| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.8 LAccepted-AOC 8 6TH CROSS MATHRU SHREE NILAYA OPP MAHARISHI RESIDENCE KAGGADASAPURA CV RAMAN NAGAR BANGALORE 560 093 | BENGALURU URBAN | KARNATAKA | 560093 | L1 | Accepted-AOC Being lowest bidder and reasonable | |
| 2 | L2₹34.4 L+₹2.5 L (7.75%)Rejected-AOC 15 MOULYA NMH LAYOUT 1ST STAGE CHIKKA BANAVARA POST BENGALURU 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | L2 | Rejected-AOC Not being lowest bidder | |
| 3 | L3₹34.7 L+₹2.7 L (8.55%)Rejected-AOC | L3 | Rejected-AOC Not being lowest bidder | |
| 4 | L4₹35.2 L+₹3.3 L (10.3%)Rejected-AOC | L4 | Rejected-AOC Not being lowest bidder | |
| 5 | L5₹36.6 L+₹4.6 L (14.4%)Rejected-AOC | L5 | Rejected-AOC Not being lowest bidder |
Tender Value
₹41 L
EMD Value
₹82,000
Closing Date
29 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I R nd D West Bengaluru
GARRISON ENGINEER I R nd D WEST BANGALORE DRDO COMPLEX CV RAMAN NAGAR BANGALORE
PERIODICAL SERVICES AND CERTAIN REPAIR WORKS FOR TYPE-I, II, III MARRIED ACCN OF DRDO COMPLEX, PHASE-I, C V RAMAN NAGAR, BENGALURU
2020_MES_344102_1
GE(I) R ND D (WEST)/BAN/07 OF 2020-21 8804E8
Open Tender
Civil Works
Item Rate
180 days
Bangalore
Class and Category as per NIT
8 documents required · 8 mandatory
₹500
GE I R nd D West Bengaluru
₹82,000
Yes
18 Aug 2020
27 May 2020
5 Aug 2020
28 May 2020
29 Jul 2020
21 Jul 2020
28 May 2020 - 20 Jul 2020
60 days
Amount
CIVIL WORKS
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) and disposing of debris outside MD land complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for; and disposing of debris outside MD land complete all as specified and as directed.
Demolition of cement concrete reinforced of any description and in any position not otherwise specifically provided for; including reinforcement cut as required to facilitate demolition, and disposing of debris outside MD land complete all as specified and as directed.
Demolition of Brickwork or stone/block masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles and disposing of debris outside MD land complete all as specified and as directed.
Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water, etc., and disposing of debris outside MD land complete all as specified and as directed.
Material and labour, reinforced cement concrete, M-15, using 20 mm graded stone aggregates, as in chajjas, complete all as specified and directed.
Material and labour, Pre-cast cement concrete block masonry with grade ‘C’ solid blocks exceeding 10 cm in width, having minimum compressive strength of 50 Kg / Sq cm as per IS 2185 (Part- I) 2005 and set in CM 1:6 complete all as specified and as directed.
Material and labour, Plain Cement Concrete 1:2:4, type B1, using 20 mm graded stone aggregates as in padding concrete, levelling course on roof, mixing with water proofing compound as per manufacturers instructions complete all as specified and as directed. Note : Supply only water proofing compound will be measured and paid separately under respective item.
Use and waste formwork to Chajjas, chullah hoods, troughs and similar surfaces, finishing concrete surfaces rough complete all as specified and as directed.
Use and formwork to edges of concrete flats, treads, breaks in floors, window cills concrete railing, openings in concrete walls, floor and roofs and sides of RCC bands in walls, horizontal or sloping and similar work exceeding 10 cm but not exceeding 20 cm wide fair finished surface of concrete complete all as specified and as directed.
Material and labour, steel reinforcement using TMT bars of 10 mm dia and over, cut to length, bent to shape required, including cranking, bending and binding with mild steel wire (annealed) and not less than 0.9 mm dia complete all as specified and directed.
Taking down unserviceable wire mesh, supply and fix new, Stainless steel wire cloth 0.36 mm (nominal dia of wire) and average width of aperture 1.40 mm and fixed with stainless steel wire staples, complete all as specified and as directed.
Material and labour, 75 mm thick Plain Cement Concrete (1:3:6), type C1, using 20 mm graded stone aggregates as in plinth protection laid in panels, with finished fair surfaces of concrete without using extra cement including forming joints, complete all as directed.
Supplying only liquid based integral water proofing compound complete all as specified and as directed.
Material and labour, for rendering 10 mm thick in Cement mortar 1:6, on brick work/concrete surfaces finished even and smooth without using extra cement complete all as specified and directed
Renewing non skid ceramic tiles in patches area not exc.5 sq m including preparing the beds and laying of new tiles setting jointing and pointing etc matching with the existing surfaces, including 15 mm thick cement screed bed, 1:6, complete all as specified and as directed.
Renewing glazed ceramic tiles in patches area not exc.5 sq m including preparing the beds and laying of new tiles setting jointing and pointing etc matching with the existing surfaces, including 10 mm thick backing coat in CM 1:3, complete all as specified and as directed.
Material and labour for, rendering 15 mm thick (5 mm thick in CM 1:4 over 10 mm thick Cement mortar 1:6), on brick work/concrete surfaces finished even and smooth without using extra cement, including mixing water proofing compound in 5 mm thick plaster complete all as specified and directed. Note : i) Supply only water proofing compound will be measured and paid separately under respective item. ii) Area to be plastered may require to be carried out up to height of 15 m, necessary scaffolding required shall deemed to be included in rate quoted against this item.
Material and labour for, rendering 5 mm thick on brick or concrete ceiling surfaces in cement mortar(1:3) and finishing the surfaces even and smooth without using extra cement complete all as specified and as directed.
Preparation of new or previously untreated plastered wall surfaces of any description not otherwise described and applying two coats of oil bound distemper over a coat of alkali resistant primer over and including 1 mm thick wall care putty, complete all as specified and as directed. Note : Quoted rate shall deemed to include for cost of wall care putty.
Preparing newly plastered surfaces of walls and applying two coats of weather proof exterior emulsion paint (anti fungal) over weather coat primer complete all as specified and directed. Note : Height of Bldgs varies from 12 m to 15 m, hence, cost of scaffolding and other factors governing for working at these levels shall deemed to be included in quoted rate.
Preparation of new or previously untreated plastered ceiling surfaces of any description not otherwise described and applying two coats of oil bound distemper over a coat of alkali resistant primer over and including 1 mm thick wall care putty, complete all as specified and as directed. Note : Quoted rate shall deemed to include for cost of wall care putty.
Preparing old plastered surfaces of walls and applying one coat of cement based paint complete all as specified and directed. Note : Height of Bldgs varies from 12 m to 15 m, hence, cost of scaffolding and other factors governing for working at these levels shall deemed to be included in quoted rate.
Preparing old plastered ceiling surfaces of any description and applying one coat of oil bound distemper complete all as specified and as directed.
Complete removal of existing treatment and preparing the surfaces of walls and applying two coats of oil bound distemper over a coat of alkali resistant primer over 1 mm thick wall care putty complete all as specified and directed. Note : Quoted rate shall deemed to include for cost of wall care putty.
Complete removal of existing treatment and preparing the surfaces of ceilings and applying two coats of oil bound distemper over a coat of alkali resistant primer over 1 mm thick wall care putty complete all as specified and directed. Note : Quoted rate shall deemed to include for cost of wall care putty.
Preparing of old wall surface of any description and applying one coat of distemper oil emulsion complete all as specified and as directed.
Preparation of old wooden surfaces of any description not other wise described over 10 cm width or girth applying one coat of synthetic enamel paint complete all as specified and as directed.
Preparation of old steel surfaces of any description not other wise described over 10 cm width or girth applying one coat of synthetic enamel paint complete all as specified and as directed. Note : Height of Bldgs varies from 12 m to 15 m, hence, cost of scaffolding and other factors governing for working at these levels shall deemed to be included in quoted rate.
Hacking out old broken glass from windows / ventilators, Supply and fix Plain Sheet glass 4 mm thick, ordinary quality and glazing with oil putty in square not exceeding 0.5 sq. m in each pane all as specified and as directed.
Hacking out old broken glass from windows / ventilators, Supply and fix pin head glass 4 mm thick, ordinary quality and glazing with oil putty in square not exceeding 0.5 sq. m in each pane all as specified and as directed.
Taking down tubular curtain rod, supply and fixing drapery rod, decorative type, made of 25 mm dia mild steel pipe powder coated (wall thickness not less than 0.63 mm), bright finish, colour and pattern as approved by GE, complete all as specified and as directed. (Note : Price shall not be less than 100/- per RM, Make : Aerolux / Vista / MEC)
Taking down brackets for curtain rod, supply and fixing brackets suitable for drapery rod of 25 mm dia, with wall thickness of 0.63 mm thick, bright finish, colour and pattern as approved by GE, complete all as specified and as directed. (Make : Aerolux / Vista / MEC)
Disconnecting existing PVC water tank of capacity exceeding 250 litres, but not exceeding 500 litres (fixed on roof), setting aside (or lowering if required), cleaning, removing all scales, dirt from tanks, from mouths of circulating pipes, etc., and hoisting / re-fixing / re-connecting in same / new position, writing date of cleaning with white paint, (height / size of letters / figures not less than 10 cm in height, re-fixing serviceable ball valve, complete all as specified and as directed.
Uprooting or scrubbing plants / shrubs / flora / fauna on walls, girth not exceeding 100 mm, cutting holes in walls, digging out roots applying sulphuric acid / phenolic acid as per manufacturers instructions to burn out deep grown roots and making good the surface using CM 1:3 (mixed with and including water proofing compound) complete all as specified and as directed. Note : Height of Bldgs varies from 12 m to 15 m, hence, cost of scaffolding and other factors governing for working at these levels shall deemed to be included in quoted rate.
Taking down GI tubing of 20 mm bore, cleaning and re-fixing on wall/ ceiling or laid on floors, etc, in old or new position complete all as specified and as directed.
Taking down eaves gutters, soil / waste / vent pipes / rain water pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., Supply and fix, UPVC (SWR) pipes 110 mm dia single socketed in any length with solvent cement joints laid under floor or on walls fixed as soil / waste / vent pipes with Stack clamps made out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall complete all as specified and as directed.
Supply and fix, UPVC (SWR) bends any radius for 110 mm dia bore, complete all as specified and as directed.
Supply and fix in repairs Ball valves of 20 mm dia , (minimum weight 210 grams) , high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe complete all as specified and as directed.
Moulya Builders
UNITED ENGINEERS CORPORATION
SREE SIDDESHWARA TRADERS
Atom Engineers and Builders
Solar Electricals and Electronics
ABHISHEK CONSTRUCTIONS
C R R CONSTRUCTIONS
RASHMI BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .