GE ALWAR
GE ALWAR
REPAIR / MAINTENANCE OF FANS AND ELECTRIC METERS UNDER GE ALWAR
2021_MES_428591_1
8992/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
ALWAR
AS PER NIT
3 documents required · 3 mandatory
₹500
GE ALWAR
₹33,500
Yes
4 May 2021
6 Mar 2021
7 Apr 2021
6 Mar 2021
5 Apr 2021
22 Mar 2021
6 Mar 2021 - 20 Mar 2021
Amount
M&L for rewinding, overhauling and servicing of ceiling fan of size 48" (1200mm) sweep, 230 volt, 50 C/S, AC by dismantling the fan, taking out existing stator, removing of burnt winding from stator and rewinding the same with super enamelled copper winding wire of same gauge, same weight & turns including varnishing of winding, oiling of bushes and greasing of bearings, reassembling, cleaning, testing and repair the fan including S&F necessary minor spares/items like PVC insulated copper wire of required size, screw, nuts, bolts, spring washer etc and reassembling, cleaning, painting, numbering and testing all as specified and directed by Engineer-in-Charge. Note :- Repairable fans shall be collected by the contractor from the E/M fan store and shall be deposited to E/M store after necessary repairs. Necessary transportation charges shall be deemed to be included in the quoted rate and to be paid by the contractor to the transort agency.
All as per serial item No 1.00 & 1.01 here-in-above but ceiling fan of size 56" (1400mm) sweep.
All as per serial item No 1.00 & 1.01 here-in-above but Exhaust fan of size 18" (450mm) sweep.
All as per serial item No 1.00 & 1.01 here-in-above but Exhaust fan of size 12" (300mm) sweep.
All as per serial item No 1.00 & 1.01 here-in-above but Exhaust fan of size 9" (230mm) sweep.
All as per serial item No 1.00 & 1.01 here-in-above but wall mounted fan of any size.
Supply only following accessories / spares of ceiling fan / Exhaust fans /wall mounted fan :-
Fan capacitor 2.5 Mfd 230/240V AC, 50 HZ ISI marked all as directed. Make : Havells / Epcos / L&T as approved by GE.
Fan capacitor 4 Mfd 400/440V AC, 50 HZ ISI marked, all as directed. Make : Havells / Epcos / L&T as approved by GE.
Gun Metal bush (Make – NSP) suitable size for ceiling fans of any make and any size.
Ball bearing No 112/6201, all as directed. Make : NBC / SKF as approved by GE.
Ball bearing No 115/6202, all as directed. Make : NBC / SKF as approved by GE.
Ball bearing No 117/6203, all as directed. Make : NBC / SKF as approved by GE.
Ball bearing No 117/6204, all as directed. Make : NBC / SKF as approved by GE.
Fan regulator electronic rotary step type and socket module suitable for ceiling fan of sweep 1200/1400 mm complete all as specified and directed by Engineer-in-Charge.
‘H’ clamp complete with rubber real, bolt nut & split pin
Blade screw (SS type) suitable for 48" sweep ceiling fan (As per sample kept in GE’s Office)
Upper & lower canopy (PVC) suitable for 1200mm/1400mm ceiling fan (Set of 2, i.e. upper & lower) of Make : Crompton / Kessells / GEC / Orient / Usha as approved by GE.
Fan Blade suitable for 48" sweep ceiling fan (As per sample kept in GE’s Office)
Insulation adhessive tape roll (20m long)
S&F in repair steel shaft suitable for ceiling fan/exhaust fan/wall mounted fan of any make/model and sweep with necessary works like cutting, grouting, lathing finishing etc all as specified and directed by Engineer-in-Charge.
M&L for painting / marking SM No/ MES No on ceiling fan and exhaust fan using on coat enamelled paint complete all as per directed by Engineer-in-Charge.
Disconnecting and taking down carefully existing electric energy meter of any capacity including removing of electric connections and depositing the electric energy meter in store yard of AGE E/M, all as directed.
Fixing only tamper proof electronic energy meter (AC Static kWh meter) with LCD Display, Single Phase, ISI marked, 10 to 60 Amps (Measures & display KWh, V, KW, PF, Last month history of KWh, MD in KW), 240 Volts, AC, 50 Hz, power consumption less than 1 watt, Class 1 accuracy as per IS : 13779, starting current 0.4% of basic current, overload capacity 400% of basic current for direct reading, with special features like TOD, tamper looging, optical communication port & display in absence of power, projection mounted type, fixed in & including appropriate size pilfer proof meter box i.e. meter cupboard (complying to IS:14772) with hinge type locking arrangement moulded in transparent engineering plastic with sealable provisions and making connections with existing DBs/Sub main and providing seal with sealing wire & lead seal and testing of meter including writing MES No & Qtr No on energy meter with thicker white synthetic enamel paint, complete, all as specified & directed. Make :- L&T / HPL / SECURE as approved by GE. Note :- Tamper proof electronic energy meter shall be issued under Schedule ‘B’ free for fixing only.
Fixing only tamper proof electronic energy meter (AC Static kWh meter) with LCD Display, Three Phase, ISI marked, 10 to 60 Amps (Measures & display KWh, V, KW, PF, Last month history of KWh, MD in KW), 3X 240 Volts, AC, 50 Hz, power consumption less than 1 watt, Class 1 accuracy as per IS : 13779, starting current 0.4% of basic current, overload capacity 400% of basic current for direct reading, with special features like TOD, tamper looging, optical communication port & display in absence of power, projection mounted type, fixed in & including appropriate size pilfer proof meter box i.e. meter cupboard (complying to IS:14772) with hinge type locking arrangement moulded in transparent engineering plastic with sealable provisions and making connections with existing DBs/Sub main and providing seal with sealing wire & lead seal and testing of meter including writing MES No & Qtr No on energy meter with thick white synthetic enamel paint, complete, all as specified & directed. Make :- L&T / HPL / SECURE as approved by GE. Note :- Tamper proof electronic energy meter shall be issued under Schedule ‘B’ free for fixing only.
Supply and fixing in repairs single core PVC insulated and unsheathed multistranded copper conductor FRLS cable of size 6 Sqmm of 1100 Volt grade (ISI marked, IS: 694) drawn into and including PVC flexible pipe of suitable size fixed on surface of walls/ceiling to provide connection from electronic energy meter to distribution board and main cable connection to electronic energy meter, complete, all as specified & directed.
Supply and fixing in repairs PVC connection clamp to electric connection for ceiling fans complete all as specified and directed.
S&F in repair PVC insulated FRLS cable of size 0.5 sqmm (23/0.0076) and connecting from ceiling rose to ceiling fan complete all as specified and directed.
SANWARIA ENTERPRISES
M/s Yash Electrical and Maintenance
Shiv Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .