Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.4 LAccepted-AOC 0 AJAY KUMAR 85 HASTAM HASTAM BANDA UTTAR PRADESH 210001 HASTAM BANDA UTTAR PRADESH 210001 UDYAM UP 13 0007628 | BANDA | UTTAR PRADESH | 210001 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹41.0 L+₹2.2 L (5.73%)Rejected-AOC 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹46.8 L+₹8.0 L (20.5%)Rejected-AOC 31 SARASWATI SONI MARG DEHRADUN | DEHRADUN | L3 | Rejected-AOC NOT LOWEST |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
15 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE HILLS DEHRADUN
HQ Commander Works Engineers Hills Mall Road Dehradun Cantt Dehradun 248003 Tele 01352757790
REPAIR REPLACEMENT OF CERTAIN ELECTRIC WIRING FITTINGS AND FIXTURES IN MD ACCN AT RAIWALA MIL STATION
2021_MES_478427_2
86325/RWL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE I Raiwala
Class D Cat b i
7 documents required · 7 mandatory
₹500
AGE I Raiwala
₹90,000
3 Jan 2022
27 Nov 2021
17 Dec 2021
27 Nov 2021
15 Dec 2021
3 Dec 2021
27 Nov 2021 - 30 Nov 2021
90 days
Amount
Dismantling and taking down U/S point wiring of any type (light, fan, socket, power) complete fitting such as switches, ceiling roses, pendants, lamp holder, light fitting etc including CI/Pressed steel terminals, switch box, and making good the disturbed surface of wall/floor etc, to match with the existing surfaces of wall/floor complete all as specified and directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
Taking down carefully by unscrewing from ceiling roses, Light fittings, switch , sockets, regulators for reuse at site and carrying to the store to re-fix the serviceable materials required screws, nuts, washers of chromium plated are use in without any extra cost complete all as specified & directed.(To be measured only when found serviceable in all respect for reuse. )
Dismantling and taking down u/s sub-main wiring/service wire of any size including wooden batten / PVC Conduit etc and making good the disturbed surfaces of wall/ceiling to match with the existing wall/ceiling etc complete all as specified & as directed. Note :- If the contractor fail to make good the disturbed surface of wall/ceiling etc and do not match with the existing surface of wall/ceiling to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
Dismantling and taking down old damaged existing DB’s of any type and making good the disturbed surfaces of wall/ceiling to match with the existing wall/ceiling etc. complete all as specified and directed.
Taking down old unserviceable wooden meter box of any size & any type from wall by disconnecting all electrical connections complete all as specified & directed.
Taking down energy meter from wooden/steel meter box carefully and deposit to MES store yard complete all as specified & directed.
Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with continious earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including concealed PVC conduit,medium grade(ISI marked) ,duly concealed on wall/ceiling or above false ceiling with fittings not less than 20 mm dia medium grade (Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover plate complete all as specified and directed. Note:- (i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates. ii) If the contractor fail to make good the disturbed surface of wall/ceiling etc and do not match with the existing surface of wall/ceiling to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
One 3 pin/5 pin 5/6 Amps socket outlet on same board with other switches, with cables 1.5 Sqmm size, complete all as specified and directed.
All as per item no 7.01 but for One 3pin/5pin 5/6 Amps socket out let on independent board with other switches, with cables 1.5 sq mm size, complete all as specified and directed.
All as per item no-7.01 above but controlled by two, two way switch 5/6 Amps. With cables 1.5 sq mm size complete all as specified & directed.
All as per item No 7.01 above but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point complete all as specified & directed.
Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with continious earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including surface rigid PVC conduit medium grade (ISI marked) on wall/ceiling or above false ceiling with fittings not less than 20 mm dia (Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover plate complete all as specified and directed.
One 3pin/5pin 5/6 Amps socket out let on same board with other switches , with cables 1.5 sq mm size , complete all as specified and directed.
All as per item no-8 above but One 3pin/5pin 5/6 Amps socket out let on independent board with other switches, with cables 1.5 sq mm size, complete all as specified and directed .
All as per item no-8.00 above but controlled by two, two way switch 5/6 Amps. With cables 1.5 sq mm size complete all as specified and directed.
All as per item No 8 above but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point complete all as specified and directed.
All as per item No-08 above but for existing concealed conduit inside wall, ceiling etc (light, fan, call bell) complete all as specified and directed.
All as per Item No 8.01 above but for existing concealed conduit inside wall, ceiling etc (5 amps socket on same board) complete all as specified and directed.
All as per Item No 8.02 above but for existing concealed conduit inside wall, ceiling etc (5 Amps socket on Independent board) complete all as specified and directed.
All as per Item No 8.03 above but for existing concealed conduit inside wall, ceiling etc (Two way point wiring) complete all as specified and directed.
All as per Item No 8.04 above but for existing concealed conduit inside wall, ceiling etc (power point) complete all as specified and directed.
All as per item No-08 above but for PVC Casing caping (light, fan, call bell) complete all as specified and directed.
All as per Item No 8.01 above but for PVC Casing caping (5 amps socket on same board) complete all as specified and directed.
All as per Item No 8.02 above but for but for PVC Casing caping(5 amps socket on Independent board) complete all as specified and directed.
All as per Item No 8.03 above but for but for PVC Casing caping (two way point) complete all as specified and directed.
All as per Item No 8.04 above but for but for PVC Casing caping (power point) complete all as specified and directed.
S & F switch Modular single pole, one way 6 Amps , 1 module, 230 volts, 50 hz complete all as specified and directed.Make: Legrand cat No: 6734 01/ Indoasian Cat No: 800000 or equivalent make of L&T/Havells
Supply and fixing switch modular , one-way 16Amps, 1 module 240 Volts AC complete all as specified and directed. Make: Legrand cat No: 673411/ Indoasian Cat No: 800002 or equivalent make of L&T/Havells
Supply and fix Modular Socket outlet, 6A - 2/3 pin combined, 2 module ISI marked, 230 volts, 50 hz complete all as specified and directed.Make: Legrand cat No: 6734 52 / Indoasian cat no: 800020 or equivalent make of L&T/Havells
Supply and fixing modular socket, 6A/16A -2/3 pin combined 2 module 230 volts, 50 hz complete all as specified and directed.Make: Legrand cat No: 6734 55 / Indoasian cat no: 800022 or equivalent make of L&T/Havells
Supply and fixing switch modular flush type single pole, two way 6 Amp, 1 module ISI marked, 230 volts, 50 hz all complete all as specified and directed.Make: Legrand cat No: 6734 02 / Indoasian cat no: 800001 or equivalent make of L&T/Havells
Supply and fixing bell push modular flush type single pole one way 6 Amps, 1 module with indicator, ISI marked complete all as specified & directed.
Supply and fixing step socket type modular fan regulator 120/280 V 2 module with indicator, ISI marked complete all as specified and directed.
Supply and fixing bell ding dong AC 230/240 volts single pole, complete all as specified & directed.
Supply and fixing ceiling rose surface bakelite 65/25 mm dia having three terminals complete all as specified & directed.
Supply and fixing in repair Fancy angle holder Metal ring insulated body with back plate, suitable for batten fittings complete all as specified & directed.
Supply only and in repairs /replacement switch piano 230 volts, AC, flush type single pole, one way 5/6 Amps ISI marked complete all as specified and directed. Cat part no HSN8536/14111 OF Anchor, HSN 8536/7021 0f Cona or equivalent in Havells
Supply only in repair/replacement switch piano 230 volts,AC, flush type white /ivory finish 15/16 Amps single pole one way complete all as specified and directed.Make:-Cat part no HSN8536/33118 OF Anchor, HSN 8536/7081 0f Cona or equivalent in Havells.
Supply only in repairs/replacement, socket out let 3/5 pin 5/6 Amps flush type complete all as specified and directed. Make:- Cat part no HSN8536/14302 OF Anchor, HSN 8536/7021 0f cona or equivalent in Havells .
Supply and fixing in repair socket outlet 5/6 pin 5/15 amp flush type mulit suitable for 240 volts AC ISI marked complete all as specified and directed.
Supply and fixing in repair batton/angle holder insulated body with back plate, suitable for batten fittings complete all as specified & directed.
Supply and fixing in repair bell ding dong AC 230 volts single pole complete all as specified & directed.
Suupply and fixing in repair step socket type fan regulator 120/280 V , ISI marked complete all as specified and directed.
Supply and fix surface mounted LED luminiare, 20 watt 4 feet with all accessories having polymer extruded channel with diffuser for glare free light, high lumen output, driver PF >0.98 having over voltage protection upto 400 volts surge protection, level 7-10 KV thermal short circuit protection THD<10%, made up of long life LED chips (SMD) in modular with Ra>70 and lumen efficiency >120 lumen per watt, internally pre-wired through flexible wire connecting with ceiling rose complete all as specified & directed. Make:- Model: SZSLBMX020 of Shakti or equivalent make of crompton. Note: The firm has to give warranty for fitting including driver minimum for 2 years for any defects developed during the period.
Supply and fix new LED building security light 1 x 20 W housing made out of pressure die-cast aluminium alloy with toughned glass, IP 66 protection working on 240 volts, 50 Hz, consisting of reflecting lamps wired with appropriate driver PF> 0.98 having overvoltage protection upto 440 volt, surge protection level > 10 KV, thermal short circuit protection THD< 10% made up of long life LED chip (SMD) in modular with Ra< 70, and LED lumen efficiency > 140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminaire efficiency> 120 luminous /watt power LED should be of more than 01 watt CCT should be between 5700° K- 6500 K including fixing on existing bracket including making necessary electric connection with 1.5 sqmm , 3 core, PVC insulated copper conductor cable 1100 Volt grade complete all as specified and as directed. Note:- (i) The firm has to given warranty of street light fittings including driver minimum for 02 years for any defect developed during the period. (ii) The contractor Shall submit the third Party LM 79 report from any NABL approved laboratory (iii) The fiitting should have BIS , CRS No
Supply and fixing sheet metal enclosure double door type for MCBs DB SPN (Single pole and neutral) 240V AC 8 way with 200 Amps rated bus bar complete all as specified and directed .Make- legrand / ABB/ Schnider/L&T/Siemens
Supply and fixing sheet metal enclosure double door type for MCBs DB SPN (Single pole and neutral) 240V AC 4 way with 200 Amps rated bus bar complete all as specified and directed .Make- legrand / ABB /Schnider/L&T/Siemens
Supply and fixing sheet metal enclosure double door type for MCBs DB TPN 63 amps 415V AC 4 way with 200 Amps rated bus bar complete all as specified and directed .Make- legrand / ABB/ Schnider/L&T/Siemens
Supply and fixing sheet metal enclosure double door type for MCCB DB VTPN 4 way with MCCB 4 pole, adjustable thermal & fixed magnetic type 40-63 Amp, 16 KA, 4 pole MCCB of Make Legrand, ABB, Schnedier complete all as specified and directed. Note:- Set the MCCB as per builidng load and distribute the load before charge the load.
Supply and fixing sheet metal enclosure double door type for MCBs DB SPN(Single pole and neutral) 240V AC 12 way with 200 Amps rated bus bar complete all as specified and directed .Make- legrand / ABB /Schnider/L&T/Siemens
Supply and fixing MCB SPN 10- 32 Amp 'B' series, 10 KA repturing capacity all as specified and directed. Make -Legrand/ABB/Schneider/ L&T/ Siemens
Supply and fixing MCB SP 6 to 32 Amp 'B' series 10 KA rupturing capacity complete all as specified & directed. Make:- Legrand , ABB/ Schnider/L&T/Siemens
Supply and fixing MCB SP 2-5 Amp 'B' series 10 KA rupturing capacity complete all as specified & directed. Make:- Legrand , ABB/ Schnider/L&T/Siemens
Supply and fixing single pole and neutral enclosure with a two pole and earth plug socket complete with 01 No, RCCB 15 Amp, DP, 240 Volts, AC Complete all as specified & directed. Make - Legrand, ABB, Schnider./L&T/Siemens
Supply and fixing single pole and neutral enclosure modular type with a two pole and earth plug socket complete with one, single pole MCB 20 Amps 10 KA rupturing capacity 240 Volts AC complete all as specified & directed. Make -Legrand, ABB/ Schnider/L&T/Siemens
Supply and fixing sub main wiring two single core 4 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade surface/concealed in wall along with 4.00 Sq mm PVC insulated unsheathed copper conductor cable (FR LSH) as earth wire and wire connected with main earth dolly including cutting chases and making good disturbed portion complete all as specified and directed . Note: Two runs of phase, netural wire and one run of earth wire and PVC conduit will be measured as one RM or one length.
Supply and fixing sub main wiring two single core 4 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in existing conduit or more medium grade surface/ concealed in wall along with 4.00 Sq mm PVC insulated unsheathed copper conductor cable (FRLSH ) as earth wire and wire connected with main earth dolly including cutting chasing and making good disturbed portion complete all as specified and directed .Note: Two runs of phase, netural wire and one run of earth wire will be measured as one RM or one length.
Supply and fixing sub main wiring for four single core 4 Sqmm PVC insulated unsheathed stranded copper conductor cable (FRLSH) 1100 volts graded drawn in for three phase and one for netural & including rigid PVC conduit 20 mm dia or more medium grade concealed in wall as per existing along with 4. Sqmm PVC insulated unsheathed copper conductor cable (FRLSH) as earth wire connected with main earth dolly including cutting chasing and making good disturbed portion complete all as specified and directed. Note: Four runs of phase, netural wire and one run of earth wire and PVC conduit will be measured as one RM or one length.
S&F temper proof electronic meters in repair, testing commisioning and sealing of temper proof LCD display with polycarbonate cover 230/240 Volt, capaciaty 10-60Amps (Single phase) acccuracy class-I, 50 Hz, confirming to IS 13779, IP-54 with parameter to show data, time current reading , load, PF , voltage and KWH complete including electric connection incoming and outgoing with PVC insulated unsheathed multi stranded copper conductor FRLSH cable single core 1100 Volt grade of size 4 sqmm with proper tinned copper lugs and Flexible PVC conduit medium grade 20 mm dia surface/ concealed where required complete all as specified and directed. Make L&T, Siemens, Schneider.
Supply and fixing temper proof electronic meters in repair, testing commissioning and sealing of temper proof LCD display with polycarbonate cover 415 Volt, capaciaty 10-60Amps (Three phase) acccuracy class-I, 50 Hz, confirming to IS 13779, IP-54 with parameter to show data, time current reading , load, PF , voltage and KWH complete including electric connection incoming and outgoing with PVC insulated unsheathed multi stranded copper conductor FRLSH cable single core 1100 Volt grade of size 6 sqmm with proper tinned copper lugs and Flexible PVC conduit medium grade 20 mm dia surface concealed where required complete all as specified and directed. Make L&T, Siemens, Schneider.
Supply, installing, testing and commissioning factory made and tested LT Panel indoor type wall mounted, size not less than 900x900x250mm suitable for 415 Volts 3 Phase and neutral, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated electrolyted Aluminium bus bars TPN of capacity 200 Amps rating insulated, bus bar mounted on DMC insulators with bus bar chamber, front opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLSH cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens gray RAL-7035 shade. The scope of work also comprising of the following and size of panel suitable to fixing all below materials with required space as per IE rules:- (a) BUS BAR CHAMBER :- i) 200 Amps 3 Strips and Neutral Strip 100 Amps, Aluminium Conductor with color coded heat shrinkable sleeve and shall be mounted on non hygroscopic , non combustible, track resistant high strength DMC material interconnection of all incomings & outgoings. ii) Red, Yellow Blue Phase indicating lights LED Type 220 V AC-1 Set (Set of Three)
INCOMING SUPPLY:- i) MCCB 63 Amps 25 KA, 4 Pole with Adjustable thermal & Fixed magnetic setting release 415 Volts, 50Hz- 01 No. Make of MCCB -L&T/Siemens/Legrand/Schneider. OUTGOING SUPPLY:- i) MCB TPN 6-32 Amps 415 Volts, 50Hz, rupturing capacity 10 KA = 4 Nos, Make of MCB-L&T/Siemen /Legrand/Schneider. (ii) MCB SPN 10 Amps 230 volts, 50 Hz, rupturing capaicty 10KA=1 No. Make of MCB-L&T/Siemen /Legrend/Schneider. iii) Space required for 04 Nos Electric Energy meter Three Phase AC 415 V, 10-60 Amps & 01 No single phase electric meater 5-10 amps single phase 240 volts. iv) DMC Connector 2 way 100 A for outgoing submain supply-5 Nos Panel wiring for control circuit with copper flexible 1.5 Sqmm & power wiring minimum 4 Sqmm flexible . Notes:- 1. The panel manufacturer should have following certification:- i) CPRI certificate Degree of protection IP-54 (should have IEC:61439-1-2 & IEC: 60529 tests) ii) CPRI certificate short circuit with stand strength should be 50 KA RMS for 1 Sec with initial peak of 105 KA.( iii) CPRI certificate rated current not less than 5000A. 2. MCCB should be capable for on line setting of the current. 3. Drawing of panel board/meter box should be got approved from AGE (I) Raiwala before fabrication and contractor visit the site beore designing the panel. 4. Panel board should be fully compartmentalized in accordance to form 4b of IEC 61439-1-2. 5.There should be provision of seprate compartment for each energy meter with all necessary wiring as per approved drawing. 6. Three phase/single phase energy meter will be measured and paid seprately in relevant schedule items.
Supply, installing, testing and commissioning factory made and tested LT Panel indoor type wall mounted, of size not less than 900x900x250mm suitable for 415 Volts 3 Phase and neutral, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated electrolyted Aluminium bus bars TPN of capacity 200 Amps rating insulated, bus bar mounted on DMC insulators with bus bar chamber, front opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens gray RAL-7035 shade. The scope of work also comprising of the following and size of panel suitable to fixing all below materials with required space as per IE rules:- (a) BUS BAR CHAMBER :- i) 200 Amps 3 Strips and Neutral Strip 100 Amps, Aluminium Conductor with color coded heat shrinkable sleeve and shall be mounted on non hygroscopic , non combustible, track resistant high strength DMC material interconnection of all incomings & outgoings. ii) Red, Yellow Blue Phase indicating lights LED Type 220 V AC-1 Set (Set of Three) INCOMING SUPPLY:- i) MCCB 40 Amps 16 KA, 4 Pole with Adjustable thermal & Fixed magnetic setting release 415 Volts, 50Hz- 01 No. Make of MCCB -L&T/Siemens/Legrand/Schneider.
OUTGOING SUPPLY:- i) MCB TPN 6-32 Amps 415 Volts, 50Hz, rupturing capacity 10 KA = 2Nos, Make of MCB-L&T/Siemen /Legrend/Schneider. (ii) MCB SPN 10 Amps 230 volts, 50 Hz, rupturing capaicty 10KA=1 No. Make of MCB-L&T/Siemen /Legrend/Schneider. iii) Space required for 02 Nos Electric Energy meter Three Phase AC 415 V, 10-60 Amps & single phase, AC 240V, 10-60 Amps & 01 No of single phase AC 240 volts electric meter 5-10 amps. iv) DMC Connector 2 way 100 A for outgoing submain supply-5 Nos Panel wiring for control circuit with copper flexible 1.5 Sqmm & power wiring minimum 4 Sqmm flexible . Notes:- 1. The panel manufacturer should have following certification:- i) CPRI certificate Degree of protection IP-54 (should have IEC:61439-1-2 & IEC: 60529 tests) ii) CPRI certificate short circuit with stand strength should be 50 KA RMS for 1 Sec with initial peak of 105 KA. iii) CPRI certificate rated current not less than 5000A. 2. MCCB should be capable for on line setting of the current. 3. Drawing of panel board/meter box should be got approved from AGE (I) Raiwala before fabrication and contractor visit the site beore desing the panel. 4. Panel board should be fully compartmentalized in accordance to form 4b of IEC 61439-1-2. 5.There should be provision of seprate compartment for each energy meter with all necessary wiring as per approved drawing. 6. Three phase/single phase energy meter will be measured and paid seprately in relevant schedule items.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 4 mm GI wire as earth lead by means of brass nuts and bolt, thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size PCC 1:2:4 Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing wire to panel, including testing on completion complete all as specified and directed. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighing not less than 4kg/sqm in lieu of CI cover. (ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items.
Material and labour for repair and replacement of existing rusted metal circuit box including hylam sheet and switch, sockets, regulators with new 1/ 2 way-6way modular type metal box with and incl decorative polycarbonate frame for housing modular switches, sockets, fan regulatrs etc including white cover plate complete and connect existing circuit wiring with new switches & testing complete all as specified and directed. Note:- 1 payment will be done for each module as per rates quoted by the contractor 2.switch /sockets /regulators will be paid seperately.
Fixing only serviceble light fitting retrived from Item No-02 above complete all as specified and directed.
Fixing only serviceable switches retrived from Item No-02 above complete all as specified and directed.
Fixing only serviceable sockets retrived from Item No-02 above complete all as specified and directed.
Fixing only serviceable regulators retrived from Item No-02 above Note:- Inventry for fitting to be prepared in a standard format by joint Inspection of site by Engineer -in-Charge and contractor and same will be signed by both parties
Supply only 4mm dia GI wire complete all as specified and directed.
M/s badrinath Traders
M/s RP AGRAWAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .