| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.3 LAccepted-AOC | ₹28.3 L Quoted ₹28.9 L | L1 | Accepted-AOC Being L1 Bidder |
| 2 | L2₹31.3 L+₹2.4 L (8.42%)Rejected-AOC NO 14 M C RAJA STREET MITTANAMALLI I A F AVADI CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | ₹31.3 L+₹2.4 L (8.42%) | L2 | Rejected-AOC Not Being L1 Bidder |
| 3 | L3₹32.1 L+₹3.2 L (10.9%)Rejected-AOC | ₹32.1 L+₹3.2 L (10.9%) | L3 | Rejected-AOC Not Being L1 Bidder |
| 4 | Rejected-Technical 53 13 A OUTER CIRCULAR ROAD KILPAUK GARDEN COLONY CHENNAI 600 010 | CHENNAI | CHENNAI | TAMIL NADU | 600010 | - | - | Rejected-Technical Due to Slow Progress |
| Sl No | Description | Qty | Unit | Unique enterprises L1 | SRI VENKATESWARA ENTERPRISES L3 | SAMYDOSS CONSTRUCTIONS L2 |
|---|---|---|---|---|---|---|
| 1.00 | Material and labour for disconnecting electrical connections, removing the defective scroll compressor three phase, 10 to13TR capacity from the mounting bed of central type Air Conditioner plant , dismantle the unit by cutting and rewinding the compressor coil with Freon resistance Super enamelled copper wire and replace bearing and worn out parts of compressor with lathe work for proper alignment with fill up of lub oil and assemble the unit , fixed in Central AC plant Testing and commissioning chiller package AC system complete. The job is inclusive of cutting, transporting brazing the suction and discharge lines by, reconnecting at site as specified and directed by Engg-in-charge.
Note : (i) Refrigerant charging will be measured and paid separately under relevant.
(ii) Rewinding will be carried out through OEM only. | 2 | Job | 43,700 ₹87,400 Lowest | 46,200 ₹92,400 | 45,000 ₹90,000 |
| 2.00 | Material and Labour for carry out the leak test at any capacity of central AC plant refrigeration systems by charging the dry nitrogen gas & hold up to 24hrs and rectifying the leakage if any by brazing/ welding/ replacing the spare parts if any etc, complete all as specified and directed by Engg-in-charge.
Note :- The Spares measured and paid separately under respective items below. | 14 | Job | 4,370 ₹61,180 Lowest | 4,750 ₹66,500 | 5,000 ₹70,000 |
| 3.00 | Material and labour for recharging R-407A/ R-410A Refrigerant gas complete all as specified and directed by Engg-in-charge. | 180 | Kg | 1,570 ₹2,82,600 | 1,590 ₹2,86,200 | 1,550 ₹2,79,000 Lowest |
| 4.00 | Material and Labour for recharging R-22/ R-32 Refrigerant gas complete all as specified and directed by Engg-in-charge. | 120 | Kg | 1,579 ₹1,89,480 | 1,600 ₹1,92,000 | 1,550 ₹1,86,000 Lowest |
| 5.00 | Material and Labour for descaling the shell and tube condensors as per standard practice disconnecting the pipe line connection and removing the end cover, circulating diluted hydrochloric acid by pumping into copper tubes minimum half an hour and brushing. These copper tubes to be cleaned with nylon brush for removal of dirt and scales without damaging the tubes, removal of scales from the end cover and after ensuring all dirt and scales is removed wash the tubes with clean water in minimum one hour till all dust particles, scales washed out and re-assemble the condensor unit connect the pipe line and test and ensure the condensor working properly for the capacity upto 72TR complete all as specified and directed by Engg-in-charge. | 46 | Job | 2,390 ₹1,09,940 Lowest | 2,875 ₹1,32,250 | 2,600 ₹1,19,600 |
| 6.00 | Taking down electric motor of capacity 5 HP from Cooling tower/Chilled water pump set/Condenser water pump sets etc., carefully from its position and servicing complete including open the motor greasing, oiling and replacing of ball bearing rusted nuts, bolts, washers refixing the same position and painting with a coat of synthetic enamel paint over a coat red oxide primer complete for the following electric motors complete all as specified and directed by Engg-in-charge. | 4 | Each Job | 4,190 ₹16,760 Lowest | 4,320 ₹17,280 | 4,370 ₹17,480 |
| 7.00 | Taking down electric motor of capacity 7 HP from Cooling tower/Chilled water pump set/Condenser water pump sets etc., carefully from its position and servicing complete including open the motor greasing, oiling and replacing of ball bearing rusted nuts, bolts, washers refixing the same position and painting with a coat of synthetic enamel paint over a coat red oxide primer complete all as specified and directed by Engg-in-charge. | 4 | Each Job | 4,900 ₹19,600 Lowest | 5,000 ₹20,000 | 5,100 ₹20,400 |
| 8.00 | Taking down electric motor of capacity 10 HP from Cooling tower/Chilled water pump set/Condenser water pump sets etc., carefully from its position and servicing complete including open the motor greasing, oiling and replacing of ball bearing rusted nuts, bolts, washers refixing the same position and painting with a coat of synthetic enamel paint over a coat red oxide primer complete all as specified and directed by Engg-in-charge. | 4 | Each Job | 6,225 ₹24,900 Lowest | 6,500 ₹26,000 | 7,700 ₹30,800 |
| 9.00 | Taking down electric motor of capacity 12.5 HP from Cooling tower/Chilled water pump set/Condenser water pump sets etc., carefully from its position and servicing complete including open the motor greasing, oiling and replacing of ball bearing rusted nuts, bolts, washers refixing the same position and painting with a coat of synthetic enamel paint over a coat red oxide primer complete all as specified and directed by Engg-in-charge. | 4 | Each Job | 7,070 ₹28,280 Lowest | 7,200 ₹28,800 | 9,000 ₹36,000 |
| 10.00 | Taking down electric motor of capacity 15 HP from Cooling tower/Chilled water pump set/Condenser water pump sets etc., carefully from its position and servicing complete including open the motor greasing, oiling and replacing of ball bearing rusted nuts, bolts, washers refixing the same position and painting with a coat of synthetic enamel paint over a coat red oxide primer complete all as specified and directed by Engg-in-charge. | 4 | Each Job | 7,600 ₹30,400 | 7,500 ₹30,000 Lowest | 10,200 ₹40,800 |
Tender Value
₹29.8 L
EMD Value
₹60,000
Closing Date
31 Jul 2026, 6:00 pmClosed
AGE I RD AVADI
AGE I RD AVADI, CHENNAI
REPAIRS AND MAINTENANCE OF CENTRAL AC PLANT COOLING TOWERS DESCALING REPAIRS TO SUCTION DISCHARGE PIPE LINE CONTROL VALVES DRIVE PANELS AND REPAIRS TO LT CONTROL PANELS AND SWITCH GEARS OF AC PLANTS REPAIRS TO DUCTABLEPACKAGE TYPE AC AND ASS
2026_MES_767176_2
8758/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
AVADI
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
AGE I RD AVADI
₹60,000
Yes
8 Sept 2026
14 Jul 2026
5 Aug 2026
14 Jul 2026
31 Jul 2026
17 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Material and labour for disconnecting electrical connections, removing the defective scroll compressor three phase, 10 to13TR capacity from the mounting bed of central type Air Conditioner plant , dismantle the unit by cutting and rewinding the compressor coil with Freon resistance Super enamelled copper wire and replace bearing and worn out parts of compressor with lathe work for proper alignment with fill up of lub oil and assemble the unit , fixed in Central AC plant Testing and commissioning chiller package AC system complete. The job is inclusive of cutting, transporting brazing the suction and discharge lines by, reconnecting at site as specified and directed by Engg-in-charge.
Note : (i) Refrigerant charging will be measured and paid separately under relevant.
(ii) Rewinding will be carried out through OEM only. | 2 | Job | 10 | ₹20 |
| 2 | Material and Labour for carry out the leak test at any capacity of central AC plant refrigeration systems by charging the dry nitrogen gas & hold up to 24hrs and rectifying the leakage if any by brazing/ welding/ replacing the spare parts if any etc, complete all as specified and directed by Engg-in-charge.
Note :- The Spares measured and paid separately under respective items below. | 14 | Job | - | - |
| 3 | Material and labour for recharging R-407A/ R-410A Refrigerant gas complete all as specified and directed by Engg-in-charge. | 180 | Kg | - | - |
| 4 | Material and Labour for recharging R-22/ R-32 Refrigerant gas complete all as specified and directed by Engg-in-charge. | 120 | Kg | - | - |
| 5 | Material and Labour for descaling the shell and tube condensors as per standard practice disconnecting the pipe line connection and removing the end cover, circulating diluted hydrochloric acid by pumping into copper tubes minimum half an hour and brushing. These copper tubes to be cleaned with nylon brush for removal of dirt and scales without damaging the tubes, removal of scales from the end cover and after ensuring all dirt and scales is removed wash the tubes with clean water in minimum one hour till all dust particles, scales washed out and re-assemble the condensor unit connect the pipe line and test and ensure the condensor working properly for the capacity upto 72TR complete all as specified and directed by Engg-in-charge. | 46 | Job | 10 | ₹460 |
| 6 | Taking down electric motor of capacity 5 HP from Cooling tower/Chilled water pump set/Condenser water pump sets etc., carefully from its position and servicing complete including open the motor greasing, oiling and replacing of ball bearing rusted nuts, bolts, washers refixing the same position and painting with a coat of synthetic enamel paint over a coat red oxide primer complete for the following electric motors complete all as specified and directed by Engg-in-charge. | 4 | Each Job | - | - |
| 7 | Taking down electric motor of capacity 7 HP from Cooling tower/Chilled water pump set/Condenser water pump sets etc., carefully from its position and servicing complete including open the motor greasing, oiling and replacing of ball bearing rusted nuts, bolts, washers refixing the same position and painting with a coat of synthetic enamel paint over a coat red oxide primer complete all as specified and directed by Engg-in-charge. | 4 | Each Job | 53 | ₹212 |
| 8 | Taking down electric motor of capacity 10 HP from Cooling tower/Chilled water pump set/Condenser water pump sets etc., carefully from its position and servicing complete including open the motor greasing, oiling and replacing of ball bearing rusted nuts, bolts, washers refixing the same position and painting with a coat of synthetic enamel paint over a coat red oxide primer complete all as specified and directed by Engg-in-charge. | 4 | Each Job | 10 | ₹40 |
| 9 | Taking down electric motor of capacity 12.5 HP from Cooling tower/Chilled water pump set/Condenser water pump sets etc., carefully from its position and servicing complete including open the motor greasing, oiling and replacing of ball bearing rusted nuts, bolts, washers refixing the same position and painting with a coat of synthetic enamel paint over a coat red oxide primer complete all as specified and directed by Engg-in-charge. | 4 | Each Job | - | - |
| 10 | Taking down electric motor of capacity 15 HP from Cooling tower/Chilled water pump set/Condenser water pump sets etc., carefully from its position and servicing complete including open the motor greasing, oiling and replacing of ball bearing rusted nuts, bolts, washers refixing the same position and painting with a coat of synthetic enamel paint over a coat red oxide primer complete all as specified and directed by Engg-in-charge. | 4 | Each Job | 1.25 | ₹5 |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.60 MB
BOQ_871779.xls
BOQ • 0.47 MB
TenderDocuments.pdf
Tender Documents • 1.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .