Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.9 LAccepted-AOC NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹55.9 L+₹5.0 L (9.74%)Rejected-Finance NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 3 | L3₹56.9 L+₹6.0 L (11.7%)Rejected-Finance NO S 7 2ND CROSS 2ND MAIN KEB LAYOUT SANJAYANAGAR BANGALORE 560094 | BENGALURU URBAN | KARNATAKA | 560094 | L3 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 4 | L4₹59.3 L+₹8.3 L (16.3%)Rejected-Finance | L4 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 5 | L5₹60.5 L+₹9.5 L (18.7%)Rejected-Finance | L5 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
16 Dec 2024, 6:00 pmClosed
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli Bangalore 560013
REPAIR MAINT OF SUMMER APPLIANCES DG SETS AMF PANEL ELECTRICAL INFRASTRUCTURE LT PANEL EARTHING AND OTHER MISC WORKS AT AFS JALAHALLI EAST AND CQAE WE
2024_MES_685606_1
8984/E8
Open Tender
Electrical and Maintenance Works
Item Rate
241 days
Garrison Engineer M AF Jalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Garrison Engineer M AF Jalahalli
₹1 L
9 Jan 2025
25 Nov 2024
23 Dec 2024
25 Nov 2024
16 Dec 2024
9 Dec 2024
25 Nov 2024 - 2 Dec 2024
Amount
Removing the window/ split type AC of 1.5/ 2 ton capacity of any make from any location for carrying out servicing complete as and when directed and installing back at original location, testing and commissioning complete all as specified and directed. Note :- The rate of following operations deemed to be included in quoted rate :- a) Cleaning the body, evaporator and condenser with detergent, combing the pins and flushing with air blower b) Checking electrical connection, cleaning, Greasing, oiling, fan/blower motor, cleaning of air filter with blower c) Wrapping suction and discharge pipe with foam insulation and white roll ,changing drainage pipe when necessary d) The unit rate quoted by the tenderer inclusive for Removing, servicing, installation, commissioning and testing of all equipment’s, tools and plants, and back in on final position complete (e) The work shall be done by a specialized team of Engineer/Technicians of OEM. (f) Spares will be measured and paid separately. (g) Refrigerant gas shall be measured & paid separately under respective item of BOQ.
Supply and fixing Blower motor (in replacement) suitable for split type Air Conditioner of any make up to 2 TR capacity including taking down existing unserviceable one, complete all as specified and directed.
Supply and fix Suction valve suitable for 1.5 Ton/2 Ton of split type AC of existing make complete all as specified and directed.
Supply and fix discharge valve suitable for 1.5 Ton/2 Ton of split type AC including taking down existing one complete all as specified and directed.
Supply and fixing Condenser coil (in replacement) after disconnecting the refrigerant connection of defective condenser coil unit of split type AC upto 2.0 TR and replacing the condenser coil unit connecting the same unit with refrigerant connections complete including taking down existing one all as specified and directed.
Supply and fix polyurethane form insulation for indoor & outdoor unit suitable for 1.5 Ton to 2 Ton split type A/C any type and at any location including taking down existing one complete all as specified and directed.
Supply and fixing Remote sensing unit (in replacement) for upto 2.0 TR split type AC including taking down existing unserviceable one complete all as specified and directed.
Supply and fixing Remote assembly corded/cordless (in replacement) for any type and size of split type ACs, upto 2.0 TR including taking down existing one complete all as specified and directed.
Supply and fixing Blower of indoor unit suitable for 1.5 Ton / 2 Ton split AC including taking down existing unserviceable one at any location complete all as specified and directed.
Supply and fixing Condenser Fan motor (in replacement) suitable for window type Air Conditioner of any make up to and including 1.5/2.0 TR capacity, including taking down existing one and complete all as specified and directed.
Supply and fixing Hermetic sealed/Rotory new compressor for 2 TR split type AC capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of split type AC of capacity 2 Ton and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one complete all as specified and directed.
Supply and fixing Filter (in replacement) suitable for split type Air Conditioner of any make upto 2 TR capacity, including taking down existing one complete all as specified and directed.
Supply and fix Condenser coil (in replacement) after disconnecting the refrigerant connection of defective condenser coil unit of split type AC upto 1.5 TR and replacing the condenser coil unit connecting the same unit with refrigerant connections complete including taking down existing one all as specified and directed.
Supply and fix MS wall bracket suitable for fixing of out door unit of split type Air Conditioner with necessary nuts, bolts & washers and removing old unserviceable items and making good disturbed surfaces to match with the existing complete all as specified and directed.
Supply and fixing as in repair of Copper tubing of size 1/2" flare size conforming to relevant IS complete all as specified and directed.
Supply and fixing as in repair of Copper tubing of size 1/4" flare size conforming to relevant IS complete all as specified and directed.
Supply and fixing as in repair of Copper tubing of size 5/8" flare size conforming to relevant IS complete all as specified and directed.
Supply and fixing Front grill (in replacement) suitable for split type Air Conditioner of any make of 2 TR capacity, including taking down existing one all as specified and directed.
Supply and fixing as in repair of flexible PVC pipe of suitable size for indoor unit drain water of split AC suitable for any type and any capacity complete all as specified and directed.
Supply and fixing as in repair of Copper tubing of size 3/8" flare size conforming to relevant IS complete all as specified and directed.
Supply and fix Over load relay (in replacement) suitable for split type Air Conditioner of any make up to 2.0 TR capacity, including taking down existing one complete all as specified and directed.
Supply and fixing Hermetic sealed/Rotory new compressor for 1.5 TR split type AC capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of split type AC of capacity 1.5 Ton and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one complete all as specified and directed.
Supply and fix as in repair dummy nut of dia 3/8" suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and directed.
Supply and fix dummy nut of dia 1/4" suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and directed.
Supply and fix as in repair dummy nut of dia 5/8" suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and directed.
Supply and fix as in repair dummy nut of dia 1/2" suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and directed.
Supply and fix PCB board of any make for indoor unit of split AC 1.5 Ton/ 2 Ton including taking down existing one complete all as specified and directed.
Supply and fix old UNSV indoor unit including blower fan , PCB board and all accessories capacity 1.5/2.0 Ton split type A/C including taking down existing unserviceable one any type complete all as specified and directed.
Supply and fix as in repair PVC insulated multi stranded copper conductor 3 core 2.5 sq.mm, including connecting up and taking down existing unserviceable cable of any description and size complete all as specified and directed.
Material and labour for shifting of Air Conditioner, Split type capacity up to 2 TR from existing location to new location as per user requirement and installing, toping up of gas, replacement of copper tubing connecting up, commissioning and testing complete all as specified and as directed. Note :- The rate for following works deemed to be included in quoted rate :- (a) Transportation of air conditioner any type any capacity from one to other location. (b) Fixing only base plate with necessary fixing material on stone / brick walls as directed (c) Fixing only outdoor and indoor units as required and directed (d) Connecting indoor / outdoor units of split ACs with copper tubes, flairs nuts, warping suction and discharge lines with inclucating materials with necessary fixing arrangements such as bolts, nuts washers and clamps etc. on walls (e) fixing PVC pipes 50mm dia for outlet of outdoor units to drain out dew water with necessary clamps. (f) Fixing of wall mounting voltage stabilizer of 3 KVA to 5 KVA capacity on the wall with necessary fixing arrangements such as bolts, nuts washers and clamps etc on wall. (g) Fixing PVC hose/ PVC pipes of 15mm sizes as reqd at site with necessary junction boxes, PVC bends etc. including two length of PVC copper cables of 4 sqmm size for electrical connection of ACs. (h) No additional payment shall be made for leakage of gas occurring during shifting of Air Conditioner and topping up of required gas. (j) Fixing of copper tubing of qty of required size.
Supply and fix flair nut of dia 5/8" suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and as directed.
Supply and fix flair nut of dia 1/2" suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and as directed.
Supply and fix flair nut of dia 3/8" suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and as directed.
Supply and fix flair nut of dia 1/4" suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and as directed.
Supply and fix flair nut of dia 1/16" suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and as directed.
Supply and fix single phase single pole contactor suitable for 1.5/ 2.0 split type AC complete all as specified and as directed.
Removing old unserviceable split type air conditioner outdoor unit and deposited in store yard for safe custody and Supply and fix outdoor unit of the split type air conditioner 1.5/2 TR capacity, complete with all accessories such as hermetically sealed compressor and condenser unit, capacitors, relays, fan motor, duly prewired and including connecting of existing refrigerant gas piping, electrical connections and testing etc complete all as specified and directed.
Supply & fix metal clad switch socket single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A concealed in walls complete all as specified and as directed. Make : Havells/ Indo asian/ Legrand
Supply and fix 3 pin metal clad plug top 20 Amps, AC 230 volts for any type of AC including taking down existing unserviceable one complete all as specified and as directed.
Repair and maintenance of inverter type split AC of any capacity / any Make from any location including attending breakdown calls, routine maintenance and servicing ,testing and commissioning all as specified and directed here under :- a) Cleaning the body, evaporator and condenser with detergent, combing the pins and flushing with air blower. b) Checking electrical connection, cleaning, Greasing, oiling, fan motor, cleaning of air filter with blower. (c) Testing all copper tube ,joints, leads for any leaking and Top up with the refrigerant gas if necessary. (d) The work shall be done by a specialized team of Engineer/Technicians of OEM.
Supply and fix DC blower fan motor for inverter split AC of 1.5 Ton to 2 Ton and including taking down existing unserviceable one of any capacity and at any location complete all as specified and directed.
Inspection, checking adjustment and minor repair of unserviceable window type AC any type any capacity placed at any location includes repair/ replacement of defective parts such as checking of electrical connection, condenser, gas leakage, PCB, condenser fan blade, indoor unit, outdoor unit, compressor, PVC pipe etc., complete all as specified and as directed . Note :- Repair/ replacement of unserviceable parts shall be measured and paid separately complete all as specified and as directed .
Supply and fix Filter (in replacement) suitable for window type Air Conditioner of any make up to 1.5/ 2 TR capacity including taking down existing one complete all as specified and directed.
Supply and fixing PCB board of inverter type split type AC for 1.5 Ton/2 Ton including taking down existing unserviceable one at any location complete all as specified and directed.
Supply and fix condenser fan blade suitable for 1.5 Ton split/ window AC including taking down existing unserviceable one and complete all as specified and directed.
Material and labour for pressure testing and rectifying the leakages found in the system of window/ split type ACs capacity up to 2 Ton capacity including vacumizing, charging and checking the gas pressure to desire level complete for satisfactory functioning complete all as specified and directed. Note: Toping up of gas shall be measured and paid separately under respective item of BOQ.
Supply and fixing Thermostat (in replacement) suitable for window type Air Conditioner of any make of 1.5 TR capacity, including taking down existing one complete all as specified and directed.
Supply and fixing Blower motor (in replacement) suitable for window type Air Conditioner of any make of 1.5/ 2 TR capacity including taking down existing unserviceable one complete all as specified and directed.
Supply and fixing Over load relay (in replacement) suitable for window type Air Conditioner of any make up to and including 1.5/ 2 TR capacity, including taking down existing one complete all as specified and directed.
Supply and fixing Front grill (in replacement) suitable for window type Air Conditioner of any make up to 1.5 TR capacity, including taking down existing one complete all as specified and directed.
Supply and fixing Hermetic sealed/Rotory new compressor for window type AC of capacity 1.5 Ton (in replacement) including disconnecting the electrical and refrigerant connection of defective sealed unit of window type AC of capacity 1.5 Ton and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one complete all as specified and directed.
Supply and fixing Condenser coil after disconnecting the refrigerant connection of defective condenser coil unit of window type AC up to and including 1.5/ 2 Ton and replacing the condenser coil unit connecting the same unit with refrigerant connections complete including taking down existing one complete all as specified and directed.
Supply and fix overload protector for window/ split AC 1.5/2 Ton TR capacity including taking down existing unserviceable one complete all as specified and directed.
Taking out, inspection, checking adjustment and minor repair of unserviceable water cooler 40/80/60/120/150/180 ltr capacity of any type any make for repair/ replacement of defective parts such as condenser, PVC pipe, loose water tap, float valve, loose electrical connection etc., cleaning condenser unit of foreign particle and descaling with carbon di oxide gas to ensure smooth flow of water cooler gas, reassembling the appliance, testing and placing in original position complete all as specified and as directed . Note :- Repair/ replacement of unserviceable parts shall be measured and paid separately complete all as specified and as directed .
Material and labour for pressure testing and rectifying the leakages found in the system of water cooler of capacity 150 litres and vacuuming and charging refrigerant gas and filling new compressor oil etc. complete for satisfactory functioning all as specified and directed. Note:Topping up of gas shall be measured and paid separately
Supply and fixing Door gasket (in replacement) suitable for lid of water cooler up to 150 litres capacity, complete all as specified and directed.
Taking down corroded bottom portion of water cooler of 150 litres capacity and provision of 14 gauge MS sheet with suitable size angle iron frame work duly welded to the body of the water cooler including two coats of synthetic enamel painting over a coat of red oxide primer to match the existing colour all as specified and directed.
Supply and fixing Electric condenser Fan motor, AC 230 volt, single phase with recommended RPM etc. (in replacement) suitable for water cooler of any make of 150/180 litres capacity, complete all as specified and directed.
Supply and fix Stainless steel tray (in replacement) suitable for water cooler of 150 Litres capacity complete all as specified and directed.
Supply and fixing hermetic sealed new compressor (in replacement) for water cooler 150 litre/Hr cooling capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 150 litres and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one all as specified and directed.
Material and labour for preparing the old painted surface of the water coolers of capacity 150 Litres and spray painting with synthetic enamel paint over one coat of red oxide primer including replacement of worn out nut, bolt, washer, screw and writing MES No and capacity all as specified and directed.
Supply and fixing ball brass valve high pressure 15mm dia complete fitting such as PVC polythene ball, layer check nut washer etc for water cooler of any capacity including taking down existing one all directed.
Supply and fix in replacement of gun metal gate valve 15mm dia including GI nipple including taking down existing one all as specified and as directed
Supply and fixing Electric condenser Fan motor, AC 230 volt, single phase with recommended RPM etc. (in replacement) suitable for water cooler of any make of 60/120 litres capacity, including taking down existing one all as specified and directed.
Supply and fixing PVC drain out pipe 30mm dia bore (in replacement) as per existing including providing necessary GI clamps, nut bolt etc.all as specified and directed
Supply and fixing hermetic sealed new compressor (in replacement) for water cooler 60/120 ltr/Hr cooling capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 60/120 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed.
Supply and charging of refrigerant gas R-134a to water cooler, refrigerator and deep freezer air conditioner of any type, make and capacity all as specified and directed. (i) Empty cylinder shall be returned to contractor. (ii) Payment shall be made for net weight of gas filled.
Material and labour for repairing the leakage in the steel water tank of water cooler of any capacity by welding brazing/ soldering complete all as specified and directed.
Material and labour for pressure testing and rectifying the leakages found in the system of water cooler of capacity 60/120 litres and vacuuming and charging refrigerant gas and filling new compressor oil etc. complete for satisfactory functioning all as specified and directed. Note: Topping up of gas shall be measured and paid separately
Supply and fixing Self closing push type Bib tap 15mm dia made out of cast copper alloy chromium plated (in replacement) suitable for water cooler conforming to ISI , including testing and leak proof etc. complete all as specified and directed.
Material and labour for pressure testing and rectifying the leakages found in the system of water cooler of capacity 40/ 80 litres and vacuuming and charging refrigerant gas and filling new compressor oil etc. complete for satisfactory functioning all as specified and directed. Note: Topping up of gas shall be measured and paid separately
Supply and fix Stainless steel tray (in replacement) suitable for water cooler of 40/ 80 litres capacity all as specified and directed.
Supply and fixing hermetic sealed new compressor (in replacement) for water cooler 40/80 ltr/Hr cooling capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 40/80 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed.
Taking down corroded bottom portion of water cooler of 40/80 litres capacity and provision of 14 gauge MS sheet with suitable size angle iron frame work duly welded to the body of the water cooler including two coats of synthetic enamel painting over a coat of red oxide primer to match the existing colour all as specified and directed.
Supply and fixing Condensing coil suitable for water cooler of capacity 40/80 ltr/hr cooling capacity (in replacement) complete all as specified and as directed.
Supply and fixing Multi layer capacitors 45 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed.
Supply and fixing Multi layer capacitors 6 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed.
Supply and fixing Evaporator coil suitable for water cooler of capacity 40/80 ltr/hr cooling capacity (in replacement) complete all as specified directed.
Supply and fixing Electric condenser Fan motor, AC 230 volt, single phase with recommended RPM etc (in replacement) suitable for water cooler of any make of 40/80 litres capacity, complete all as specified and as directed.
Material and labour for preparing the old painted surface of the water coolers of capacity up to 40/80 Litres and spray painting with synthetic enamel paint over one coat of red oxide primer including replacement of worn out nut, bolt, washer, screw and writing MES No and capacity complete all as specified and as directed.
Supply and fix in replacement of filter for water cooler of any size any make complete all as specified and as directed.
Supply and fixing Carbon (filter) 12” size incl taking down old unsv complete all as specified and as directed.
Taking out, inspection, checking adjustment and minor repair of unserviceable refrigerator 165/175/180/185/190/260/277/286/290/308/310/315/350/360/375 ltr capacity of any type any make for repair/ replacement of defective parts such as condenser, PVC pipe, loose electrical connection etc., cleaning, condenser unit of foreign particle and descaling with carbon di oxide gas to ensure smooth flow of refrigerating gas, reassembling the appliance, testing and placing in original position complete all as specified and as directed . Note :- Repair/ replacement of unserviceable parts shall be measured and paid separately complete all as specified and as directed .
Material and labour for pressure testing and rectifying the leakage found in the system of refrigerator of capacity 308 to 350 litres including vacuuming and charging the refrigerant gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning complete all as specified and directed. Note: Topping up of gas shall be measured and paid separately
Supply and fixing Evaporator coil, suitable for refrigerator of 260 to 308 ltrs any make size and type (in replacement) complete all as specified and as directed.
Material and labour for Freezer compartment including door and accessories suitable for refrigerator 260, 286,308, 315 and 350 ltrs capacity refrigerator and including taking down existing unserviceable one complete all as specified and as directed.
Supply and fixing in replacement condensing coil for refrigerator of capacity 308 to 350 Ltr complete all as specified and directed.
Supply and fixing Evaporator coil, suitable for refrigerator of 308 to 350 ltrs any make size and type (in replacement) complete all as specified and directed.
Supply and fixing in replacement condensing coil for refrigerator of capacity 260 to 308 Ltr complete all as specified and directed.
Supply and fixing Chiller tray (in replacement) suitable for Refrigerator of any make, 260 to 308 litres capacity, complete all as specified and directed.
Supply and fixing superior quality plastic/PVC Ice cube tray for refrigerator of capacity 260 Ltrs to 308 ltrs complete all as specified and directed.
Supply and fixing Vegetable tray (in replacement) suitable for Refrigerator of any make, 260 to 308 litres capacity, complete all as specified and as directed.
Supply and fixing PVC shelf transparent type of tough plastic suitable for refrigerator of capacity 260 to 308 ltrs complete including taking down existing unserviceable one complete all as specified and directed.
Supply and fixing hermetically sealed new compressor (in replacement) for 308 to 350 Ltr capacity of refrigerator including filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 308 to 350 litres complete all as specified and as directed.
Material and labour for pressure testing and rectifying the leakage found in the system of refrigerator of capacity 260 to 308 litres including vacuuming and charging the refrigerant gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning complete all as specified and as directed. Note:Topping up of gas shall be measured and paid separately
Supply and fix in repair electric bulb 15/20 watt 230v threaded type for refrigerator of Capacity 260 ltrs to 308 ltrs complete all as specified and directed.
Supply and fixing hermetically sealed new compressor (in replacement) for 260 to 308 Ltr capacity of refrigerator including filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 260 to 308 litres complete all as specified and directed.
Supply and fixing Chiller tray (in replacement) suitable for Refrigerator of any make, 165 to 260 litres capacity, all as specified and directed.
Supply and fixing hermetically sealed new compressor (in replacement) for 165 to 260 Ltr capacity of refrigerator including filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 165 to 260 litres complete all as specified and directed.
Material and labour for pressure testing and rectifying the leakage found in the system of refrigerator of capacity 165 to 260 litres including vacuuming and charging the refrigerant gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning complete all as specified and directed. Note:Topping up of gas shall be measured and paid separately
Supply and fixing Evaporator coil, suitable for refrigerator of 165 to 260 ltrs any make size and type (in replacement) complete all as specified and directed.
Supply and fix in repair magnetic beading for refrigerator of cap 165 ltrs to 335 ltrs complete all as specified and directed.
Supply and fixing in replacement condensing coil for refrigerator of capacity 165 to 260 Ltr complete all as specified and directed.
Supply and fixing Relay, box type, suitable for refrigerator of any make 165 to 335 litres capacity (in replacement) fixed in repairs, complete all as specified and directed.
Supply and fixing Vegetable tray (in replacement) suitable for Refrigerator of any make, 165 to 260 litres capacity, complete all as specified and directed.
Supply and fixing Freezer compartment including door and accessories suitable for refrigerator 165/175 ltrs capacity refrigerator and including taking down existing one complete all as specified and directed.
Material and labour for preparing the old painted surface of refrigerator of capacity 165 litres to 350 litres and spray painting with synthetic enamel paint of approved colour complete all as specified and directed.
Supply and fixing Multi capacitors 2 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed.
Supply and fixing Thermostat, suitable for refrigerator of any make 165 to 350 litres capacity (in replacement) all as specified and directed.
Servicing the Voltage Stabilizer 0.5 KVA/2KVA single phase after replacing transformer, PCB,u/s electronic parts, setting/testing of buck/boost relay, assemble back & fixing in its original position including testing for proper functioning complete all as specified and as directed.
Servicing the Voltage Stabilizer 4 KVA to 5 KVA single phase after replacing transformer, PCB,u/s electronic parts, setting/testing of buck/boost relay, assemble back & fixing in its original position including testing for proper functioning complete all as specified and as directed.
Supply and fixing Copper capillary tube suitable for refrigerator including taking down existing unserviceable one, any description complete all as specified and directed.
Supply and fixing Timer and sensor of Refrigerator including taking down existing unserviceable one complete all as specified and as directed .
Supply and fixing Filter of refrigerator including taking down existing unserviceable one complete all as specified and as directed.
Supply and fixing in replacement Gasket, suitable for door of Refrigerator of any make, 165 to 350 litres capacity, fixed in repairs all as specified and directed.
Supply and fixing Multi layer capacitors 4 µfd for cooling appliances including taking down existing unserviceable one all as specified and as directed.
Supply and fixing Multi layer capacitors 2.5 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed.
Supply and fixing Copper capillary tube of Deep freezer including taking down existing unserviceable one, any description complete all as specified and as directed.
Material and labour for pressure testing and rectifying the leakage found in the system of Deep freezer of capacity 405 litres including vacuuming and charging the refrigerant gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning all as specified and as directed. Note:Topping up of gas shall be measured and paid separately
Supply and fixing Over load protector for refrigerator including taking down existing unserviceable one any description complete all as specified and as directed..
Supply and fixing Starting relay suitable for refrigerator including taking down existing unserviceable one complete all as specified and as directed
Supply and fixing Thermostat for Deep freezer including taking down existing unserviceable one complete all as specified and as directed.
Supply and fixing hermetic sealed new compressor (in replacement) 1/6 HP suitable for deep freezer of capacity 405 ltr including disconnecting the electrical and refrigerant connection of defective sealed unit of deep freezer 405 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed
Supply and fixing Starting relay of Deep freezer including taking down existing unserviceable one complete all as specified and as directed.
Supply and fixing Filter for Deep freezer including taking down existing unserviceable one complete all as specified and as directed
Supply and fixing Condenser fan motor of Deep freezer including taking down existing unserviceable one complete all as specified and as directed.
Supply and fixing Over load protector for Deep freezer including taking down existing unserviceable one, any description complete all as specified and as directed.
Material and labour for taking down of ceiling fan of size 1200/1400mm sweep for safety checking by replacing defective parts/painting/rewinding and re-fixing the ceiling fan after repairs, all as specified and as directed by Engr-in-charge. (Note:- The replacement of unserviceable items like capacitor, Bearings, Bush, Canopy, down rod etc. shall be made as directed which will be measured and paid separately under respective items as Supply only. However, parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional and making connection by replacing PVC insulated unsheathed cable of copper conductor of size 1.5 Sqmm from ceiling rose/ connector fan (minimum 0.50 Mtr length) including cost of labour for above replacement are deemed to be inclusive in quoted rate all as directed.
Note:- The following items shall be deemed to be inclusive in the unit rate quoted against Sl Item No 129 (a) In each job, checking the functioning of fan including its connections, cleaning of fan, greasing of fan and mechanical check i.e. tightening of loose screw, nuts, bolts, etc are inclusive in unit quoted rate.
(b) The above job shall be carried out by a trained electrician having qualified in ITI ( electrician Trade), documentary proof of the education of tradesman shall be produced to the Engr-in- Charge, before commencement of work.
(c) Replacement of unserviceable parts like rubber bush, clamps, bolts, nuts, washers, safety pin, bearing etc will be paid under respective item here-in-after as supply only through proper documentation.
(d) The entire job shall be carried out in Air Force stn Jalahalli
(e) Necessary T&P such as ladder, required manpower for taking down and refixing after repair shall be of contractor's responsibility.
(f) All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department.
(g) Any fan found defective/not working shall be brought to AGE E/M store yard & re-fixed after repairing.
(j) In case of major defects, entire job shall be completed within 10 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered.
(k) In case of minor defects, entire job shall be completed within12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered.
Supply only fan bearing suitable for ceiling fan 1200mm /1400 mm sweep (bearing with 8 balls shall be used ) Make:- NBC/TATA/SKF
Supply only Rubber reel bushes for ceiling fan of size 1200/1400mm sweep complete all as specified and directed.
Supply only outer body of ceiling fan of any size complete all as specified and directed.
Supply only steel screw (for fixing of fan blade) as per site requirement for any make of ceiling fan complete all as specified and directed.
Supply only gun metal bush of suitable size for ceiling fan 1200mm /1400 mm sweep complete all as specified and directed.
Supply only rotor of ceiling fan of any size complete all as specified and directed.
Supply only down rod for ceiling fan with 15mm dia (of length not less than 90cm and not more than 120cm) with hanging clamps for ceiling fan complete all as specified and directed.
Supply only down rod for ceiling fan with 15mm dia (of length not less than 45cm and not more than 60cm) with hanging clamps for ceiling fan complete all as specified and directed.
Supply only fan canopies for ceiling fan size of 1200mm/1400mm sweep complete all as specified and directed.
Supply only down rod for ceiling fan with 15mm dia (of length not less than 180cm and not more than 210cm) with hanging clamps for ceiling fan complete all as specified and directed.
Supply only 'U' clamp for hanging ceiling fan with all nuts, bolts and washers complete all as specified and directed.
Supply only blades (made of aluminium) suitable for 1400mm sweep ceiling fan of any make with set of screws complete all as specified and directed.
Supply only safety cotter pins 40mm to 50mm long with nuts and bolt with washers for ceiling fan of size 1200/1400mm sweep complete all as specified and directed.
Supply only blades (made of aluminium) suitable for 1200mm sweep ceiling fan of any make with set of screws complete all as specified and directed .
Supply and fixing in replacement of unserviceable Ceiling fan 1200mm sweep, energy efficient ISI marked with star rating 230 Volts AC 50 Hz, single phase including provision of fixing arrangement, nut and bolt and flexible 3 core of size 1.5 sqmm not less than 0.5 m long complete including taking down existing one, writing MES No with synthetic enamel paint complete all as specified and directed. Make : Havells/ Bajaj/ Orient/USHA. Note:- (a) Old Unserviceable ceiling fan shall be deposited to MES store yard.
Material and labour for winding of ceiling fan motor 1200 mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size not less than 0.75 mm of length not more than one meter with each fan complete all as specified and directed. (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule. (ii) taking down of fan, and re hanging measured under item No. 129 separately.
Material and labour for winding of ceiling fan motor 1400 mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size not less than 0.75 mm of length not more than one meter with each fan complete all as specified and directed. (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule. (ii) taking down of fan, and re hanging measured under item No.129 separately.
Inspection, checking adjustments and minor repairs of storage water heater 25/50 ltr capacity of any type any make vertical/ horizontal type cmprising of the following :- (a) Inspection, taking out of drain plug & dewatering and re-fixing the same complete all as directed . (b) Checking water tightness of storage tank . (c) Checking stop cocks with outlet/inlet pipe of geysers, pressure reducing valves etc to ensure free movement of water and easy functioning of parts. (d) Inspecting over flow vent pipe connections to ensure water-tightness and proper flow. (e) Checking and correct earth continuity of electrical items. (f) Checking functioning of heating element and correct setting adjustment of thermostat. (g) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. (h) Replacement of defective spares shall be measured and paid under relevant items mentioned below separately as supply and fix.
Note : The following deemed to be inclusive in quoted rate :-
The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced to the Engr-in-Charge before commencement of work.
In case of major defects, entire job shall be completed within 15 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered.
In case of minor defects, entire job shall be completed with in 12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered.
The entire job will be carried out in entire area of Air Force stn Jalahalli
All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department.
Supply and fixing Heating element 1.5 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers any type and any make including taking down old one including washer/ packing suitable complete all as specified and as directed.
Supply and fixing PVC connection for hot/ cold water made of double layer nylon braided and fabric at a pressure of 6kg/sq cm at both ends, 450 mm long, heavy duty with CP brass adopters, washers, suitable for 15 mm bore pipe including taking down existing one complete all as specified and as directed.
Supply and fixing in replacement pressure relieving valve CP brass confirming to relevant IS with washer suitable for 15mm bore GI pipe suitable for 25/50 ltrs geysers complete all as specified and as directed.
Supply and fixing in replacement thermostat switch range of 30-80 degree celsius suitable for geysers of 25/50 ltrs capacity (ISI marked) complete all as specified and as directed.
Material and labour for Cutting and screwing existing steel water tubing 15/20/25 mm bore for addition /alteration required for connections to geysers etc including taking down existing one complete all as specified and directed.
Supply and fixing Heating element 2.0 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any capacity ,any type and any make including taking down old one including washer/ packing suitable complete all as specified and as directed.
Supply and fixing in replacement bottom cover of MS sheet 20 gauge suitable for 25 ltrs capacity geysers and providing a coat of red oxide to inner surface and applying one coat of synthetic enamel paint by spray painting to outer surface complete all as specified and as directed.
Supply and fixing in replacement brass non return valves, screwed down, high pressure, screwed both ends for 15mm bore iron pipe or for union, ISI marked, complete all as specified and as directed.
Supply and fixing Outer body of MS sheet not less than 20 gauge suitable for 25 ltr geyser with white synthetic enamelled paint including taking down existing one complete all as specified and as directed.
Material and labour for Grouting 4 Nos of M12 X100mm bolt in stone /brick masonry wall with 1:4 CM suitable for hanging geysers complete all as specified and as directed.
Supply and fixing Indicator lamp for geyser 25/50 ltr capacity of colour green & red complete all as specified and as directed.
Taking down carefully storage water heater (geyser) 25 ltr capacity of any type, any make from the location by removing the electric & water supply connection and shifted to work shop/MES store yard for repair and re-installation at any location including Supply and fixing in repair of heavy duty pin type fastener 4" long and making necessary inlet/outlet electric & water supply connection from existing source to geyser complete all as specified and as directed. Note :- Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness.
Taking down carefully storage water heater (geyser) 50 ltr capacity of any type, any make from the location by removing the electric & water supply connection and shifted to work shop/MES store yard for repair and re-installation at any location including Supply and fixing in repair of heavy duty pin type fastener 4" long and making necessary inlet/outlet electric & water supply connection from existing source to geyser complete all as specified and as directed. Note :- Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness.
Material and labour for painting of outer surface of 50 ltrs storage type water geysers after cleaning of dust & other organic/inorganic materials if any and applying one coat of synthetic enamel white paint by spray painting and writing MES No. on the geyser complete all as specified and as directed.
Supply and install water heater storage type (Geyser) vertical of capacity 25 Ltr, suitable for high pressure up to 8 bar powder coated metal body, temperature indicating dial , glass line coated tank, magnesium anode, efficient long life copper heating element, wattage 2 KW electrically operated, AC 230 Volt, BEE 5 Star Rated with complete fittings/parts and accessories for fixing on wall/surface all as per site requirement and specified and directed Make:- Bajaj / Racold / Havells
Material and labour for painting of outer surface of 25 ltrs storage type water geysers after cleaning of dust & other organic/inorganic materials if any and applying one coat of synthetic enamel white paint by spray painting and writing MES No on the geyser complete all as specified and as directed.
Dismantling carefully solar storage water heating system of 100/200/300 Ltr capacity any type for following works with testing and refixing the same in original position making all water/ electric connection to entire satisfaction of Engineer-in-charge after repair as under :-(a) Inspection, opening, of all parts, descaling, washing of inner tank with chemical solution and cleaning of outer cover storage tank. (b) Checking water tightness of storage tank after cleaning. (c) Checking and correcting earth continuity of electrical items. (d) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. (e) Replacement of damaged solar cells (f) Necessary T&P such as ladder, helper shall be contractor's responsibility.
Note : The following deemed to be inclusive in quoted rate :-
The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced to the Engr-in-Charge, before commencement of work.
In case of major defects, entire job shall be completed within 15 days from the date of registration of complaint, failing which penalty charges @ Rs. 500/- per day shall be recovered.
In case of minor defects, entire job shall be completed with 12 hrs from the time of registration of complaint, failing which penalty charges @ Rs. 100/- per job shall be recovered.
The entire job will be carried out in entire area of Air Force stn Jalahalli
Necessary T&P such as ladder, helper shall be contractor's responsibility.
All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department.
Supply and fixing in replacement bib taps, cast copper alloy, with crutch or butterfly handle, chromium plated, fancy type, screwed down, screwed for 15mm bore iron pipe, ISI marked, complete all as specified and as directed.
Supply and Fix in replacement of solar water heater tank 100 ltr capacity tank should be 1.60 mm thickness low carbon steel with porcelain coating, outer tank should be 0.4 mm thickness stainless steel 202 grade Non Magnetic grade, insulation in PUF 50mm including provn for suitable solar tubes complete all as specified and directed. Note :- Solar tubes shall be measured and paid separately
Supply only solar cells to replace the damaged cells in the solar panel for solar water heater 200 Ltr capacity complete all as specified and directed.
Supply only solar cells to replace the damaged cells in the solar panel for solar water heater 100 Ltr capacity complete all as specified and directed.
Supply and replace solar panel glass suitable for 100 ltrs capacity solar water heater with gasket complete all as specified and directed.
Gasket set for solar water heater panel suitable for 100Ltr capacity complete all as specified and directed.
Supply and fixing in replacement thermostat switch suitable for solar water heater of any make and size complete all as specified and as directed.
Supply and replacement of solar tube as per existing type complete all as specified and directed.
Supply and fixing Stop valves, 15 mm bore of pipe fancy type, chromium plated , high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
Supply and fix in replacement rotational moulded poly ethylene water storage tank of 300 litres capacity three layered HDPE water storage tanks cylindrical vertical with closed top as per IS 12701-1996 hoisted and fixed in position, including provn of inlet pipe, over flow pipe, washout pipe etc complete all as specified and directed.
Material and labour for Staging / steel frame work for Solar water tanks using standard mild steel sections like angle iron / MS pipe / flat iron / sheets etc using steel of Fe 410-W (Gde E-250) quality - A including necessary welding suitable to keep 300 ltrs PVC water tank in repairs complete all as specified and directed.
Taking down of exhaust fan any size/capacity after disconnecting cable connection, and refixing same in original position after necessary repair/over hauling including replacement of parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional and making connection by replacing PVC insulated unsheathed cable of copper conduct of size 1.5 Sqmm from ceiling rose/ connector fan (minimum 0.50 Mtr length) are deemed to be inclusive in quoted rate all as specified and as directed. (Note:- Rewinding, and materials to be replaced are measured separately.)
(a) The above job shall be carried out by a trained electrician having qualified in ITI ( electrician Trade), documentary proof of the education of tradesman shall be produced to Engr-in-Charge before commencement of work.
(b) Defective unserviceable part like fan bush, bearing etc. will be paid under respective item here-in-after as supply only through proper documentation.
(c) The entire job will be carried out in Air Force stn Jalahalli
(d) Necessary T&P such as ladder, helper shall be contractor responsibility.
(e) All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department.
(f) Any fan found defective/not working shall be brought to AGE E/M store yard & re-fixed after repairing.
(g) In case of major defects, entire job shall be completed within 10 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered.
(h) In case of minor defects, entire job shall be completed with 12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered.
Supply only 3.15 mfd capacity exhaust fan condenser complete all as specified and directed.
Supply only metal louvers of suitable size for exhaust fan of the 450mm sweep complete all as specified and directed.
Supply only fan bush of suitable size for exhaust fan of any sweep complete all as specified and directed.
Supply only metal louvers of suitable size for exhaust fan of the 300mm sweep complete all as specified and directed.
Supply only 4 mfd capacity ceiling /exhaust fan condensers complete all as specified and directed.
Supply only fan bearing of suitable size for exhaust fan of 300mm sweep including greasing complete all as specified and directed.
Supply only fan bearing of suitable size for exhaust fan of 450mm sweep including greasing complete all as specified and directed.
Supply only metal louvers of suitable size for exhaust fan of the 250mm sweep complete all as specified and directed.
Supply only 2.5 mfd capacity ceiling /exhaust fan condensers complete all as specified and directed.
Supply only fan bearing of suitable size for exhaust fan of 250mm sweep including greasing complete all as specified and directed.
Supply and fixing Exhaust Fan 300 mm sweep, 230/240 volt AC single phase, heavy duty, 1400 RPM, corrosion less mild steel body of motor, including necessary cutting, making holes on stone/brick walls where required, fixing arrangement with MS pipe 350 mm dia of required length to protect the shape of stone masonry, suitable hold fast with necessary nut, bolts / screws with louver including taking down existing one,writing MES No. with synthetic enamel paint all specified and directed. Make- Havells /Bajaj/ Almonard. Note:- Old Unserviceable domestic exhaust fan shall be deposited to MES store yard.
Supply and fixing Exhaust fan 250 mm sweep 230/ 240 volt AC single phase PVC body 1400 RPM including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make-Havells /bajaj/ Crompton Greaves. Note:- Old Unserviceable Exhaust fan shall be deposited to MES store yard.
Supply and fixing Exhaust fan 300 mm sweep 230/ 240 volt AC single phase PVC body 1400 RPM including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make-Havells /bajaj/ Crompton Greaves. Note:- Old Unserviceable Exhaust fan shall be deposited to MES store yard.
Material and labour for winding of Exhaust fan 250 mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 250 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size not less than 0.75 mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule.
Material and labour for winding of Exhaust fan 300 mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 250 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size not less than 0.75 mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule.
Material and labour for winding of Exhaust fan 450 mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 250 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule.
Taking down of wall mounted fan 400/450 size/capacity after disconnecting cable connection, and refixing same in original position after necessary repair/over hauling . (Note:- Repair, rewinding, over hauling and materials to be replaced are measured separately.)
Supply only fan bush of suitable size for wall mounted fan of the any sweep complete all as specified and directed.
Supply only fan bearing of suitable size for wall mounted fan of 400 mm sweep complete all as specified and directed.
Material and labour for winding of wall mounted fan 400 mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of sizenot less than 0.75 mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule.
Material and labour for winding of wall mounted fan 450 mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size not less than 0.75 mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule.
Taking down aluminium/copper point wiring on & including hard wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete (Taking down of fittings such as switches, sockets, bells, ceiling rose, holders , regulators, light fittings, MCB, lamps etc shall be measured and paid separately) and making good the disturbed plaster surfaces of wall, floor, ceiling and painting 2 coat of white wash/distemper to meet the existing surface and removing materials and debris to reinstate the premise neat and clean complete all as specified and directed.
Supply and fixing in repair 20 mm dia Chlorinated PVC (CPVC) Pipes of pressure rating of pressure rating 10kgf/cm2 including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed.
Supply and fixing in repair Chlorinated PVC (CPVC)Gate Valve of size 20 mm dia, (ISI marked) complete all as specified and as directed.
Supply and fixing in repair 25 mm dia Chlorinated PVC (CPVC) Pipes of pressure rating 10kgf/cm2 including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed.
Supply and fixing in repair Chlorinated PVC (CPVC) Gate Valve of size 25 mm dia,( ISI marked) complete all as specified and as directed.
Material and labour for Painting with two coats of synthetic enamel paint over coat of zink chrome on surfaces of any description, over 10cm in width or girth,not otherwise described complete all as specified and directed.
Supply only Regrigerant gas R-407C/R32/R410A in manufacturer's sealed cylinder complete all as specified and as directed. (i) Empty cylinder shall be returned to contractor. (ii) Payment shall be made for net weight of gas filled.
Material and labour in repairs for point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade ISI 694 marked cable for phase & neutral drawn through surface PVC conduit/ existing concealed PVC Conduit, ISI marked with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed. Make of Conduit : Avon Plast/ Supreme/ Diplast Make of Wire : Plaza/ Polycab/ Havells Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separately).
One light point/fan/bell point controlled by one switch
All as per item No. 235 here in before but for one 3 pin socket out 5 Amp on the same board
All as per item No. 235 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 235 above but wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15Amp switch socket independently
Material and labour in repairs for point wiring complete with 1.5 sqmm single core PVC insulated, unsheathed fire retacable 1100 volts grade, multi stranded with copper conductor drawn through and incl surface PVC Conduit/ existing concealed conduit with accessories in wall/roof/ceiling etc incl MS modular terminal boxes, concealed surface to walls covered with modular plates with cover etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for Make of Cable : Plaza/ Polycab/ Havells Make of Conduit : Supreme/ Diplast/ Avon Plast Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely).
One light point/fan/bell point controlled by one switch
All as per item No. 240 here in before but for One 3 pin socket out 5 Amp on the same board
All as per item No. 240 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 240 above but wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15Amp switch socket independently
Supply and Fix switch piano flush type 5 Amps 240 volts single pole one way. Make : Anchor, Havells, L&T, Indoasian
Supply and Fix switch piano flush type 15 Amps 240 volts single pole one way. Make : Anchor, Havells, L&T, Indoasian
Supply and Fix shuttered socket outlet 3 pin 5 Amps, flush type Make : Anchor, Havells, L&T,Indoasian
Supply and Fix shuttered socket outlet 2 in 1, 3 pin, 5 and15 Amps Make : Anchor, Havells, L&T,Indoasian
Supply and fix Modular switch 1 way 6A, 1 module complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor/Indoasian
Supply and fix Modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian
Supply and Fix modular switch 1 way 16 Amp.1 module. Make : Legrand/ Crabtree/ Anchor/Indoasian
Supply and Fix modular Socket, 16A - 2/3 pin combined 2 module. Make : Legrand/ Crabtree/ Anchor/Indoasian
M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 2 runs of 4 Sqmm drawn through in and incl suitable size surface PVC Conduit /concealed conduit and all accessories fixed to wall/floors along with 4 Sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and directed. Note: (a) 2 runs of 4 Sqmm cable along with one run of 4 Sqmm cable for earth conductor shall be measured as one length . (b) Connections of cables with MCBs or bus bars shall be done through appropriate size copper thimbles. Make:- Havells/ Plaza/Polycab
Supply and Fixing in repairs of 4 feet surface mounted battern type luminaire , lumen output of 2000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant . The luminaire shall have Class-1 Electrical insulation, Class-B serviceability . Test Report to be submitted from any govt of India approved lab , The luminaire and driver shall be BIS approved with "R" number mentioned will submitted at time of delivery, complete all as specified and directed. Make : Philips/ Bajaj / CG/Havells.
Supply and Fixing in repairs of 4 feet surface mounted battern type luminaire , lumen output of 1000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant . The luminaire shall have Class-1 Electrical insulation, Class-B serviceability . Test Report to be submitted from any govt of India approved lab , The luminaire and driver shall be BIS approved with "R" number mentioned will submitted at time of delivery, complete all as specified and directed. Make : Philips/ Bajaj / CG/Havells.
Servicing/ Periodical maintenance of following capacity DG Set of any make consisting of complete servicing and checking entire system as per manufacturer's catalogue including testing complete with replacing of minor consumables items like grease, nut bolts etc during conducting periodic servicing as per the manufacturer's recommendation at the time of routine monthly checks. Capacity 20 KVA DG Set - Location :-street lights CQAE Area - 01 No Maintenance Schedule of DG Sets :- The contractor shall carried out following activity during of the period of contract :-
(a) Daily maintenance of DG Sets to be carried out :-
(i) Clean the external surface of the DG set.
(ii) Check engine oil level.
(iii) Check engine coolant level.
(iv) Check fuel in the tank.
(v) Check all nuts and bolts.
(vi) Check tension of fan belts.
(vii) Check batteries and battery connections.
(viii) Check fuel lines and fuel tank.
(b) Weekly maintenance of AMF Panels :-
(i) Checking all electrical connections.
(ii) Checking all contact points/ Bus bars.
(iii) Checking timers (AC/ DC).
(v) Check RPM, Voltage, Amps and Hz.
(vi) Checking indicator lamps.
(vii) Checking main auxiliary contacts and relays.
(viii) Checking contact coils.
(ix) Checking, volt/ amps/ energy/ PF/ KWH meters/ CT's.
(x) Checking auto/ manual functions.
(xi) Check and tight screws and bolts.
(xii) Check battery charger output voltage.
(xiii) Cleaning the panel.
(xiv) Checking all MCCB's and fuses.
(xv) Checking alarms and hooter.
(c) Monthly maintenance of DG Sets to be carried out :-
(i) Check oil bath cleaner oil level.
(ii) Check for proper tension in the belts.
(iii) Check starting battery electrolyte level and specific gravity.
(iv) Check the fuel lines from the tank for leakages.
(v) Check the end cover of the alternator and tighten the bolts.
(vi) Check physically the exhaust silencer for rigidness.
(vii) Check the water hoses for leakages if any.
(viii) Drain sediment from fuel filter & fuel tank.
(ix) Check dry type air filter element and clean.
(x) Check engine alternator coupling and mounting bolts.
(xi) Tight all bolts and nuts in alternator terminal box.
(xii) Check for any unusual sound during cranking of the engine.
(xiii) Check for any fuel/ water leakages.
(xiv) Check for any unusual vibrations.
(xv) Check proper charging of battery.
(xvi) Check exhaust system for any leakages.
(xvii) Check for proper circulation of coolant/ cooling of engine.
(xviii) Check physically the exhaust silencer for rigidness.
(xix) Check throttles linkage.
(xx) Checking to electric control panel throttle linkage.
(xxi) Supply and greasing to all bearing & movable parts.
(d) Quaterly Schedule to be carried out :-
(i) Checking of hydraulic governor oil level and toping up level.
(ii) Clean the crank case breather.
(iii) Check battery charging system & topping up electrolyte and maintenance of specific gravity.
(iv) Checking electric connection & generator control panel.
(v) Greasing to all bearing and movable parts.
Note :- The unit rate quoted is deemed to be inclusive of the followings :-
(a) DG Sets are placed at various locations of CQAE (WE). Therefore,the bidders are advised to visit the location of DG Sets before quoting the tender.
(b) Servicing/ repair of DG Set shall be carried out by authorised dealer/ agency of manufacturer as approved by Engineer-in-Charge and where service/ repair is being carried out at site shall be under the expert supervision of authorised service agent.
(c) The make of DG sets are Kirloskar/ Ashok Leyland/ Greaves Cotton/Mahendra/ Cummins
(d) The contractor shall employ minimum 02 No manpower (01 -Electrcian , 01 Helper) at each area required for routine maintenance of DG sets.
(e) Filling of DHPP (N) in all mentioned DG Sets at various locations will be the responsibility of the contractor. However, DHPP (N) will be issued by MES. The amount for filling of DHPP (N) in DG sets is deemed to be inclusive in unit quoted rate.
(f) DHPP (N) required at the time of maintenance/ testing will be issued by MES.
(g) Representative of contractor shall maintain & update the maintenance/ breakdown register regularly and same will be checked by Engineer-in-Charge periodically.
(h) The monthly check shall be done once in a month but whenever breakdown occurs in DG set, the contractor has to attend all complaint unlimitedly through authorised service agent of the equipment/ machinery.
(j) The unit rate is deemed to be included for Cleaning of the surrounding area of DG set 5 mtr from plinth protection of E/M installations including removing of accumulated earth of any width and depth upto 15cm cleaning / Cutting the grass with hand operated petrol/ kerosene driven grass cutting machine and removing the grass waste to outside MD land.
(k) In case of minor defect, entire Job shall be completed within 06 hrs from the time of registration of complaint, failing which penalty charges @ Rs. 500/- per hours shall be recovered.
(l) In case of major defect, the period for attending of complaint shall be decided by the GE/EIC by accessing extent of repair required through joint inspection by Engineer-in-Charge and authorised service agent of the equipment at the site. If complaint is not rectified within the stipulated period and the GE is not satisfied with the reason for delay, then penalty at the rate of Rs. 600/- per hours shall be deducted from the dues of the contractor.
(m) Please note that above penalty is exclusively other than the condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt.
(n) The decision of the Accepting Officer in this regard shall be final and binding.
(o) The contractor should be responsible to maintain the DG set in serviceable condition for entire contract period.
Description all as per Sl Item No 257 here in before but for Capacity 40 KVA DG Set- Location:-Pump House -1 No
Description all as per Sl Item No 257 here in before but for capacity 125 KVA DG set Location:-Tech building :- 1 No
Dismantling/ taking down complete radiator assembly of 20 KVA to 40 KVA DG Set and transportation to authorised workshop for following repairs :- (a) Opening the radiator assembly with brazing/ welding for repair/ service. (b) Cleaning of all water tube with diluted solution of HCL and cleaning with water pressure and removing the sludge and dust from inside the tank by flushing out. (c) Determining the leak/ puncher in radiator tubes. (d) Repair of fins by soldering/ brazing. (e) Repair of bottom brass water tank by soldering/ brazing. (f) Repair of radiator hose assembly. (g) Fixing the complete radiator assembly to its original position and testing complete all as specified and directed by Engineer-in-Charge.
Dismantling/ taking down complete radiator assembly of 125 KVA DG Set and transportation to authorised workshop for following repairs :- (a) Opening the radiator assembly with brazing/ welding for repair/ service. (b) Cleaning of all water tube with diluted solution of HCL and cleaning with water pressure and removing the sludge and dust from inside the tank by flushing out. (c) Determining the leak/ puncher in radiator tubes. (d) Repair of fins by soldering/ brazing. (e) Repair of bottom brass water tank by soldering/ brazing. (f) Repair of radiator hose assembly. (g) Fixing the complete radiator assembly to its original position and testing complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable self motor of capacity 20 KVA to 40 KVA and carrying to authorised work shop for servicing including replacment of unserviceable spare parts Brush, holder, solonoid switch, armature bush, filed coil complete and refixing, testing complete all as specified and directed.
Taking down old unserviceable self motor of capacity 125 and carrying to authorised work shop for servicing including replacment of unserviceable spare parts Brush, holder, solonoid switch, armature bush, filed coil complete and refixing, Testing complete all as specified and directed.
Removing and replacing the old unserviceable one with new AVR (Automatic Voltage Regulator) suitable for Kirloskar curve of capacity 20 to 40 KVA having input voltage 2 phase + neutral sensing voltage 415 output voltage 95V DC, output current 4A DC voltage regulation +/- 1 % average volts, over excitation current tripping, fuse protection 4A, fast acting and frequency 50 Hz complete all as specified and directed.
Removing and replacing the old unserviceable AVR (Automatic Voltage Regulator) suitable for capacity 125 KVA having input voltage 2 phase + neutral sensing voltage 415 output voltage 95V DC, output current 4A DC voltage regulation +/- 1 % average volts, over excitation current tripping, fuse protection 4A, fast acting and frequency 50 Hz complete all as specified and directed.
Taking down 12/ 24 volts self starter assembly from DG set and transporting to its authorised workshop for repair/ servicing by replacement of defective spare parts such as carbon brush, carbon ring, bearing, bush, defectine wiring, winding and soldering after repair including testing after repair/ service and re-installation in original position for satisfactory function complete all as specified and directed.
Supply and fixing in replacement self starter 12 Volts of DG Sets complete all as specified and complete all as specified and directed.
Supply and fixing in replacement battery cable assembly (-ve & +ve) complete all as specified and complete all as specified and directed. Note :- Items like clamp, lugs, nut, bolts and copper cable of size 25 sqmm upto 1 mtr required for connection is deemed to be inclusive in unit rate quoted.
Supply and fixing in replacement maintenance free lead acid sealed battery (SMF) 12 volts 90 AH complete all as specified and as directed. Make : EXIDE. / Amaron/ Amar Raja/Cummins Note :- Old battery shall be deposited in MES store yard.
Supply and fixing in replacement maintenance free lead acid sealed battery (SMF) 12 volts 180 AH complete all as specified and as directed. Make : EXIDE. / Amaron/ Amar Raja/Cummins Note :- Old battery shall be deposited in MES store yard.
Material and labour Opening disconnecting LT Cable connections with care from Auto-Main Failure Panel and checking throughly with Fault Detector Instrument at Site and replacement of Minor Defective Parts as required at Site suitable for 20 KVA to 40 KVA DG Set complete all as specified and as directed.
Material and labour Opening disconnecting LT Cable connections with care from Auto-Main Failure Panel and checking throughly with Fault Detector Instrument at Site and replacement of Minor Defective Parts as required at Site suitable for 125 KVA DG Set complete all as specified and as directed.
Supply and fix in replacement of RPM meter assembly complete set including rubber gasket, wire as per sample complete all as specified and as directed.
Supply and fix in replacement of add-on auxilury contactor block 2No-2NC complete all as specified and as directed.
Supply and fixing in replacement of Relay for control contactor AC control std. Coil Voltage - 24, 110, 240, 415V, 50Hz MX0 22E (2 NO + 2 NC) complete all as specified and directed. Make L& T / BCH/ ABB
Supply and fixing in replacement indicator lamp RYB complete all as specified and as directed.
Supply and fix in replacement of push button for Start/Stop switch all as per sample complete all as specified and as directed.
Supply and fix in replacement of Relay for single phase preventor 6 wire suitable for all mode operation all as directed.
Supply and fix in replacement of electronic Oil pressure sensor complete with wiring, connectors, bottle thimble all as directed
Supply and fix in replacement of 12V/24V 11 pin PLA realy with base all as specified and as directed.
Supply and fix in replacement of radiator hose of any capacity complete all as specified and directed.
Supply and fix in replacement of oil drain hose set complete all as specified and as directed.
Supply and fix in replacement of fuel hose set nylon type of any capacity complete all as specified and directed.
Material and labour for replacement of door hinges of Acoustic enclosure heavy duty metal type for Left/Right sidecomplete all as specified and directed.
Supply and fix in replacement of water pump assembly of water cooling system of DG set any capacity complete all as specified and directed.
Material and labour for distilled water in 5 ltr/ 2 ltr sealed cane to be filled in batteries complete all as specified and directed.
Supply and fixing MCCB 63A, 16 KA, 4 Pole, 415V including taking down unserviceable one, complete all as specified and as directed. Make - L &T/Havells/Indoasian
Supply and fixing MCCB 200A, 36 KA, 4 Pole, 415V including taking down unserviceable one, complete all as specified and as directed. Make - L &T/Havells/Indoasian
Supply and fix in replacement of electronic water temp gauge sensor double pin in byepass complete with wiring, connectors, bottle thimble complete all as specified and directed.
Supply and fixing in replacement stop solenoid assembly 12V/ 24V DC for micro pump (two coil) heavy duty electrical control make energise to stop of DG Sets complete all as specified and directed. Make :- Kirloskar or existing brand of defective components or any reputed suitable make as approved by GE
Supply and fix in replacement of radiator fan belt suitable for any capacity DG setcomplete all as specified and as directed.
Disconnecting the existing battery of capacity 12V 90 to 180 AH from the DG set, taking it to battery workshop, draining out the complete unserviceable electrolyte acid from the battery, filling up with new Electrolyte acid to the required level, charging the battery, testing the battery for correct specific gravity, bringing back to the location, connecting to DG set, start the engine for satisfactory function all as directed by Engineer-in-charge.
Material and labour for battary electrolyte grade 1250 complete all as specified and directed.
Supply and fixing in replacement of brass terminal suitable for 12 Volts, 90/130/150/180 AH battery complete all as specified & directed.
Supply and fixing Battery charging alternator assembly 12 Volts of DG Sets complete including taking down existing one complete all as specified & directed.
Material and labour Repairs to 12V battery charging alternator assembly by removing, dismantling, replacing the unserviceable burnt rotor and stator assembly completly including insulation sleeves and refixing to the engine and testing to the satisfaction of DC volts & Amps by charging of battery complete all as specified & directed.
Supply and Fix in replacement of temeprature guage of any capacity complete all as specified and as directed. Make:- Kirloskar/Greaves or equivalent.
Material and labour for lubrication oil SAE 15 W - 40 grade API CI 4 plus type in sealed container for DG set Top up and change the oil in the sump after completely flushing the old oil from the tank/sump and cleaning of the same complete all as specified and as directed. (Make : Castrol/Valvoline/Servo)
Material and labour replacement of existing unserviceable door lock arrangement to DG set canopy with new door lock & key etc as per existing size & type complete all as specified & directed.
Supply and fix in replacement of oil seal assembly of any capacity as per sample complete all as specified and directed.
Supply and fix in replacement of electronic water temp gauge sensor single pin for engine block complete with wiring, connectors, bottle thimble complete all as specified and directed.
Supply and fixing in repairs door glass and beading for DG Set of any capacity complete all as specified and directed.
Supply and fixing in repairs 24V DC solenoid switch complete all as specified and directed.
Supply and fix in replacement of lubrication oil filter element with 'O' ring of Make MICO / Kirloskar / Mahle/ Cummins as required at site for 20 KVA capacities of DG Sets complete all as specified and as directed.
Supply and fix in replacement of lubrication oil filter element with 'O' ring of Make MICO / Kirloskar / Mahle/ Cummins as required at site for 40 KVA capacities of DG Sets complete all as specified and as directed.
Supply and fix in replacement of lubrication oil filter element with 'O' ring of Make MICO / Kirloskar / Mahle/ Cummins as required at site for 125 KVA capacities of DG Sets complete all as specified and as directed.
Supply and fixing in repairs earth Fault relay complete all as specified and directed.
Supply and fix in replacement of turbo cooler rubber hose of any capacity complete all as specified and as directed.
Supply and providing coolant concentrate in sealed container for top up complete all as specified. Make : Valvoline/ Fleet guard/ Mahle
Supply and fix in replacement of electronic Fuel Level sensor complete with wiring, connectors, bottle thimble complete all as specified and directed.
Supply and fix in replacement of radiator mounting pad set of any size complete all as specified and directed.
Supply and fixing in replacement contactor 4 pole,with 1 NO + 1 NC aux contacts and coil voltage 240 V/415 volt suitable for AMF Panels of 125 KVA DG Set complete all as specified and as directed. MAKE : L&T/BCH/Schneider
Supply and fixing in replacement contactor 4 pole,with 1 NO + 1 NC aux contacts and coil voltage 240 V/415 volt suitable for AMF Panels of 40 KVA DG Set complete all as specified and as directed. MAKE : L&T/BCH/Schneider
Supply and fixing in replacement contactor 4 pole,with 1 NO + 1 NC aux contacts and coil voltage 240 V/415 volt suitable for AMF Panels of 20 KVA DG Set complete all as specified and as directed. MAKE : L&T/BCH/Schneider
Supply and Replacement of fuel filter element with 'O' ring of Make MICO / Kirloskar / Mahle/ Ashok Leyland/ Cummins as required at site for 20 KVA capacities of DG Sets all as directed by Engineer-in-Charge.
Supply and Replacement of fuel filter element with 'O' ring of Make MICO / Kirloskar / Mahle/ Ashok Leyland/ Cummins as required at site for 40 KVA capacities of DG Sets all as directed by Engineer-in-Charge.
Supply and Replacement of fuel filter element with 'O' ring of Make MICO / Kirloskar / Mahle/ Ashok Leyland/ Cummins as required at site for 125 KVA capacities of DG Sets all as directed by Engineer-in-Charge.
Supply and fixing in replacement Cooling Fan suitable for DG Set 125 KVA capacity, complete all as specified and as directed.
Supply and fixing in replacement Cooling Fan suitable for DG Set 20 to 40 KVA capacity, complete all as specified and as directed.
Supply and fixing in repairs mechanical type diesel float switch assembly complete all as specified and directed.
Supply and fixing in replacement microprocessor based AMF controller unit for AMF Panel flush mounting typesuitable for DG Set 20 to 40 KVA capacity as per existing make complete all as specified and directed.
Supply and fixing in replacement microprocessor based AMF controller unit for AMF Panel flush mounting typesuitable for DG Set 125 KVA capacity as per existing make complete all as specified and directed.
Material and labour Surface excavation n.exc 30 cm deep and averaging 15 cm deep in hard /dense soil and getting out all as specified and as directed.
Supply and fix in replacement of flush type LED Digital multi functional meter with parameter (V,I,PF) suitable for DG set AMF panel complete of Model A class 1 complete all as specified & directed.
Disconnecting the electrical connection from AMF Panel, taking down DG set of cap 20 to 40 KVA for major overhauling of engine and transportation to authorised workshop for replacement of piston assembly complete-4 sets, exhaust valve, cyilinder liner, inlet and out let valves, sealing cap, copper washers,thermostat elements, spin of filter for lubrication oil, oil seal, valve tappet, gasket for cylinder head, bush for injector, gasket for exhuast manifold,joint for bearing housing, joint for delivery volute, turbo repair kit complete all as specified & directed.
Supply and fixing in repairs electronic type diesel float switch assembly complete all as specified and directed.
Supply and fix in replacment of valve door packing of any capacity complete all as specified and directed.
Supply and fix in replacement of Auto source transfer controller unit suitable for DG set AMF panel of any capacity and as per existing Make complete all as specified and directed.
Supply and fixing in repairs change over switch 125 amps capacity 4 pole 3 phase with enclosure complete all as specified and directed. Make-Legrand/ L&T / Indoasian
Supply & fix in replacement Cooling Fan (as per existing/ as approved by GE) suitable for DG Set 20 to 40 KVA capacity, complete all as specified and as directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in depth for laying of cables up to proper level complete all as specified and directed .
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engr-in-charge.
Removing surplus excavated material from excavation not exc 50 meter and depositing where directed at a level not exc 1.5 meter above the starting point complete all as specified and directed .
Material and labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983 and as directed. Note :- Excavated approved soil obtained from excavation under item No 1 shall be ribbed by using sieve to separate composite particles etc as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is than gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness will be considered for payment.
Material and labour for well burnt class ‘B’ bricks as mechanical protection to under ground cables laying with length of the bricks equal to the width of the trench complete all as specified and directed .
Supply and laying of GI pipe light grade for cable protection of size 80mm bore complete with fitting complete including taking down unserviceable one all as specified and directed .
Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, 800 mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and directed. Note :- The tenderer shall take into consideration for following points while quoting rate for this item and the unit rate is deemed to be inclusive for :- (i) Earth work and excavation in any type of soil (ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed. (iii) Removing excavated material to out side MD. (iv) Laying of any type/any bore of pipe in trenches including taking down. Supply of pipe shall be measured and paid separately (v) 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate as in road to make good existing disturbed surfaces.
Material and labour for Boring of holes under road, pavement hard standings by trenches technology using ultra sound technique and necessary machine including HDPE pipes of 100 mm dia suitable for 0.4 Mpa working pressure complete all as specified and directed.
Material and labour for 3 ½ core 185 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheather laying in trenches/cable ducts, fixed to wall/pole complete including taking down unserviceable one all as specified and directed. Make : Havells, Polycab, RPG Asian
Supply and fix in replacement of Air filter element inner and outer as required at site with 'O' ring of Make MICO / Kirloskar / Mahle/ Cummins as required at site for 20 KVA capacities of DG Sets complete all as specified & directed.
Supply and fix in replacement of Air filter element inner and outer as required at site with 'O' ring of Make MICO / Kirloskar / Mahle/ Cummins as required at site for 40 KVA capacities of DG Sets complete all as specified & directed.
Supply and fix in replacement of Air filter element inner and outer as required at site with 'O' ring of Make MICO / Kirloskar / Mahle/ Cummins as required at site for 125 KVA capacities of DG Sets complete all as specified & directed.
Supply and fixing in repairs change over switch 63 amps capacity 4 pole 3 phase with enclosure complete all as specified and directed. Make-Legrand/ L&T / Indoasian
Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compilaints & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure shall be above 200mm for air circulation & to minimize temp rise. Panel shall be fitted with one No polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 300 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following swtich gears and mounting the panel board on ground with PCC (1:3:6) bedding upto a height of 45 CM above ground level, including dismanting and taking out old U/s LT panel board of any size and description, reconnecting existing LT UG Cable with new panel board, complete all as specified and as directed :-
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 160 Amp, 25 KA - 01 No (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amp, 10 KA - 05 No. (c) MCB TPN, 415 V of capacity 40 Amps, 10 KA - 01 No. (d) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set (f) Space for spare feeder - 01 No. Note :- (i) The Contractor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as per mentioned in list of makes (PS).
Supply and fixing in replacement of Fly wheel ring including nuts and bolt suitable for DG Set 20 to 40 KVA capacity as per existing make complete all as specified and directed.
Supply and fixing in replacement of Fly wheel ring including nuts and bolt suitable for DG Set125 KVA capacity as per existing make complete all as specified and directed.
Supply and fixing in replacement of wiring of AMF panel of capacity DG set including copper wire ,PVC wire holder and other connected items suitable for DG Set 20 to 40 KVA capacity as per existing make complete all as specified and directed.
Material and labour for 3 ½ core 95 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheather laying in trenches/cable ducts, fixed to wall/pole complete including taking down unserviceable one all as specified and directed. Make : Havells, Polycab, RPG Asian
Material and labour for 3 ½ core 70 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheather laying in trenches/cable ducts, fixed to wall/pole complete including taking down unserviceable one all as specified and directed. Make : Havells/Polycab/ RPG Asian
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising of 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing one, complete all as specified and directed.. Make : Model HTSP 317 of safeTrode or equivalent in OBO Betterman/ FURSE/ERICO.
The quoted rate shall also deemed to be included the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 04 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work.
(v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.
(vi) Copper strip of size 20 x 3 mm shall be fixed on proper post insulator at the instrument end ( copper strip upto 7.5 RM shall be considered in unit quoted rate and extra will be measured and paid separately).
(vii) Testing of earth shall be carried out in presence of departmental and user representative and report shall be submitted to Garrison Engineer duly signed by all concerned.
(viii) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(ix) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
(x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.
(xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.
(xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained.
(xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contractor from final bill for the guarantee period.
(xiv) The electrode shall carry manufacturer's name .
(xv) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.
(xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.
(xvii) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.
(xviii) The contractor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material.
(xix) Sign board of mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by engr -in- charge.
Material and labour for Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 7.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm dia for each electrode pit complete including taking down all as specified and directed. Make : Model SEPC 250 of SAFE TRODE/ Electrogrip Model/ EGTEK3LC of ISG Global or equivalent in OBO Betterman/ ERICO. Note :- The contractor shall submit load bearing capacity certificate from the manufacturer.
S&F in repair copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing one, complete all as specified and directed. Note : - All Joints should be joined by Exothermic Welding or Brazing.
Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compart mentalized in construction with opaque and transparent doors, properly tightened to base with thromoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No polycarbonate IP 65, 9 W LED translucent bulk head luminaire color temp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with one no of 16 Amp 3 Pole IP65 industrial socket and 01 No of 32Amp 5P IP 65 industrial socket. 3 Phase and neutral 300 Amp current carrying capacity of Aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following swtich gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded aggregate bedding upto a height of 45 CM above ground level, including dismanting and taking out old U/s LT panel board of any cap and description and reconnnecting existing LT UG Cable with new panel board all as directed :-
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 160 Amp, 36 KA - 01 No (Incomer). (b) On Load Change over front operated of capacity 200 Amp, 4 Pole, 415 V - 01 No. (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 125 Amp, 25 KA - 02 Nos. (d) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amp, 10 KA - 03 Nos. (e) MCB TPN, 415 V of capacity 40 Amps, 10 KA - 01 No. (f) MCB SPN, 240 V of capacity 40 Amps, 10 KA - 03 Nos. (g) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (h) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (j) Space for spare feeder - 01 No. Note :- (i) The Contractor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as per mentioned in list of makes (PS). Note :- An amount of Rs 102093.00 on account of credit schedule for schedule 'A' part II shall be deducted from the total amount of BOQ to arrive at the contract sum.
ANAND REFRIGERATION (BID ID -3189638)
UNIVERSAL ENGINEERING (BID ID -3190110)
JM Engineering (BID ID -3190053)
PLATINUM CONSTRUCTIONS (BID ID -3190136)
devan enterprises (BID ID -3190294)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .