Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.4 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹17.1 L+₹13,650.70 (0.80%)Rejected-Finance | L2 | Rejected-Finance High Rate Quoted | |
| 3 | L3₹18.2 L+₹1.3 L (7.57%)Rejected-Finance B 22 152 STREET NO 1 14 BABA FARID NAGAR BATHINDA 151001 PB | BATHINDA | PUNJAB | 151001 | L3 | Rejected-Finance High Rate Quoted | |
| 4 | L4₹19.0 L+₹2.1 L (12.3%)Rejected-Finance OPPOSITE RADIO STATION TOWER TILAK NAGAR SAGAR ROAD BIKANER 334001 RAJASTHAN | BIKANER | RAJASTHAN | 334001 | L4 | Rejected-Finance High Rate Quoted | |
| 5 | L5₹19.3 L+₹2.3 L (13.5%)Rejected-Finance H NO 327 KRISHNA ENCLAVE HIMMATGARH PO DHAKOLI ZIRAKPUR 140603 | S A S NAGAR | PUNJAB | 140603 | L5 | Rejected-Finance High Rate Quoted |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
11 Aug 2023, 6:00 pmClosed
Col Shery Goel, CWE Bikaner
HQ CWE Bikaner
Repair/Replacement of SGSW Pipe of existing sewage lines including septic tank, manhole and soakage well at Kanasar Mil Stn
2023_MES_609133_1
CA No CWE BKN-Token No. 20/2023-2024
Open Tender
Miscellaneous Works
Item Rate
180 days
AGE (I) Kanasar
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
AGE (I) Kanasar
₹50,000
Yes
28 Aug 2023
14 Jul 2023
18 Aug 2023
14 Jul 2023
11 Aug 2023
28 Jul 2023
14 Jul 2023 - 22 Jul 2023
Amount
Demolition of cement concrete (unreinforced) in ground floor and pavings not exc 15 cm thick (below or above ground level) including floor tiles of any description complete all as specified & as directed.
Demolition of cement concrete (reinforced) in ground floor and pavings not exc 15 cm thick (below or above ground level) including floor tiles of any description complete all as specified & as directed.
Demolition of unreinforced cement concrete of any description and in any position (not otherwise specifically provided for in this Schedule, complete all as specified & as directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
Taking down cement plaster or cement lime plaster, terrazo etc on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc, complete all as specified and as directed.
Dismantling of stone slabs and tiles of any description or any thickness in floors, dado etc, laid bedded and pointed in any mortar, complete all as specified & as directed.
Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and as directed.
Removing excavated soil/material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and as directed.
M&L for PCC 1:3:6 type C2 using 40 mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for cement concrete (1:3:6) type C1 using 20 mm graded crushed stone aggregate as in surface channels and drains and benching including finishing the top of benching even and smooth using extra cement complete all as specified and as directed.
M&L for cement concrete 1:2:4 type B1, using 20mm graded crushed stone aggregate as in copings, kneelers, apex stones, bed plates and the like including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished fair complete all as specified & as directed.
M&L for precast RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for man holes, drains etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including placing in position and set in CM (1:4) including necessary form work complete all as specified & as directed. Note :- Reinforcement shall be measured and paid for separately under respective item of this Schedule.
M&L for brick work with old size burnt clay sub-class ‘B’ bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:4 complete all as specified and as directed. Note : Brick work under this item shall be carried out in sewage disposal work (i.e. manholes) and area drainage work (i.e. drains).
M&L for Jodhpur stone roof slabs, self faced 7.5cm to 10cm thick, 25cm to 35cm wide, hoisted and set, jointed and grouted in cement mortar 1:3 complete all as specified & as directed.
M&L for 50mm thick PCC (1:3:6) type C1 using 20mm graded crushed stone aggregate as in flooring, leveling course, etc, over stone patti/RCC roof slab, surface finished even and smooth without using extra cement, complete all as specified and as directed.
M&L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & as directed.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified.
M&L for rendering 15mm thick in cement mortar 1:4 on brick masonry or concrete surfaces other than fair faces of brick work and finished even & smooth without using extra cement, complete all as specified and directed.
S&F as in repairs 110mm bore PVC (SWR) soil, wasted and vent pipes single socketed in any length with rubber ring joints / solvent cement joints fixed to walls complete all as specified & as directed.
S&F as in repair 110mm bore PVC (SWR) vent cowl complete all as specified & as directed.
M&L for 150mm bore reinforced concrete pipes, class NP-2, laid on PCC bed and jointed complete with collars (concrete bed shall be measured and paid for separately) including demolition and breaking up 150mm bore SGSW/RCC/AC drain pipes set in cement mortar including PCC haunching and bedding, complete all as specified and as directed.
S&F salt glazed stone ware drain pipes of 150mm bore, Class ‘SP 2’, ISI marked, laid to slope in trenches, jointed in CM (1:1) and tested including demolition and breaking up 150mm bore SGSW/RCC/AC drain pipes set in cement mortar including PCC haunching and bedding, complete all as specified and as directed.
M&L for PCC 1:3:6 type C2 using 40mm graded crushed stone aggregate in bedding to drain pipes, including packing under and haunching against the sides of pipes after they are laid and tested for 150mm bore pipe complete all as specified and as directed.
M&L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends etc complete all as specified and as directed.
M&L for preparation of newly plastered / unplastered surfaces of walls & applying three coats of white wash complete all as specified and directed.
SIYA ENTERPRISES
HARPREET SINGH CONTRACTOR
M S GROUP
G S BUILDERS AND ENGINEERS
SHREE JASWANT CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .