Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 LAdmitted-Finance PROP NO A 80 FIRST FLOOR FLAT NO 3 CHATTAR PUR ENCLAVE PHASE 2 NEW DELHI SOUTH WEST DELHI DELHI 110074 | SOUTH DELHI | DELHI | 110074 | ₹3.2 L | L1 | Admitted-Finance |
| 2 | L2₹3.3 L+₹8,047.50 (2.50%)Admitted-Finance | ₹3.3 L+₹8,047.50 (2.50%) | L2 | Admitted-Finance |
| 3 | L3₹3.5 L+₹27,405.50 (8.51%)Admitted-Finance | ₹3.5 L+₹27,405.50 (8.51%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M G Traders and Engineers L1 | paramount systems L2 | Gupta Brothers L3 |
|---|---|---|---|---|---|---|
| 1.01 | Lifting of p/set by the help of chain pully, clamps and heavy menpower after cuting rusted/wornout and opening of nut bolts to dismental the p/set, pipes etc. | 2 | Job | 5,000 ₹5,900 | 2,000 ₹2,000 Lowest | 6,000 ₹7,080 |
| 1.02 | Repairing of 10 H.P submbersible Pump Set having work of rewinding of motor, Cable 4 Sq. mm- 6 mtr., replacement of G.M Bearing Bushs, Upper Bushs, Guide Bushs , Distance Bush and Balancing of rotor with rotor sleeve turning & grinding and also repairing of Impeller. The job also includes the labour charges for rewinding/repairing of p/set. | 1 | nos. | 8,500 ₹10,030 Lowest | 20,000 ₹23,600 | 10,000 ₹11,800 |
| 1.03 | S/o submersible cable with copper conductor having three core sizes 6 sq. mm working on 1100 V. Make:-Finolex/Plaza/Unistar/Havells or any other make approved by DJB. | 273 | mtr. | 61,425 ₹72,481.5 Lowest | 68,250 ₹80,535 | 68,250 ₹80,535 |
| 1.04 | Making and supply of MS clamp of 500 mm long x 75 width x 12 mm thick complete with nut and bolts and washers for holding the 50 mm dia pipe including bending and shaping etc. as required. | 2 | nos. | 4,700 ₹5,546 | 1,600 ₹1,888 Lowest | 2,000 ₹2,360 |
| 1.05 | S/o NRV 50 mm dia CI double flanges Make:-Kirloskar /IVC or any other make approved by DJB. | 1 | Nos. | 7,400 ₹8,732 | 4,000 ₹4,720 Lowest | 6,900 ₹8,142 |
| 1.06 | S/o CI sluice valve 50 mm , non rising S.S. spindle Make:- Kirloskar /IVC or any other make approved by DJB. | 1 | nos. | 8,500 ₹10,030 | 5,500 ₹6,490 Lowest | 10,000 ₹11,800 |
| 1.07 | S/o G.I bend 50 mm dia 90deg. Double flange. Heavy class Make: - Ganesh/ ISI | 2 | nos. | 3,100 ₹3,658 | 1,600 ₹1,888 Lowest | 2,000 ₹2,360 |
| 1.08 | S/o of 3 mtr. GI pipe 50 mm dia size ,medium class with GI flange welded in both sides 3 Mtr long with ms strips complete with threading work on each side of pipe each flange should be 4 holes and cut for cables. Make of pipe :- Jindal / TATA. | 38 | nos. | 77,900 ₹91,922 | 70,300 ₹82,954 Lowest | 95,000 ₹1,12,100 |
| 1.09 | S/o G.I required off size threaded heavy duty nut-bolts of good quality. | 80 | kg | 7,600 ₹8,968 Lowest | 8,800 ₹10,384 | 8,000 ₹9,440 |
| 1.10 | Supply of MS bore cover 4 mm thick suitable for bore size in 2 pieces complete with bolting arrangement angle iron frame and provision of 50 mm dia hole in the center. | 2 | nos. | 3,100 ₹3,658 | 2,000 ₹2,360 Lowest | 3,000 ₹3,540 |
Tender Value
Refer Docs
EMD Value
₹7,800
Closing Date
22 Jun 2026, 3:15 pmClosed
EE ENM M-4
Sector-19 BPS Rohini, Delhi-89
Repairing of 2 nos of Tube wells at Sector A6 Pkt 4 and Sector A10 Pkt 7 Narela AC 01
2026_DJB_293553_7
NIT No. 05(2026-27)M-4
Open Tender
Miscellaneous Works
Item Rate
30 days
EE ENM M-4
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Account No 50448339804
₹7,800
Yes
24 Jun 2026
16 Jun 2026
22 Jun 2026
16 Jun 2026
22 Jun 2026
16 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Lifting of p/set by the help of chain pully, clamps and heavy menpower after cuting rusted/wornout and opening of nut bolts to dismental the p/set, pipes etc. | 2 | Job | 80 | ₹160 |
| 1.02 | Repairing of 10 H.P submbersible Pump Set having work of rewinding of motor, Cable 4 Sq. mm- 6 mtr., replacement of G.M Bearing Bushs, Upper Bushs, Guide Bushs , Distance Bush and Balancing of rotor with rotor sleeve turning & grinding and also repairing of Impeller. The job also includes the labour charges for rewinding/repairing of p/set. | 1 | nos. | 80 | ₹80 |
| 1.03 | S/o submersible cable with copper conductor having three core sizes 6 sq. mm working on 1100 V. Make:-Finolex/Plaza/Unistar/Havells or any other make approved by DJB. | 273 | mtr. | 80 | ₹21,840 |
| 1.04 | Making and supply of MS clamp of 500 mm long x 75 width x 12 mm thick complete with nut and bolts and washers for holding the 50 mm dia pipe including bending and shaping etc. as required. | 2 | nos. | 80 | ₹160 |
| 1.05 | S/o NRV 50 mm dia CI double flanges Make:-Kirloskar /IVC or any other make approved by DJB. | 1 | Nos. | 80 | ₹80 |
| 1.06 | S/o CI sluice valve 50 mm , non rising S.S. spindle Make:- Kirloskar /IVC or any other make approved by DJB. | 1 | nos. | 80 | ₹80 |
| 1.07 | S/o G.I bend 50 mm dia 90deg. Double flange. Heavy class Make: - Ganesh/ ISI | 2 | nos. | 80 | ₹160 |
| 1.08 | S/o of 3 mtr. GI pipe 50 mm dia size ,medium class with GI flange welded in both sides 3 Mtr long with ms strips complete with threading work on each side of pipe each flange should be 4 holes and cut for cables. Make of pipe :- Jindal / TATA. | 38 | nos. | 80 | ₹3,040 |
| 1.09 | S/o G.I required off size threaded heavy duty nut-bolts of good quality. | 80 | kg | 80 | ₹6,400 |
| 1.1 | Supply of MS bore cover 4 mm thick suitable for bore size in 2 pieces complete with bolting arrangement angle iron frame and provision of 50 mm dia hole in the center. | 2 | nos. | 80 | ₹160 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.10 MB
BOQ_390184.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .