Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.4 LAccepted-AOC WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | L1 | Accepted-AOC Accepted Being L1 | |
| 2 | L2₹33.6 L+₹3.5 L (11.6%)Rejected-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | L2 | Rejected-Finance Rejected being not Lowest | |
| 3 | L3₹34.2 L+₹4.1 L (13.6%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | L3 | Rejected-Finance Rejected being not Lowest | |
| 4 | L4₹36.4 L+₹6.2 L (20.6%)Rejected-Finance | L4 | Rejected-Finance Rejected being not Lowest | |
| 5 | L5₹40.0 L+₹9.9 L (32.7%)Rejected-Finance 10 WARD NO 18 PLOT NO 34 KAMDENU FURNTIURE SIKAR RAJASTHAN 332025 | SIKAR | RAJASTHAN | 332025 | L5 | Rejected-Finance Rejected being not Lowest |
| Sl No | Description | Qty | Unit | DS CONSTRUCTION L9 | MV Engineers And Contractors L6 | mayur enterprises L1 | Commercial Traders L7 | Vijay Electricals L3 | ALLIED CONSTRUCTION L4 | KISHORE ENTERPRISES L8 | M P TYAGI ENGINEERS AND CONTRACTORS L2 | Ruchi enterprises L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Decarbunizing/cleaning complete outgoing/Incoming LT Air Circuit Breaker circuit of size 800/1000/1200 Amps ,srpring, arcing surfaces, 3 phase, cleaning with CTC and ensure proper decarburizing, re-fixing the same tightening the nuts, bolts thimbles for incoming and outgoing system complete, as specified and directed, rate quoted is inclusive of spring & cotton waste provided by contractor complete all as directed and specified by Engr-in- charge. | 10 | Each Job | 2,000 ₹20,000 | 2,200 ₹22,000 | 1,000 ₹10,000 | 1,400 ₹14,000 | 500 ₹5,000 Lowest | 1,000 ₹10,000 | 2,000 ₹20,000 | 999 ₹9,990 | 2,000 ₹20,000 |
| 2.00 | Suuply and Fixing in replacement of UNSV MCCBs of capacity 400 Amps, FP, 50 KA, 415 Volts 50 Hz, AC, with adjustable thermal and magnetic release fixed in any type of existing LT panel/Feeder pillar including taking out old existing unserviceable MCCB from panels etc complete all as directed and specified by Engr-in- charge. | 3 | Each Job | 24,000 ₹72,000 | 12,000 ₹36,000 | 8,000 ₹24,000 | 24,500 ₹73,500 | 14,000 ₹42,000 | 14,000 ₹42,000 | 25,000 ₹75,000 | 7,999 ₹23,997 Lowest | 15,000 ₹45,000 |
| 3.00 | Suuply and Fixing in replacement of UNSV MCCBs of capacity 250 Amps, FP, 50 KA, 415 Volts 50 Hz, AC, with adjustable thermal and magnetic release fixed in any type of existing LT panel/Feeder pillar including taking out old existing unserviceable MCCB from panels etc complete all as directed and specified by Engr-in- charge. | 3 | Each Job | 18,000 ₹54,000 | 7,510 ₹22,530 | 5,000 ₹15,000 Lowest | 15,500 ₹46,500 | 9,000 ₹27,000 | 12,000 ₹36,000 | 18,000 ₹54,000 | 6,999 ₹20,997 | 13,000 ₹39,000 |
| 4.00 | Suuply and Fixing in replacement of UNSV MCCBs of capacity 200 Amps, FP, 50 KA, 415 Volts 50 Hz, AC, with adjustable thermal and magnetic release fixed in any type of existing LT panel/Feeder pillar including taking out old existing unserviceable MCCB from panels etc complete all as directed and specified by Engr-in- charge. | 3 | Each Job | 17,000 ₹51,000 | 6,000 ₹18,000 | 4,500 ₹13,500 Lowest | 14,500 ₹43,500 | 8,000 ₹24,000 | 11,000 ₹33,000 | 14,000 ₹42,000 | 5,999 ₹17,997 | 10,000 ₹30,000 |
| 5.00 | Material and Labour for re-painting of LT Panels/feeder pillars of approx size 2 to 4 Sqm with 2 coats of super enamel paint over a coat of red-oxide with sparygun including writing of feeder pillar numbers in appropriate size of letters as complete all as directed and specified by Engr-in- charge. | 25 | Each Job | 2,000 ₹50,000 | 1,200 ₹30,000 | 1,500 ₹37,500 | 800 ₹20,000 | 1,200 ₹30,000 | 1,800 ₹45,000 | 500 ₹12,500 | 499 ₹12,475 Lowest | 500 ₹12,500 |
| 6.00 | All as per item No 05 above but of approx size upto 1.90 Sqm | 25 | Each Job | 2,000 ₹50,000 | 1,200 ₹30,000 | 1,500 ₹37,500 | 800 ₹20,000 | 1,200 ₹30,000 | 2,000 ₹50,000 | 400 ₹10,000 Lowest | 499 ₹12,475 | 500 ₹12,500 |
| 7.00 | Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 11 KV HT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as directed and specified by Engr-in- charge.
Note: (a) 11 KV HT cable & joints shall be measured and paid for separately under respective items of schedule.
(b) Retrieved old serviceable cable cover will be laid in trenches for cable protection. If extra PCC cover and sand required at site shall be measured and paid separately under respective items of BOQs.
(c) Excavation and earth work will be measured and paid for separately under respective items of schedule.
(d) Taking out faulty underground HT/LT cable of any size from trenches and the rate for the same deemed to be included in quoted rate. | 50 | Each Job | 5,000 ₹2,50,000 | 5,500 ₹2,75,000 | 5,000 ₹2,50,000 | 3,000 ₹1,50,000 | 5,000 ₹2,50,000 | 4,000 ₹2,00,000 | 3,000 ₹1,50,000 | 2,999 ₹1,49,950 Lowest | 3,000 ₹1,50,000 |
| 8.00 | All as per item Ser No 7 here in before but 1100 Volt LT cables | 80 | Each job | 5,000 ₹4,00,000 | 5,000 ₹4,00,000 | 5,000 ₹4,00,000 | 2,000 ₹1,60,000 Lowest | 4,000 ₹3,20,000 | 4,000 ₹3,20,000 | 4,000 ₹3,20,000 | 2,999 ₹2,39,920 | 2,800 ₹2,24,000 |
| 9.00Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armored aluminum conductor cable complete all as directed and specified by Engr-in- charge of following size :- | ||||||||||||
| 9.01 | 95 Sqmm 3 core. | 2 | Each | 2,500 ₹5,000 | 1,990 ₹3,980 | 1,000 ₹2,000 | 200 ₹400 Lowest | 1,500 ₹3,000 | 3,000 ₹6,000 | 1,500 ₹3,000 | 4,999 ₹9,998 | 4,000 ₹8,000 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
4 Aug 2026, 6:00 pmClosed
GE Utility Electric Supply
GE Utility Electric Supply DELHI CANTT-10
REPAIR AND MAINTENANCE OF 11 .415KV DAMAGED CABLE AND ELECTRIC BREAKDOWN INCLUDING FAULT DETECTION LOCALIZATION RECTIFICATION WORKS IN 11 .415 KV UNDERGROUND CABLE NETWORK OVER HEAD LINES AND LT PANELS AT HQ TG EME DIPAC 105 TA CVD OSG PIRU VIHAR BAS
2026_MES_778440_1
GE ELECT/TOKEN-10/2026-2027
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Utility Electric Supply
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE Utility Electric Supply
₹98,000
30 Sept 2026
14 Jul 2026
6 Aug 2026
14 Jul 2026
4 Aug 2026
28 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Decarbunizing/cleaning complete outgoing/Incoming LT Air Circuit Breaker circuit of size 800/1000/1200 Amps ,srpring, arcing surfaces, 3 phase, cleaning with CTC and ensure proper decarburizing, re-fixing the same tightening the nuts, bolts thimbles for incoming and outgoing system complete, as specified and directed, rate quoted is inclusive of spring & cotton waste provided by contractor complete all as directed and specified by Engr-in- charge. | 10 | Each Job | - | - |
| - | Suuply and Fixing in replacement of UNSV MCCBs of capacity 400 Amps, FP, 50 KA, 415 Volts 50 Hz, AC, with adjustable thermal and magnetic release fixed in any type of existing LT panel/Feeder pillar including taking out old existing unserviceable MCCB from panels etc complete all as directed and specified by Engr-in- charge. | 3 | Each Job | 1 | ₹3 |
| - | Suuply and Fixing in replacement of UNSV MCCBs of capacity 250 Amps, FP, 50 KA, 415 Volts 50 Hz, AC, with adjustable thermal and magnetic release fixed in any type of existing LT panel/Feeder pillar including taking out old existing unserviceable MCCB from panels etc complete all as directed and specified by Engr-in- charge. | 3 | Each Job | 2 | ₹6 |
| - | Suuply and Fixing in replacement of UNSV MCCBs of capacity 200 Amps, FP, 50 KA, 415 Volts 50 Hz, AC, with adjustable thermal and magnetic release fixed in any type of existing LT panel/Feeder pillar including taking out old existing unserviceable MCCB from panels etc complete all as directed and specified by Engr-in- charge. | 3 | Each Job | 3 | ₹9 |
| - | Material and Labour for re-painting of LT Panels/feeder pillars of approx size 2 to 4 Sqm with 2 coats of super enamel paint over a coat of red-oxide with sparygun including writing of feeder pillar numbers in appropriate size of letters as complete all as directed and specified by Engr-in- charge. | 25 | Each Job | 4 | ₹100 |
| - | All as per item No 05 above but of approx size upto 1.90 Sqm | 25 | Each Job | 5 | ₹125 |
| - | Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 11 KV HT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as directed and specified by Engr-in- charge.
Note: (a) 11 KV HT cable & joints shall be measured and paid for separately under respective items of schedule.
(b) Retrieved old serviceable cable cover will be laid in trenches for cable protection. If extra PCC cover and sand required at site shall be measured and paid separately under respective items of BOQs.
(c) Excavation and earth work will be measured and paid for separately under respective items of schedule.
(d) Taking out faulty underground HT/LT cable of any size from trenches and the rate for the same deemed to be included in quoted rate. | 50 | Each Job | 6 | ₹300 |
| - | All as per item Ser No 7 here in before but 1100 Volt LT cables | 80 | Each job | 7 | ₹560 |
| - | Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armored aluminum conductor cable complete all as directed and specified by Engr-in- charge of following size :- | - | - | - | - |
| - | 95 Sqmm 3 core. | 2 | Each | 9 | ₹18 |
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
TD10.pdf
Tender Documents • 1.29 MB
BOQ_871868.xls
BOQ • 0.27 MB
AmendNO110.pdf
PDF • 0.87 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .