts grade ISI approved & ISI marked. PVC Insulated Stranded copper Conductor through existing recessed/Surface Conduits in an approved manner. This Shall Include the supply & Installation of Single Pole 5-Amps Modular Switch of approved Make in modular recessed box complete with all labour and materials for the following distances (Supply of Modular Recessed Box not in scope) | NO | 10.0 |
10 | 9019191 | OUT DATA RJ45 | Supply, Installation, Testing and Commissioning of DATA outlet (RJ-45)with required size PVC back boxes, face plates, accessories etc.complete. | EA | 2.0 |
11 | 9017090 | Shifting of Console Panel | Shifting of electrical panel incl. Disconnecting all cables, glands etc. & making re-connections at shifted place. Jobs also incl. Dismantling / re-fixing of panel asreqd. incl. Cost of material & labour etc. complete. | EA | 1.0 |
12 | 9013846 | INS . . SYSTEM CABINET | NEW OIC Automation table 5 seater table | EA | 1.0 |
13 | 9001191 | Maintenance . Bldg ELECTRICAL | Integration for New Fire Alarm Panel with existing fire alarm panel & existing smoke detector , New Smoke Detector of ATF control Panel | LS | 1.0 |
Seal & Signature of Vendor
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
17693.zip
zip • 6.31 MB
BUDGETDOC_17693.xlsx
xlsx • 0.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .