Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.1 LAccepted-AOC 1001 63 SHALIMAR GARDEN ISMAILGANJ NEAR INDIRA NAGAR SECTOR 08 CROSSING LUCKNOW 226016 | LUCKNOW | UTTAR PRADESH | 226016 | L1 | Accepted-AOC Being the lowest tenderer and fulfilling all the criteria | |
| 2 | L2₹28.8 L+₹1.0 L (3.73%)Rejected-Finance 27 1ST STREET PERIYAR NAGAR 1ST STREET PERIYAR NAGAR ADAMBAKKAM KANCHIPURAM TAMIL NADU 600088 | CHENNAI | TAMIL NADU | 600088 | L2 | Rejected-Finance Not being the lowest tenderer | |
| 3 | L3₹40.9 L+₹13.2 L (47.5%)Rejected-Finance NO 235 PSK ILLAM SANKARAN NAGAR CHINNAMMAN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L3 | Rejected-Finance Not being the lowest tenderer |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
31 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Chennai
Fort Saint George, Chennai
REPAIRS MAINTENANCE OF FANS, GEYSERS AND ALLIED WORKS AT ZONE C AND E AREA UNDER GE CHENNAI
2021_MES_464908_1
8532/E8
Open Tender
Electrical and Maintenance Works
Item Rate
274 days
Fort Saint George
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Chennai
₹96,000
Yes
6 Oct 2021
3 Aug 2021
7 Sept 2021
3 Aug 2021
31 Aug 2021
17 Aug 2021
60 days
Amount
BOQ UPLOADED ON 03 AUG 2021
Taking down carefully, dismantling and opening the following fans of any size/ any make after disconnecting the electric connection for attending repairs, reassembling, refixing and re-connecting the fans to ceiling rose/connector after necessary servicing and replacing the spare parts etc., complete all as specified and as directed:- Note: (i) Rewinding, painting and supply only of spares will be measured separately. (ii) Servicing like cleaning, application of lubricant oil/ grease, replacement of pins, nuts, bolts etc. is deemed to be included in the quoted rates.
Ceiling fan 1200mm/ 1450mm sweep.
Exhaust fan plastic body upto 300mm sweep.
Exhaust fan iron body upto 300mm sweep.
Exhaust fan iron body 450mm sweep.
Wall mounting fan air circulator of any sweep.
Rewinding of fans of any make/ type of following sweep with super enamelled copper wire of suitable size to get designed speed for the particular make of fans including insulating varnishing, providing sleeves etc., complete all as specified and as directed:- Note: All spare parts and painting shall be measured and paid separately.
Ceiling fan 1200 mm/ 1400mm sweep.
Wall mounting fan air circulator of any sweep.
Exhaust fan iron body upto 300mm sweep.
Exhaust fan iron body 450mm sweep.
Exhaust fan plastic body upto 300mm sweep.
Supply only condenser 2.5 Mfd capacity for any make/ sweep/ type of fans, conforming to relevant IS specification and as directed.
Supply only condenser 3.15 Mfd capacity for any make/ sweep/ type of fans, conforming to relevant IS specification and as directed
Supply only condenser 4 Mfd capacity for any make/ sweep/ type of fans, conforming to relevant IS specification and as directed
Supply only ball bearing of size 6201 suitable for any make/ sweep/ type of fans, conforming to relevant IS specification.
Supply only ball bearing of size 6202 suitable for any make/ sweep/ type of fans conforming to relevant IS specification.
Supply only ball bearing of size 6203 suitable for any make/ sweep/ type of fans conforming to relevant IS specification.
Supply only gun metal bush for any make/ sweep / type of fans.
Supply only canopy plastic with fixing arrangement, top and bottom for ceiling fan of any make/ sweep as specified and directed.
Supply only rubber bush real type suitable for 1200/ 1400/ 1500mm sweep ceilings fans of any make as specified and directed.
Supply only steel shaft for the motor suitable for ceiling fan of any make/ type/ sweep complete all as specified and directed.
Supply and fixing condenser housing clamp for ceiling fan of any size all as directed.
Supply only ceiling fan hanging clamp with rubber bush suitable for ceiling fan of any size all as specified and directed.
M&L repair to steel shaft of motor of exhaust fan of any size by welding and grinding complete all as directed.
M&L for applying one coat of synthetic enamel paint with spray gun on body and blades of ceiling fans of any size including filling the cavities with filler after cleaning, scraping all dust/ rust from fans/ down rods/ blades etc., and numbering the fans "MES NO" with black enamel paint complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint with spray gun on body and blades of exhaust fan of any size including filling the cavities with filler after cleaning, scraping all dust/ rust on fans/ blades etc. and numbering the fans "MES NO" with black enamel paint complete all as specified and directed.
Supply only down rod 15mm bore made out of galvanised iron with complete provision for hanging ceiling fan including cutting, provisioning of threads at both ends and making suitable holes for inserting split pins/ cotter pins including suitable check nuts and necessary clamps socket with insulating rubber bush complete all as specified and directed.
Supply and fix electronic ceiling fan regulator, dimmer type, 450 watts, 250 volts all as specified and directed.
Supply and fix modular fan regulator, step type, 120 Watt, 2-module including taking down old damaged fan regulator any type complete all as specified and directed.
Supply and fix ceiling rose PVC/ Polycarbonate body 65 x 50mm; 2 to 3 terminals 230 Volts, AC Single phase including taking down old damaged ceiling rose complete all as specified and directed.
Supply and fix switch piano, flush type, single pole, one way, 5 Amps, 230 volts including taking down old damaged switch complete all as specified and directed.
Supply and fix modular switches suitable for AC 230V, 6 amps including taking down of old damaged/ unserviceable switches complete all as specified and directed.
Supply and fixing blade set for ceiling fan of size 1200mm sweep of any make, colour and pattern as per existing one with fixing screws complete all as specified and directed.
Supply and fixing in repairs hanging hook for ceiling of round shape suitable for 50mm dia pipe with suitable nuts and bolts etc. complete all as specified and directed.
Supply 1.00 sqmm twin core flexible wire with copper conductor and connecting from ceiling rose to fan all as specified and directed.
Supply and fixing in replacement PVC outer cover suitable for 250mm size plastic exhaust fan all as specified and directed.
Supply and fixing in replacement louvers suitable for exhaust fan of size upto 450mm sweep as per existing size complete all as specified and directed.
Supply and fixing fastener 4" suitable for fixing exhaust fan on wall all as specified and directed.
Supply and fixing 50mm dia galvanised iron light grade pipe fixed with clamps of suitable size complete all as specified and directed.
Taking down carefully storage type water heater (Geyser) of any type and any make upto 50 Litre capacity after disconnecting all electric connection; descaling the inner container, heating element, base assembly etc. by using diluted hydrochloric acid and cleaning thoroughly, filling the inner container with water and checking and arresting leakage if any, reassembling the geyser after servicing and replacing unserviceable spare parts and refixing including making water connections and testing on completion complete all as specified and directed. Notes: (i) Spare parts like heating element, thermostats, hot/ cold water lines, PVC connections etc., shall be measured and pair separately. (ii) Painting shall be measured and paid separately.
Supply and fixing in repairs copper/ steel inner container of the geysers including replacement of worn out brass studs and copper tubing for the following capacity complete all as specified and directed:-
Geysers of capacity 25 Ltrs.
Geysers of capacity 50 Ltrs.
Supply only heating element 2 KW capacity suitable for AC single phase 50Hz, 230 Volts suitable for geysers for thread type/ press type/ triangular/ circular type all specified and as directed.
Supply only heating element 1.5KW capacity suitable for AC single phase 50Hz, 230 Volts suitable for geysers for thread type/ press type/ triangular/ circular type all specified and as directed.
Supply only thermostat automatic cut off with ISI mark suitable to geysers of any range from 20° C to 90° C all as specified and directed.
Supply only hot water steel guarded PVC connection pipe 450mm long with self locking nut at both ends suitable for 15mm bore outlet all as specified and directed.
Supply only cold water steel guarded PVC connection pipe 450mm long with self locking nut at both ends suitable for 15mm bore outlet all as specified and directed.
M&L for applying one coat of synthetic enamel paint white or brown tint as directed by spraying to the geysers including cleaning the dust/ rust from the body and numbering the geysers 'MES No' with black enamel paint complete all as specified and directed.
Supply only phase indicating neon lamp round or rectangular type suitable for single phase 230 volts, 50Hz AC for respective make of the geysers. Note: Set of two lamps containing green and red colour shall be counted as one unit.
Supply only non return valve 15mm bore of gun metal conforming to relevant IS specification all as specified and directed.
Supply & fixing iron top body cover for storage geyser of 25 litre capacity including screws complete all as specified and directed.
Supply & fixing iron top body cover for storage geyser of 50 litre capacity including screws complete all as specified and directed.
Supply & fixing iron bottom body cover for storage geyser of 25 litre capacity including screws complete all as specified and directed.
Supply & fixing iron bottom body cover for storage geyser of 50 litre capacity including screws complete all as specified and directed.
Supply & fixing copper assembly for storage geyser of 25 litre capacity including screws complete all as specified and directed.
Supply & fixing copper assembly for storage geyser of 50 litre capacity including screws complete all as specified and directed.
Supply & fixing assembly cover for storage geyser of 25 litre capacity including screws complete all as specified and directed.
Supply & fixing assembly cover for storage geyser of 50 litre capacity including screws complete all as specified and directed.
Supply & filling glass wool in storage geyser of any litre capacity all as specified and directed.
Supply & fixing 15 Amp 3 pin plug top all as specified and directed.
Supply and connecting 2.5 sqmm 3 core flexible cable with copper conductor as in connection wire from geyser connection plate to socket all as specified and directed.
Supply and fixing 15mm bore medium grade galvanised iron tubing fixed to wall with suitable clamps including taking down existing pipe complete all as specified and directed.
Supply & fixing in repairs stop valve, cast copper alloy with crutch or butterfly handle, screwed down, screwed for 15mm bore iron pipe or brass ferrule complete all as specified and directed.
Supply & fixing in repairs bib tap, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for 15mm bore iron pipe or brass ferrule complete all as specified and directed.
M&L for submain wiring complete with two runs of 4.0 Sqmm single core, multistranded, FR PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through and including new rigid non metallic PVC conduit medium grade ISI marked 25mm external dia concealed in wall/ floor along with conduit fittings and accessories, fixed on ceiling with one run of 4.0 Sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly including taking down existing submain wiring with conduit any type complete all as specified. Note: Two runs of 4.0 sqmm multistranded cable and one run of 4.0 sqmm cable as earth continuity conductor alongwith PVC conduit shall be considered as one unit length.
M&L for submain wiring complete with two runs of 6.0 Sqmm single core, multistranded, FR PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through and including new rigid non metallic PVC conduit medium grade ISI marked 25mm external dia concealed in wall/ floor along with conduit fittings and accessories, fixed on ceiling with one run of 6.0 Sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly including taking down existing submain wiring with conduit any type complete all as specified. Note: Two runs of 6.0sqmm multistranded cable and one run of 6.0sqmm cable as earth continuity conductor alongwith PVC conduit shall be considered as one unit length.
M&L for submain wiring complete with two runs of 10.0 Sqmm single core, multistranded, FR PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through and including new rigid non metallic PVC conduit medium grade ISI marked 25mm external dia concealed in wall/ floor along with conduit fittings and accessories, fixed on ceiling with one run of 10.0 Sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly including taking down existing submain wiring with conduit any type complete all as specified. Note: Two runs of 10.0 sqmm multistranded cable and one run of 10.0 sqmm cable as earth continuity conductor alongwith PVC conduit shall be considered as one unit length.
M&L for submain wiring complete with four runs of 10.0 Sqmm single core, multistranded, FR PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through and including new rigid non metallic PVC conduit medium grade ISI marked 25mm external dia concealed in wall/ floor along with conduit fittings and accessories, fixed on ceiling with two runs of 10.0 Sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly including taking down existing submain wiring with conduit any type complete all as specified. Note: Four runs of 10.0 sqmm multistranded cable and two runs of 10.0 sqmm cable as earth continuity conductor alongwith PVC conduit shall be considered as one unit length.
Supply, fix, connecting and testing factory made, MCB distribution board (MCB DB), IP 38, SPN, 4 way, 240 Volts, double door, flush type made out of 1.2mm thick CRCA sheet metal, Phosphatised, duly powder coated and conforming to IS 13032 with 200 Amps rated bus bar, neutral link, earth bar and din rail etc. complete fixed in switch board/ wall including taking down the existing one complete all as specified and directed. Note: MCBs shall be measured and paid separately.
Supply, fix, connecting and testing factory made, MCB distribution board (MCB DB), IP 38, SPN, 8 way, 240 Volts, double door, flush type made out of 1.2mm thick CRCA sheet metal, Phosphatised, duly powder coated and conforming to IS 13032 with 200 Amps rated bus bar, neutral link, earth bar and din rail etc. complete fixed in switch board/ wall including taking down the existing one complete all as specified and directed. Note: MCBs shall be measured and paid separately.
Supply, fix, connecting and testing factory made, MCB distribution board (MCB DB), IP 38, TPN, 6 way, 240 Volts, double door, flush type made out of 1.2mm thick CRCA sheet metal, Phosphatised, duly powder coated and conforming to IS 13032 with 200 Amps rated bus bar, neutral link, earth bar and din rail etc. complete fixed in switch board/ wall including taking down the existing one complete all as specified and directed. Note: MCBs shall be measured and paid separately.
Supply, fix, connecting and testing factory made, MCB distribution board (MCB DB), IP 38, TPN, 8 way, 240 Volts, double door, flush type made out of 1.2mm thick CRCA sheet metal, Phosphatised, duly powder coated and conforming to IS 13032 with 200 Amps rated bus bar, neutral link, earth bar and din rail etc. complete fixed in switch board/ wall including taking down the existing one complete all as specified and directed. Note: MCBs shall be measured and paid separately.
Supply, fix, connecting and testing MCB TPN, 63 Amps, 415 V of rupturing capacity 10kA, C curve type including taking down the existing one complete all as specified and directed.
Supply, fix, connecting and testing MCB TPN, 40 Amps, 415 V of rupturing capacity 10kA, C curve type including taking down the existing one complete all as specified and directed.
Supply, fix, connecting and testing MCB SPN, 63 Amps, 240 volts of rupturing capacity 10kA, C curve type including taking down the existing one complete all as specified and directed.
Supply, fix, connecting and testing MCB SPN, 40 Amps, 240 volts of rupturing capacity 10kA, C curve type including taking down the existing one complete all as specified and directed.
Supply, fix, connecting and testing MCB single pole (MCB SP), 63 Amps, 240 volts of rupturing capacity 10kA, C curve type including taking down the existing one complete all as specified and directed.
Supply, fix, connecting and testing MCB single pole (MCB SP), 6 to 32 Amps, 240 volts of rupturing capacity 10kA, C curve type including taking down the existing one complete all as specified and directed.
Supply, fix, connecting and testing MCCB four pole 100 Amps, 415 volts breaking capacity, 16kA with fixed thermal setting including taking down the existing one complete all as specified and directed.
Supply, fix, connecting and testing MCCB four pole 63 Amps, 415 volts breaking capacity, 16kA with fixed thermal setting including taking down the existing one complete all as specified and directed.
Supply and fix single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps, 230 Volts including taking down old one complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode of size 600mm x 600mm x 6.0mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of plate not less than 1.5m below normal ground level, earth plate connected to galvanized iron earth wire of 4mm dia as earthing conductor by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES Schedule (Part I) (2009) connected to earth test point/ main switch/ DB/ Panel board all as specified or indicated including testing on completion with and including 15mm bore light grade GI protection pipe 7.5 meter long for earth strip including PCC (1:3:6), type C-1 pit with 40mm thick precast RCC (1:2:4), type B -1 cover reinforced with 12mm dia MS bars @ 150mm c/c both ways with lifting hooks made out of 12mm dia MS bars, wire mesh funnel with watering pipe 20mm dia light grade, common salt, charcoal filling in layers as specified, necessary excavation and earth work in any type of soil etc., complete all as specified and as directed.
EVEREST ENGINEERING WORKS
PSK Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .