| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.7 CrQualified C 185 PHASE 1 NARAINA INDUSTRIAL AREA NEW DELHI 110028 | NEW DELHI | DELHI | 110028 | ₹42.7 Cr | L1 | Qualified MII |
Tender Value
₹35.9 Cr
EMD Value
₹60.9 L
Closing Date
22 Feb 2023, 3:00 pmClosed
DSITC of solar power plants with cumulative capacity of 4
4243684
GEM/2023/B/2961850
Two Packet Bid
BOQ Item No - 1,BOQ Item No - 2,BOQ Item No - 3,BOQ Item No - 4,BOQ Item No - 5,BOQ Item No - 6,BOQ
Erode, Tamil Nadu
Total value wise evaluation
BOQ
10 documents required · 10 mandatory
3 yrs
₹9.6 Cr
₹9.6 Cr
80%
₹60.9 L
21 Mar 2023
9 Jan 2023
22 Feb 2023
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | BOQ Item No - 1 | Design, Supply, Installation, Testing and Commissioning (DSITC) of Grid Connected ground mounted DC Solar PV-module-based power supply system of capacity below mentioned with modules fixed in anodized aluminium frame complete as required including elevated structural support systems for all components after proper soil investigation / treatment as per site conditions, modular inverters with atleast 25 percent standby / spare capacity with required communication / data / control / power cables, safety system for reverse power protection, min IP65 rated DC DB / JB for connection of modules to inverters . . . . . . solar power plant complete as required and as per technical specifications and other terms and conditions of the contract. It also includes provision of skilled / unskilled manpower as per the requirement (as and when required) for proper operation and routine maintenance of the said solar power plant during defects liability period (DLP) of 02 years as per specifications, terms and conditions of the tender document.
It also includes O and AICMC of above said solar power plant for 08 years after expiry of DLP of 02 years as per tender specifications, terms and conditions etc. completed as required.
Note -
The quoted rates are inclusive of 08 years of Operation and AICMC cost (after DLP period of 02 years). The share of O and AICMC and DSITC components are fixed. The O and AICMC component shall be 10 percent of quoted amount and DSITC component shall be 90 percent of the quoted amount.
Distribution of 10 percent . . . . . .
Location - Udaipur Airport
Capacity - 500 KW (AC)
Approx. distance of Evacuation point from solar installation - 2.5 Km
Evacuation point voltage level - 33 KV (as per system design and site requirement)
Note - for details refer tender document Schedule of Quanties Page SOQ 1 | 1 | Job | emcudaipur | 300 |
| 2 | BOQ Item No - 2 | Design Supply, Installation, Testing and Commissioning (DSITC) of Grid Connected ground mounted DC Solar PV-module-based power supply system of capacity below mentioned with modules fixed in anodized aluminium frame complete as required including elevated structural support systems for all components after proper soil investigation / treatment as per site conditions, modular inverters with atleast 25 percent standby / spare capacity with required communication / data / control / power cables, safety system for reverse power protection, min IP65 rated DC DB / JB for connection of modules to inverters . . . . . . solar power plant complete as required and as per technical specifications and other terms and conditions of the contract. It also includes provision of skilled / unskilled manpower as per the requirement (as and when required) for proper operation and routine maintenance of the said solar power plant during defects liability period (DLP) of 02 years as per specifications, terms and conditions of the tender document.
It also includes O and AICMC of above said solar power plant for 08 years after expiry of DLP of 02 years as per tender specifications, terms and conditions etc. completed as required.
Note
The quoted rates are inclusive of 08 years of Operation and AICMC cost (after DLP period of 02 years). The share of O and AICMC and DSITC components are fixed. The O and AICMC component shall be 10 percent of quoted amount and DSITC component shall be 90 percent of the quoted amount.
Distribution of 10 percent . . . . .
Location - Jabalpur Airport
Capacity - 500 KW (AC)
Approx. distance of Evacuation point from solar installation - 0.5 Km
Evacuation point voltage level - HT / LT (as per system design and site requirement)
Note - for details refer tender document Schedule of Quanties Page SOQ 2 | 1 | Job | emcjabalpur1 | 300 |
| 3 | BOQ Item No - 3 | Design Supply, Installation, Testing and Commissioning (DSITC) of Grid Connected ground mounted DC Solar PV-module-based power supply system of capacity below mentioned with modules fixed in anodized aluminium frame complete as required including elevated structural support systems for all components after proper soil investigation / treatment as per site conditions, modular inverters with atleast 25 percent standby / spare capacity with required communication / data / control / power cables, safety system for reverse power protection, min IP65 rated DC DB / JB for connection of modules to inverters . . . . . . . solar power plant complete as required and as per technical specifications and other terms and conditions of the contract. It also includes provision of skilled / unskilled manpower as per the requirement (as and when required) for proper operation and routine maintenance of the said solar power plant during defects liability period (DLP) of 02 years as per specifications, terms and conditions of the tender document.
It also includes O and AICMC of above said solar power plant for 08 years after expiry of DLP of 02 years as per tender specifications, terms and conditions etc. completed as required.
Note -
The quoted rates are inclusive of 08 years of Operation and AICMC cost (after DLP period of 02 years). The share of O and AICMC and DSITC components are fixed. The O and AICMC component shall be 10 percent of quoted amount and DSITC component shall be 90 percent of the quoted amount.
Distribution of 10 percent . . . . .
Location - Safdarjung Airport
Capacity - 400 KW (AC)
Approx. distance of Evacuation point from solar installation - 1.8 Km
Evacuation point voltage level - HT / LT (as per system design and site requirement)
Note - for details refer tender document Schedule of Quanties Page SOQ 3 | 1 | Job | emcsafdarjung | 300 |
| 4 | BOQ Item No - 4 | Design Supply, Installation, Testing and Commissioning (DSITC) of Grid Connected ground mounted DC Solar PV-module-based power supply system of capacity below mentioned with modules fixed in anodized aluminium frame complete as required including elevated structural support systems for all components after proper soil investigation / treatment as per site conditions, modular inverters with atleast 25 percent standby / spare capacity with required communication / data / control / power cables, safety system for reverse power protection, min IP65 rated DC DB / JB for connection of modules to inverters . . . . . . solar power plant complete as required and as per technical specifications and other terms and conditions of the contract. It also includes provision of skilled / unskilled manpower as per the requirement (as and when required) for proper operation and routine maintenance of the said solar power plant during defects liability period (DLP) of 02 years as per specifications, terms and conditions of the tender document.
It also includes O and AICMC of above said solar power plant for 08 years after expiry of DLP of 02 years as per tender specifications, terms and conditions etc. completed as required.
Note -
The quoted rates are inclusive of 08 years of Operation and AICMC cost (after DLP period of 02 years). The share of O and AICMC and DSITC components are fixed. The O and AICMC component shall be 10 percent of quoted amount and DSITC component shall be 90 percent of the quoted amount.
Distribution of 10 percent . . . . . .
Location - Khajuraho Airport
Capacity - 500 KW (AC)
Approx. distance of Evacuation point from solar installation - 1.8 Km
Evacuation point voltage level - HT / LT (as per system design and site requirement)
Note - for details refer tender document Schedule of Quanties Page SOQ 4 | 1 | Job | techkhj | 300 |
| 5 | BOQ Item No - 5 | Design Supply, Installation, Testing and Commissioning (DSITC) of Grid Connected ground mounted DC Solar PV-module-based power supply system of capacity below mentioned with modules fixed in anodized aluminium frame complete as required including elevated structural support systems for all components after proper soil investigation / treatment as per site conditions, modular inverters with atleast 25 percent standby / spare capacity with required communication / data / control / power cables, safety system for reverse power protection, min IP65 rated DC DB / JB for connection of modules to inverters . . . . . . It also inculdes provision of skilled / unskilled manpower as per the requirement (as and when required) for proper operation and routine maintenance of the said solar power plant during defects liability period (DLP) of 02 years as per specifications, terms and conditions of the tender document.
It also includes O and AICMC of above said solar power plant for 08 years after expiry of DLP of 02 years as per tender specifications, terms and conditions etc. completed as required.
Note -
The quoted rates are inclusive of 08 years of Operation and AICMC cost (after DLP period of 02 years). The share of O and AICMC and DSITC components are fixed. The O and AICMC component shall be 20 percent of quoted amount and DSITC component shall be 80 percent of the quoted amount.
Distribution of 20 percent . . . . .
Location - Kandla Airport
Capacity - 100 KW (AC)
Approx. distance of Evacuation point from solar installation - 220 Mtrs
Evacuation point voltage level - HT / LT (as per system design and site requirement)
Note - for details refer tender document Schedule of Quanties Page SOQ 5 | 1 | Job | emckandla | 300 |
| 6 | BOQ Item No - 6 | Design Supply, Installation, Testing and Commissioning (DSITC) of Grid Connected ground mounted DC Solar PV-module-based power supply system of capacity below mentioned with modules fixed in anodized aluminium frame complete as required including elevated structural support systems for all components after proper soil investigation / treatment as per site conditions, modular inverters with atleast 25 percent standby / spare capacity with required communication / data / control / power cables, safety system for reverse power protection, min IP65 rated DC DB / JB for connection of modules to inverters . . . . . . It also inculdes provision of skilled / unskilled manpower as per the requirement (as and when required) for proper operation and routine maintenance of the said solar power plant during defects liability period (DLP) of 02 years as per specifications, terms and conditions of the tender document.
It also includes O and AICMC of above said solar power plant for 08 years after expiry of DLP of 02 years as per tender specifications, terms and conditions etc. completed as required.
Note -
The quoted rates are inclusive of 08 years of Operation and AICMC cost (after DLP period of 02 years). The share of O and AICMC and DSITC components are fixed. The O and AICMC component shall be 20 percent of quoted amount and DSITC component shall be 80 percent of the quoted amount.
Distribution of 20 percent . . . . .
Location - Jalgaon Airport
Capacity - 190 KW (AC)
Approx. distance of Evacuation point from solar installation - 200 Mtrs
Evacuation point voltage level - HT / LT (as per system design and site requirement)
Note - for details refer tender document Schedule of Quanties Page SOQ 6 | 1 | Job | emcjalgaon1 | 300 |
| 7 | BOQ Item No - 7 | Design Supply, Installation, Testing and Commissioning (DSITC) of Grid Connected Solar Carport with structure made up of aesthetically appealing GI steel tubular poles DC Solar PV-module-based power supply system of capacity below mentioned with modules fixed in anodized aluminium frame complete as required including elevated structural support systems for all components after proper soil investigation / treatment as per site conditions, modular inverters with atleast 25 percent standby / spare capacity with required communication / data / control / power cables, safety system for reverse power protection, min IP65 rated DC DB / JB for connection of modules to inverters . . . . . . . solar power plant complete as required and as per technical specifications and other terms and conditions of the contract. It also includes provision of skilled / unskilled manpower as per the requirement (as and when required) for proper operation and routine maintenance of the said solar power plant during defects liability period (DLP) of 02 years as per specifications, terms and conditions of the tender document.
It also includes O and AICMC of above said solar power plant for 08 years after expiry of DLP of 02 years as per tender specifications, terms and conditions etc. completed as required.
Note -
The quoted rates are inclusive of 08 years of Operation and AICMC cost (after DLP period of 02 years). The share of O and AICMC and DSITC components are fixed. The O and AICMC component shall be 20 percent of quoted amount and DSITC component shall be 80 percent of the quoted amount.
Distribution of 20 percent . . . . . .
Location - Bhatinda Airport
Capacity - 140 KW (AC)
Approx. distance of Evacuation point from solar installation - 500 Mtrs
Evacuation point voltage level - HT / LT (as per system design and site requirement)
Note - for details refer tender document Schedule of Quanties Page SOQ 7 | 1 | Job | emcbhatinda | 300 |
| 8 | BOQ Item No - 8 | Design Supply, Installation, Testing and Commissioning (DSITC) of Grid Connected Solar Carport with structure made up of aesthetically appealing GI steel tubular poles DC Solar PV-module-based power supply system of capacity below mentioned with modules fixed in anodized aluminium frame complete as required including elevated structural support systems for all components after proper soil investigation / treatment as per site conditions, modular inverters with atleast 25 percent standby / spare capacity with required communication / data / control / power cables, safety system for reverse power protection, min IP65 rated DC DB / JB for connection of modules to inverters ------------------ solar power plant complete as required and as per technical specifications and other terms and conditions of the contract. It also includes provision of skilled / unskilled manpower as per the requirement (as and when required) for proper operation and routine maintenance of the said solar power plant during defects liability period (DLP) of 02 years as per specifications, terms and conditions of the tender document.
It also includes O and AICMC of above said solar power plant for 08 years after expiry of DLP of 02 years as per tender specifications, terms and conditions etc. completed as required.
Note -
The quoted rates are inclusive of 08 years of Operation and AICMC cost (after DLP period of 02 years). The share of O and AICMC and DSITC components are fixed. The O and AICMC component shall be 10 percent of quoted amount and DSITC component shall be 90 percent of the quoted amount.
Distribution of 10 percent ---------
Location Prayagraj Airport
Capacity 600 KW (AC)
Approx. distance of Evacuation point from solar installation - 500 Mtrs
Evacuation point voltage level - HT / LT (as per system design and site requirement)
Note - for details refer tender document Schedule of Quanties Page SOQ 8 | 1 | Job | emcprayagraj | 300 |
| 9 | BOQ Item No - 9 | Design Supply, Installation, Testing and Commissioning (DSITC) of Grid Connected Solar Carport with structure made up of aesthetically appealing GI steel tubular poles DC Solar PV-module-based power supply system of capacity below mentioned with modules fixed in anodized aluminium frame complete as required including elevated structural support systems for all components after proper soil investigation / treatment as per site conditions, modular inverters with atleast 25 percent standby / spare capacity with required communication / data / control / power cables, safety system for reverse power protection, min IP65 rated DC DB / JB for connection of modules to inverters . . . . . . solar power plant complete as required and as per technical specifications and other terms and conditions of the contract. It also includes provision of skilled / unskilled manpower as per the requirement (as and when required) for proper operation and routine maintenance of the said solar power plant during defects liability period (DLP) of 02 years as per specifications, terms and conditions of the tender document.
It also includes O and AICMC of above said solar power plant for 08 years after expiry of DLP of 02 years as per tender specifications, terms and conditions etc. completed as required.
Note -
The quoted rates are inclusive of 08 years of Operation and AICMC cost (after DLP period of 02 years). The share of O and AICMC and DSITC components are fixed. The O and AICMC component shall be 10 percent of quoted amount and DSITC component shall be 90 percent of the quoted amount.
Distribution of 10 percent . . . . .
Location - Jharsuguda Airport
Capacity - 600 KW (AC)
Approx. distance of Evacuation point from solar installation - 500 Mtrs
Evacuation point voltage level - HT / LT (as per system design and site requirement)
Note - for details refer tender document Schedule of Quanties Page SOQ 9 | 1 | Job | emcjharsuguda | 300 |
| 10 | BOQ Item No - 10 | Design Supply, Installation, Testing and Commissioning (DSITC) of Grid Connected Solar Carport with structure made up of aesthetically appealing GI steel tubular poles DC Solar PV-module-based power supply system of capacity below mentioned with modules fixed in anodized aluminium frame complete as required including elevated structural support systems for all components after proper soil investigation / treatment as per site conditions, modular inverters with atleast 25 percent standby / spare capacity with required communication / data / control / power cables, safety system for reverse power protection, min IP65 rated DC DB / JB for connection of modules to inverters . . . . . . solar power plant complete as required and as per technical specifications and other terms and conditions of the contract. It also includes provision of skilled / unskilled manpower as per the requirement (as and when required) for proper operation and routine maintenance of the said solar power plant during defects liability period (DLP) of 02 years as per specifications, terms and conditions of the tender document.
It also includes O and AICMC of above said solar power plant for 08 years after expiry of DLP of 02 years as per tender specifications, terms and conditions etc. completed as required.
Note -
The quoted rates are inclusive of 08 years of Operation and AICMC cost (after DLP period of 02 years). The share of O and AICMC and DSITC components are fixed. The O and AICMC component shall be 20 percent of quoted amount and DSITC component shall be 80 percent of the quoted amount.
Distribution of 20 percent . . . . . .
Location - Hindon Airport
Capacity - 150 KW (AC)
Approx. distance of Evacuation point from solar installation - 500 Mtrs
Evacuation point voltage level - HT / LT (as per system design and site requirement)
Note - for details refer tender document Schedule of Quanties Page SOQ 10 | 1 | Job | emchindon | 300 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_4243684.pdf
GEM_BID
11-technical-specifications-04-01-2023_2023-01-09-11-08-58_f1fe560fefe092307e8528500fa46548.pdf
BOQ
final-working_2023-01-09-11-08-58_8168142a396d3f7f35a7e040fd63aeec.csv
BOQ
Download all tender documents and submit your bid