Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 LAccepted-AOC MEGHA SADAN GAGANNAGAR CURTI PONDA GOA 403401 | PONDA | SOUTH GOA | GOA | 403401 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹14.0 L+₹6.7 L (91.7%)Rejected-Finance H NO 190 S 4 CHODANKAR RESIDENCY NEAR GANPATI TEMPLE CENTRAL HORTA AQUEM BAIXO NAVELIM SALCETE GOA 403707 | SOUTH GOA | GOA | 403707 | L2 | Rejected-Finance Not being L1 |
Tender Value
₹14.8 L
EMD Value
₹29,500
Closing Date
19 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE PANAJI
Garrison Engineer SV Road Panaji Goa 403001
REPAIR REPLACEMENT OF SEWAGE LINE CLEANING OF SEPTIC TANK AND FILTER BEDS AT PONDA UNDER GE PANAJI GOA
2021_MES_476637_1
8901/E8
Open Tender
Civil Works
Item Rate
365 days
GE PANAJI
As per NIT
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER PANAJI
₹29,500
Yes
26 Nov 2021
21 Sept 2021
21 Oct 2021
21 Sept 2021
19 Oct 2021
5 Oct 2021
21 Sept 2021 - 28 Sept 2021
60 days
Amount
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, laying of pipes, well cesspits, manholes, pier holes etc. not exceeding 10 sqm on plan and not exceeding 1.5m in depth and getting out in hard/ dense soil complete all as specified and as directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in hard/ dense soil complete all as specified and as directed.
Removing of excavated surplus spoil not exceeding 50m and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and as directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for such as cover slab of manholes and septic tank etc., reinforcement cut as required to facilitate demolition complete all as specified and as directed.
Material and labour for pre-cast reinforced cement concrete 1:3:6 type C1 (20mm graded crushed stone aggregate) as in cover slabs for manholes in any position and set in cement mortar 1:6 including necessary form work complete all as specified and as directed.
Material and labour for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Material and labour for mild steel TMT bars 6mm to 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Demolition and breaking up 100/110mm dia drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar complete all as specified and as directed.
Demolition and breaking up 150/160mm dia drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar complete all as specified and as directed.
Demolition and breaking up 200/225mm dia drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar complete all as specified and as directed.
Material and labour for concrete bed to drain pipes of 110mm dia in cement concrete 1:4:8 type D2 using 40mm graded crushed stone aggregate including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed.
Material and labour for concrete bed to drain pipes of 150mm dia in cement concrete 1:4:8 type D2 (using 40mm graded crushed stone aggregate) including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed.
Material and labour for concrete bed to drain pipes of 200mm dia in cement concrete 1:4:8 type D2 (using 40mm graded crushed stone aggregate) including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level) complete all as specified and directed.
Demolition of brick work or laterite stone masonry built in cement morter including precast concrete articles complete all as specified and directed.
Material and labour for laterite stone walling of squared rubble, regular coursed well bounded, bedded and solidly hearted built in CM 1:6 complete all as specified and as directed. Note:- The rate considered is for laterite stone only as per section 6 stone masonry para 6.2.4 of SSR 2020 (Part-II)
All as per serial item No 16 here-in-before but except stone (serviceable stone obtained from serial item No 15 to be used) complete all as specified and directed.
Extra over laterite stone walling for hammer dressing to face stone and dressing of face beds and joints, as specified, of squared rubble masonry regular coursed, hammer dressing with maximum depression on face from straight edge held against the dressed surface not exceeding 20mm complete all as specified and directed.
Material and labour for rendering 15mm thick in cement mortar 1:4 on laterite stone walling surfaces, finished even and fair without using extra cement etc complete all as specified and as directed.
Taking down PVC (SWR) pipes 75/110 mm from walls complete all as specified and as directed.
Supply and fix 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and as directed.
Supply and fix 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and as directed.
Supply and fix UPVC (SWR) branch piece single (single Y) equal or unequal 75 mm bore with access door complete all as specified and as directed.
Supply and fix UPVC (SWR) branch piece double (double Y) equal or unequal 75 mm bore with access door complete all as specified and as directed.
Supply and fix UPVC (SWR) branch piece single (single Y) equal or unequal 110 mm bore with access door complete all as specified and as directed.
Supply and fix UPVC (SWR) branch piece double (double Y) equal or unequal 110 mm bore with access door complete all as specified and as directed.
Taking down cement plaster on brick or stone walls etc including racking out joints hacking for key scrubbing down with water etc
Material and labour for rendering 15mm thick in cement mortar 1:4 on laterite stone walling surfaces, other than fair face finished even and fair without using extra cement and mixed with water proofing compound etc complete all as specified and as directed. Note :- Water proofing compound shall be measured & paid separately.
Material and labour for applying three coats of white (lime) wash including preparation of new plastered or unplastered surfaces of walls complete all as specified and as directed.
Supply only internal water proofing compound complete all as specified and as directed.
Supply and fix in repairs 50mm dia low density polyethylene pipes (LDPE) of pressure rating 6Kg/sqcm laid in tranches including taking down existing pipes complete all as specified and directed.
Cleaning of filter bed of any capacity by removing efficient filter media to a depth of 30cm cleaning and washing the aggregate, relaying, spreading leveling and making good the filter bed to original level by using serviceable filter media aggregate retrieved after cleaning and with new 12.5mm and 20mm graded trap stone aggregate (Supply of new aggregate shall be measured and paid in respective items of Sch 'A').
Taking out liquid/solid content from sump/septic tank and sewage lines using vehicle mounted sewer suction machine (Honey sucker) including disposal of liquid/solid content out of the Cantt Area including cleaning thoroughly with fresh water complete all as specified and directed. Note:- Suction Unit shall be capable of syphoning out mud and slurry, grit and other material from sanitary, storm and sewerage systems from a depth of minimum 8 m.
Cleaning and clearing of blocked underground sewage line of 300mm dia pipe (RCC/ SWG/ PVC) mechanically by jetting using pressure and flushing after cleaning including clearing of manholes by taking off menhole covers and re-fixing the same after cleaning, taking out the muck, mud and other debris from inside the sewage line/manholes, removing the debris to a distance exceeding 200 m & not exceeding 250 m and covering the same with a layer of soil not less than 15cm thickness including excavation, in hard/dense soil etc all as specified in Sch A note no.21 and as directed. Note for serial item No 34 to 37:- The waste removal/ cleaning of sewage lines shall be cleaned through mechanically operated Jetting system only.
All as per item no. 34 above but 200mm dia pipes
All as per item no. 34 above but 150mm dia pipes.
All as per item no. 34 above but 100mm dia pipe.
Cleaning and clearing of blocked IWCs & EWCs to sewage line upto 1st manholes by rodding or any other suitable method & taking out the muck, mud and other debris from WCs and the sewage line cleaning with fresh water & removing the debris upto a distance exceeding 200 m & not exceeding 250 m and covering the same with a layer of soil not less than 15cm thick all as all as specified in Sch A note no.21 as directed .
Cleaning & clearing of blocked chocked floor trap in kitchen & bathrooms including gully trap, the waste water line connection etc by rodding or by any other suitable method & taking out the debris to a distance exceeding 200m & not exceeding 250m & covering the same with a layer of soil not less than 15cm thick complete and drain out the floors trap, gully traps, waste pipe and soil pipe with fresh water etc complete all as all as specified in Sch A note no.21 as directed .
Sagar Constructions
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .