| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.0 LAccepted-AOC MHN 284 DRIVER HILL VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹53.5 L+₹8.5 L (18.9%)Rejected-AOC GARUBANDHA MISSAMARI DIST SONITPUR ASSAM 784506 | SONITPUR | ASSAM | 784506 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹56.7 L+₹11.7 L (26.0%)Rejected-AOC | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹56.7 L+₹11.7 L (26.1%)Rejected-AOC | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹58.0 L+₹13.0 L (29.0%)Rejected-AOC | L5 | Rejected-AOC REJECTED |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
19 Oct 2020, 6:00 pmClosed
GE(NW)BHNADUP
GE(NW)BHNADUP,MUMBAI
REPAIR/REPLACEMENT TO JOINERY, FLOORING, SANITATION AREA, ROLLING SHUTTERS, ATT, WPT, REHABILITATION OF DISTRESSED CONCRETE MEMBERS AND OTHER CONNECTED ITEMS AT NCHC ZONE B POWAI , ULHASNAGAR UNDER GE (NW) BHANDUP
2020_MES_373063_2
8853/B
Open Tender
Civil Works
Item Rate
274 days
POWAI
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE(NW)BHNADUP
₹90,000
28 Jan 2021
23 Sept 2020
22 Oct 2020
23 Sept 2020
19 Oct 2020
7 Oct 2020
24 Sept 2020 - 30 Sept 2020
Amount
M&L for post construction anti- termite traetment along the wall below concreate or masonary apron using chemical emulsion @2.25 liters per linear meter including drilling and plugging holes with cement morter 1:2 to match the existng floor etc complete all as specified and directed.
M & L for post construction anti - termit treatment at points of contract of wood work using chemical emulision (in oil or kerosin based solution ) @ 0.5 liters per holy by drilling 6 mm dia holes at a down ward angles of 45 degree at 150 mm centere to center and sealing the same with white cement and making good to the existing surfaces etc complete all as specified and directed.
M&L for injecting chemical GLYPHOSPHATE 41% SL 20 ml or till refusal by making cuty/injection of the stem of plant 30 mm C/C and spraying with solution (25 ml GLYPHOSPHATE 41% diluted with 1 ltr of water) and removing the plant/vegitation including penetrated roots complete including necesary scaffolding etc all as specified and directed for plants/vegetation
Taking down shutters of any description, exceeding 1.0 Sqm and n exc 2 sqm each complete all as specified and directed.
Taking down chowkat or frame with shutter (without taking off shutter from the frames) not exceeding 1.5 Sqm each complete as specified and directed.
Taking down chowkat or frame with shutter (without taking off shutter from the frames), exc 1.50 sqm but not exc 4.0 sqm each complete as directed
Taking down and refixing in the other opening shutters of any description exceeding 1 Sq.m but not exceeding 2 Sq.m each complete all as specified and directed.
M&L for IInd class Hard wood plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joint complete all as specified and directed.
S & F 2nd class hardwood, glazed and skelton shutter, 35mm thick, open rebated and prepared to receive glass, gauze etc, divided into square with plain, chamfered or rounded mitered and rebated sash bars, edges of framing plane, chamfered or rounded, fitted with cut and mitered bead for securing glass, gauze etc, size of member of shutters as specified in SSR Part -I, section 8, class 8.24(a) (Door shutter), supplied and fitted to chowkats all as specified and directed.
S & F, IInd class hardwood 35mm thick Plain, framed,panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed.
M&L , in repairs, IInd class Hard wood plain fillets squares, rectangular or triangular in section, wrought, secured with screws, sectional area exc 13 Sqcm and not exc 25 Sqcm complete all as specified and directed.
M&L for 19mm thick block boards, grade - I quality, exterior grade, decorative type with decorative face veneer on both sides with external teak wood lipping, 6mm thick alround fixed with screws to timber frame work for cuboard self or shutters etc, complete all as specified and directed..
S&F for Solid PVC door frame of size 50mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying & fixing in opening as per spcification & drawing etc, complete all as specified and as directed.
S&F for Factory made solid PVC Moulded door shutter , 28 to 30 mm thick (stiles), with 2,4 or 6 raised panel design with 2mm th. Moulded PVC sheet on the front face & 2mm plain coour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing with wood free EPS etc, complete all as specified and as directed.
S&F standard aluminum section powder coated in partition / frame and door shutter, sliding windows / ventilators and places otherwise not specified cut to size, jointed with cadmium plated steel screws, including rubber beading or gaskets for fixing glass or wire cloth or Bakelite sheet and all necessary fittings, hinges, screws, plugs, locking arrangements for windows, Nylon ball bearing etc completed all as specified and directed (Aluminum section shall be of make Jindal / Hindalco / Indalco). Note :- Weight of Aluminum sections for frames and shutters shall be only considered for payment. Cost of other consumables required for the item shall be deemed to be included in the quoted rate. However glass panes / Bakelite sheet / wire cloth / mortice lock / locking stay / floor spring / floor door stopper only will be measured and paid separately under respective items as supply only. Fixing by element of these items shall be deemed to be included in quoted rate.
S&F aluminum anodised grill DG- 202 ( 10 mm x 5.2mm ) of Deco grill or equivalent fixed with 'F' section size not less than 20.60 x 15.20 x 1.5mm thick of approved make all as specified and directed. Note : (i) Make shall be of M/s Decogrille of M/s Associated Groups or equivalent as approved by the GE. (ii) Minimum thickness of anodizing shall be 15 microns.
Supply only 4mm thick sheet figured glass, pin head type and glazing with oil putty in square not exceeding 0.5 Sqm in each pane etc complete all as specified and directed
Supply only 4.80mm thick ordinary quality plain not exc 0.5 Sqm each pane with including wooden/rubber beading or gasket for aluminium section complete all as specified.
Supply only 4.80 mm thick glass ordinary quality in plain exc 0.50 Sqm each pane including rubber beading or gasket for aluminium section complete all as specified. complete all as specified.
Supply only for 6mm thick bakelite sheet prelaminated both side with decorative choice laminations with aluminium frame cuboard shutter work complete all as specified and directed.
Supply only stainless steel wire cloth of 0.36 mm nominal dia of wire and average width of aperture 1.40 mm , fixed in aluminium windows complete all as specified and directed.
S &F, in repairs, aluminium alloy wire cloth, 0.45 mm nominal dia of wire and average width of aperture 1.40mm and fixed with in wooden windows, doors etc,and fixing of teak wooden beeding complete all as specified and as directed by the Engineer in charge.
Supply and fix aluminium alloy anodised sliding door bolt with hasp and staple(bolt type) and fixing clips of sheet, cast or extruded section and fixing bolt and sliding bolt of extruded section of size 250 mm fixed at any position all as specified and directed.
S&F in stainless steel butt hinges, 100mm, medium weight complete all as specified and directed
S&F in extruded aluminium alloy handles, fabricated type of size 150mm in any position complete all as specified and directed.
S&F in aluminium, anodised, barrel tower bolts of extruded section of size 150mm complete all as specified and directed.
S&F in repair for 20mm dia aluminium coated curtain rods complete all as specified and directed
Dismantling stone slabs and tiles of any description or thickness in staircase cement stone slab and similar work laid, bedded and pointed in cement mortar and removing debris outside MD land complete all as specified and directed.
Demolition of brick work or stone boulder masonry,built in cement mortar or cement lime mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stone work and precast concrete articles.complete all as specifed and directed
M&L for brick work with sub class B old size bricks and of class designation 35 (Minimum compressive strength 35 Kg/Sqcm) , straight or curved on plan exc. 6metre mean radius, built in cement mortar 1:6, complete all as specified and directed.
S&F machine cut and machine polished, green marble, 18-20mm thick on horizontal or vertical surface,as in window cills and jambs bedded, jointed and pointed with neat grey cement slurry and pointed with coloured or white cement with pigment to match over and including rendering coat of 10 mm thick in CM 1:4 all as specified and directed.
M&L for 18-20mm thick granite(of any type) work table rubbed and polished as in jambs, pillars, door and windows-cill, cooking platform , jambs, wash basin platform and the like in cement mortar (1:4) including pointing in white / coloured cement (1:2) using marble dust with admixture of pigment to match with shade of granite including cutting of oval shape for fixing of counter wash hand basin etc over and including 10mm thick rendering / screed in CM 1:4 on fair faces of brick/concrete surfaces complete all as specified and directed.
Demolition of concrete in ground floors (un re-inforced) and paving n.exc. 15 cm thickness (below or above ground level) and removal of rubbish/ demolished materials out of MD land complete all as specified and directed.
M&L providing cement concrete type B0, 1:2:4 (12.5mm graded aggregate) 30mm thick as in flooring all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises etc out side MD land complete all as specified and directed.
M&L for glazed ceramic coloured tiles 350x250x7mm / 450x350x7mm thick in vertical surfaces such as skirting/dado and jointed in neat cement slurry and pointed in white or coloured cement to match and including over 10mm thick rendering in CM 1:4 on fair faces of brick/concrete surfaces as in backing coat for tiles. etc, all as specified and directed.
M/L for Non-skid ceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.18 sqm n exc 0.36 sqm in floors etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 15mm thick screed bed in CM 1:6 laying floor finished complete all as specified and directed.
M/L for Non-skid ceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.18 sqm n exc 0.36 sqm in vertical surfaces such as skirtings, dados etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match including over 10mm thick rendering in CM 1:4 on fair faces of brick/concrete surfaces as in backing coat for tiles.complete all as specified and directed.
M&L for glazed ceramic coloured tiles 300x200mmx7mm thick in vertical surfaces such as skirting/dado and risers to steps and including over 10mm thick rendering in CM 1:3 on fair faces of brick/concrete surfaces as in backing coat for tiles. etc, all as specified and directed.
M&L for Non-skid ceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.06 sqm n exc 0.11 sqm in floors etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:4 laying floor finished complete all as specified and directed.
M&L for vertified ceramic tiles 10mm (light shade of square/ rectangular) polished, area of each tiles not exc 0.36 sqm in floors etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6 laying floor finishesed complete all as specified and directed.
M&L for vertified ceramic tiles 10mm (light shade of square/ rectangular) polished, area of each tiles not exc 0.36 sqm in walls skirting etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match including over 10mm thick rendering in CM 1:4 on fair faces of brick/concrete surfaces as in backing coat for tiles.complete all as specified and directed.
S&F stainles steel sink with drainage board , 1 mm thick sheet of steel grade AISI 304 for kitchen or laboratory, with plug, waste pipe, washers including CI cantilever bracket, connecting union etc., overall size 915 x 460 mm with bowl size 410 mm x 330 mm x 160 mm including supply and fixing bib tap CP with long body screwed for iron pipe complete all as specified and directed. Make : Nirali, Bule star ISI marked.
S&F in repair PVC cabinet mirror of size 600X450 mm complete all as specfied and directed. Make: poly tuf or Prayag polymers pvt ltd complete all as specified and directed.
S&F for 20mm dia fancy type chromium plated curtain rods with fixing fancy brackets, brass screws etc complete all as specified and directed
S&Fin repair plastic water closet seat cover as per reqd colour with flat bottom and cover and mild steel chromium plated or aluminium hinging device etc complete all as specified and directed..
S&F in repair brass chromium plated towel rail 20mm dia 'D' type 600mm long between flanges, of with and including chromium plated brass screws etc complete all as specified and directed. Make:Prayag polymers Pvt Ltd or equivalent
S&Fin repair wash down water closet (pedestal pattern) white and including plastic water closet seat cover as per reqd colour with flat bottom and seat cover and mild steel chromium plated or aluminium hinging device (excluding flushing cistern ) etc complete all as specified and directed..
S&F in repairs vitreous china squatting pan, white, orissa pattern pan of size 580 mm x 440 mm of standard quality with integral foot rests,and including 'P' trap or 'S' Trap complete including connection to trap and to flushing pipe, anti syphonic pipe etc., complete all as specifiedand directed.
S&F in repairs wash hand basin, vitreous china white of size 550x 400mm excluding taps, waste chain and plug and porcelain stopper but including brackets,32mm waste fitting and waste pipe of 32 mm bore, brass, chromium plated for glazed ware wash basin and 15mm dia pillar taps chromium plated fancy type etc complete all as specified and directed.
Supply and fix in repair 10 ltr, PVC, valveless, syphonic action type, flushing cistern, low level/ high level including inlet, ball valve, float and handle including brackets with and including PVC flush pipe 32 mm bore, connecting to WC etc, complete all as specified and directed.
S&F for CP concealed stop cock 15mm bore fancy type chromium plated.with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repairs CP angle cock 15mm bore fancy type chromium plated.with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repair Health faucet with 1 mtr tube & hook cat No BEA-40 of Prayag polymers pvt ltd or equivalent complete all as specified and directed.
S&F in repairs CP bib tap 15mm bore fancy type with crutch or butterfly handle, screwed for iron pipe or for unions and fixed complete all as specified and directed.
S/F in repairs brass Chromium plated wall mixer for mixing hot and cold water screwed down for iron pipe and fixed 15mm bore fancy type. Make -Jaqur,Prayag polymers Pvt Ltd or equivalent.
S/Fin repair 15mm size PVC connection with PTMT nuts 450mm length.complete all as specified and directed.
S&F in repair stainless steel grating in ground shape 100mm dia complete all as specified and directed.
All as per item Sl No 58 above but with hole complete all as specified and directed.
S & F in repair 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall complete all as specified and directed.
S & F in repair 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall complete all as specified and directed.
S & F 75 mm bore PVC (SWR) bends of any radius complete all as specified & directed.
S&F in 110 mm bore PVC (SWR) tee of any radius complete all as specified & directed.
S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified & directed.
S&F PVC (SWR) junction, double equal or unequal 110mm dia fixed in repairs.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 15mm complete all as specified and directed.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 20mm complete all as specified and directed.
S&F 15mm bore U- PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc. with all fittings completed all as specifiec and directed.
All as per item Sl No 69 above but 20 mm bore.
S&F in repairs 2000 ltrs Rotational moulded polyethylene water storage tanks (cylinderical vertical with closed top) hoisted and fixed in position all as specified in ssr part-I complete all as specified and as directed.
Dismantling of roof terracing cement / brick concrete (un-reinforced) and existing water proofing treatment of any thickness in any position and of any portion from top of roof of building, cleaning surface of roof with wire brush / mechanical brush and with water thoroughly to remove all dust / dirt and loose particles to expose base concrete roof slab and removal of rubbish / demolished material out of MD land complete all as specified.
M&L for PCC 1:2:4 Type B0 using 12.5 mm graded aggregate with 2% by weight of cement or as per manufacturer's instructions water proofing as in levelling course, haunching, coping and similar works over RCC roof surface and RCC over head tank top surface including rounded or chamferred on edges and formwork etc all as specified and directed.
M&L for preparation of surfaces and applying oil bound bitumin primer over the roof surfaces @ 0.40 lit per sqm confirming to IS code , manufactrured by the same agency as that of Mineral top APP with density of 0.87-0.89 KG/ lit at 25 degree C prepared dry roof surfaces for filling the voids and to receive water proofing membrane of weight not less than 3.6 Kg per sqm grit finish on roof slab and without grit finish on parapet wall and mumty portion reinforced with non wooven polyester matt all as per manufacturer's instructions and zonal specification and as directed by Engr-in-Charge.
M&L for solar reflective bituminous aluminium paint @ 0.10 Kg per Sqm over membrane surfaces as in roof treatment complete all as specified
M&L for 20mm thick screed bed in CM 1:4 mixed with water proofing compound as per manufacturer's instructions over Non woven Geo textile layer to ensure no puncture of APP membrane over polymeric membrane surface etc as specified and directed by Engineer-in-Charge. (Note : Supply of water proofing compound will be measured and paid separately)
M&L for laying 300 mm x 300 mm x 20 mm thick PCC tiles (Hydraulically pressed) with grey cement, set, jointed, cut and polished. The joints shall be grouted and immediately after gouting, the joints shall be pointed flush in in CM 1:3 mixed with water proofing compound as per manufacturers instructions etc all as specified and directed. (Note : Supply of water proofing compound will be measured and paid separately)
M&L for dismantling asbestos cement (corrugated micorrugatedetc.) sheet in roof covering/ fibre sheets etc complete all as specified and directed.
S&F pre-coloured corrugated galvalume (55% aluminium + 43.5% Zinc+ 1.5% Silicon) steel sheets as in roofing/wall cladding, 0.50mm thick (Total coated thickness), 0.45 mm ( base metal thickness )conforming to AS-1397/ASTM A-792 and having yield strength minimum 550 MPA fixed with hot dip galvanised, self drilling and self tapping screws neoprene and EPDM washers and fixed as per manufacturers instructions complete all as specified and directed.
S&F pre-coloured plain galvalume (55% aluminium + 43.5% Zinc+ 1.5% Silicon) steel sheets, 0.50mm thick (Total coated thickness), 0.45 mm ( base metal thickness ) conforming to AS-1397/ASTM A-792 and having yield strength minimum 550 MPA fixed with hot dip galvanised, self drilling and self tapping screws neoprene and EPDM washers and fixed as per manufacturers instructions complete all as specified and directed.
Dismantling of MS works of any description such as ,ladders,gates work,grating etc, including necessary straightening of bends complete all as specified and directed.
S&F Mild steel work of Framed work such as for portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 including welding, complete all as specified and directed.
S & F MS steel work in tubular/roof trusses (framed),purlines,rafters,brackets,wind tiles including distance pieces clates,crane gantries, rails and fastenings and heavy bracket framing, etc (beam,tee,angle,channel or flat sections and circular sections in columns) etc., complete including nessary cutting, welding,fabrication and eraction Machine hydraulic bending , confirming toFe 410 - W (Gde E-250) quality-A. complete, complete all as specified and directed.
Taking down cement or cement lime plaster of any description on brick or stone wall and ceiling surface including raking out joints, hacking for key, scrubbing down with water etc and disposing off the rubbish outside MD land complete all as specified and directed.
M & L for rendering 12 mm thick in CM 1:6 on brick walls or concrete surfaces and finishing the surfaces even and smooth with sagol finish complete all as specified and directed.
M & L for rendering 5 mm thick in CM 1:3 on concrete surfaces as in ceiling and finishing the surfaces even and smooth with sagol finish complete all as specified and directed.
M/L for 15mm thick rendering in CM 1:4 on surface of wall mixed with water proofing compound and shall be scored to provide key for rough finishing coat. including necessary scaffoldings etc complete all as specified and directed Note:- WPC shall be measured and paid seperately.
Supply only integral water proofing compound.
M&L for filling cracks with polymer based chemical (Dr fixit cracks shrink free or equivalent) for cracks not exc 10 mm in width as per manufacturer instruction on wall surfaces on concrete or masonary including scaffolding etc complete all as specified and directed.
M&L for Preparation of old decorated surfaces of wall and applying two coats of Dr fixit rain coat( of Shade/colour as directed by E-in-C) over one coat of Dr fixit prime seal primer all as per manufacturer instruction including necessary scaffoldings etc complete all as specified and directed by Engr- in charge
M&L for Preparation of new Plastered surfaces of wall and applying two coats of Dr fixit rain coat over( of Shade/colour as directed by E-in-C) one coat of Dr fixit prime seal primer all as per manufacturer instruction including necessary scaffoldings etc complete all as specified and directed by Engr- in charge
M&L for preparation of new plastered surfaces on walls, chajjas,filling of hair line cracks with white cement and applying two coats of 100% anti fungal weather resistant acrylic paint over a coat of acrylic primer in approved shade and as per manufacturer's instructions including necessary scaffolding complete all as specified and as directed.
M&L for preparation of new plastered surfaces of wall and two coats of oil bound distemper over a coat of average 1mm thick Birla putty complete all as specified and directed
M&L for preparation of new plastered surfaces of wall and applying three coats of white wash complete all as specified and directed
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed
M & L for applying two coats of synthetic enamel paint over a coat of pink primer including preparation of new wooden surface of any discription not otherwise discribed over 10 cm width or girth, complete all as specified and directed.
M&L for preparation of old decorated surfaces of ceiling brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots and thereafter applying one coat of white wash complete all as specified and directed.
M&L for preparation of old decorated surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots and thereafter applying with roller one coat of oil bound distemper including application of putty for smooth finish.etc complete all as specified and directed.
M&L for preparation of old wooden surfaces of any description, not other wise described, over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old decorated surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and thereafter applying with roller Two coat of oil bound distemper including application of wall care putty for smooth finish.etc complete all as specified and directed.
M&L for preparation of old acrylic surfaces of walls/ceiling including brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots, washing down with water, filling of cracks with Dr fixit crack filler or equivalent make and applying one coat of 100% antifungal acrylic paint of approved shade including necessary scaffolding work etc complete all as specified and directed.
Taking down carefully copper/alumunium point wiring for light, fan, bell, socket or power complete including fittings such as switches, ceiling roses pendents regulators, sockets, Tube lights etc, removing materials from site and serviceable material re-use at site and making good distrubed surface of wall, floors etc all as specified and directed.
Material and labour for point wiring complete with 1.5 sqmm PVC insulated unsheathed 1100 volts grade FRLS cable multistranded copper conductor single core in casing caping of suitable size complete with sunken iron pressed steel terminal box 2 mm thick for fitting mounting switch/ sockets regulators etc with hylam sheet 3 mm thick cover and with 1.5 sqmm PVC insulated copper conductor earth wire and connected to common earth dolly for the following points all as specified and directed. Make of wire- Polycab/Havells/Finolex (a) One light point controlled by one switch
(b) One fan/exhaust fan point controlled by one way switch
(c) One 5A 2pin/3pin socket on same board.
(d) One bell point controlled by one switch
(e) One 3 pin socket point 5A controlled by switch on independent board
All as per item Sl No 103 above but for 3 pin socket outlet 15 Amp independent with cable 2.5 sqmm unsheathed stranded 1100 Volts grade complete with 1.5 sqmm PVC insulated earth wire and connecting to earth dolly all as specified and directed.
S&F switch piano type 5 Amp single pole one way complete all as specified and directed.
Supply only switch piano type 5/6 Amp single pole one way complete all as specified and directed.
S&F ceiling rose surface backelite, three terminal complete all as specified and directed.
S&F bell push 5 Amp piano type single pole 230 volts one way complete all as specified and directed.
S&F call bell buzzer AC, 230 Volts single pole all as specified and directed.
M&L for socket outlet 2 in 1 3 pin 5 Amps & 2 pin 5 Amps multipurpose flush type.
S&F switch socket combination multi purpose 5 pin 5 Amp flush type complete all as specified and directed.
Supply only switch socket combination multi purpose 5 pin 5 Amp flush type complete all as specified and directed.
S&F switch socket combination multipurpose 3 pin 15 Amp and 3 pin 5 amp flush type 2 in 1 complete all as specified and directed.
Supply only switch socket combination multipurpose 3 pin 15 Amp and 3 pin 5 amp flush type 2 in 1 complete all as specified and directed.
S&F in repair ceiling fan regulator step type 230V, all as specified and directed
S&F in repair ceiling fan regulator socket type 230V, all as specified and directed.
Fixing only ceiling fan regulator, 230V, retrived item Ser No 1 all as specified and directed.
S&F in repairs of LED indoor decorative aluminium extruded T5 lED batted integrated type tube light fitting, suitable and including 1x22W, 230V, bipin holders, connector block etc complete with all accessories internally prewired and including connected up with twin core twisted flexible copper conductor cable with suitable sizes all as specified and directed. Make :- Philips BN021C LED22S PSU CW GR/Havells
S&F in repairs of LED indoor decorative aluminium extruded T5 lED batted integrated type tube light fitting, suitable and including 1x12W, 230V, bipin holders, connector block etc complete with all accessories internally prewired and including connected up with twin core twisted flexible copper conductor cable with suitable sizes all as specified and directed Make:-Philips BN021 LED12S PSU CW GR Havells
Supply and fixing in repairs of LED tube light of 18/20 watt T8 retrofit type complete all as specified and directed Make: Philips/Wipro/Havells
S&F in repairs of LED bulb 230V, holder type 7/9 watt complete Make: C&S cat no LTHPLEDLAMP7W/B22 or equivalent in Bajaj/Halonix
S&F in repairs of angular batten holder PVC / poly carbonite body and brass internal parts with back plate mounted on PVC square box complete
Taking down main switches DBs with sheet metal enclosure 2/4/6/8 way SPN/TPN/DBs etc all as specified and directed.
S&F MCB DB SPN 08 way double door, 240 Volts with 200 rated bus bar complete all as specified.
S&F MCB DB SPN 04 way double door, 240 Volts with 200 rated bus bar complete all as specified.
S&F MCB DB SPN 02 way, 240 Volts complete all as specified.
S&F MCB DB TPN 04 way double door, 415 Volts with suitable bus bar complete all as specified.
S&F MCB DB TPN 06 way double door with sutitable bus bar complete all as specified.
S&F in repairs of MCB SP 240 Volts 6 to 32 Amps complete all as specified and directed.
S&F in repairs of MCB SPN 240 Volts 6 Amp to 32 Amp complete all as specified.
S&F in repairs of MCB TPN 440 Volts 63 Amp complete all as specified.
S&F in repairs of MCB TPN 440 Volts 40 Amp complete all as specified.
Taking down and opening / dismantling of ceiling fan, cleaning complete, oiling / greasing including replacement of capacitor/worn out parts e.g. bearing, bush, shaft, etc.where necessary, checking for smooth running including painting with one coats of synthetic enamel paint cleaning and preparing the surface and refixing, testing and commissioning complete all as specified and directed by Engineer-in-Charge. Note : Spare parts like capacitor, bush and bearing will be measured and paid separately under respective items.
Taking down and opening / dismantling of ceiling fan, 1200/1400 mm sweep and taking out old unserviceable winding and M & L for rewinding the same with super enamelled copper wire of existing/same gauge including all insulating material required as per standard practice, varnishing the same and drying, cleaning the fan bearing/bushing and greasing/oiling and reassebling, testing complete including spy painting with one coats of synthetic enamel paint after preparing rusted surface and refixing, testing and commissioning complete all as specified and directed by the Engineer-in-Charge. Note : 1) Spare parts like capacitor, bush and bearing will be measured and paid separately under respective items. 2) winding fan warrenty will be one year.
Taking down and opening / dismantling of exhaust fan, 250/300 mm sweep and taking out old unserviceable winding and M & L for rewinding the same with super enamelled copper wire of existing/same gauge including all insulating material required as per standard practice, varnishing the same and drying, cleaning the fan bearing/bushing and greasing/oiling and reassebling, testing complete including spy painting with one coats of synthetic enamel paint after preparing rusted surface and refixing, testing and commissioning complete all as specified and directed by the Engineer-in-Charge. Note : 1) Spare parts like capacitor, bush and bearing will be measured and paid separately under respective items. 2) winding fan warrenty will be one year.
Taking down and opening / dismantling of exhaust fan 450 mm sweep and taking out old unserviceable winding and M & L for rewinding the same with super enamelled copper wire of existing/same gauge including all insulating material required as per standard practice, varnishing the same and drying, cleaning the fan bearing/bushing and greasing/oiling and reassebling, testing complete including spy painting with one coats of synthetic enamel paint after preparing rusted surface and refixing, testing and commissioning complete all as specified and directed by the Engineer-in-Charge. Note : 1) Spare parts like capacitor, bush and bearing will be measured and paid separately under respective items. 2) winding fan warrenty will be one year.
Supply only bearing Suitable for existing ceiling fan of 1200/1400mm sweep all as specified and directed
Supply only bush Suitable for existing ceiling fan 1200/1400mm sweep all as specified and directed
Supply only capacitor 2.5/3 mfd capacity 230 volts all as specified and directed
Material and labour in repair of submain wiring complete with two core 04 sqmm (nominal core) PVC insulated unsheathed 1100 volts grade FRLS cable multi stranded copper conductor single core in PVC conduit/Casing capping of suitable size complete with one core of 04 sqmm PVC insulated unsheathed, FRLS green colour copper conductor as earth wire connecting to earth dolly. Note :-02 run of 4 sqmm and 01 run of 4 sqmm wire and one run of PVC conduit/casing capping shall be measured as one Running Meter length)
Material and labour in repair of submain wiring complete with two core 2.5 sqmm (nominal core) PVC insulated unsheathed 1100 volts grade FRLS cable multi stranded copper conductor single core in PVC conduit/Casing capping of suitable size complete with one core of 2.5 sqmm PVC insulated unsheathed, FRLS green colour copper conductor as earth wire connecting to earth dolly. Note :-02 run of 2.5 sqmm and 01 run of 2.5 sqmm wire and one run of PVC conduit/casing capping shall be measured as one Running Meter length)
Supply ands fix in repairs electronic type static watt hour energy meter tamper proof made out of polycarbonate casing of class I accuracy confirming to IS 12779 and suitable for LT single phase 02 wire AC 230 volts, 50 Hz, 5-30 Amps with fully tamper proof low consumption LED display backlite LTRTC optical communication port with facility storage of data and for downloading of data (measures & display KWH, V, I, KW, PF, last month history of KWH & MD in KW) and including dismantling of existing unseviceable energy meter and deposited to MES store yard. Make : Schneider/Secure/HPL (b). The meter shall display in absence of power supply Note :- Old electric meter shall be deposited in E/M store yard on own contractor cost.
M & L in replacement of Earthing complete with galvanised steel earth electrode 60Cm x 60Cm x 6 mm thick directly burried in ground ( eath pit not less than 2.25 M deep below the normal ground level conneceted to galvanised earth lead wire 4 mm dia by mens of bolts, nuts, check nuts and washers of galvanised iron steel including necessery excavation earth work PCC chamber CI chamber cover protection pipe watering pipe etc. (Complete all as shown in electrical plate No 3 and conected to earthing test point complete including excavation earthwork, PCC chamber, chamber cover ,funnel watering and protection pipe etc all specified and directed.
Refixing of Switch 5/15 A retrived item ser No -1all as specified and directed
Refixing of seviceable Tube lights retrived item ser No -1 all as specified and directed
S&F in repair PVC Casing capping/conduit of size 20/25 mm complete all as specified and directed. Make- Sintex/ Plasto plus/Precison
Supply only LED indoor decorative aluminium extruded T5 lED batted integrated type tube light fitting, suitable and including 1x12W, 230V, bipin holders, connector block etc complete with all accessories internally prewired and including connected up with twin core twisted flexible copper conductor cable with suitable sizes all as specified and directed Make:-Philips BN021 LED12S PSU CW GR Havells
Supply only LED indoor decorative aluminium extruded T5 lED batted integrated type tube light fitting, suitable and including 1x22W, 230V, bipin holders, connector block etc complete with all accessories internally prewired and including connected up with twin core twisted flexible copper conductor cable with suitable sizes all as specified and directed. Make :- Philips BN021C LED22S PSU CW GR/Havells Note :- (a) The contractor will be alloted complaint on daily basis and sufficient resources will be deployed by him/her for completion of day to day complaint within 24 Hrs from the time of reporting. Any delay beyond above mentioned time limit suitable penelities as mentioned inrelavant clause of contract (b) A detailed log of complaints with completion/non-completion remarks from user/MES will be maintained by the contractor and same will be updated on daily basis in consulation with Engr-in-charge or JE detailed by him (c) The contractor will make suitable arrangement for emergent complaints and will notify auth rep/Engr-in-charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond state time limit set for disposal of complaint. In case of any dispute the decision of accepting officer will be final and binding in this regard (d) The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints. (e) The quoted rated deems to be inclusive of transporation and expenses required for the resource deployment at the complaint (f) The contractor will maintain suitable inventories and range of spares required to meet the complaints as same will be reviewed peridically by Engr-in-charge to steamline complaints disposal system.
M/S Sun Enterprises
GRAND SERVICES
GAHARWAR BUILDERS
S R INFRASTRUCTURE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .