Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹31 L
EMD Value
₹62,000
Closing Date
13 Mar 2020, 6:00 pmClosed
GE I R AND D GIRINAGAR PUNE 411025
GE I R AND D GIRINAGAR PUNE 411025
REPLACEMENT OF DG SET AND PUMP SET WITH ALLIED WORKS AGAINST BER AT VRDE AHMEDNAGAR
2020_MES_325212_1
GE I R AND D GNR TOKEN 66 OF 2019 2020
Open Tender
Civil Works
Works
180 days
GE I R AND D GIRINAGAR PUNE 411025
REPLACEMENT OF DG SET AND PUMP SET WITH ALLIED WORKS AGAINST BER AT VRDE AHMEDNAGAR
6 documents required · 6 mandatory
₹500
GE I R AND D GIRINAGAR PUNE 411025
₹62,000
Yes
20 Mar 2020
14 Feb 2020
14 Mar 2020
14 Feb 2020
13 Mar 2020
28 Feb 2020
14 Feb 2020 - 26 Feb 2020
Amount
Supply, installation, commissioning and testing of silent diesel engine driven Generation set 75 KVA (60 KW at 0.8 PF) capacity 415 volt 3 phase 4 wire, water cooled, with acoustic weather proof enclosure as per CPEB norms and noise level shall not exceed 75db at a distance 1 metre, engine as per IS -10001/10002 and alternator as per IS-13364 including standard control panel as per manufacturer design complete incl PCC plate form of suitable size and height not less than 250 mm from normal ground level and comprises the following components:- (A) Diesel Engine Diesel engine developing 101.3 BHP, 1500 RPM, water cooled engine inclusive of the following standard accessories. MAKE :- Greaves India/Cummins/Kirloskar Electric/Ashok Leyland/CATERPILLAR:- (i) Radiator and Radiator Fan (ii) Fly wheel (iii) Fly wheel housing complete with sarter gear and coupling (iv) Fuel pipes (v) Air Cleaner (vi) Fuel and lubricant oil filter (vii) Fuel pump (viii) Gear driven water pump (ix) Lubricant oil pump (x) Electric starter 12/24 volts DC as per manufacturer design. (xi) Battery chargeing generator (DC) alternator (xii) Industrial silencer (xiii) Lublicant oil cooler (xiv) Multi-meter controller (xv) Water temperature guage, lub oil pressure gauage. (xvi) First fill of Lubrication/engine oil. Note :- Diesel will be supplied by the department for testing of DG Set. (B) Alternator:- Alternator suitable for continuous operation generating 75 KVA (60 KW) at 1500 RPM 415 volts, 0.8 PF (lag), 3 Phase 4 wire system 50Hz system self excited, self regulated with ball bearings confirming to IS-13364. Make : STAMFORD/Jyoti/Crompton/Caterpillar. (d) SOUND-PROOF ACOUSTIC ENCLOSURE : Shall be with natural air circulation without loss of any power for ventilation fan. The enclosure shall be modular in construction with hinge bolted structure to provide easy dismantling and shall be made out of high quality CRCA sheet steel with sufficient accessories for maintenance work, openable and lockable door with air tight rubber gasket, interior lighting arrangement to meet latest emission norms and emergency cut off switch to close/OFF the DG set in case of accident should be provided outside on acoustic enclosure.
Supply, installation, commissioning and testing of silent diesel engine driven Generation set 40 KVA (32 KW at 0.8 PF) capacity 415 volt 3 phase 4 wire, water cooled with acoustic weather proof enclosure as per CPEB norms and noise level shall not exceed 75db at a distance 1 metre, engine as per IS -10001/10002 and alternator as per IS-13364 including standard control panel as per manufacturer design complete incl PCC plate form of suitable size and height not less than 250 mm from normal ground level and comprises the following components:- (A) Diesel Engine Diesel engine developing 58 BHP, 1500 RPM, water cooled engine inclusive of the following standard accessories. MAKE :-Greaves India/Cummins/Kirloskar Electric/Ashok Leyland/CATERPILLAR i) Radiator and Radiator Fan. ii) Fly wheel. iii) Fly wheel housing complete with starter gear and coupling. iv) Fuel pipes. v) Air Cleaner. vi) Fuel and lubricant oil filter. vii) Fuel pump. viii) Gear driven water pump. ix) Lubricant oil pump. x) Electric starter 12/24 volts DC as per manufacturer design. xi) Battery chargeing generator (DC) alternator. xii) Industrial silencer xiii) Lublicant oil cooler. xiv) Multi-meter controller. xv) Water temperature guage, lub oil pressure gauage. xvi) First fill of Lubrication/engine oil. Note :- Diesel will be supplied by the department for testing of DG Set. B) Alternator:- Alternator suitable for continuous operation generating 40 KVA (32 KW) at 1500 RPM 415 volts, 0.8 PF (lag), 3 Phase 4 wire system 50Hz system self excited, self regulated with ball bearings confirming to IS-13364. Make : STAMFORD/Jyoti/Crompton/Caterpillar (d) SOUND-PROOF ACOUSTIC ENCLOSURE : Shall be with natural air circulation without loss of any power for ventilation fan. The enclosure shall be modular in construction with hinge bolted structure to provide easy dismantling and shall be made out of high quality CRCA sheet steel with sufficient accessories for maintenance work, openable and lockable door with air tight rubber gasket, interior lighting arrangement to meet latest emission norms and emergency cut off switch to close/OFF the DG set in case of accident should be provided outside on acoustic enclosure.
Supply, installation, commissioning and testing of silent diesel engine driven Generation set 25 KVA (20 KW at 0.8 PF) capacity 415 volt 3 phase 4 wire, water cooled with acoustic weather proof enclosure as per CPEB norms and noise level shall not exceed 75db at a distance 1 metre, engine as per IS -10001/10002 and alternator as per IS-13364 including AMF panel as per manufacturer design complete incl PCC plate form of suitable size and height not less than 250 mm from normal ground level and comprises the following components:- (A) Diesel Engine Diesel engine developing 34.2 BHP, 1500 RPM, water cooled engine inclusive of the following standard accessories. MAKE :- Greaves India/Cummins/Kirloskar Electric/Ashok Leyland/CATERPILLAR. i) Radiator and Radiator Fan. ii) Fly wheel. iii) Fly wheel housing complete with starter gear and coupling. iv) Fuel pipes. v) Air Cleaner. vi) Fuel and lubricant oil filter. vii) Fuel pump. viii) Gear driven water pump. ix) Lubricant oil pump. x) Electric starter 12/24 volts DC as per manufacturer design. xi) Battery chargeing generator (DC) alternator. xii) Industrial silencer. xiii) Lublicant oil cooler. xiv) Multi-meter controller. xv) Water temperature guage, lub oil pressure gauage. xvi) First fill of Lubrication/engine oil. Note :- Diesel will be supplied by the department for testing of DG Set. B) Alternator:- Alternator suitable for continuous operation generating 25 KVA (20 KW) at 1500 RPM 415 volts, 0.8 PF (lag), 3 Phase 4 wire system 50Hz system self excited, self regulated with ball bearings confirming to IS-13364. Make : STAMFORD/Jyoti/Crompton/Caterpillar. (d) SOUND-PROOF ACOUSTIC ENCLOSURE : Shall be with natural air circulation without loss of any power for ventilation fan. The enclosure shall be modular in construction with hinge bolted structure to provide easy dismantling and shall be made out of high quality CRCA sheet steel with sufficient accessories for maintenance work, openable and lockable door with air tight rubber gasket, interior lighting arrangement to meet latest emission norms and emergency cut off switch to close/OFF the DG set in case of accident should be provided outside on acoustic enclosure.
Supply, installation, testing and commissioning of electric driven monoblock pump set 10 HP, 3 phase, 415 volt, discharge 14 LPS at head not less than 28 mtr complete with necessary accessories and all as specified and directed by Engr-in-charge.
Supply, installation, testing and commissioning of electric driven open type submersible pump set 7.5 HP, 3 phase, 415 volt, discharge 15 LPS at head not less than 24 mtr complete with necessary accessories and all as specified and directed by Engr-in-charge.
Supply, installation, testing and commissioning of centrifugal pump set, IC engine driven, 10 HP, 3 phase, 415 volt, water cooled, discharge head 20 mtr with suitable size of HDPE suction pipe 6 mtr including and duly fitted on four wheel driven trolly of suitable size and capacity, chassis made with MS channel and MS plate/sheet plain or chequered and suitable size of four wheel for bearing load of pump set and easy movement of trolly complete in all respect and all as specified and directed by Engr-in-charge.
Taking down/dismentling of monoblock pump set 10 HP from the pipe line and electric connection and deposited at MES store yard all as specified and as directed.
Taking down/dismantling of submersible pump set 7.5 HP from U/G sump by disconnecting mechanically from the foundation/pipe line etc and deposited at MES store yard all as directed by Engineer-in-charge.
Supply, laying, jointing and testing of under ground electric cable, XLPE sheathed LT 1100 volts, grade, heavy duty, armoured with aluminium multi stranded conductor cross sectional area of cable 50 Sqmm, 3.5 core conforming to IS laid in trenches, under floor, through the roads fixed along wall/pole/GI pipe with proper clamps complete all as specified and as directed.
All as per above item No-8 above but of 25 Sqmm, 4 core.
Supply & Laying 50 mm outside dia double wall corrugated pipe (DWC) of HDPE ISI Marked for enclosing cable below ground / road surface, to a required depth, including suitable size couplers and clamps etc for jointing of pipe all as per site requirement and all as specified and as directed by Engr-in-charge.
Material and labours earthings complete with galvanized steel earth plate electrode 600 mm by 600 mm by 6 mm thick, buried directly in ground (Earth pit not less than 2.25 metres deep below ground level) , surrounded from all direction with charcoal dust and salt in layers, the top edge of the earth plate not less than 1.5 metre below ground level, connected to galvanized iron strip 32×6mm as earthing lead and 40 mm bore GI pipe light grade for protection of GI strip. fixed by means of bolts, nuts and washers of galvanized iron and connected to earth test point and equipment and testing on completion including excavation and earthwork in any type of soil, PCC chamber in 1 :2:4 using 20 mm graded stone aggregate, CI cover, 20 mm GI pipe light grade for watering, funnel, wire mesh complete all as specified and shown on electrical plate No 5 of MES Schedule Part ‘I’( 1991). Note - Cost of GI Strip and GI protection pipe up to 7.5 RM is deemed to be included in the quoted rate.
Mukund Engineers and Contractors
MORESHWAR ELECTRICALS CORPORATION
PURVA ELECTRICALS AND ENGINEERS
BRITE INDUSTRIES
S.k ENTERPRISES
M/S EAGLE ENTERPRISES
Mayur Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .