Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.7 LAccepted-AOC | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹44.4 L+₹7,382 (0.17%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹48.4 L+₹4.0 L (9.08%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹51.6 L+₹7.2 L (16.2%)Rejected-Finance | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹52.0 L+₹7.6 L (17.1%)Rejected-Finance | L5 | Rejected-Finance Not being lowest |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
29 May 2023, 6:00 pmClosed
GE I R nd D West Bengaluru
GARRISON ENGINEER I R nd D WEST BANGALORE DRDO COMPLEX CV RAMAN NAGAR BANGALORE
ADDITION ALTERATION AND SPECIAL REPAIRS TO OPEN AIR THEATRE IN PHASE-I , DRDO TOWNSHIP CV RAMAN NAGAR BANGALORE
2023_MES_586884_1
GE(I)/R ND D/BAN/TOKEN/90 OF 2022-23 8148/E8
Open Tender
Coal Works
Item Rate
180 days
GE I R nd D West Bengaluru
Class and category as per NIT
9 documents required · 9 mandatory
₹500
GE I R nd D West Bengaluru
₹96,000
Yes
18 Jul 2023
25 Apr 2023
5 Jun 2023
26 Apr 2023
29 May 2023
11 May 2023
26 Apr 2023 - 10 May 2023
Amount
Demolition of stone slabs of any thickness and in any position, and disposing of debris outside MD land complete all as specified and as directed.
Demolition of cement concrete reinforced of any description and in any position not otherwise specifically provided for; including reinforcement cut as required to facilitate demolition complete all as specified and as directed.
Demolition of stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, separating and stacking the serviceable material and disposing the unserviceable material outside MD land complete all as specified and directed.
Demolition of floor, hearth or wall tiling including cement mortar bedding (including bedding / backing coat), removing serviceable tiles to store and rubbish off the premises and disposing of debris outside MD land complete all as specified and as directed.
Taking down Chowkats or frames with shutters (without taking off shutters from the frames) area of opening exceeding 1.5 sq m, but not exceeding 4 sq m each all as specified and as directed.
Taking down shutters of any description of area not exceeding 3 Sq m each complete all as specified and as directed.
Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water, etc., and disposing of debris outside MD land complete all as specified and as directed.
Supply only liquid water proofing compound all as specified and as directed.
Walling with Coursed rubble masonry with hard stone (first or second sort), well bonded, bedded and solidly hearted, built in CM(1:6), in plinth and superstructure upto five floor level including flush/ ruled pointing in cement mortar 1:3 complete all as specified and directed.
Providing and placing in position precast reinforced cement concrete waffle units, square or rectangular, as per design and shape for floors and roofs in 1:1½:3 (1 Cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 10 mm nominal size derived from natural sources), including flush or deep ruled pointing at joints in Cement mortar 1:2 (1 Cement : 2 Fine sand), making necessary holes of required sizes for carrying through service lines etc., providing steel hooks for lifting etc, form work in precasting, handling, hoisting, centering and erection complete for all floor levels but, excluding the cost of reinforcement.
Material and labour, steel reinforcement using TMT bars of any dia and over, cut to length, bent to shape required, including cranking, bending and binding with mild steel wire (annealed) and not less than 0.9 mm dia complete all as specified and as directed.
Supply and fix, 30 mm thick Factory made solid panel PVC door shutter consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat molded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Paneling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete including Solid PVC door frame of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube, including making good to jambs with cement mortar (1:4) and finished to match with existing surface complete all as specified and as directed.
Supply and fix 35 mm thick plain framed panelled factory made shutters (two panel) with II nd class hardwood rail and style with lock rail and panel of 12 mm BWP commercial ply with commercial veneer on both faces. The size of rail and style as per IS - 1003 Part - I , kiln seasoned and chemically pressure treated complete all as specified and as directed.
Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc of size 100x63x4mm. complete all as specified and as directed.
Supply and fix Aluminium anodized barrel tower bolts of extruded section, 200x10 mm size complete all as specified and as directed.
Supply and fix Aluminium anodized barrel tower bolts of extruded section, 100x10 mm size complete all as specified and as directed.
Supply and fix 100 mm Aluminium extruded alloy anodized handles, cast type complete all as specified and as directed.
Supply and fix, Stainless steel Butt hinges, 125 mm long fixed with screws complete all as specified and as directed.
Supply and fix, Stainless steel Butt hinges, 100 mm long fixed with screws complete all as specified and as directed.
Supply and fix chromium plated , fancy type towel hook with three to four arms hangers all as specified and as directed.
Supply and fix powder Coated aluminium frames and shutters (minimum thickness of powder coating 50 microns) and fabricating of doors, windows, ventilators and fixed partitions with one or more rebates including necessary joining cleat, glazing clips, rubber packing, snap bending crews etc. complete all as specified and as directed. Note :- i) For payment purpose weight of aluminium section shall be measured and paid, ii) Cost of aluminium mongery. lock, rubber packing, rollers for sliding shall be deemed to include in the quoted rate, iii) Sheet glass and wire gauge shall be measured and paid for separately under respective items.
Material and labour, for Matt finished heavy duty vitrified tiles flooring 8-10mm thick (Square / rectangular), tiles of size 600 x 600 mm, set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 20 mm thick screed bed in CM (1:4) complete all as specified and as directed.
Material and labour, for vitrified tiles flooring with light shade 10mm thick (Square / rectangular) tiles of size 600 x 600 mm, set and jointed in neat cement slurry over and including 5mm thick polymerized (latecrete) on existing tiles and pointed in epoxy grout to match colour of tiles all as specified and as directed.
Material and labour, non-skid Ceramic coloured tiles 7 to 8 mm thick (Grade B-II a), area of each tile exceeding 0.06 sq m but not exceeding 0.11 sq m, as in flooring, set and pointed in white or coloured cement to match colour of tiles over and including 20 mm thick screed bed in CM (1:4) complete all as specified and as directed.
Material and labour, for 1st quality ceramic coloured tiles, of size 600 x 300 x 8-10 mm thick (Grade B-II a) as in vertical surfaces such as skirting, dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including provision of backing coat of 10 mm thick in CM 1:3, complete all as specified and as directed.
Demolition of stone slabs of any thickness and in any position, providing material and labour, for 18 to 20 mm thick Granite work (of any type), table rubbed and mirror polished), in single piece in steps, jambs, pillars, window-cills, cooking platform and like set in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, making hole for gas pipe, edges made half round, laid over and including screed bed or bedding layer of 20 mm thick in CM (1:4), complete all as specified and as directed.
Material and labour for Machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete and including screed bed of 15 mm thick in CM (1:6) complete all as specified and as directed.
Material and labour for Machine cut kota stone slab 20-25 mm thick in risers of steps, skirting, dado and other vertical surfaces over cement back coat laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete and including cement backing coat of 15 mm thick in CM (1:4) complete all as specified and as directed.
Material and labour for Chequered cement concrete tile flooring with commercial tiles of size 25 cm x 25 cm x 20 - 25 mm thick/ 30 cm x 30 cm x 20-25 mm thick, with grey cement and pigments, set, jointed and pointed in neat cement slurry, over and including screed bed of 20 mm thick in CM (1:4) complete all as specified and as directed.
Rendering 15 mm thick on stone masonry surfaces or surfaces other than fair faces in cement mortar(1:4) and finishing the surfaces even and smooth without using extra cement, all as specified and as directed.
Material and labour for, rendering 15 mm thick in cement mortar 1:4 on brickwork or concrete surfaces, finishing even and smooth including mixing with water proofing compound complete all as specified and as directed. Note:- Supply only water proofing compound will be measured and paid for separately under respective item.
Preparing the new plastering surfaces of walls and applying two coats of exterior emulsion paint over a coat of weather coat primer all as specified and directed.
Complete removal of existing treatment and preparing the ceiling surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed.
Complete removal of existing treatment and preparing the surfaces of walls and applying two coats of exterior emulsion paint over a coat of weather coat primer all as specified and directed.
Preparing the new plastering surfaces of walls and applying two coats of oil bound distemper over a coat of alkali resistant primer over 2 mm thick wall care putty complete all as specified and directed. Note : Quoted rate shall deemed to include for cost of wall care putty.
Complete removal of existing treatment and preparing the surfaces of walls and applying two coats of oil bound distemper over a coat of alkali resistant primer over 2 mm thick wall care putty complete all as specified and directed. Note : Quoted rate shall deemed to include for cost of wall care putty.
M&L for water base exterior emulsion paint with special grade mica marble barrier protection, paint film reinforcement, increased coat adhesion and toughness painting concrete benches in following steps. (a) Cleaning the surface by presser jet spray and removing all dust particle (b) Applying two coats of water proof cement base putty and make the surface smooth by emery paper. (c ) Applying one coat of moisture resistant primer (d) Applying two coats of water based exterior emulsion paint with special grade of mica and marble enhanced barrier protection, & inter-coat adhesion and toughness, the dry thickness shall be 35-40 microns completed all as specified and directed by Engr-in-charge
S&F Pillar taps.15mm dia fancy type chromium plated with CP flange, long shank all as per Cat No-F280001 of hindware or equlivaent in other makes specified and here-in-after after taking down old pillar taps complete all as specified and as directed
Providing and fixing factory made P.V.C. door frame of size 50x47 mm with awall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineer in-Charge
M&L cleaning the floor surface by presser jet spray and removing all loose dust pertical and Floor painting with two coats of weather coat floor protector paint suitable for exterior cement concrete floors/pavements etc of approved brand to give an even shade including cleaning and preparation of old /new surfaces, all as specified and directed
Supply and fix Plain Sheet glass 4 mm thick, ordinary quality and glazing with oil putty in square not exceeding 0.5 sq. m in each pane all as specified and as directed.
Supply and fixing 15 mm bore Galvanized Iron tubing, medium grade, with all fittings, such as Tee, elbows, sockets, unions, short pieces and application of bituminous paint in concealed portion, fixed to wall/ ceiling or laid on floors, complete all as specified and as directed.
Supply and fixing 20 mm bore Galvanized Iron tubing, medium grade, with all fittings, such as Tee, elbows, sockets, unions, short pieces and application of bituminous paint in concealed portion, fixed to wall/ ceiling or laid on floors, complete all as specified and as directed.
Supply and fix Angular stop cock, fancy type, CP brass with chromium plated wall flange, screwed both ends for iron pipe or for brass ferrule,15mm dia, complete all as specified and as directed. MAKE:- Cat No. F280004 of hindware or equivalent in other makes or techno-commercially equivalent makes specified in list of makes here-in-after.
Supply and fix brass Bib taps 15 mm dia, fancy type, chromium plated with CP flange all as specified and as directed. Hindware (cate part No F280002).
Supply and fix Health faucet, with 8 mm dia, 1.2 m long, flexible tube in chrome finish, wall hook with NRV (back flow preventer), all as per Cat Part No F160023 of Hindware or techno commercially equivalent in other makes complete all as specified and directed.
Supply and fix in repairs, 32 mm dia, PVC waste pipe of length not less than 800 mm, complete all as specified and as directed.
Supply and fix two way, bib taps, fancy type, 15 mm dia, brass, chromium plated, with CP flange, screwed for iron pipe or for brass ferrule, all as per Cat No.F280003 of Hindware or equivalent in other makes specified complete, all as specified and as directed.
Supply and fix, PVC connecting pipe 450 mm long 15 mm dia both ends having brass coupling nut and PVC washer complete all as specified and as directed.
Supply and fix in repairs, Vitreous china, white colour, water closet pan (pedestal pattern), with PP soft seat cover, hinges, other fixing accessories set (excluding flushing cistern and flush pipe), UPVC (SWR), 'P' or 'S' trap, and connecting to drain (or outgoing pipe), flush pipe, anti syphonic pipes, Make : Cat Part No S1050102 of Cera or techno commercial equivalent in other makes complete all as specified and as directed.
Supply and fix in repairs, Vitreous china, white colour, 'Orissa pattern' squatting pan of size 580 mm x 440 mm with UPVC 'P' trap or 'S" Trap, front or back inlet, integral foot rests, connecting to trap, flushing pipe, anti syphonic pipe, complete, all as per Make : Cera, Cat No S3010102 of CALINA make or techno commercially equivalent in other makes specified complete all as specified and directed.
Supply and fix in repairs, PVC valve less, syphonic action type, white colour flushing cistern, 10 litres capacity, low level, white, with inlet, ball valve, float and handle including jointing with new PVC long / short flush bend and making good to the disturbed surfaces complete all as per Model No: CIENA PREMIUM Cat Part No B1010102 of CERA Make or techno commercial equivalent in other makes complete all as specified and as directed.
Supply and fix in repairs.vitreous china snow white, counter sunk oval type wash hand basin of size 560mm x 470 x 190 mm all as per cat no s2030104 of cera or techno commercial equivalent makes specified including supply and fixing suitable bracket, including waster coupling and counter sunk , all as specified and as directed.
Supply and fixing Stainless steel sink without draining board, made out of 1.00 mm thick sheet for kitchen over all size 610 mm x 460 mm with bowl depth 200 mm all as per Cat No.SSSBS-25 of Blue Star make or techno commercially equivalent in other makes specified including CP waste coupling of 40 mm dia, cast iron cantilever brackets, 40 mm dia 800 mm long corrugated PVC waste pipe, washers, connecting union etc. complete all as specified and directed.
Supply and fix vitreous China urinals, half stall type, white, flat back type wall mounted of size 365x335x670 mm of Cera (Cat No. S4020107) or equivalent in other makes with auto closing flush valve with valve flange and 200 mm connecting pipe fitting of CERA (Cat No. F9020203) or equivalent in other makes, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; with brackets, flush pipe, grating and Union for discharge pipe including wall hung urinal glass division of size 450x900x8 mm thick (Cat Part No SU81OSC(C)-STD-CR) complete all as specified and as directed.
Supply and fix, UPVC (SWR) pipes 110 mm dia single socketed in any length with solvent cement joints laid under floor or on walls fixed as soil / waste / vent pipes with Stack clamps made out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall complete all as specified and as directed.
Supply and fix, UPVC (SWR) pipes 75 mm dia single socketed in any length with solvent cement joints laid under floor or on walls fixed as soil / waste / vent pipes with Stack clamps made out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall complete all as specified and as directed.
Suppy and fix floor / Nahani trap, supply and fix UPVC(SWR) floor trap 75 mm dia outlet with CP grating, including jointing with solvent cement complete all as specified and as directed.
Supply and fix stainless steel grating, 100 mm dia, including fixing with white cement complete all as specified and as directed.
Taking down old / defective copper point wiring of any type (light, fan, socket or power) from the existing locations complete including fixture and fittings such as conduit pipes, sunken boxes, laminated sheets along with switches, sockets, regulators, ceiling roses etc. removing materials and making good disturbed surfaces of walls, floors, ceiling etc to match with the adjoining surfaces complete all as specified and directed by Engineer-in-charge. Note : Cutiing chases / grooves etc on walls / ceilings as applicable as per site and making good disturbed area shall deemed to be included in the quoted rate of this item.
Material and labour for point wiring from switch board to light/fan/socket point with, single core, PVC insulated, unsheathed, multi stranded copper conductor, 1100 V grade, FRLS cable of size 1.5 sq.mm, 1100 grade, with single core, PVC insulated unsheathed multi stranded copper conductor cable of size 1.5 sq.mm for earth continuity wire, with concealed PVC conduit of size not less than 20mm including all cutting / chases as applicable with modular switch, modular plate,suitable GI box and earthing the point with 1.5 FRLs copper conduter single core cable. including all necessary wall cutting and making good disturbed surface complete all as specified and directed for One light / fan / bell point controlled by one, one way switch 5/6 Amps complete all as specified and as directed.
All per Serial Item No 64 here-in-above, but suitable for 3-pin, socket outlet 5 Amps, fixed on same board.
All per Serial Item No 64 here-in-above, but suitable for 3-pin, socket outlet 5 Amps, on independent board.
Material and labour point wiring with 1.5 sqmm FRLS grade single core PVC insulated, unsheathed, 1100V grade copper multistranded conductor for the following concealed type incliuding new PVC conduit of size not less than 20mm with modular two way switch,modular plate,suitable GI box and earthing earthing the point with 1.5 FRLs copper conduter sigle core cable. complete with all PVC conduit and accessories/ fittings, brass screws, washers etc, along with modular suitable factory made Sunken boxes concealed including all cutting/chases as applicable etc or surface type PVC boxes factory made (where concealing boxes is not possible as per site conditions) to accomodate modular plates, covers modular switches & sockets etc in walls and including PVC insulated copper earth continuity conductor 1.5 Sqmm FRLS cable green colour connected to common earth dolly complete making good the disturbed surface of wall, floors, ceiling etc complete all as specified and directed by Engineer-in-charge for One light / fan / bell point controlled by two way switch 5/6 Amps complete all as specified and as directed.
Taking down carefully existing unserviceable / burnt sub main wiring of any size and type, taking down concealed / surface conduit, casing capping etc as per site conditions, making good the disturbed surfaces of walls, ceilings etc with two coats of white /colour washing/ distempering disturbed surfaces to match with the existing adjacent surfaces etc complete all as directed by Engineer-in-charge. Note - Cuttung/grooves/chiseling as applicable shall be measured and pad separately. (2) The quoted rate by the tenderer is inclusive for making good distrubed concealed/ surface conduit wiring portions in all respects to match with the adjoining surfaces.
Material and labour for submain wiring with two single core PVC insulated cable copper conductor multi standed of size 1.5 Sqmm FRLS, including one 1.5 sqmm copper cable as earth continuity drawn through in and including new PVC non mettallic rigid concealed type including new PVC conduit of size not less than 20mm including all cutting / chases as applicable. including all accessories complete all as specified and directed by Engr-in-charge. NOTE: - Two run of 1.5 sqmm cable, one run 1.5 sqmm cable and one run of PVC conduit shall be measured as one length.
Material and labour for submain wiring with two single core PVC insulated cable copper conductor multi standed of size 2.5 Sqmm FRLS, including one 1.5 sqmm copper cable as earth continuity drawn through in and including new PVC non mettallic rigid concealed type including new PVC conduit of size not less than 20mm including all cutting / chases as applicable.including all accessories complete all as specified and directed by Engr-in-charge. NOTE: - Two run of 2.5 sqmm cable, one run 1.5 sqmm cable and one run of PVC conduit shall be measured as one length.
Supply and fix Modular socket, 5/6 Amps, 3 pin , two module 240 Volts flush
Supply and fix in replacement of Modular socket, 6/16 Amps, 3 pin , two module 240 Volts multipurpose all as specified and as directed.
Supply and fix Modular Switch, One module , One way, 16 Amps, 240 Volts all as specified and as directed.
Supply and fix three module ,100x75mm size GI box alongwith modular base and cover plate for modular switches for mounting 1 switch and 1 socket 15/16 Amps all as specified and as directed.
Supply and fix in replacement of Modular fan Regulator,120 W, electronic stepped type, 230 Volts 2 module, complete all as specified and as directed.
Supply and fix in replacement of Ceiling rose surface type, Bakelite, 65 x 50 mm ISI marked with three terminals all as specified and as directed.
Supply in repairs, fixing and testing VTPN TPN DB 8 way sheet metal encloused flush type mounted Vertical Double door factory made powder coated with 200 Amps rated busbar 415 IP-43 Volts capacity for using MCCB as incomer and MCBs as out going circuits complete all as specified and directed by Engr-in-charge. Note - Copper wires, MCCB s and MCBs as per site requireemnts shall be measured and paid separately under relevent item
Supply in repairs and fix, MCB DB SPN 8 way (Horizontal), double door with Sheet metal enclosure, flush mounted, prewired, 240 V, AC, 50 Hz, Factory made, powder coated, IP-43 protection conforming to IS-13032 universal mounting with 200 Amps rated copper bus bar, neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides, etc complete all as specified and as directed. Notes : i) All unused modules shall be provided with blanking plate for which the cost is deemed to be included in the cost of MCB DBs. ii) MCB/ Isolators will be measured and paid separately as supply and fix under respective items.
Supply and fix in replacement of MCB DB SPN 4 way (Horizontal), double door with Sheet metal enclosure, flush mounted, prewired, 240 V, AC, 50 Hz, Factory made, powder coated, IP-43 protection conforming to IS-13032 universal mounting with 200 Amps rated copper bus bar, neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides, etc complete all as specified and as directed. Notes : i) All unused modules shall be provided with blanking plate for which the cost is deemed to be included in the cost of MCB DBs. ii) MCB/ Isolators will be measured and paid separately as supply and fix under respective items.
Supply and fix MCCB 100 Amps 415 Volts 16 KA 4 pole using copper lugs for terminations including taking down old MCCB complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of MCB SP 6 - 32 Amp 240 Volts 10 KA C curve using copper lugs for terminations complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of MCB SPN 6 - 32 Amp 240 Volts 10 KA C curve using copper lugs for terminations complete all as specified and directed by Engr-in-charge.
Material and labour for submain wiring with Four single core PVC insulated cable copper conductor multi standed of size 10 Sqmm FRLS, including two 10 sqmm copper cable as earth continuity drawn through in and including new PVC non mettallic rigid concealead type including new PVC conduit of size not less than 20mm including all cutting / chases as applicable. including all accessories complete all as specified and directed by Engr-in-charge. NOTE: - Four run of 10 sqmm cable, two run 10 sqmm cable and one run of PVC conduit shall be measured as one length.
Material and labour for submain wiring with Two single core PVC insulated cable copper conductor multi standed of size 4 Sqmm FRLS, including one 4 sqmm copper cable as earth continuity drawn through in and including new PVC non mettallic rigid concealead type including new PVC conduit of size not less than 20mm including all cutting / chases as applicable. including all accessories complete all as specified and directed by Engr-in-charge. NOTE: - Two run of 4 sqmm cable, one run 4 sqmm cable and one run of PVC conduit shall be measured as one length.
Supply and fix in replacement of DP sheet metal enclosure on surface / recess alongwith 25-32 Amps 'C' curve DP MCB complete all as specified and as directed.
M&L Dismantling u/s ceiling fan from wall/ ceiling/ any postion and Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) all as specified and directed.U/S Ceiling fan to be deposited in store yard.
Supply and Replacement of open LED bulk head light 10W complete water proof covered approved model complete with 3 core sheathed copper flexible 1 sqmm wire upto light fitting and PVC connector complete all as specified and as directed.
Supply and fixing wall mounted LED batten, 20 Watt, 4 feet, with high lumen output of 2000 lumens and diiffuser should be High translucent serrated milky white , environmental friendly, energy efficient LED, with accessories, IP 20 protection Class I, system electrical efficiency > 85%, system efficacy > =100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH <20%, power factor ≥ 0.90, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80 & integrated electronic driver 20 W fitting prewired and connecting with 3 Core, 1 sq mm sheathed copper flexible cable including taking down existing complete in all respects all a directed by Engineer-in-charge.
Supply and fixing wall mounted LED tube light fitting 9 Watt 2 ft with high lumen output, environmental friendly, energy efficient LED, with accessories, IP 20 protection Class I, system electrical efficiency > 85%, system efficacy > 100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH, 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, intergral drivers, complete with diffuser, polyestyer louver with 9 watt LED tube & integrated electronic driver 9 W prewired and connecting with 3 Core, 1 sq mm sheathed copper flexible cable complete in all respects all a directed by Engineer-in-charge.
Taking down existing security light fitting, Supply and fix 36 W, LED security light fittings with lamp 36 With high lumen output, environmental friendly, energy efficient LED, with pressure die cast housing with toughened glass and high power LEDs with secondary optics, with lamps and accessories, IP 66 protection, system electrical efficiency > 85%, system efficacy > 110 IP/W, 10 KV SPD, operating voltage between 140 - 270 V, AC, 50 Hz, TDH, 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, integral drivers, connecting to loop boxes electrically, light fittingl complete with all accessories and lamp complete all specified and as directed .
Taking down existing outdoor flood light fitting, Supply and fixing out door type flood light fitting 250 watts toughened glass comprising of energy saving , environmental friendly, long life, exclusive innovative die cast aluminium IP-66 10 KV SPD lumens suitable for dark areas / high Mass lighting building display lighting including taking down carefully defective fitting of any type complete all as directed by Engineer-in-charge .
Dismantling / opening of exhaust fan of 300/450mm sweep motor assembly inspecting all dismantled parts repairing replacing the unserviceable parts and following components with new ones including oiling greasing reassembling motor assembly all as specified and directed. NOTE:- Cost of PVC capacitor bracket -1 No, split pins - 1 Nos, & 2 mfd Capacitor - 1 No, shall be included in this item.
Rewinding of exhaust fan motor 300/450 mm sweep with super enameled copper winding wire of suitable gauge after cutting and removing burnt winding, including varnishing of new winding and drying up carefully all as specified and directed.
Material and labour for preparing old painted surfaces of exhaust fans of 300/450 mm sweep, and applying spray painting with two coats of synthetic enamel paint of approved colour, including writing MES No on painted surfaces, complete all as specified and as directed.
Taking out the existing earth and Material and Labour for earthing complete with GI earth platee electrode 60cm x 60cm x 6 mm thick buried directly in ground earth pit not less than 2.25 M deep below normal ground level and complete earth plate connected to GI wire 4 mm by brazing only earth strip protected with light grade GI Pipe 15 mm dia bore from earth plate electrode and upto in and including the earth test point including 20mm bore water pipe medium grade GI Tubing including GI Funnel,wire mesh. alternate 5 layers of charcoal & salt crystal and removal of the excavated soil and depositing at the place where directed,PCC Pit in PCC (1:3:6) type C1 using 20 mm graded stone aggregate , RCC (m) Cover 40 mm thick in RCC (1:2:4) type B 1 using 20 mm grade aggregate reinforced with 8 mm dia TMT bars @ 7.5 mm c/c both ways including RCC Pit Cover etc watering the earth pit to acheive earth resistance below 02 Ohm incl testing complete all as specified and directed by Engineer-in-Charge.Note :- GI wire 4 mm,GI Tubing 15 mm light grade upto 7.5 mtr deemed to be included in the rate quoted by the contractor.
Supply, fixing, drawning GI wire 4 mm in GI pipe 15 mm pipe in earthing complete all as specified and as directed by Engr - in -charge.
Taking down & Repair and refixing existing Electronic energy meters domestic type 10-60 Amps, AC,Three phase, digital type, static energy meter of accuracy class 1.0, 3 working on 240 volts, 50 Hz with back lit LCD display with special features like TOD, tamper logging, optical communication port & display in absence of power including testing meter serviceablity after calibration replacing brass screw of all as specifie and directed.
Supply and Replacement of on load change over switch 415V in sheet metal enclosure, 4 pole of capacity 200 Amps al as specified and directed.
Supply and laying New 1100 V XLPE LT cable, insulated, screened, bedded galvanized steel strip armoured heavy duty with aluminum conductor, of cross sectional area 50 sq mm 3.5 core with cable protection works (as applicable) laid in trenches/ ducts/ fixed on pole/ wall/ laid under road/ path/ culvert/ drains/ encased in pipe, including necessary lugs, jointing and testing including taking down old cables complete all as specified and as directed.
Supply and laying New 1100 V XLPE LT cable, insulated, screened, bedded galvanized steel strip armoured heavy duty with aluminum conductor, of cross sectional area 6 sq mm 2 core with cable protection works (as applicable) laid in trenches/ ducts/ fixed on pole/ wall/ laid under road/ path/ culvert/ drains/ encased in pipe, including necessary lugs, jointing and testing complete including taking down old cables all as specified and as directed.
Supply and Replacement of decorative, hot dipped mild steel pole with grey powder finish compatible for 6mtr POLE including excavation work for foundation, PCC foundation and coping of 1:3:6 20mm agregate, connection with light by suitable cable from Cable Junction box all as specified and directed.
Taking down existing post top lantern light fitting, Supply and fixing LED Outdoor Decorative Post top lantern fitting 15 watt for 360° indirect light with IP 65 protection. Resistant to impact and corrosion. Glare-free and better uniformity and System efficacy ≥ 100Lm/w , operating voltage between 140 - 270 V, AC, 50 Hz, PF >= 0.95,THD<10%, CCT 5700K, CRI >= 70 and Driver Should be Potted type Constant Current LED Driver with 4KV Inbuilt Surge, Driver Efficiency >85%, Driver having High Voltage, Short Circuit Protection and Driver Should be with BIS Certified with R number
Supply and Replacement of cable junction box made of high quality DK thermoplastic of size 200X160X98 mm including four number connection terminals suitable mouted on DN rail for alumn cables upto 25 sqmm 4 core with one single pole MCB 'C' curve type of current rating 6 amps and rupturing cap 10 KA complete with thermoplastic cable glands and fixed on GI Pipe and using pole clamps made out of appropriate material all as required at site or directed including inspection/ site testing (after installation at site) by company engineer incl GI pipe for supporting cable.
Excavation in trenches not exceeding 1.5 m deep and not exceeding 1.5 m wide and getting out in soft / loose soil all as directed.
Excavation in trenches exceeding 1.5 m but not exceeding 3 m deep and not exceeding 1.5 m wide and getting out in soft / loose soil all as directed.
Returning and filling in, soils, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick all as directed.
Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed.
Screening excavated earth (passing through 12 mm square mesh), laying riddled earth in trenches for cable protection, under and above Cable all as specified in SSR Part - I (Clause No 19.75) and as directed by Engineer-in-Charge. Note : Punned thickness of riddled earth of 18 cm will be measured and paid.
Material and labour for plain cement concrete 1:3:6, type C1 (using 20 mm graded stone aggregate as in coping to poles, panels, etc., including necessary formwork, complete all as specified and as directed.
Taking down unserviceable cable protection pipe, Supply and Fixing on walls / pole with clamps / laid in trenches,40 mm bore Galvanized iron tubing, light grade, as cable protection, complete all as specified and as directed.
Supply and lay Unreinforced precast concrete cable covers, class LV, type 1, flat size 300mm x 180mm x 40mm complete all as specified and as directed.
Material and labour for roof treatment as follows:- (a) M&L Chip out the existing loosed bitumen / bitumen membrane completely reach up mother slab, clean the surface thoroughly to make it smooth and free of any foreign material, repairs the concrete wherever damaged using PMM HS repair, repairing of construction joints / cracks by chasing with cutting machine and fill the same with polymerized mortar in HS repair, coving of 75 x 75mm should be made at the junction of wall and raft slab using polymerized cement mortar in 15mm thick in CM (1:2) admixed with advanced latex plus. (b) Applying one coat of 50% diluted self priming PU roof coat. Allow to dry bond coat for 4-6 hours before applying PU coat and surface to be cleaned before applying PU coat. (c) Applying two coats of single component, cold applied, water based polyurethane modified acrylic dispersion with highly elastic and UV resistant water proofing treatment to the roof with HS PU roof coat of Berger or equivalent at 0.6 kg/sqm for each coat without dilution confirming to ASTM d 6083-97A (Strand Specification for liquid applied Acrylic coating used in roofing ) each coat should allow to dry 4-6 hours the component shall have a density of 1.25 to 1.3 kg/ltrs ,having tensile strength of 1.5 N/mm2, having elongation of 350% with solid content not less than 100. The Quoted rate shall include surface preparation , repair the crack in mother slab by chasing with cutting machine and fill the same with polymerized mortar in CM 1:4 admixed with latex agent of reputed manufacture, making coving at junction bore packing treatment of construction joints completely as per manufacturers specification and direction of the Engr-in-Charge.
Bikarma Enterprise
SREE BUILDERS
RAMYA CONSTRUCTIONS
Kaveri Enterprise
Meghana and Gowda Enterprises
Solar Electricals and Electronics
SRI LAKSHMI VENKATESHWARA ENTERPRISES
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .