Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.4 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹13.1 L+₹37,466 (2.95%)Rejected-AOC E 27 CWE WELLINGTON | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹14.2 L+₹1.4 L (11.3%)Rejected-AOC NO 12 25 26 KATHIRAVAN NAGAR MAHALINGAPURAM PO POLLACHI COIMBATORE 642 002 | COIMBATORE | TAMIL NADU | 642002 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹14.9 L+₹2.2 L (17.5%)Rejected-AOC N A | L4 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹33,000
Closing Date
13 Feb 2023, 6:00 pmClosed
Shri DC Sharma IDSE CWE(NW) KOCHI
CWE(NW) KOCHI
COMPREHENSIVE MAINT OF DG SET AND FIRE FIGHTING SYSTEM, REPAIR AND MAINT OF LED STREET LIGHT, FLOOD LIGHT, GATE LIGHT AND OTHER CONNECTED ITEMS AT INS AGRANI, COIMBATORE
2022_MES_569108_2
CWE(NW)/KOCHI/81334
Open Tender
Civil Works
Item Rate
240 days
KOCHI
As per NIT
7 documents required · 7 mandatory
₹500
AGE(I) Agrani
₹33,000
Yes
24 Mar 2023
23 Jan 2023
15 Feb 2023
23 Jan 2023
13 Feb 2023
30 Jan 2023
Amount
Taking down the unserviceable street light/Flood light/Post top lantern/ Garden light fittings of any type (HPSV.HPMV,CFL,Tube light/Metal Halide fitttings )/wattage from its original location by unscrewing the nuts,bolts,washers etc and making good the disturbed surfaces complete all as specified and directed.
Supply and fix in repair high performance LED street light 40 Watt housing made of die cast aluminium with street optic LENS for uniform light distribution Rated IP-66 complete all as specified and directed . Make:Wipro cat part No. LR02-451-XXX-57-G1 or BRP 409 LED 40 CW MR FG S1 PSU GR of make Philips equivalent make in list of manufactures
Supply and fix in repair high performance LED street light 60 watt contemporary designed housing made of die cast aluminium with street optic LENS for uniform light distribution rated IP_66 complete all as specified and directed. Make:Wipro cat part No. LR02-671-XXX-57-G3 or cat part no. BRP 410 LED 060 CW HE NR PC S1 PSU GR of make Philips or equivalent make in list of manufactures
Supply and fix in repair high performance LED street light 92 watt contemporary designed husing made of die cast aluminium with street optic LENS for uniform light distribution rated IP_66 complete all as specified and directed. Make:Wipro cat part No. LR02-102-XXX-57-G2 or equivalent make in list of manufactures
Supply and fix in repair post top 20 watt pure polyester UV resistant powder coated die cast aluminium housing with PMMA clear diffuser for uniform illumination complete all as specified and directed. Make : Wipro Cat part No. LP07-251-XXX-57-CL or equivalent make in list of manufactures
Supply and fix in repairs LED flood light 210 watt aluminium die cast aluminium housing luminaire with unique lens system for enhanced uniform illumination and toughened glass with silicon gasket for IP-66 protection complete all as specified and directed. Make : Wipro cat Part No. LF30-272-060-57-XX or equivalent in Philips / GE.
Supply and fixing in repairs LED uniflood is an integral flood light 35 watt with driver inside a PDC housing, it is highly efficient reliable and sturdy compared to similar LED halogen & metal halid flood light complete all as specified and directed. Make / Model : BVP120 LED 35 CW FG S1 PSU GR of make Philips or equivalent make in list of manufactures
Supply and fixing in repairs LED fantasy bollard 11 watt bollard made of extruded aluminium housing to redefine landscapes with better light quality and enhance architecture design rated IP65 including all fittings complete all as specified and directed. Make: Wipro cat part No. LB 14-131-XXX-65-05 or equivalent make in list of manufactures
M&L for Wiring with 3 core flexible stranded 1.5Sqmm FR PVC copper cable in recessed pole in flexible PVC pipe of required size and to be fixed including connection and taking down old unsv street light wiring complete all as specified and directed by Engr-in-Charge. Note:- Three run of 1.5 sqmm size PVC cable , one run of 1.5 Sqmm size PVC cable as earth wire and one run of PVC conduit shall be measured as one unit length complete all as specified and as directed
Supply and fix pole mounted junction boxes/cut-out box /fuse box for road/street lighting for 3 phase/4 core high wattage including all connection and control street light circuit with 2 x MS clamp made out of FI of size 25x4mm for fixing the box to pole complete with nut, bolts and washers all as specified and directed. Make / Model : Cat part No. GS-JB-2817 of make Sintex or equivalent in Hensal.
Supply and fixing in repairs fantasy bollard 5 watt bollard 300 mm height made of extruded aluminium housing to redefine landscapes with better light quality and enhance architecture design including all fittings complete all as specified and directed . Make: Cat part No. LODBG05 of make Luker or equivalent in Wipro/Philips/GE.
Supply and fixing electronic driver with PCB suitable for 40/45 Watt LED street light fittings complete all as specified and directed. Make : LUKER/HPL/Philips
Supply and fixing electronic driver with PCB suitable for 50/60 Watt LED street light fittings complete all as specified and directed. Make : LUKER/HPL/Philips
Supply and fixing electronic driver with PCB suitable for 90 Watt LED street light fittings complete all as specified and directed. Make : LUKER/HPL/Philips
M & L for bracket made out of GI tubing 40mm dia,light grade 1.2 mtr long including fixing with MS clamps -2 Nos made out of 50 mm wide 5mm thick flat iron with M.S nuts bolts 75 mm long 12 mm dia -4 Nos with flat washer (3mm thick) -02 No for each including painting with aluminium paint over one coat of red oxide to the M.S clamps & bracket etc complete all as specified and directed.Make of pipe : Jindal/TATA/Surya
Supply and fix MCB TPN 16-40 Amps B Curve 440 volts with breaking capacity 10KA complete all as specified and dircetd .
Supply and fix MCB SPN 16-32 Amp B Curve 240 volts with breaking capacity 10KA complete all as specified and dircetd .
Supply and fix MCB SP 5-32 Amp B Curve 240 volts with breaking capacity 10KA confirming to IS/IEC 60898 complete all as specified and dircetd .
Excavation in trenches, n. exc 1.5 m wide and n. exc 1.5 m in depth for foundation etc.and getting out for hard/dense soil complete all as specified and directed.
Supply & Laying or fixing or passing through pipe for cable XLPE insulated, armoured heavy duty electric cable with multistranded aluminium conductor 1100 volts grade 2 core of size 10Sq.mm complete all as specified and directed
Supply & Laying or fixing or passing through pipe for cable XLPE insulated, armoured heavy duty electric cable with multistranded aluminium conductor 1100 volts grade 4 coreof size 16 Sq.mm complete all as specified and directed
Supply and lay GI tubes light grade with connected fittings laid in trenches/wall/ pole for protection to UG cables of size 25 mm dia complete all as specified and directed.
M&L for cushioning for protection of cable using dry river sand, free from particles all as specified and directed. Note: Punned thickness shall be measured and paid.
M&L for Protection of cable with old size sub-class ‘B’ bricks,one layer of new bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm for soft/loose soil complete all as specified and directed
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed
M & L for PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in coping of poles above ground leve including finishing to exposed concrete surfaces even and fair and provision of form work for rough finished surfaces including a coat of white distemper complete all as specified and directed.
Painting on street light steel tubular pole 9 Mtr Long including preparation of old painted surfaces painting two coat of aluminium paint over the surface then make paint black strip of height 10 cm upto 1 mtr , writing the pole numbers complete all as pecified and directed .
S&F Industrial type LED high bay light 80 W comprising of pressure dia cast aluminium housing adopts best heat dissipation for LED source temp rise in heat sink reflector is made from high purity aluminium with complete installation on any height complete all as specified and directed . Make : Wipro cat part No. LH21-122-060-57-XX or equivalent make in list of manufactures
Carrying out servicing/maint of 100 KVA DG set Make : 'Kirloskar' including 'B' check as per manufacturers mannual through authorised dealer of DG set manufacturer of existing DG Make and testing of DG set complete all as directed . Note :- (i) All material/spares parts required for carrying out above maintenance/servicing shall be measured and paid separetely as 'Supply only' items as mentioned below and shall be of make-Greaves/Kirloskar/Cummins as per make of DG set and labour element required for replacing the spares parts including replacement of minor spare parts which are essential for carrying out servicing/maintenance of DG sets shall deemed to be included in the unit rate quoted by the tenderer . (ii) Work shall be carried out through OEM only
All as per item No. 30 but capacity of DG Set 40 KVA complete all as specified and directed
All as per item No. 30 but capacity of DG Set 30 KVA complete all as specified and directed
All as per item No. 30 but capacity of DG Set 10 KVA complete all as specified and directed
Supply only SPIN ON LUBE OIL FILTER for 100 KVA capacitiy DG sets as per (Kirloskar Part No 06.436.01.0.00) complete all as specified and directed.
Supply only SPIN ON LUBE OIL FILTER for 30 KVA capacitiy DG sets as per (Kirloskar Part No 04.270.01.0.00) complete all as specified and directed
Supply only SPIN ON LUBE OIL FILTER for 40 KVA capacitiy DG sets as per (Kirloskar Part No 04.270.01.0.00) complete all as specified and directed
Supply only One Time Filter Kit 0.5 Ltr for 10 KVA DG set as per (Kirloskar Part No 02.999.17.0.00) complete all as specified and directed
Supply only Primary Element for100 KVA DG set as per (Kirloskar Part No 3H.132.01.0.00) complete all as specified and directed
Supply only Primary Element for 30 KVA DG set as per (Kirloskar Part No 3H.145.46.0.00) complete all as specified and directed
Supply only Primary Element for 40 KVA DG set as per (Kirloskar Part No 3H.145.46.0.00) complete all as specified and directed
Supply only Secondary Element for capacities 100 KVA DG set as per (Kirloskar Part No 3H.132.02.0.00) complete all as specified and directed
Supply only Secondary Element for capacities 30 KVA DG set as per (Kirloskar Part No 3H.132.02.0.00)complete all as specified and directed
Supply only Secondary Element for capacities 40 KVA DG set as per (Kirloskar Part No 3H.132.02.0.00) complete all as specified and directed
Supply only Main Element for air cleaner for 100 KVA DG set as per (Kirloskar Part No 04.586.03.0.00) complete all as specified and directed
Supply only Main Element for air cleaner for 30 KVA DG set as per (Kirloskar Part No 04.586.03.0.00) complete all as specified and directed
Supply only Main Element for air cleaner for 40 KVA DG set as per (Kirloskar Part No 04.586.03.0.00) complete all as specified and directed
Supply only Copper washer 14x20 as per kirloskar Part No 50.508.12.000 complete all as specified and directed
Supply only Copper washer 8x12 as per kirloskar Part No 50.508.05.000 complete all as specified and directed
Supply only Fuel pipe inlet M14xM14 Banjo both side 900L for 100 KVA Capacity DG Set as per kirloskar part No 4H.896.09.0.01 complete all as specified and directed
Supply only fuel pipe Filter to FIP for 100 KVA Capacity DG Set as per kirloskar part No 6H.081.02.0.00 complete all as specified and directed
Supply only fuel pipe feed pump to fuel filter for 100 KVA Capacity DG Set as per kirloskar part No 6H.081.03.0.00 complete all as specified and directed
Supply only Leak off pipe assembly for 100 KVA Capacity DG Set as per kirloskar part No 6H.1124.20.0.00 complete all as specified and directed
Supply only Leak off pipe assembly 4R1050TAfor 100 KVA Capacity DG Set as per kirloskar part No 4H.1323.30.0.00 complete all as specified and directed
Supply only Leak off pipe assembly for 30 KVA Capacity DG Set as per kirloskar part No 3H.175.10.0.00 complete all as specified and directed
Supply only Fuel pipe return M12x15 Male plug x M14x15 Banjo 900L for 100KVA Capacity DG Set as per kirloskar part No 06.5001.21.0.00 complete all as specified and directed
Supply only Losupply Hose(FIP) for 100KVA Capacity DG Set as per kirloskar part No 4H.006.01.0.00 complete all as specified and directed
Supply only Hose Tail connection S/F M14 for 30 KVA Capacity DG Set as per kirloskar part No 06.610.10.0.00complete all as specified and directed
Supply only Hose Clamps const press SPR Band for 30 KVA Capacity DG Set as per kirloskar part No 02.500.08.0.00 complete all as specified and directed
Supply only KG 645 controller Unit (SP3 Hard ware 12 V) for 40 KVA Capacity DG Set as per kirloskar part No 02.026.32.0.complete all as specified and directed
Supply only Cable power Flexible for 30 KVA Capacity DG Set as per kirloskar part No LPU.ELE.125.0.00complete all as specified and directed
M&L for taking down FIP and calibration as per users manual and refixing testing commissioning after repairs and replacement of parts for 100 KVA capacity DG set as per Kirloskar Part No 99.FIP.01.00 complete all as specified and directed
M&L for replacement Kirloskar Care Genuine Coolant Premix as per Kirloskar Part No 82.020.35.1.05 complete all as specified and directed
M&L for replacement Kirloskar Care super genuine engine oil as per Kirloskar Part No 82.050.10.0.20 complete all as specified and directed
M&L for replacement SS LH Hinge for Canopy all as specified and directed as per Kirloskar Part No 3H.408.90.0.00.
M&L for replacement SS RH Hinge for Canopy all as specified and directed as per Kirloskar Part No 3H.408.91.0.00.
M&L for replacement of Battery 100 AH 12 Volt all as specified and directed.Make: Tata/Exide
M&L for replacement of Battery 150 AH 12 Volt all as specified and directed. Make: Tata/Exide
S&F in repair Battery terminal clamp made up of brass with bolts and nuts complete all as specified and directed
Supply and fix in repairs AVR suitable for 100KVA DG set all as specified and directed.
Supply and fix in repairs AVR suitable for 30 KVA DG set all as specified and directed.
Supply and fix in repair four pole power contactor MCX 32 AC 160 Amps 415 Volt 50 Hz confirming to IS/IEC 60947-4-1 and IEC 60947-4-1 aux contact 2NO+2NC . Make L&T Cat Part No CS 97020 or equivalent make mentioned in list of makes complete all as specified and directed
Supply and fix in repair Moulded case circuit breaker Thermal magnetic trip unit as per IEC 60947-2 three pole 415 V 50 Hz 160 Amp 36 KA .Make. Scheneider Electric Cat Part No C16F3TM160 or equivalent make in list of manufactures complete all as specified and directed
Supply and fix electronic panel mounted LCD display KWH meter three phase class 1.0,3x240V AC supply 4 wire -/5A LT CT operated programmable as per HPL CAT Part NO CT2 Series PAMCT2E0005 complete all as specified and directed
Supply and fix Panel mounted highly sensitive Earth Fault Relay 415 volt complete all as specified and directed as per M/s Nagoba Electronics Cat Part No EL 2300 complete all as specified and directed
Supply and fix Fan belt for water pump suitable for DG set 100 KVA/30 KVA capacity kirloskar make DG set (make-Fenner/ Poly-F/ Roulunos) complete all as specified and directed
Supply and fix Fan belt for alternator dynamo suitable for DG set 100 KVA/30 KVA capacity kirloskar make DG set (make-Fenner/ Poly-F/Roulunos) complete all as specified and directed
Supply and fix Single Phasing preventor 415 Volt AC 50 Hz and unbalance trip setting 50V+ 10 %capacity As per Minilec Cat No VSP 3 complete all as specified and directed
Carrying out servicing/ preventive maint of Fire fighting system installed at MAP,Single offrs mess and gally bldg at INS agrani through authorised OEM including testing checking for serviceability as per manufacturers mannual and submission of reports duly signed by OEM complete all as directed . Note :- All material/spares parts required for carrying out above maintenance/servicing shall be measured and paid separetely as 'Supply only' items as mentioned from item No 89 to 96 labour element required for replacing the parts including replacement of minor parts which are essential for carrying out servicing/maintenance of Fire fighting system shall deemed to be included in the unit rate quoted by the tenderer against this item.
Supply only of GM Single outlet Fire Hydrant Valve, 63mm female inst. Oblique type and 80 mm flanged inlet as per IS:5290 with ABS Blank Cap and GI Chain complete all as specified and directed.Make AAAG / NewAge
Supply only of RRL Fire Hose GM of 63mm dia. X 15 Mtr.as per IS: 636, Type-B (RED), ISI marked with, 63mm male & female coupling as per IS: 903, ISI marked banded with copper wire complete all as specified and directed. Make AAAG/ NewAge
Supply only of Short Branch Pipe GM-304, 63mm x 20mm with Nozzle as per IS: 903, ISI Marked complete all as specified and directed. Make AAAG / NewAge
Supply only Double Door Hose cabinet to accommodate one piece of hose pipe along with one pair of male and female coupling and one branch pipe. The cabinet is made of 18 swg M.S. Sheet, Glass fronted with hinged door and lock. The cabinet is painted to red color,with required nuts,bolts etc complete all as specified and directed. Make SRS or equivalant make approved by GE
Supply only of Hose Reel drum of swinging type with 19mm dia Rubber braided hose of 30M. length with Gate valve (upstream) and Shut off nozzle complete all as specified and directed.Make AAAG / NewAge
Supply only of Fire Brigade inlet Siamese connection (4 way) Non Return Valve, along with 4 Nos. 63 mm dia instantaneous inlet arrangemnets to the main header with cap and chain etc complete all as specified and directed.,[For Water Tank Inlet]. Brand-KARTAR/ Equivalent
Supply only of Butterfly valve slim seal standard lever operated type confirming to IS:13039 with required type confirming to IS:13039 with required flanges, nuts, bolts etc – C.I Heavy ISI-100 mm dia complete all as specified and directed Make :LEADER /KARTAR
Supply only of of Non return valve wafer type check valve with required flanges, nuts, bolts etc- C.I-Heavy -ISI 100 mm dia complete all as specified and directed Make :LEADER /KARTAR
M&L for Analyses Inspection & Fault Rectification of fire Alarm System through OEM and submission of reports all as specified and directed .
S&F in repairs rubber flange suitable for CI butterfly valve 80,100 and 150mm dia incl taking down valve and refixing after replacement of flange all as specified and directed .
UNIQUE INDIA CONSTRUCTIONS
Rajapriyaconstruction
SKYLIGHT INNOVATIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .