Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.5 LAccepted-AOC 15A 9 CHOWBHAGA ROAD KOLKATA KOLKATA 700039 | KOLKATA | WEST BENGAL | 700039 | L1 | Accepted-AOC Due to being L1 | |
| 2 | L2₹15.1 L+₹1.3 L (9.23%)Rejected-Finance WARD NO 16 HOUSE NO 66 SALLIAN TALAB UDHAMPUR 182 101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-Finance OTHER TAHN L1 |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
18 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITIES UDHAMPUR
GE UTILITIES UDHAMPUR PO GARHI PIN 182121
Repair/maintenance of AC plants cooling towers at CHNC, 37 AMSD area under GE (Utilities)Udhampur
2021_MES_476523_1
GE/U-41/2021-22
Open Tender
Miscellaneous Works
Item Rate
270 days
GE UTILITIES UDHAMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE UTILITIES UDHAMPUR
₹30,000
Yes
20 Dec 2021
20 Sept 2021
25 Oct 2021
20 Sept 2021
18 Oct 2021
4 Oct 2021
60 days
Amount
Carry out Servicing, Oiling, Greasing and Cleaning of window type/ split type AC from authorised rep or service engineer from the manufacturer with high pressure pump of 1.0/1.5/2.0 ton capacity, checking of defects/ leaking and adjusting setting to work and testing complete all as specified and directed by Engr-in-Charge.
Cutting of suction line and discharge line tubing of AC, de-scaling of front scaled unit flushing out condenser and cooling coil thoroughly and reconnecting with the seal unit and charging of gas with required qty of refrigerant gas for 1.0/1.5/2.0 ton Split/Window type AC
Detection/rectification of leakage of gas by vacume the system, charging with Nitrogen gas and vacume the system after detaction of lekage and refrigerant gas charging in the system with appropriate quantity of refrigerant gas as per OEM Recommendation including testing for smooth functioning of Split type/ Window type AC of capacity 1.0/1.5/2.0 Ton complete all as specified and directed by Engr-in-Charge.
Supply and topping up of refrigerant gas R-22 in Split air conditioner of capacity 1/1.5/ 2 TR.
Supply and topping up of refrigerant gas R-410 in Split air conditioner of capacity 1/1.5/ 2 TR.
Supply and topping up of refrigerant gas R-600 in refrigerantor.
Supply and topping up of refrigerant gas R-134 in Water Cooler and Referigerator .
New indoor unit of split AC of capacity 1.5 ton (in replacement) with compitable to existing out door unit from authorized dealers of company complete all as specified and directed by Engr-in-Charge. Make: Voltas/LG
New indoor unit of split AC of capacity 2.0 ton (in replacement) with compitable to existing out door unit from authorized dealers of company complete all as specified and directed by Engr-in-Charge. Make: Voltas/LG
New outdoor unit of split AC of capacity 1.5 ton (in replacement) with compitable to existing indoor door unit from authorized dealers of company complete all as specified and directed by Engr-in-Charge. Make: Voltas/LG
New outdoor unit of split AC of capacity 2.0 ton (in replacement) with compitable to existing indoor door unit from authorized dealers of company complete all as specified and directed by Engr-in-Charge. Make: Voltas/LG
Running capacitor of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity (in replacement) complete all as specified and directed by Engr-in-Charge.
Starting relay of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity (in replacement) complete all as specified and directed by Engr-in-Charge.
Print circuit Board (PCB) of Existing Make duly ISI marked for split type AC 1.0/1.5/2.0 Ton capacity (in replacement) complete all as specified and directed by Engr-in-Charge.
Print circuit Board (PCB) for inverter type split AC of existing makes duly ISI marked for 1.5 /2.0 Ton capacity (in replacement) complete all as specified and directed by Engr-in-Charge.
Print circuit Board (PCB) of Existing Make duly ISI marked for window type AC 1.0/1.5/2.0 Ton capacity (in replacement) complete all as specified and directed by Engr-in-Charge.
Thermostat switch of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity (in replacement) complete all as specified and directed by Engr-in-Charge.
Blower motor of Split type AC 1.5/2.0 Ton of existing make & model (in replacement) complete all as specified and directed by Engr-in-Charge.
New rotary type AC compressor of existing split type/window type AC from authorized dealers of OEM capacity 1.5 Ton (in replacement)complete all as specified and directed by Engr-in-Charge.
All as item No 19 but for 2.0 ton capacity.
New Reciprocating type AC compressor of existing split type /window type AC from authorized dealers of OEM capacity 1.5 Ton (in replacement) complete all as specified and directed by Engr-in-Charge.
All as item No 21 but for 2.0 ton capacity.
Evaporator coil 1.5 / 2.0 Ton (in replacement) complete all as specified and directed by Engr-in-Charge.
Suction/Discharge valve (in replacement) complete all as specified and directed by Engr-in-Charge.
Copper tube of size 1/4 inches for 1.5 /2.0 Ton split AC (in replacement) complete all as specified and directed by Engr-in-Charge.
Copper tube of size 1/2 inches for 1.5 /2.00 Ton split AC (in replacement) complete all as specified and directed by Engr-in-Charge.
Copper tube cover (insulation) (in replacement) fixed over the copper tube of size 1/4" or 1/2" as directed by Engr-in-Charge. Note: insulation of 1/4" & 1/2" dia pipe measured as one unit.
Drain pipe rigid and flexible 20mm dia with clamps of suitable size as per site requirement complete all as specified and directed by Engr-in-Charge.
Reverse cycle valve for window type AC/ Split Type AC of capacity 1.5 Ton /2.0 Ton including welding, brazing (in replacement) complete all as specified and directed by Engr-in-Charge.
Carry out Servicing, Oiling, Greasing and Cleaning of water cooler of any capacity from authorised rep or service engineer from the manufacturer with high pressure pump, checking of defects/ leaking and adjusting setting to work and testing complete all as specified and directed by Engr-in-Charge.
Detection/rectification of leakage of gas in the system and gas charging in the system with appropriate quantity of gas including testing for smooth functioning of water cooler of any capacity complete all as specified and directed by Engr-in-Charge.
Compressor reciprocating type (hermetically) sealed for capacity 40/80 litre water cooler complete all as specified and directed by Engr-in-Charge.
Starting relay and overload relay suitable for existing size and make water cooler (in replacement) complete all as specified and directed by Engr-in-Charge. Make: Epcos/Asian
Dismantling of old defective condenser fan motor of water cooler of any make and capacity and refixing and testing the same after rewinding with super enameled copper wire of existing gauge or gauge as approved by Engineer-in-Charge including replacement of shaft/ bush etc complete all as specified and directed by Engr-in-Charge.
Fan blade of condenser motor of any make and capacity of water cooler /AC /Ref or deep freezer (in replacement) complete all as specified and directed by Engr-in-Charge.
Carry out Servicing, Oiling, Greasing and Cleaning of Deep freezer of capacity 300/320 ltr from authorised rep or service engineer from the manufacturer with high pressure pump, checking of defects/ leaking and adjusting setting to work and testing complete all as specified and directed by Engr-in-Charge.
Starting relay of deep freezer of any size and make (in replacement)complete all as specified and directed by Engr-in-Charge.
Gas charging in deep freezer any make and capacity including testing of leakage complete all as specified and directed by Engr-in-Charge.
Repair , servicing and maintenance of refrigerator of any capacity including replacement of following UNSV Parts starting relay - 01 No., over load relay-01 No, capacitor 20 mfd -01No, thermostate switch - 01 No, Door rubber beeding set - 01 Set complete all as specified and directed by Engr-in-Charge.
New sealed compressor (in replacement) suitable for single phase, 230 Volt, 50 Hz Refrigerator / Deep Freezer of any Size including refrigerant gas filling up to required level complete all as specified and directed by Engr-in-Charge.
Thermostat switch (in replacement)for refrigerator any make & capacity complete all as specified and directed by Engr-in-Charge.
Repairing /Servicing and rewinding of motor 3 phase 400-440 volt complete, disconnecting the electric supply, removing of pully and fan and opening of both end covers, taking out Bearings and rotor, checking of air gap, checking of rotor field winding, replacement of bearings, greasing of bearings including rewiring with superior quality copper winding wire insulating material, vamishing binding of winding etc including reassembling, replacing rusted nuts, bolts, washers, checking and adjusting the alignment, connecting electric connection complete all as specified and directed by Engr-in-Charge for the following :-
Electric motor 3 phase 40 HP of AC Plant.
Electric motor 3 phase 15 HP of AC Plant.
Electric motor 3 phase 10 HP of AC Plant.
Electric motor 3 phase 5 HP of AC Plant.
Electric motor 3 phase 3 HP of AC Plant.
Description all as per srl item No 42 here-in-before, but including removing of old gland packing, gland bolt and supply and fixing of new gland packing , gland bolt, cleaning of impeller/Replacement of impeller all as directed (Impeller shall be measured and paid for separately) for the following :-
Monoblock pumping set 10 HP.
Monoblock pumping set 7.5 HP.
Monoblock pumping set 5.0 HP.
Descaling of condenser after opening of both end cover, circulation of descaling solution forcibly using pump for circulating descaling solution and roding manually using nylon brush of size 1/4,3/8,1/2,5/8 inch descalling rod etc without damaging copper tubling and refixing of side cover using new gasket of rubber incersion sheet of 3mm thick and replacment of rusted nuts bolts etc complete all as specified and directed by Engr-in-Charge for the following:-
47.5 TR cap Condenser
7.5 TR cap Condenser
5 TR cap Condenser
Descaling and flushing of cooling coil complete with chemical brushing to fins, bends and cleaning complete all as specified and directed by Engr-in-Charge for the following:-
95 TR Capacity Plant
15 TR Capacity plant
Repairing, servicing of cooling coil tower of AC plant FRP type by dismantling and taking out the one comb PVC tiles and PV Nozzels by suitable descaling solution including brushing and cleaning complete with cleaning solution and water, replacing the defective PVC flange alongwith rubber gasket and rusted bolts, nuts and washer etc, cleaning the water sump and XMP wire mesh with suitable cleaning solution, re-assemblig the same including replacing the defective water filter, flanges of pipe joints etc., and testing complete all as specified and directed by Engr-in-Charge for the following plants:- (PVC tiles will be measured ad paid separetely)
15 TR Capacity plant installed at 37 AMSD A/C Plant.
95 TR Capacity plant installed at OT CC.
Servicing of compressor unit by draining out the used compressor oil, opening both side covers, head covers and taking out the defective oil filter, cleaning the sump by using suitable cleaning solution, replacing the defective oil filter element, checking of solution and discharge valve, adjust them and refixing the side covers, head covers including replacing the suitable gasket complete and re-filling of new compressor oil to the required level, removing the pull, checking the serviceability of shaft seal assembly, replacement of shaft assembly and refixing the pull including replacing the defective gas filter and testing complete all as specified and directed by Engr-in-Charge for the following :- (Oil filter element gas filter and shaft seal will be measured and paid for separately)
Compressor model JS43F 50B installled at 37 AMSD of 7.5 TR/5 TR Capacity.
Supply and replacement of following items complete all as specified and directed by Engr-in-Charge:-
Different pressure control switch Type MP-55. Make: Indfos/Danfos
Low pressure cut out control switch MP-I. Make: Idofos/dafos
Pressure cut out control switch MP-5. Make: INDFOS/DANFOS
Oil pressuer cut out off switch MP-15. Make: INDFOS/DANFOS
Oil pressure gauge 0 to 300 PSI. Make: FIEBEG/GURU
Compound gauge (- 30 to 0 to 300 PSI). Make: FIEBEG/GURU
Compoud gauge (- 30 to 0 to 150 PSI). Make: FIEBEG/GURU
Water pressure gauge (-0 to 150 PSI). Make: FIEBEG/GURU
Hand shut off valve of size 1/4 x 1/4.
Solenoid control valve suitable for central AC Plant upto 95 TR Cap.
Condenser safety valve for central AC plant up to 95 TR .
Supply only 3 pole power contactor Type ML-1.5, 415/210 volt 50 Hz AC 16 Amps complete all as directed by Engr-in-Charge. Make: L & T/ABB/SCHNEIDER
Supply only 3 pole power contactor Type ML-4, 415/210 Volt 50 Hz AC 32 Amps complete all as directed by Engr-in-Charge. Make: L & T/ABB/SCHNEIDER
MCCB Three pole 415 Volt 50 Hz 160 Amps with breaking capacity 25 KA type DT complete all as directed by Engr-in-Charge. Make: L&T/ABB/SCHNEIDER/ SIMESE
MCCB Three pole 415 Volt 50 200 Amps with breaking capacity 25 KA type complete all as directed by Engr-in-Charge. Make: L&T/ABB/SCHNEIDER/ SIMESE
Over load relays MK 1 Type relays range 4 to 6.5 Amps,1.5 to 2.5 Amps, 6 to 9 Amps, 9 to 14 Amps, 11 to 18 Amps complete all as directed by Engr-in-Charge. Make: L & T/Autoix/MDS/SIMEMS or Equivalent
Over load relays MK-1 Type relays range 60 to 100 Amps,37 to 60 Amps, individual mounting, complete all as directed by Engr-in-Charge. Make: L & T/Autoix/MDS/SIMEMS or Equivalent
Over load relays MK-1Type relays range 11 to 18 Amps, 9 to 14 Amps, 6 to 9 Amps, 9 to 14 Amps, 11 to 18 Amps complete all as directed by Engr-in-Charge. Make: L & T/Autoix/MDS/SIMEMS OR Equivalent
AC Amps meter 0 to 30 Amps direct reaching type complete all as directed by Engr-in-Charge. Make: AE/PL/L&T/Standard.
AC Amps meter 0 to 60 Amps complete all as directed by Engr-in-Charge. Make: AE/PL/L&T/Standard
AC Amps meter 0 to 100 Amps complete all as directed by Engr-in-Charge. Make: AE/PL/L&T/Standard
AC Amps meter 0 to 300 Amps complete all as directed by Engr-in-Charge. Make: AE/PL/L&T/Standard
AC Voltmeter electronic, digital type 0 to 500 V as per sample complete all as directed by Engr-in-Charge. Make: AE/PL/L&T/Standard
Electronic timer switch 240/415 volt 50 Hz for 30 to 60 seconds complete all as directed by Engr-in-Charge. Make: GIC/L&T
Single phase prevetor suitable for 415 volt 50 Hz 3 phase as per existing type complete all as directed by Engr-in-Charge. Make: L&T /Siemes
Taking out the defective thermostatic expansion valve and supply and fix thermostatic expansion valve suitable for the following :-
Central AC Plant 95 TR complete all as directed by Engr-in-Charge. Make: ALCO/IFOS
Central AC Plant 15 TR Capacity complete all as directed by Engr-in-Charge. Make: ALCO/IDFOSS
Pre-filter 10 to 20 micros stetic o wave both side DPE mesh I alumnium frame efficiecy 90% of sizes as per site requirement. Make of Filter RAVI/ATLETE
V Belt of following sizes:-
V-Belt B-67
V-Belt B-68
V-Belt B-70
V-Belt B-124
Supply only compressor oil sealed container maufactured by Hindustan Petrolium limited as per site requiremet or equivalant as directed by Engr-in-Charge.
Rectification of any breakdown of AC Plant of capacity 47.5 TR/ 7.5 TR whenever required round the clock ,rectify the fault and restart the plant within three hour after receipt of complaint of any nature i.e. Compressor, Condencer, Colling tower , AHU,control panel etc . Note :- (i) The cost of replaced spare parts will be paid and measured seperatly. (ii) If complaint is not attended by contractor with in five hour the penality of Rs 500 / per hour to be imposed and amount of penality will be deducted from RAR. (iii) The cost of transportation (to and fro) for all kind of necessary equipment / T&P shall be arranged/brought by contractor to complete the job at site or at E/M yard and no extra cost shall be paid to the contractor to this effect. (iv) Complaint shall be lodged by telephonically ,so contractor to specify the telephone no who will receive the complaint round the clock.
Thermal insulation to chiller pipe line with one coat of bituminous paint Polysheet fiberglass wool thickness of the same should be 50 mm wiremess and cover with POP/White cement with painting to match the existing complete all as specified and directed by Engr-in-Charge.
Disconnecting and isolating the compressor of Accel Make SMC 6- 100 Model from the existing AC system by putting plates to suction and discharge valve, opening of the compresssor, removing of internal parts, cleaning of the oil parts throughly replacemet of certain parts including thrust washers,mirror parts like nuts , bolts etc including polishing to the crank shaft, reassembling back all the serviceable parts after complete overhauling, removing of the drum plates of the compressor including testing, commissioning complete all as specified and directed by Engr-in-Charge. Note : Spare parts & cosumable will be measured & paid separately. Also charging of compressor oil will be measured & paid separtely.
Replacement of following spare parts for Accel Make SMC-6-100 Model Compressor including taking down old unserviceable spare parts complete all as specified and directed by Engr-in-Charge:-
Main bearing pump and seal end
Cylinder liner
Piston
Piston ring
Suction Strainer
SV Reeds
Discharge valve assembly
CR Bearing
Gasket Set
Crank Shaft for suitable size
O ring Set
Rocker arm frame
Oil pump gear
Connecting Rod
Valve springs.
Servicing of air Handling Unit of capacity 90 TR by opening of both side cover, taking out the Fresh air filter, cleaning the external & internal surface of AHU, primary air filter, wire mesh filter, Tumble Blower fan and refixing the side covers, head covers after painting & neccessory welding including replacing the suitable gasket complete all as specified and directed by Engr-in-Charge. Note: (Neccessory Nut, Bolts, washers, packings are included in quoted rate )
Servicing of air Handling Unit of capacity 15 TR by opening of both side cover, taking out the Fresh air filter, cleaning the external & internal surface of AHU, primary air filter, wire mesh filter, Tumble Blower fan and refixing the side covers, head covers after painting & neccessory welding including replacing the suitable gasket complete all as specified and directed by Engr-in-Charge. Note: (Neccessory Nut, Bolts, washers, packings are included in quoted rate )
Replacement of Tumble Blower fan of AHU Capacity 4000 CFM (size 24" dia, 24" Length, made by MS Steel) Mounted on 3"dia shaft including external cover complete all as specified and directed by Engr-in-Charge. Note: (Neccessory Nuts, Bolts, washers, packings are included in quoted rate )
Shaft seal assembly of a make of compressor including removing of the userviceable shaft seal assembly and testing complete all as specfied and directed by Engr-in-Charge.
Disconnection & dismantling old unserviceable meter gauge panel indoor type and supply, installation and testing of indoor vertical type gauge panel board made out of 2mm thick MS Sheet & GI pipe of medium grade, 80mm dia as per required length comprising of the following :- (a) Suction Pressure 0 to 150 PSI. (b) Oil Pressure gauge 0 to 300 PSI. (c) COP gauge 0 to 300 PSI. (d) DP gauge - 0 to 400 PSI. (e) ON OFF switch with all type of indicators (f) LP/HP/OP Pressure cutouts. Note: (i) All pressure gauge & cut out will be paid separtely under relavent item of BOQ (ii) Quoted rate by the contractor shall be included checking and tightning of all connection with meter gauge and replacement of userviceable copper pipe of 1/4 dia. LP/P Pressure cut outs. OP pressure cut outs. Water pressure cutouts. Copper Tube of Size 1/2 inch dia. Copper Tube of size 1/4 inch dia.
Dismanting of old unserviceable Sprinkler carefully & suppply & fix new Sprinkler made out from aluminium die casting suitable for upto 100 TR Capacity cooling tower etc complete all as specified and directed by Engr-in-Charge.
Replacement of old/unserviceable water thermostatic 0 to 30 degree centigrade including necessary connection and testing complete all as specified and directed by Engr-in-Charge.
Taking out of old userviceable butterfly valve form existing pipe line & supply and fixing new butterfly valve of size 100mm dia made out of mild steel including necessary modification of existnig pipe line & replacment of flanges with new bolts & nuts etc including all connected works complete all as specified and directed by Engr-in-Charge. Make:- Advace /Audco/Kirloskar/ Neta
New syphon connection of half inch size made out of GI Pipe with SS coating suitable for fixing of existing pressure gauge including stop cock of suitable size and all minor items & taking down old userviceable syphon connection complete all as specified and directed by Engr-in-Charge.
Water pressure gauge 0 to 10 KG 2/4 dia suitable for condenser chillar water line including removing old userviceable pressure gauge etc complete all as specified and directed by Engr-in-Charge.
Factory made performance bag filters of 99 micro down to 5 micro of standard size with multiple pockets & self supporting filters bags with MS/GI anodised aluminum frame suitable for central AC Plant including replacement of bolts & nuts & taking down userviceable performance bag filters complete all as specified and directed by Engr-in-Charge Make:- Aerosol/da/Mat/Zoflower.
Taking out old existing unserviceable metal plug socket and supply and fix new metal plug and socket board complete enclosure with single pole & neutral and earth plug with MCB SP 32 Amps, 220 Volts suitable for window/ Split type AC complete all as specified and directed by Engr-in-Charge.
Taking out old existing unserviceable DB two Way and MCB SPN 40 Amps and Supply and fix Sheet Metal Enclosure with DBs single pole and neutral 2 Way, 240 volts with one SPN MCB of capacity 40 Amps complete all as specified and directed by Engr-in-Charge.
MCB SPN 63 Amps, 10 KA,240V, 50Hz, 'C' Series (in replacement) complete all as specified and directed by Engr-in-Charge.
Taking out old existing unserviceable front show grill and supply and fix new front show grill for LG/Voltas /Sidwal/Godrej window type AC 1.5 Ton complete all as specified and directed by Engr-in-Charge. (as per sample approved by GE)
Disconnecting from electrical system and dismantling the voltage stabilizers of capacity 7.5KVA,5KVA,2KVA,1KVA and 0.5KVA, carrying to the workshop for complete checking,cleaning all parts by brushing and reassembling after replacement of unserviceable parts / componenets and back to store/site including testing and comminssioning for following components:-
Rewinding of main coil (primary/secondary) with super enameled copper wire of existing size including varnishing and insulation material of capacity 7.5KVA.
All as per ser item No.86 here - in-before but of capacity 5KVA.
All as per ser item No.86 here - in-before but of capacity 2KVA.
All as per ser item No.86 here - in-before but of capacity 1KVA.
All as per ser item No.86 here - in-before but of capacity 0.5KVA.
Relay for 7.5KVA & 5KVA,30amp 24volts DC (in replacement).
Step down transformer 24 volts 2Amp for 7.5 KVA & 5KVA (in replacement).
Circuit plate with connection wire (in replacement).
Relay for 0.5KVA, 1KVA & 2KVA,16Amp 24V DC (in replacement).
Voltmeter 0- 300V, AC 75 Sqm (in replacement).
Ampre meter 0- 30Amp, AC 75 Sqm (in replacement).
Push switch (in replacement).
Time delay circuit (in replacement).
Connector switch 30amp 220volts AC (in replacement).
LUXMI ELECTRONIC WORKS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .