Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical 1507 DWARKAMAI SAI NAGAR ST ANTHONY ROAD CHEMBUR MUMBAI 400071 | MUMBAI | MUMBAI | MAHARASHTRA | 400071 | Accepted-Technical Qualify |
| 2 | Accepted-Technical B 204 KAVITA KUNJ CHS MITHBUNDER ROAD KOPRI THANE E 400603 | THANE | THANE | MAHARASHTRA | 400603 | Accepted-Technical Qualify |
| 3 | Accepted-Technical 1 GANESH DARSHAN ADV SURVE MARG SANDHURST ROAD W MUMBAI 9 | MUMBAI | MAHARASHTRA | Accepted-Technical Qualify |
Tender Value
Refer Docs
Closing Date
3 Dec 2025, 5:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Central Mumbai Electrical Divis
Executive Engineer Central Mumbai Electrical Division Sadhana House 2nd floor, Pandurang Budhkar marg, Behind Mahindra Tower, Worli, Mumbai -18. Telephone 022 4564 6881
Providing Additions Alterations in HVAC System in the ditorium Hall at 7th floor of Administrative Building at Grant Govt. Medical College Sir J. J. Group of Hospital compound, Byculla, Mumbai.
2025_PWDM_1251109_1
Quatation/16/25-26/D/Auditor 2nd
Open Tender
Electrical Works
Item Rate
90 days
JJ Subdivision
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
3 Dec 2025
24 Nov 2025
3 Dec 2025
24 Nov 2025
1 Dec 2025
24 Nov 2025
Providing Evacuating set on site on rentle basis, Evacuuating R-410 from the VRF system, consits of 18 HP ODU in empty cylinder, disconnecting POWER supply of the ODU.
Discomnnecting the Control & Power supply wiring, copper piping with refnets, Removing the Cassette type Indoor unit from its existing location to vaccate the area for carrying out Falce ceiling grid work.
Supply, erection, testing & commissioning of ISI mark, PWD approved, 3 C X 2.5 Flexible Copper cable for Power supply of Indoor unit.
Supply, erection, testing & commissioning of ISI mark, PWD approved, 4 C X1.5 Flexible Copper cable for Control of Indoor unit.
Re-installation of the Indoor ints to new location with new GI 10 mm dia GI rods, nuts bolts etc as required with necessary supporting material connecting new copper pipes with sleeves, refnets joints power & control cable as per OEM's guidelines.
After reinstallation of all the Indoor units and doing necessary copper piping connection, carrying out flushing of the system with dry nitrogen, re pressure testing the 18 HP VRF Outdoor units by Nitrogen pressure, carrying out complete leak testing, checking & rectifying leakages if found, holding the pressure overnight to confirm no drop, vaccumising the syste, upto 500 microns, chrging the R 410 refrigerant to the system, carrying out testing, commissioning & oberving the performance.
Carrying out complete BDS service of all the 5 TR capacity Cassette Indoor units due to chocking up of Evap coils due to wooden ply cutting work by civil dept.
Carrying out spray painting of the Cassette Indoor Grills in Black Powder coating colour as instructed by EIC.
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
BOQ_2157189.xls
BOQ • 1.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .