Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.8 LAccepted-AOC | L1 | Accepted-AOC Lowest amount | |
| 2 | L2₹38.2 L+₹1.7 L (4.66%)Rejected-Finance | L2 | Rejected-Finance Not reasonable | |
| 3 | L3₹42.1 L+₹5.6 L (15.4%)Rejected-Finance GARDEN AVENUE PLOT NO 242 243 244 RH 4 SECTOR 21 NERUL NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L3 | Rejected-Finance Not reasonable | |
| 4 | L4₹45.2 L+₹8.7 L (23.9%)Rejected-Finance NOT AVAILABLE | FARIDABAD | HARYANA | 121004 | L4 | Rejected-Finance Not reasonable | |
| 5 | L5₹46.6 L+₹10.1 L (27.7%)Rejected-Finance ROOM NO D 297 PART III GANESH MURTI NAGAR CUFF PARADE ROAD COLABA MUMBAI 400005 | MUMBAI | MAHARASHTRA | 400005 | L5 | Rejected-Finance Not reasonable |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
7 Jan 2021, 6:00 pmClosed
MAj N P Singh
GE (West) Colaba, Mumbai
REPAIRS TO BLDG ROOF, WATER PROOFING TREATMENT AND OTHER CONNECTED ITEMS AT CERTAIN BLDGS UNDER AGE B and R WEST UNDER GE West COLABA, MUMBAI
2020_MES_402598_1
8493/E8
Open Tender
Civil Works
Item Rate
180 days
GE (West) Colaba
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (West)
₹98,000
Yes
27 Feb 2021
10 Dec 2020
9 Jan 2021
10 Dec 2020
7 Jan 2021
24 Dec 2020
Amount
Demolition of brick work or stone /boulder masonry built in cement mortar, including all quoins, arches, pillars, etc. complete all as specified and directed.
Demolition of cement Concrete of any description and in any position not otherwise specifically provided for and removing debries out side MoD land complete all as specified and directed.
Taking down cement plaster on brick/ concrete surfaces, built in cement mortar including raking out joints, hacking for key, scrubbing down with water etc and removing debries out side MoD land complete all as specified and directed.
Disconnecting and dismantling of existing water storage tank of exceeding 2000 ltrs capacity of any description shifting and refixing and reconnecting to its originaal position after completion of water proofing treatment of roof complete all as specified and directed.
Removal of complete roof treatment including plastering/concreting /brick bat surfaces and removing the debris outside MoD land complete all as specified and directed.
M & L for brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius and built in CM (1:6) complete all as specified and directed.
M & L for rendering 15 mm thick in CM 1:6 on fair faces of brick work or concrete surfaces, finishing the surface fair and even complete all as specified and directed.
M & L for cleaning all loose laitance on the concrete substrate and applying one coat of epoxy bonding agent on exposed concrete surface to ensure bond between old concrete & new concrete by brush application including scafolding at any height as specified and directed. Make / brand Monobond SBR of Krishna Conchem or Dr. Fixit epoxy bonding agent or Shalicrete URP of STP Ltd.
M & L for rendering minimum 20 mm thick on average, polymer modified mortar in cemet mortar (1:3) with graded quartz sand with additive Monolith - PMM of Krishnaconchem or Shalifix RM SG 01 of STP Ltd. or equivalent 15% by weight of cement in one coat with and including curing as per manufacturer's instruction complete all as specified and as directed. Note :- (i) Repirs to be done by authorised applicator of Dr Fixit/ Build Core/Fosroc/Pedilite as approved by GE. (ii) Quantity of polymer shall be 15% by weight of cement. (iii) Pan mixer shall be used to get homogenous dough on bond coat surfaces. (iv) Repaired surfaces area shall be kept moist for 5-7 days.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed.
Hard drawn steel wire fabric cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcement not exceeding 4kg per sqm complete all as specified and directed.
M & L for PCC 1:2:4 type B0 using 12.5 mm graded stone aggregate, as in roof kerbs/padding, using LW+ water proofing chemical of Dr. Fixit or equivalent as per manufacturer's instruction etc complete all as specified and directed. Note: WPC will be measured and paid separately as supply only.
M & L for water proofing plaster at any position including wall, ceiling, roof, chajjas, parapet in CM 1:3, 15 mm thick in two coats using Pidiproof LW+ water proofing chemical of Dr. Fixit or equivalent as per manufacturer's instruction and finishing the surface even and smooth without using extra cement complete all as specified and directed. Note: Water Proofing Chemical shall be measured and paid separately as supply only.
Supply only Water proofing chemical Pidiproof LW+ of Dr. Fixit or Equivalent complete all as specified and directed.
Supply only Water proofing chemical Dr.Fixit 301 Pidicrete URP of Dr. Fixit or Equivalent complete all as specified and directed.
S & F in repair for the roof/floor surface thoroughly wire brushed, washed and dried up and cleaned of all foreign matter and dust to receive bituminous primer, apply bituminous based cold applied primer @ 270 to 300 gms/Sqm manufactured by the same agency as that of APP all as per manufacturers instructions. Laying 5 layered, 4 mm thick APP (A tactic poly propylene) modified membrane reinforced with 180 GSM (Gms/Sqm) of non woven polyester mat, applied by thermo fusion using LPG torch on the bottom portion of the membrane with an overlap of 75mm in longitudinal direction for accessible roof complete all as specified and directed.
Cutting out cracks to V-section in existing roofs or terracing, cleaning out, and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 ( by weight) complete all as specified and directed.
M & L for grouting, providing 12 mm dia holes of 75mm deep @0.6 m c/c at junction of beams and columns as co-ordinal points for inserting/pouring mixture of ready made epoxy grout by pressure grouting for column, beams and slabs, including sealing the holes with CM 1:3, complete all as specified and directed. Make: Sika Sikadur®-42 HES IN or equivalent as approved by GE.
M & L for preparation of surfaces by cutting 'V' groove cracks of plaster internal/external of walls, ceilings/Chajjas all along the crack upto 10 mm and remove the loose plaster/concrete by suitable tools, filling cracks with crack paste compound and apply the second coat after 10-12 hrs of application of first coat and for external application must be coated with paint including necessary scafolding of any hieght complete all as specified and directed. Make : Use of Dr Fixit Crack 'X' shrinkfree paste compound/ Smartcare Texture Crack Filler / Build Core Compound / Fosroc Compound, as approved by GE.
Dismantling ACP bording in any form including letters and symbol written over it as in entrance or otherwise in any form complete all as specified and directed.
S & F 3 mm thick Aluminium composite panel cladding plain metallic of approved colour/ shade to beam/ column/ slab in circular/ rectangular shape including cutting, notching, bending to shape as required jointing with silicon gel of approved colour & Aluminum tubular hallow section 25 x 25 mm not exceeding 900 mm c/c on exceeding columns / beam/ slab to hold APC cladding etc. complete all as specified and directed. Note:- Colour & Pattern of ACP sheet shall be as approved by GE. Make: Eurobond / Alstrong / Alstone / Alucoboand.
S & F Brass letters or figures (Block, Roman, Italic, Indian) n exc 20 cm high made of 3 mm thinkness complete all as specified and as directed.
Dismantling stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar complete all as specified and directed.
S & F 20 mm thick Granite stone slab (of any type and shade, table rubbed and polished) in steps, risers, jambs, pillars, window cills, cooking platform, and like, over and including 15mm thick rendering / screed bed in cement mortar ( 1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
All as per item No.24 above but as in floors complete all as specified and directed.
M & L for preparation of newly plastered surfaces of walls, applying two coats of oil emlusion distemper over a coat of alkali-resistant priming paint over 3mm thick (average thickness) wall care putty complete all as specified and directed.
M & L for providing and applying two coats of Fiber Reinforced elastomeric Liquid applied membrane of Asian Paints or equivalent make, having crack bridging ability upto 2.5 mm, resistance to positive hydrostatic pressure of upto 10 bars, superior anti-carbonation, 1st coat self-priming coat & 2nd coat undiluted coat ensuring force coverage of 30 Sq. ft/kg for 2 coat with 160 micron DFT, applying one coat of thick modified acrylic silica base texture (2mm to 2.5 mm thick) as per desired pattern and 8 hours two coats of Ultra durable pure acrylic exterior emulsion with Low VOC , Anti Algal, Excellent DPUR for dust pick up resistance of fading of colors ensuring 60 micron DFT for two coats, through authorised applicators of manufactureres of materials complete all as specified and directed. Make: Asian Paints or equivalent as approved by GE.
M & L for preparation of newly plastered or un plastered wall surfaces, over 10cm width or girth, applying two coats of 100% acrylic, weather resistant emlusion over a coat of exterior wall primer, all as per manufacturer's instructions complete all as specified and directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S & F for joist, channel, angle, or tee sections, or MS Flats fixed independantly without connecting plates, etc Fe 410-W (Gde-E- 250) quality- A (cut to ordinary lengths i.e within 20mm of length indicated) as in frame work for Galvalume / CGI chajjas/ Cladding etc complete all as specified and directed.
Erection and Fixing for old rolled mild steel sections of as in post, runners, rafters, purlins steps etc fixed with connecting plates including bending, welding etc complete complete all as specified and directed.
S & F in repairs pre-painted galvalume aluminium zinc coating GI baseds corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
All as per item No. 32 above but plain galvalume sheets for ridges/ Flashings etc.
M & L for 1.5 mm thick galvanised steel sheet as in Valley gutters fixed with rivets or other suitable arrangements over MS brackets Trapezoidal shape of required profile with desired slope etc complete all as specified and directed.
S & F in repair PVC Tensile Fabric Structures having with PVDF (polyvinyl-idene-fluoride) coating with all necessary fixtures, of any size and shape for making canopies, shed (Seating places) fixed to mild steel structural frame work, weight of the fabric ranging from 1000gsm to 1500 gsm, sample as approved by GE complete all as specified and directed. Note : (a) The shape/ design of the sheds will be as approved by GE. (b) Cost of structural steel used will be measured and paid separetly under relevant items in this schdule. Make: Mehler/ Sieon/ Haytes/ Ferrari or equivalent as approved by GE.
S&F for rolled Galvanised mild steel Sections of Grade Fe 410-W, (Gde- E-250) quqlity-A, as in post, runners, rafters, purlins, steps etc fixed with connecting plates including bending, welding etc complete including cleats, brackets, etc. for placement of PVC fabric shed complete all as specified and directed.
All as per item No. 36 above but MS Plates ( plain or chequered)
M & L for preparation of old steel surfaces exc 10 cm width or girth and applying one coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed .
M & L for preparation of newly steel surfaces exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed .
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ any thickness, including cover fillets complete all as specified and directed.
M & L for powder coated aluminium snap grid having a size of 605mm x 605mm and sections incorporated in frame work shall conform to IS 733, IS 737 and IS 1285 and snap grid frame work shall be fixed to ceiling with supporting hanger 6mm dia mild steel rod, J bolts with necessary bolts, nuts and washers all as per manufacturer's instruction. The main & cross tees shall be jointed at junction/crossings with anodized aluminum angle bracket of size 19.05mm x 19.05mm x 1.45mm, weighing 0.14 Kg per RM, fixed with suitable mild steel, bolts nuts and washer all as per manufacturer's instruction, the snap grid shall be supported at ends all along the wall with anodized aluminum angle of size 38mm x 25mm x 2.18mm, weighing 0.358 Kg per running meter complete all as specified and directed.
S & F 9mm thick PVC laminated gypsum ceiling tiles size of 600mm x 600mm, square edge, front side laminated PVC and back side aluminium foil complete all as specified and directed.
M & L for Providing and fixing 12 mm thick plaster of paris ceiling (Gypsum anhydrous) to flat surface with GI frame work for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/ intermediate channel 0.9mm thick having equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900 mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel at 457mm centre to centre with & incl Hangers 4mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified and directed.
Extra over above item No. 43 for any sunk or raised moulding.
Dismantling Mangalore pattern or similar tiles in roofing including portions bedded in cement mortar of any height including use of scafolding complete all as specified and directed.
Material and labour for roof tiles, Mangalore Pattern, interlocking at side joints, laid dry including use of scafoldings of any height complete all as specified and directed.
Fixing only roof tiles, Mangalore Pattern, interlocking at side joints, laid dry including scafoldings of any height complete all as specified and directed.
Material and labour for ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in cement mortar 1:6 complete all as specified and directed.
Fixing only ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in cement mortar 1:6 including scafoldings of any height complete all as specified and directed.
M & L for preparing old prepainted surfaces of manglore roof tile by scraping / rubbing and applying two coats of modified acrylic based pigmented water based coating including use of necessary scaffolding of any height complete all as specified and directed. Make : ASIAN PAINTS - APEX TILE GUARD OR DULAX - Roof gurad as approved by GE.
Dismantling of roof battens for tiles, shingles etc, of any size including tilting fillets spaced n exc 15 cm of any description in any position complete all as specified and directed.
Material and labour second class hardwood clean sawn battens at 30cm centres sectional area exc 15 & n exc 25 Sqcm including use of scafoldings of any hieght complete all as specified and directed.
Fixing only second class hardwood clean sawn battens at 30cm centres sectional area exc 15 & n exc 25 Sqcm including use of scafoldings of any height complete all as specified and directed.
Supply and fix in repairs to replace old or decayed boarding in patches including cutting out old, piecing, heading joints etc 20 mm thick second class hardwood clean sawn boarding fixed with nails with butt joints in any situation including use of scafoldings of any hieght complete all as specified and directed.
Fixing only in repairs in patches including cutting out old, piecing, heading joints etc 20 mm thick second class hardwood clean sawn boarding fixed with nails with butt joints in any situation including use of scafoldings of any height complete all as specified and directed.
Material and labour in repairs to replace old or decayed boarding in patches including cutting out old, piecing, heading joints etc second class hardwood wheather boarding , clean sawn, plain, 20 mm thick or feather edged 15 mm to 20 mm thick and fixed with 30 mm laps in any situation including use of scafoldings of any hieght complete all as specified and directed.
Material and labour for preparation of new wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (ordinary paint tint) (each coat) over a coat of pink primer including use of scafoldings of any height complete all as specified and directed.
Material and labour for preparation of old decorated wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (ordinary paint tint) (each coat) over a coat of pink primer including use of scafoldings of any hieght complete all as specified and directed.
Material and labour in repairs to replace old decayed timber ( including piecing, scarifying, etc of old and new timber if required) second class hard wood clean sawn in scantlings timber framed and fixed in any position and description including use of scafoldings of any height complete all as specified and directed.
Material and labour for preparing surfaces of battens, any size and spacing, and treated all over with creosote (measured overall on one side only, spaces not deducted) including use of scafoldings of any height complete all as specified and directed.
Removal of tree roots and branches spreed over stone/concrete wall joints and making good the stone wall joints by flash pointing in CM 1:4 including use of necessary scafolding and removing the debris outside MoD land complete all as specified and directed.
PRABHU ASSOCIATES
M/s S.D Construction Co
ASHOK CONSTRUCTION
GANGAJAL
Vandan Enterprises
M/s Radhika Enterprises
Bidder Name
ASHOK CONSTRUCTION
M/s S.D Construction Co
Vandan Enterprises
PRABHU ASSOCIATES
Bright Construction Co
GANGAJAL
M/s Radhika Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .