| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.7 LAccepted-AOC VILL BHANGERI PO ROORKEE PIN 247667 | HARIDWAR | UTTARAKHAND | 247667 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹38.0 L+₹33,363.19 (0.89%)Rejected-AOC RZ 17B STREET NO 30 INDIRA PARK PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | L2 | Rejected-AOC Rejected being not L1 | |
| 3 | L3₹41.6 L+₹3.9 L (10.3%)Rejected-AOC | L3 | Rejected-AOC Rejected being not L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
29 Aug 2022, 6:00 pmClosed
GE (MES) Roorkee
Garrison Engineer (MES) Roorkee 247667
REPAIR MAINTENANCE DG SETS T P AND CONNECTED ITEMS AT ROORKEE SAHARANPUR AND PURKAZI UNDER GE ROORKEE
2022_MES_542426_1
8392/204/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Roorkee
Please refer tender documents
8 documents required · 8 mandatory
₹500
GE (MES) Roorkee
₹90,000
Yes
7 Mar 2023
1 Aug 2022
5 Sept 2022
1 Aug 2022
29 Aug 2022
15 Aug 2022
Amount
M&L for 'B' check means taking out old unserviceable engine oil from oil sump by openeing the drain plug and well cleaning the oil sump, taking out oil filter,bypass filter and diesel filter (primary and secondary) and replacement the same with new as follows for DG Set's of capacity of 250 KVA complete all as specified and directed. Make - Cummins Note : (a) Spare parts shall be measured and paid separately under respective item of Sch 'A'. (b) Labour charges for dismantling/taking down and replacement/fixing new parts as and when required deems to be incl. in the quoted rates
(a) Supply only Lubricating Oil filter element with 'O' ring.
(b) Supply only fuel filter element with 'O' ring
(c) Supply only Air filter element inner & outter
(d) Supply only 'V' belt cogged type make Fenner/good
(e) Supply only Hose pipe, including nut, bolts and clamps
(f) Supply only Oil bypass filter element with 'O' ring
(g) Supply only fuel water seprater
(h) Supply only Engine oil of grade 20W40
M&L for 'B' check means taking out old unserviceable engine oil from oil sump by openeing the drain plug and well cleaning the oil sump, taking out oil filter,bypass filter and diesel filter (primary and secondary) and replacement the same with new as follows for DG Set's of capacity of 125 KVA to 100 KVA complete all as specified and directed. Make - Cummins/Kirlosker Note : (a) Spare parts shall be measured and paid separately under respective item of Sch 'A'. (b) Labour charges for dismantling/taking down and replacement/fixing new parts as and when required deems to be incl. in the quoted rates.
(a) Supply only Lubricating Oil filter element with 'O' ring.
(b) Supply only fuel filter element with 'O' ring
(c) Supply only Air filter element inner & outter
(d) Supply only 'V' belt cogged type make Fenner/good
(e) Supply only Hose pipe, including nut, bolts and clamps
(f) Supply only Oil bypass filter element with 'O' ring
(g) Supply only fuel water seprater
(h) Supply only Engine oil of grade 20W40
M&L for 'B' check means taking out old unserviceable engine oil from oil sump by openeing the drain plug and well cleaning the oil sump, taking out oil filter,bypass filter and diesel filter (primary and secondary) and replacement the same with new as follows for DG Set's of capacity of 125 KVA complete all as specified and directed. Make -Greaves Cotton Ltd. Note : (a) Spare parts shall be measured and paid separately under respective item of Sch 'A'. (b) Labour charges for dismantling/taking down and replacement/fixing new parts as and when required deems to be incl. in the quoted rates
(a) Supply only Lubricating Oil filter element with 'O' ring.
(b) Supply only fuel filter element primary & secondery with 'O' ring
(c) Supply only Air filter element inner & outter
(d) Supply only 'V' belt cogged type make Fenner/good
(e) Supply only Hose pipe, including nut, bolts and clamps
(f) Supply only fuel water seprater
(g) Supply only Engine oil of grade 20W40
M&L for 'B' check means taking out old unserviceable engine oil from oil sump by openeing the drain plug and well cleaning the oil sump, taking out oil filter,bypass filter and diesel filter (primary and secondary) and replacement the same with new as follows for DG Set's of capacity of 62.5 KVA to 63 KVA complete all as specified and directed. Make Kirlosker/Ruston Note : (a) Spare parts shall be measured and paid separately under respective item of Sch 'A'. (b) Labour charges for dismantling/taking down and replacement/fixing new parts as and when required deems to be incl. in the quoted rates
(a) Supply only Lubricating Oil filter element with 'O' ring.
(b) Supply only fuel filter element primary & secondery with 'O' ring
(c) Supply only Air filter element inner & outter
(d) Supply only 'V' belt cogged type make Fenner/good
(e) Supply only Hose pipe, including nut, bolts and clamps
(f) Supply only fuel water seprater
(g) Supply only Engine oil of grade 20W40
M&L for 'B' check means taking out old unserviceable engine oil from oil sump by openeing the drain plug and well cleaning the oil sump, taking out oil filter,bypass filter and diesel filter (primary and secondary) and replacement the same with new as follows for DG Set's of capacity of 40 KVA to 45 KVA complete all as specified and directed. Make Ruston Note : (a) Spare parts shall be measured and paid separately under respective item of Sch 'A'. (b) Labour charges for dismantling/taking down and replacement/fixing new parts as and when required deems to be incl. in the quoted rates
(a) Supply only Lubricating Oil filter element with 'O' ring.
(b) Supply only fuel filter element primary & secondery with 'O' ring
(c) Supply only Air filter element inner & outter
(d) Supply only 'V' belt cogged type make Fenner/good
(e) Supply only Hose pipe, including nut, bolts and clamps
(f) Supply only fuel water seprater
(g) Supply only Engine oil of grade 20W40
M&L for 'B' check means taking out old unserviceable engine oil from oil sump by openeing the drain plug and well cleaning the oil sump, taking out oil filter,bypass filter and diesel filter (primary and secondary) and replacement the same with new as follows for DG Set's of capacity of 5 to 20 KVA complete all as specified and directed. Make, Kirlosker/Ruston Note : (a) Spare parts shall be measured and paid separately under respective item of Sch 'A'. (b) Labour charges for dismantling/taking down and replacement/fixing new parts as and when required deems to be incl. in the quoted rates
(a) Supply only Lubricating Oil filter element with 'O' ring.
(b) Supply only fuel filter element primary & secondery with 'O' ring
(c) Supply only Air filter element inner
(d) Supply only 'V' belt cogged type make Fenner/good
(e) Supply only Hose pipe, including nut, bolts and clamps
(f) Supply only Engine oil of grade 20W40
Dismenttling of air filter oil bath type from DG Set ,Cleaning & Repairs replacing the engine oil & minor parts complete & refixing the same all as directed.
Disconnecting, removing and dismantling water radiator assembly from DG Set of 5 KVA to 20 KVA DG set and descaling the radiator thoroughly with radiator cleaner solution/ any other chemical solvent agent as approved by Engr-In-Charge, stopping of leakage at place to copper cores and tubes by brazing scrapping the existing oil paint, dusting and painting the radiator with enameled paint etc., re-installing and commissioning complete all as specified and as directed.
All as per item No 08 above but for DG set of capacity 40 KVA to 63 KVA complete all as specified and directed.
All as per item No 08 above but for DG set of capacity 100 KVA to 125 KVA complete all as specified and as directed.
Repairs of charging alternator of 12 Volt, by removing, dismantling, replacing the unserviceable burnt rotor and stator assembly and re-fixing to the engine and testing for satisfactory charging of battery including all necessary repair complete all as specified and as directed.
All as per item No 11 above but of 24V, required for battery charching alternator complete all as specified and as directed.
Removing and replacing the old unserviceable AVR (Automatic Voltage Regulator) with new ones of the exising make of generator of capacity 125 KVA to 250 KVA, complete all as specified and directed.
All as per item No 13 above but of 63 KVA to 100 KVA complete all as specified and directed.
All as per item No 13 above but of 40 KVA to 45 KVA complete all as specified and directed.
All as per item No 13 above but of 5 KVA to 20 KVA complete all as specified and directed.
M&L for repair & overhauling the self starter assy 12 Volts by taking out from the DG set capacity 125KVA Disnmantling & cleaning , providing proper insulation rewininding armature and stator assembly with super enamelled copper wire of existing size & insulating the field coil assy replacing pinion and clutch assy & fixing back after repairs , testing on completion complete all as specified and directed.
M&L for repair & overhauling the self starter assy 24 Volts by taking out from the DG set capacity 63 /125 KVA Disnmantling & cleaning , providing proper insulation rewininding armature and stator assemblywith super enamelled copper wire of existing size & insulating the field coil assy replacing pinion and clutch assy & fixing back after repairs , testing on completion complete all as specified and directed.
M&L for repair & overhauling of the self starter assy 24 Volts by taking out from the DG set capacity 250 kvaDisnmantling & cleaning , providing proper insulation rewininding armature and stator assembly with super enamelled copper wire of existing size & insulating the field coil assy replacing pinion and clutch assy & fixing back after repairs, testing on completion complete all as specified and directed.
M&L for repair & overhauling of the self starter assy 12 volts by taking out from the DG set of capacity 63KVA/100 KVA, Disnmantling & cleaning , providing proper insulation rewininding with super enamelled copper wire of existing size & insulating the field coil assy replacing pinion and clutch assy & fixing back after repairs, testing on completion complete all as specified and directed.
M&L for repair & overhauling of the self starter assy 12 volts by taking out from the DG set any capacity below 45 KVA, Disnmantling & cleaning , providing proper insulation rewininding armature and stator assembly with super enamelled copper wire of existing size & insulating the field coil assy & replacing pinion and clutch assy & fixing back after repairs , testing on completion complete all as specified and directed.
M&L for replacement of battery terminal positive & negative made of brass with necessary brazing to cable complete all as specified and directed.
M&L for replacement of battery cable of 70 Sqmm PVC insulated multi stranded copper conductor single core cable with necessary copper lugs complete all as specified and directed.
Supply only inhabitor non corrossive coolent in 2lit/01 lit pack for Top-up, mixed with distilled water as recommended ratio complete all as specified and directed. Make : Castrol, Fleet Guard
Supply only distilled water in 5 lit packed for top up distillled water for mixing of coolent as per recommended ratio complete all as specified and directed.
Taking down dynamo 12 volt from any capacity of DG SET, from the exisintg position, dismantling the same and repairing by turning of commutator replacing the armature, carbon brush varnishing the coil reassembling the parts and refixing in position testing and commissioning complete all as specified and directed.
M&L for preparing old metal surface by cleaning, removing old paint by paint remover/scrappers for any width or girth and applying two coats of synthetic enamel paint by spray painting (second coat shall be applied at the interval of one day) of colour complete all as specified and directed for DG Sets as followings capacity :-
(a) 250 KVA DG set
(b) 100 KVA TO 125.5 KVA DG Set
(c) 40 KVA TO 63 KVA DG Set
(d) 15 KVA to 20 KVA DG Set
Taking down PT pump from engine, over hauling & calibiration at workshop, and clean with cleaning agent including replacement of defective parts by new parts reinstallation, and testing complete. for 125/250 KVA complete all as specified and directed. Note- Defective parts measured and paid separetely in respective items here in after
(a) Supply only gaskit set
(b) Supply only techo shaft assembly
(c) Supply only throttle shaft
(d) Supply only gear pump
(e) Supply only berral & sleeves
(f) Supply only governer plunger
(g) Supply only shut down valve assymbly
Taking down injector asseymbly from D G Set & neatly cleaned by cleaning agent, repair & calibiration at workshop,including replacement of defective parts by new parts ,reinstallation, and testing complete for 63 KVA to 125 KVA complete all as specified and directed. Note- Defective parts measured and paid separetely in resprctive items here in after
(a) Supply only injector cup set
(b) Supply only barrel plunger
(c) Supply only 'O' ring set
Taking down injector asseymbly from D G Set & neatly cleaned by cleaning agent, repair & calibiration at workshop,including replacement of defective parts by new parts ,reinstallation, and testing complete for 5 KVA to 20 KVA complete all as specified and directed. Note- Defective parts measured and paid separetely in resprctive items here in after
(a) Supply only injector cup set
(b) Supply only barrel plunger
(c) Supply only 'O' ring set
Taking down turbo charger assembly from 250 KVA DG set Repair / over hauling including replacement of defective parts by new parts ,reinstallation, and testing for 250 KVA DG Set complete all as specified and directed. Note- Defective parts measured and paid separetely in resprctive items here in after
(a) Supply only Terbo repair kit
(b) Supply only Terbine wheel & shaft
(c) Supply only compressor wheel
All as per item No. 31 above but 125 KVA DG set complete all as directed.
(a) Supply only Terbo repair kit
(b) Supply only Terbine wheel & shaft
(c) Supply only compressor wheel
All as per item No. 31 above but 63 KVA DG set complete all as directed.
(a) Supply only Terbo repair kit
(b) Supply only Terbine wheel & shaft
(c) Supply only compressor wheel
Supply & Fixing Asbestos rope suitable for silencer of DG Set as directed
Taking down of AC alternator from DG sets of capacity 5 KVA to 20 KVA after disconnecting all electrical connections, cleaning of winding with emery paper of armature and filled coils, including transportation of alternator to workshop and bringing back to site for re-installation and reconnecting alternator with engine including testing on load complete all as specified and as directed including repairing of following worn out spare parts : - (i) Carbon bushing and brush holder (set of 08) - 01 Set. (ii) Suitable size and capacity of bearing - 01 Set.
All as per item No. 35 above but 40 to 63 KVA DG set complete all as specified and directed.
All as per item No. 35 above but 100 to 125 KVA DG set complete all as specified and directed.
Taking down of FIP from engine,repair overhaulling,calibration and testing of fuel pump of 20 KVA to 40 KVA capacity DG set including replacement of defective parts , and adjustment of injectors and setting of fuel pressure complete all as specified and as directed.
(a) Supply only delivery valve
(b) Supply only roller
(c) Supply only rocker asssambly
(d) Supply only element
(e) Supply only FIP gasket set
All as per item No. 38 above but, 62.5 KVA to 63 KVA DG set complete all as specified and directed.
(a) Supply only delivery valve
(b) Supply only roller
(c) Supply only rocker asssambly
(d) Supply only element
(e) Supply only FIP gasket set
All as per item No. 38 above but 100KVA to 125 KVA DG set complete all as specified and directed.
(a) Supply only delivery valve
(b) Supply only roller
(c) Supply only rocker asssambly
(d) Supply only element
(e) Supply only FIP gasket set
Supply & fixing in replacement shut down valve assymbly complete all as specified and directed.
Supply & fixing vaccume indicator complete all as specified and directed.
Supply & fixing rubber hose cooler any size complete all as specified and directed.
Supply & fixing Hose rubber for radiator any size complete all as specified and directed.
Supply & fixing fuel pipe from tank to filter with all fittings complete all as specified and directed.
Supply & fixing fuel pipe from filter to pump assymbly with all fittings complete all as specified and directed.
Supply & fixing water pump assymbly suitable for 62.5 KVA DG Set complete all as specified and directed.
Supply and fix in replacement 'ON LOAD' change over switch 415V in sheet metal enclosures 4 pole of capacity 63 Amps with side handle operated complete all as specified and as directed.
Supply and fix in replacement 'ON LOAD' change over switch 415V in sheet metal enclosures 4 pole of capacity 160 Amps with side handle operated complete all as specified and as directed.
Supply and fix in replacement 'ON LOAD' change over switch 415V in sheet metal enclosures 4 pole of capacity 200 Amps with side handle operated complete all as specified and as directed.
Supply and fix in replacement 'ON LOAD' change over switch 415V in sheet metal enclosures 4 pole of capacity 630 Amps complete all as specified and as directed.
Supplying and laying in replacement synthetic Rubber insulated mats 20 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m. complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode size 600 x 600 x 6mm thick burried directly in ground vertically in a pit of depth not less than 2.25 mtr belwo ground levels with top edge of the earh plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised iron strip 32x6mm earth lead by means ofbolts, nuts, check nuts and washers of galvanised steel all as shown in electric plate No. of SSR Part-I connected to continuous earth wire on main switch board all as specifed or indicated and testing on completion including
provision of earth strip protection with 40 mm dia medium grade GI Pipe and watering pipe shall be 20mm bore, medium grade including provision of PCC chamber with PCC 1: 2:4 type B -1 (using 20 mm graded stone aggregate) as in pit chamber and RCC pit cover 50 mm thick precast RCC 1:2:4 type B-1 duly reinforced with MS round bars 6 mm dia at the rate of 100 mm C/C both ways with 10mm dia MS round bar as in lifting handles excavation earth work including laying the GI pipe concealed in floor/ wall all as described in electric plate No 3 of SSR Part I , complete all as specified and directed. Note ; The unit rate includes for protection pipe and GI strip from top of earth plate upto 7.5m above ground level.
S&F in repair of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required GI strip 32x6 mm complete all as specified and directed.
Disconnecting carefully old unserviceable ammeter from panel board and S&F of new 96mm size square/circular digital type ammeter of range 0-30 ampere or 0-300 Ampere, size of letters 25mm, with set of CTs of suitable rating, necessary connectiong/fixing arrangements and testing complete all as specified and directed. make AE or Equivalent
Disconnecting carefully old unserviceable Voltmeter from panel board an S&F of new 96 mm size square/circular digital type Voltmeter of range 0-500 Volt,size of letters 25mm, make -AE (ISI marked), necessary connecting/fixing arrangements and testing complete all as specified and directed
S&F as in replacement of LED type indicating lamps of RYB colours as directed at site on existing panel board including necessary fixing and connecting arrangements complete all as specified and directed
M &L for reconditioning of unserviceable battery 12 volt, 120 to 180 Ah by replacing complete cells, PVC saperaters, electrolyte, terminals & final sealing, recharging and testing complete all as specified and directed.
Supply and fixing in replacement of U/S batery with new 12 volts150 AH lead acid tubular battery complete all as specified and directed. Make- Exide, Amron/ Livefast
Supply and fixing in replacement of U/S batery with new 12 volts 92 AH lead acid tubular battery complete all as specified and directed. Make- Exide, Amron/ Livefast
S & F in replacement of old unserviceable LED Post Top Lantern light fitting 40 watt capacity with transperent diffuser and fixing arrangement on including GI Pipe light grade of dia 40 mm duely grouted on wall/brick pillar complete all as specified and directed at siteand electrical connection from junction box to light fitting complete all as specified and directed. Make: C&S Cat .LTGLM40WHPLED/W or any equivalent model in Havells/Philips/Wipro.
M & L for refilling of fire extinguishers of capacity 9 Kg foam / ABC type complete all as specified and directed.
M & L for refilling of fire extinguishers of capacity 5 Kg foam / ABC type complete all as specified and directed.
M & L for refilling of fire extinguishers of capacity 2 Kg foam / ABC type complete all as specified and directed.
S&F antivibration pad suitable for 250 KVA DG Set,125 KVA DG Set and 63 KVA DG Sets for mounting DG Sets including removing broken hinges and making good surface for fixing in new hinges compatible for closing and opening and greasing thereafter, complete all as specified and directed
S&F in replacement of glow sign board box type of size 120 cm x 300cm of acrylic sheet cover in sky blue colour one side display and GI Sheet for back side and made of MS angle frame not less than 40x40x6mm with 02 x LED tube light fittings complete including connecting up with twin core twisted flexible copper conductor cable with suitable size and necessary items for fixing on roof of Pump House & Power House and stnecil of word as reqd with all grouting and PCC work complete all as specified and as directed
Inreplacement,Supply, fabrication, installation, testing and commissioning, cubical type LT indoor panel, dust vermin proof ,front operated type CPRI approved , made out of f 2.00 mm thick CRCA sheet , of suitable size complete wiring copper bus bar chamber cable alley, cable glandes brass cromine plated of different sizes suitable for incomming and out going MCCB's panel with powder coated paint and all as specified for following items:- (FOR 250 KVA DG SET)
(a) Copper busbar of capacity 1200 Amps with epoxy insulated supports 3 phase and neutral -01 set Incommer (b) ON LOAD type front operated C/O switch , 630 A, 4 pole ,415V AC -01 No (c) MCCB 400 A, 4 pole 36 KA MCCB with adjustable thermal and magnatic setting including extendable link -01 No (spair ) Out going feeders: (d) Out going MCCB 32 Amps 25 KA 3 pole-01 Nos (for bldg light) (e) Multifunction meter model MIM 10 type 96 sqmm,sutable for measuring of VAF -01 set (f) Indication lamp set LED type -01 set
Inreplacement,Supply, fabrication, installation, testing and commissioning, cubical type LT indoor panel, dust vermin proof ,front operated type CPRI approved , made out of f 2.00 mm thick CRCA sheet , of suitable size complete wiring copper bus bar chamber cable alley, cable glandes brass cromine plated of different sizes suitable for incomming and out going MCCB's panel with powder coated paint and all as specified for following items:- (FOR125 KVA DG SET)
(a) Copper busbar of capacity 400 Amps with epoxy insulated supports 3 phase and neutral -01 set Incommer (b) ON LOAD type front operated C/O switch , 200 A, 4 pole ,415V AC -01 No (c) MCCB 200 A, 4 pole 36 KA MCCB with adjustable thermal and magnatic setting including extendable link -01 No Out going feeders: (d) MCB DP 32 Amps 02 Nos (e) Multifunction meter model MIM 10 type 96 sqmm,sutable for measuring of VAF -01 set (f) Indication lamp set LED type -01 set
Inreplacement,Supply, fabrication, installation, testing and commissioning, cubical type LT indoor panel, dust vermin proof ,front operated type CPRI approved , made out of f 2.00 mm thick CRCA sheet , of suitable size complete wiring copper bus bar chamber cable alley, cable glandes brass cromine plated of different sizes suitable for incomming and out going MCCB's panel with powder coated paint and all as specified for following items:- (FOR PUMP HOUSE -VT PUMPS 35 HP, Pump House No-1,3)
(a) Copper busbar of capacity 400 Amps with epoxy insulated supports 3 phase and neutral -01 set Incommer (b) ON LOAD type C/O switch ,160 A, 4 pole ,415V AC -01 No (c) MCCB 125 A, 4 pole 36 KA MCCB with adjustable thermal and magnatic setting including extendable link -01 No Out going feeders: (d) Out going MCCB 100 Amps 36 KA 4 pole-0 2Nos (e) MCB DP 32 Amps 02 Nos (f) Multifunction meter model MIM 10 type 96 sqmm,sutable for measuring of VAF -01 set (g) Indication lamp set LED type -02set (h)ML FASD Starter, 3 phase 415 V,50Hz,complete with all assassories & inluding OCR protection relay suitable for 35 HP Pump/Motor - 02 Nos (j) PCC plateform length & width as per requirement 450mm high, 300mm above ground level and 150mm below ground level, plastered, painted with two coats of cement base paint white and centre portion filled with dry fine sand, four Nos bolts grouted for fixing panel -01 job
Inreplacement,Supply, fabrication, installation, testing and commissioning, cubical type LT indoor panel, dust vermin proof ,front operated type CPRI approved , made out of f 2.00 mm thick CRCA sheet , of suitable size complete wiring copper bus bar chamber cable alley, cable glandes brass cromine plated of different sizes suitable for incomming and out going MCCB's panel with powder coated paint and all as specified for following items:- (FOR PUMP HOUSE -VT PUMPS 50 HP )
(a) Copper busbar of capacity 400 Amps with epoxy insulated supports 3 phase and neutral -01 set Incommer (b) ON LOAD type C/O switch ,200 A, 4 pole ,415V AC -01 No (c) MCCB 125 A, 4 pole 36 KA MCCB with adjustable thermal and magnatic setting including extendable link -01 No Out going feeders: (d) Out going MCCB 100 Amps 36 KA 4 pole-0 2Nos (e) MCB DP 32 Amps 02 Nos (f) Multifunction meter model MIM 10 type 96 sqmm,sutable for measuring of VAF -01 set (g) Indication lamp set LED type -02set (h)ML FASD Starter, 3 phase 415 V,50Hz,complete with all assassories & inluding OCR protection relay suitable for 50 HP Pump/Motor - 02 Nos (j) PCC plateform length & width as per requirement 450mm high, 300mm above ground level and 150mm below ground level, plastered, painted with two coats of cement base paint white and centre portion filled with dry fine sand, four Nos bolts grouted for fixing panel -01 job
Supply and laying along the pole/pipe or passing through pipe or laid underground/floor through walls etc, jointing and testing XLPE insulated galvanised steel wire armoured electric cable 1100V grade heavy duty ISI marked with Aluminium conductor of cross sectional area 240 sqmm 3.5 core complete all as specified and as directed.
All as per item No. 71 above but of size 120 sqmm 3.5 core
All as per item No. 71 above but of size 95 sqmm 3.5 core
All as per item No. 71 above but of size 6 sqmm 2 core
M&L of GI pipe light grade 100 mm dia for cable protection including cold drilling and making good surface as per existing complete all as specified and directed.
M&L of GI pipe light grade 40 mm dia for cable protection including cold drilling and making good surface as per existing complete all as specified and directed.
Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M depth in any type of soil and getting out for laying GI strip conductor, stay, poles etc complete all as specified and directed.
Returning, filling in including spreading laveling, watering and well ramming in layers not exceeding 25cm in any type of soil complete all as specified and directed.
Removing excavated material n.exc. 50M and depositing where directed at a level n.exc. 1.5M above the starting points complete all as specified and directed.
Supply and spread unwashed dry river sand for sand cushioning and covering the UG Cable in trenches complete all as specified and directed. (Note : Punning thickness (18cm) shall be measured)
Supply & lay in trenches sub class `B’ bricks having compressive strength 75 Kg/ Sqcm for cable protection etc compete all as specified and directed by Engineer-in-Charge.
SAHARANPUR
M&L for 'B' check means taking out old unserviceable engine oil from oil sump by openeing the drain plug and well cleaning the oil sump, taking out oil filter,bypass filter and diesel filter (primary and secondary) and replacement the same with new as follows for 63 KVA DG Set (Make :Kirloskar) Engine No.4H3445/120542, Machine No.JC/WC/6205/SIL/867K, Alternator No. ES3AO13B165088 at Pump House No.4 at RTS& Depot Saharanpur including testing and commissioning complete all as specified and directed. Note : (a) Spare parts shall be measured and paid separately under respective item of Sch 'A'. (b) Labour charges for dismantling/taking down and replacement/fixing new parts as and when required deems to be incl. in the quoted rates
(a) Supply only of lubricating Oil filter element with seal
(b) Supply only of Fuel filter element with seal
(c) Supply only of Air filter element
(d) Supply only of 'V' belt make Funnder/good year (4PK-1158 EPDM Poly 'V' Belt)
(e) Supply only of Hose pipe, including nut, bolts and clamps
(f) Supply only Oil bypass filter element with seal
(g) Supply only lubricating oil, grade 15W40 (K-oil premium)
(h) Supply only inhibitor non corrosive coolant including mixed with distilled water as recommended ratio Make :cummins
M&L for 'B' check means taking out old unserviceable engine oil from oil sump by openeing the drain plug and well cleaning the oil sump, taking out oil filter,bypass filter and diesel filter (primary and secondary) and replacement the same with new as follows for 30 KVA DG Set (Make :Kirloskar) Engine No.3H3025/1320572, Machine No.JKWL/30/SIL/8363K, Alternator No. 653C013B2506H at Pump House No.2 and at Cl-I hospitalat RTS& Depot Saharanpur including testing and commissioning complete all as specified and directed. Note : (a) Spare parts shall be measured and paid separately under respective item of Sch 'A'. (b) Labour charges for dismantling/taking down and replacement/fixing new parts as and when required deems to be incl. in the quoted rates
(a) Supply only of lubricating Oil filter element with seal
(b) Supply only of Fuel filter element with seal
(c) Supply only of Air filter element
(d) Supply only of poly 'V' belt make Funnder/good year for 3H3025 Model, part No 4H 1493.01.0.00 in user manual of Kirloskar
(e) Supply only of 'V' belt make Funner/good year A-55
(f) Supply only of Hose pipe, including nut, bolts and clamps
(g) Supply only Oil bypass filter element with seal
(h) Supply only lubricating oil,cgrade 15W40 (K-oil premium)
(j) Supply only inhibitor non corrosive coolant including mixed with distilled water as recommended ratio Make :cummins
M&L for 'B' check means taking out old unserviceable engine oil from oil sump by openeing the drain plug and well cleaning the oil sump, taking out oil filter,bypass filter and diesel filter (primary and secondary) and replacement the same with new as follows for 20 KVA DG Set (Make :Kirloskar) Engine No. 03-1013/88169 , Alternator No.88PH20-60 at Foaling Line at RTS& Depot Saharanpur including testing and commissioning complete all as specified and directed. Note : (a) Spare parts shall be measured and paid separately under respective item of Sch 'A'. (b) Labour charges for dismantling/taking down and replacement/fixing new parts as and when required deems to be incl. in the quoted rates
(a) Supply only of lubricating Oil filter element with seal
(b) Supply only of Fuel filter
(c) Supply only of Air filter element element with seal
(d) Supply only of 'V' belt make Funnder/good year A-44
(e) Supply only of 'V' belt make Funner/good year A-55
(f) Supply only of Hose pipe, including nut, bolts and clamps
(g) Supply only Oil bypass filter element with seal
(h) Supply only fuel line as per existing size or around 2 mtr long complete all as specified
(J) Supply only lubricating oil, grade 15W40 (K-oil premium)
S&F in repair brass battery terminal heavy duty complete suitable for 12 volts Battery.
S&F PVC insulated multistranded copper wire lead for connecting battery of size 25 Sqmm complete all as directed
Supply & pouring of distilled water in batteries complete all as specified and as directed.
M&L for preparing old metal/wooden surface by cleaning, removing old paint by paint remover/scrappers for any width or girth and applying two coats of synthetic enamel paint by spray painting (second coat shall be applied at the interval of one day) of colour complete complete all as specified and directed for the following items :- .
(a) 150 mm CI/GI Pipe line
(b) Gate valves and gate valve chamber (metal) doors
(c) Shutters for sub stations and pump houses
(d) Vertical Turbine Pumps (external body)
(e) Doors incluindg glazed door frames
(f) Windows
M&L for preparing old metal surface by cleaning, removing old paint by paint remover/scrappers for any width or girth and applying two coats of synthetic enamel paint by spray painting (second coat shall be applied at the interval of one day) of colour as directed by EIC etc. complete all as specified and directed for DG Set 20 KVA Capacity
Disconnecting carefully old unserviceable ammeter from panel board and S&F of new 96mm size square/circular digital type ammeter of range 0-30 ampere or 0-100 Ampere, size of letters 25mm, with set of CTs of suitable rating, necessary connectiong/fixing arrangements and testing complete all as specified and directed. make AE or Equivalent
Disconnecting carefully old unserviceable Voltmeter from panel board and S&F of new 96 mm size square/circular digital type Voltmeter of range 0-500 Volt,size of letters 25mm, make -AE (ISI marked), necessary connecting/fixing arrangements and testing complete all as specified and directed
S&F as in replacement of LED type indicating lamps of RYB colours as directed at site on existing panel board including necessary fixing and connecting arrangements complete all as specified and directed
M&L in repair of test terminal block made of gun metal or phosphorus bronze size 75 x 7 5x 25 mm incl 3 nos, 8 mm ida 25mm long hex. Head screw complete all as specified and as directed
S&F in repair of Earth continuity conductor aluminium strip 25 x 3mm with saddles and fixing screws etc in wall all complete as specified and directed
M&L for earthing complete with galvanised steel earth plate electrode size 600 x 600 x 6mm thick burried directly in ground vertically in a pit of depth not less than 2.25 mtr belwo ground levels with top edge of the earh plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised iron strip 32x6mm earth lead by means ofbolts, nuts, check nuts and washers of galvanised steel all as shown in electric plate No. of SSR Part-I connected to continuous earth wire on main switch board all as specifed or indicated and testing on completion including provision of earth strip protection with 40 mm dia medium grade
GI Pipe and watering pipe shall be 20mm bore, medium grade including excavation and earthwork in any type of soil & disposal of soil, provision of PCC chamber with PCC 1: 2:4 type B -1 (using 20 mm graded stone aggregate) as in pit chamber and RCC pit cover 50 mm thick precast RCC 1:2:4 type B-1 duly reinforced with MS round bars 6 mm dia at the rate of 100 mm C/C both ways with 10mm dia MS round bar as in lifting handles excavation earth work including laying the GI pipe concealed in floor/ wall all as described in electric plate No 3 of SSR Part I , complete all as specified and directed. Note ; The unit rate includes for protection pipe and GI strip from top of earth plate upto 7.5m above ground.
S&F in repair of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required GI strip 32x6 mm complete all as specified and directed.
Supply in replacement 12 volts 150 ampere hour Dry type battery sealed maintenance free for power pack of 11KV VCB complete all as specified and directed. Make : Amron/Exide/Luminous
S&F in replacement of 1100 volts grade heavy duty cable PVC insulated alumium conductor multistranded served with innter sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulated hangers not more then 1 meter a part including 4 mm dia GK suspension wire one twin core cable flat or circular 6 Sqmm 2 core complete all as specified and directed.
S&F in replacement of glow sign board box type of size 100 cm x 200cm made of flexy cover in blue and maroon bordering colour all around the flex board in rectangular form, blue background with MES logo on the centre with the stencil of word, font size as directed by Engr-in-Charge. One side of the board will display and the other side is made of GI Sheet with MS angle frame not less than 40x40x6mm, 02 x LED tube light fittings complete including connecting up with twin core twisted flexible copper conductor cable with suitable size and necessary items for fixing on roof of Pump House & Power House, with all grouting and PCC work complete all as specified and as directed
Supply only class 2 electrical hand gloves HT 11 KV complete conforming to IS :4770/1991,complete all as specified and directed.
Taking down unserviceable security light fittingsSupply and fixing new generation energy saving & environment friendly, powder coated pressure die-cast aluminium IP65 roadway luminaries with LEDs with lens as light source & exclusively designed along with electronic driver type street light fitting suitable for 60 watt capacity LED lamp with and including all accessories duly pre-wired, fixing on existing bracket and taking down the unserviceable light to store at site for street light on LT pole/ wall complete including taking old street light fitting any type and description complete all as specified and directed. Make: Havells/Crompton/Phillips.
Taking down unserviceable security light fittingsSupply and fixing new generation energy saving & environment friendly, powder coated pressure die-cast aluminium IP65 roadway luminaries with LEDs with lens as light source & exclusively designed along with electronic driver type street light fitting suitable for 35 watt capacity LED lamp with and including all accessories duly pre-wired, fixing on existing bracket and taking down the unserviceable light to store at site for street light on LT pole/ wall complete including taking old street light fitting any type and description complete all as specified and directed. Make: Havells/Crompton/Phillips
Supply and fix in replacement of GI tubing medium grade 40 mm dia ring with cap of HT pole including welding of flat iron 40mm x 5mm thick -04Nos including holes for suitable fixing of flood lights and painted with one coat of red oxide and two coats of synthetic enamel paint with clamps, bolts, nuts and whashers for fixing on poles, complete all as specified and directed.
Supply and erection of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts , nuts and screw as specified of type 410 SP-31, 9 Meter long, including marking alternate yellow and black strips 30 cm height- total-5Nos with two coats of aluminium paint over a coat of zinc chrome primer above embedded portion at GL, complete all as specified and directed. (Note. Earth work and PCC for foundation channels, clamps, nuts and bolts to be measured and paid for separately)
M&L for plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundation of stay assembly etc including necessary form work, complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for coping around poles, including necessary form work finishing even and smooth without using extra cement, complete all as specified and directed.
M&L for plain cement concrete 1:4:8 concrete D-2 using 40mm graded stone aggregate in foundation filling and mass concrete,for bedding of pole, complete all as specified and directed.
M & L in replacement DK Thermoplastic cable junction boxes IP 65 with metric knockouts for cable entry, weather proof for outdoor installation including glands and with 4 terminals for terminating one incoming and outgoing UG cable of size 10/16 Sqmm 2/4 core and fixed to the PSC/Steel Poles by means of suitable size of clamps with nut ,bolts and including provn for fixing 01 no of single pole MCBs 6-32 amps,10KA and MCB TPN 6-32 amps, 10 KA, ‘B’ series = 01 No inside the box complete all as specified and directed. Make :- Sintex/Hensel/standard or equivalent.
S&L XLPE insulated armoured heavy duty electric cable with stranded aluminum conductor 1100 volt grade cross sectional area 10 Sqmm and 2 core all as specified and directed
S&F XLPE insulated, armoured heavy duty electric cables with aluminium conductor, 1100 volts grade, cross-sectional area 70 sqmm, 3.5 core complete all as specified and directed at site by Engr-in-Charge
M&L for laying GI tubing light grade 40 mm dia with all fittings for cable protection including GI clamps nut bolts and washer etc all as specified.
Excavation over in trenches in soft/loose soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cables, poles/stays and struts etc and getting out including trimming sides and forming bottom surface all as specified and directed at site.
Removal of excavated materials n.exec 50 mtr and depositing where directed at level n.exec 1.5 mtr above the starting point
Returning, filling in including spreading, leveling, watering and well ramming excavated hard/soft in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested, poles, stays , struts have been erected and tested , complete all as specified and directed.
Supply and spread unwashed dry river sand for sand cushioning and covering the UG Cable in trenches complete all as specified and directed. (Note : Punning thickness (18cm) shall be measured)
Supply and laying burnt bricks sub class 'B' old size for cable protection laid length wise perpendicular to the axis of cable complete all as specified.
M&L for stringing in replacement of steel wire 4 mm dia 8 SWG as continuous earth wire and grading incl cradal hexagonal binding properly with channel/Angles etc complete all as specified
S&F Anticlimbing devices. Comprising of 2.24mm dia galvanised steel 2 stranded barbed wire with 2.0 mm dia barbs wrapped spirally round poles to a length of 0.5 to 1.0 mtr clamped and properly screwed complete all as specified and directed.
Electric shock treatment chart with pvc frame as per sample of size 750x480mm complete all as specified and directed.
Supply and labour for spreading stone aggregate of size 40mm at 11 KV sub station/Transformer/panel board/two pole/four pole structure area, complete all as specified and directed.
S&F in replacement of Gate lights/post top light with 15 Watt LED light as light source, IP-65, made of spun aluminium landscape luminaire suitable for fixing on 40/50 mm GI pipe on the gate post including connection with all necessary accesssories complete all as specified and directed by Engr-In-Charge.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for ducting and for finding of the cable fault in HT/LT underground cable and returning filling (including old bricks and sand) the same after rectification of the cable fault in any type of soil complete all as specified and directed
M&L for cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in cills, copings, sides of tiled path, bed blocks for hold fast, kerbs and similar work with fair faces including necessary form work, weathering, slightly rounded or chamfered angles and throating etc complete all as specified and directed.
S&F mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for precast RCC (1:2:4) type B1(using 20 mm graded stone aggregate as in cover slabs (for manholes etc) with plain faces, set in cement mortar (1:6) complete all as specified and directed.
M&L Rendering 15 mm thick on fair face on brick work in CM 1:4, finished even and smooth without using extra cement complete all as specified and directed.
M&L for brick work with old size sub class ‘B’ bricks in cement mortar (1:4), straight or curved on plan exc 6m mean radius complete all as specified and directed.
sumit associates
TRINITY CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .