Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAccepted-AOC 76 VATHAL MARKET NAINAR KULAM ROAD TIRUNELVELI 627006 | TIRUNELVELI | TIRUNELVELI | TAMIL NADU | 627006 | ₹1.7 Cr Quoted ₹1.8 Cr | L1 | Accepted-AOC Accepted |
| 2 | Rejected-Technical | - | - | Rejected-Technical Not eligible in the pre-qualification criteria of technical evaluation. |
Tender Value
₹1.7 Cr
EMD Value
₹94,500
Closing Date
30 Dec 2024, 3:00 pmClosed
Superintending Engineer, North Circle II
New No. 56 Old No. 140, Santhome High Road, Chennai - 600 004.
Design, Manufacture, Supply, Delivery, Installation, Testing and Commissioning of 3 nos of 15 persons capacity stretcher cum passenger lift and 3 nos of 10 persons capacity passenger lift for the work of Reconstruction of 300 tenements at Suberdar Ga
2024_TNUHB_510032_1
TNUHDB/1290-1/D1/SE(NC-II)/19
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
Subedar Garden Scheme Chennai
Please refer Tender documents.
9 documents required · 9 mandatory
₹0
₹94,500
3 Jul 2025
12 Dec 2024
31 Dec 2024
12 Dec 2024
30 Dec 2024
20 Dec 2024
Amount
Design, Engineering, Supply, Fabrication, Erection, Testing, commissioning and handing over of 1 no of 15 passenger stretcher Cum passenger lift as per the following specifications including taxes and duties.(Gearless lift with machine room) 1.Location:Suber Garden Scheme, 2. No of lift: 3 nos. (Gearless), 3. Type of lift: Stretcher Cum passenger lift, 4.Capacity of lift: 15 persons /1020 kg, 5.Speed: 1.0 M / Sec, 6.Type of drive: V3F drive with enhanced ride comfort and near zero level functions, 7.No of floors: S + 6 Floor, 8.Total travel: 3.0 mts x 7 Landing = 21 mts, 9.Leveling accuracy: high level accuracy with smooth and jerk free stopping, 10. Construction of CAR: No. 4 hardened sheet high quality stainless steel car and hand rail granite flooring and Perspex false ceiling, 11. Position of machine: directly above the lift well, 12. No of landing service: One in the front side- 1 no, 13. No. of car entrance: one in the front side only, 14. Car entrance door: power operated automatic V3F drive center opening sliding SS door, 15. Landing entrance door: power operated V3F drive center opening sliding SS door with provision for emergency exit key at all landings, 16.Lift well : As per IS 14665 (part 1) 2000 to be constructed by the original contractor, 17.Lift pit depth: Conforming to 14665 (part 1) 2000, 18. Car inner size - As per IS 14665 (part 1) 2000, Total weight of persons - and Overhead height : conforming to 14665 (part 1)2000, 19. Car clear opening: As per IS 14665 (part 1)2000, 20. Lift machine room size: As per ISI 14665 (part 1) 2000 to be constructed by the building contractor, 21. Power supply: 400 / 440 v three phase 50 Hz AC supply for power and 230 V 50 Hz single phase power supply for light, 22.Control: micro computer (micro processor):based simplex collective control with / without attendant, 23. Car fittings: CFL lighting with 1 no 300 mm sweep cabin fan, 24. Lift well: RCC construction with brick masonry to be constructed by the building contractor, 25. Induction: UP / DOWN digital direction and floor position indicator for all landings in all floors and inside the car, 26.Emergency alarm bell: battery operated bell to be provided with automatic charging device, 27.Emergency light: battery operated light to be provided with automatic charging device, 28.Fire mans switch: to be provided at the GF, 29. Minor builder works: to be provided by the lift contractor.(S&F of bulk head, 5A switch, light point, wiring 2 of 2.5 sqmm at every floor and machine room lighting, 4way/8way/12 way TPN DB, fuses of required capacity) and other requirements, 30. Scaffoldings: to be provided by the lift contractor, 31. Sill angles and facia plates: SS to be provided by the lift contractor, 32. Steel for lift machinery: to be provided by the lift contractor, 33. Servicing and maintenance: free comprehensive servicing and maintenance for one year Guarantee period to be provided by the lift contractor, 34. Automatic rescue device: to facilitate the landing of the nearest floor at the time of power failure this shall consist of suitable battery system with charger inverter under voltage protection system etc. complete with all accessories and single phase preventor specifying to IS norms, 35. Provision for intercom with phone: to be provided by the lift contractor, 36.Lift license: preparation of drawings payment of charges to CEIG and insurance policy for both lift & body if any and obtaining CEIG approval for the lift as per lift act should be done by the lift contractor, 37. Floor position announcer: to be provided by the lift contractor,38.Special features - a) Infra red door sensor with full height screen, b) Full width half height rear panel mirror, c)Tubular SS hand rail in car, d) Stainless steel signal features, e) Vandal proof SS button with SS cover, f) SS door frames for landing doors, g) V3F door operator, h) Call register signal, i) Stainless steel facia plates for car operating panel and landing fixtures, j) Steel ladder for lift machine room, k) On / off switch for fan and light, l) Over load warning indicator with audio announcer, m)Voltage stabilizer for control circuits, n)Braille button and o) Precautionary measures etched in SS plate, 39.Over speed governor phase failure and phase reversal relay alarm bell T guide brackets for car and counter weight rubber padding under the winding unit motor of adequate capacity signal reduction worm gear electromagnetic brake with compression springs car safety gears buffers electro mechanical locks emergency key side supporting angles motor over load protection devices final limit switch main suspension ropes counter weight lifting joist for mounting the machineries, 40. Guarantee: guarantee at least for one year for the material and workman ship of equipments should be offered by the lift contractor, 41. Site testing in accordance with IS 14665 should be carried out at the time of handing over to the user department, 42. Supply operation and maintenance manual and necessary tools for operation and a set of Spare parts required for one year, 43.All the features as per differently abled person Act should be provided and 44.2 hrs.fire retardent landing doors. Stretcher Lift 15 person capacity
Design, Engineering, Supply, Fabrication, Erection, Testing, commissioning and handing over of 1 no of 10 passenger lift as per the following specifications including taxes and duties.(Gearless lift with machine room) 1.Location:Subedar Garden Scheme, 2. No of lift: 3 nos. (Gearless), 3. Type of lift:Passenger Lift, 4.Capacity of lift: 10 persons /1020 kg confirming to IS 14665 (part 1) 2000, 5.Speed: 1.0 M / Sec, 6.Type of drive:V3F drive with enhanced ride comfort and near zero level functions, 7.No of floors: S + 6 Floor, 8.Total travel: 3.0 mts x 7 Landing = 21 mts, 9.Leveling accuracy: high level accuracy with smooth and jerk free stopping, 13. No. of car entrance: one in the front side only, 14. Car entrance door: power operated automatic V3F drive center opening sliding SS door, 15. Landing entrance door: power operated V3F drive center opening sliding SS door with provision for emergency exit key at all landings, 16.Lift well : As per structural design confirming to IS 14665 (part 1) 2000 to be constructed by the original contractor, 17.Lift pit depth: conforming to 14665 (part 1) 2000, 18. Car inner size - As per IS 14665 (part 1) 2000, Total weight of persons and Overhead height: conforming to 14665 (part 1)2000, 19. Car clear opening: 900 mm wide x 2000 mm height as per IS 14665 (part 1)2000, 20. Lift machine room size: as per ISI 14665 (part 1) 2000 to be constructed by the building contractor, 21. Power supply: 400 / 440 v three phase 50 Hz AC supply for power and 230 V 50 Hz single phase power supply for light, 22.Control: micro computer (micro processor):based simplex collective control with / without attendant, 23. Car fittings: CFL lighting with 1 no 300 mm sweep cabin fan, 24. Lift well: RCC construction with brick masonry to be constructed by the building contractor, 25. Induction: UP / DOWN digital direction and floor position indicator for all landings in all floors and inside the car, 26.Emergency alarm bell: battery operated bell to be provided with automatic charging device, 27.Emergency light: battery operated light to be provided with automatic charging device, 28.Fire mans switch: to be provided at the GF, 29. Minor builder works: to be provided by the lift contractor.(S&F of bulk head, 5A switch, light point, wiring 2 of 2.5 sqmm at every floor and machine room lighting, 4way/8way/12 way TPN DB, fuses of required capacity) and other requirements, 30. Scaffoldings: to be provided by the lift contractor, 31. Sill angles and facia plates: SS to be provided by the lift contractor, 32. Steel for lift machinery: to be provided by the lift contractor, 33. Servicing and maintenance: free comprehensive servicing and maintenance for one year Guarantee period to be provided by the lift contractor, 34. Automatic rescue device: to facilitate the landing of the nearest floor at the time of power failure this shall consist of suitable battery system with charger inverter under voltage protection system etc. complete with all accessories and single phase preventor specifying to IS norms, 35. Provision for intercom with phone: to be provided by the lift contractor, 36.Lift license: preparation of drawings payment of charges to CEIG and insurance policy for both lift & body if any and obtaining CEIG approval for the lift as per lift act should be done by the lift contractor, 37. Floor position announcer: to be provided by the lift contractor,38.Special features - a) Infra red door sensor with full height screen, b) Full width half height rear panel mirror, c)Tubular SS hand rail in car, d) Stainless steel signal features, e) Vandal proof SS button with SS cover, f) SS door frames for landing doors, g) V3F door operator, h) Call register signal, i) Stainless steel facia plates for car operating panel and landing fixtures, j) Steel ladder for lift machine room, k) On / off switch for fan and light, l) Over load warning indicator with audio announcer, m)Voltage stabilizer for control circuits, n)Braille button and o) Precautionary measures etched in SS plate, 39.Over speed governor phase failure and phase reversal relay alarm bell T guide brackets for car and counter weight rubber padding under the winding unit motor of adequate capacity signal reduction worm gear electromagnetic brake with compression springs car safety gears buffers electro mechanical locks emergency key side supporting angles motor over load protection devices final limit switch main suspension ropes counter weight lifting joist for mounting the machineries, 40. Guarantee: guarantee at least for one year for the material and workman ship of equipments should be offered by the lift contractor, 41. Site testing in accordance with IS 14665 should be carried out at the time of handing over to the user department, 42. Supply operation and maintenance manual and necessary tools for operation and a set of Spare parts required for one year, 43.All the features as per differently abled person Act should be provided and 44.2 hrs.fire retardent landing doors. 10 Person Capacity Passenger Lift
Earthing arrangements with GI Earth Plate including charcoal and salt with necessary excavation in all soils and to full depth as may be required and masonry work, re-filling the sides of foundation with excavated earth as per the standard specification and etc complete in all respects as directed by the Departmental Officers.
Supply and fixing of 3 1/2 x 50 sq.mm cable of PVC LTUG armoured cable confirming to IS 694 / 1990 etc complete in all respects as directed by the departmental officers.
Supply and run of 25mm X 6mm GI flat down conductor with necessary clamps / supports on wall/ floor/ ground for earth connection etc complete in all respects as directed by the departmental officers.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .