Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.6 LAccepted-AOC 02 PADRI SHIV NAGAR SHIV NAGAR MAHARAJGANJ UTTAR PRADESH 273303 | MAHARAJGANJ | UTTAR PRADESH | 273303 | L1 | Accepted-AOC AOC | |
| 2 | L2₹14.4 L+₹44,964 (3.21%)Rejected-Finance | L2 | Rejected-Finance NOT A LOWEST BID | |
| 3 | L3₹15.0 L+₹1.0 L (7.44%)Rejected-Finance | L3 | Rejected-Finance NOT A LOWEST BID | |
| 4 | L4₹18.0 L+₹4.0 L (28.3%)Rejected-Finance OFFICE NO 101 MALAN PLAZA NEXT TO ESSAR PETROL PUMP NEAR GODAMBLE CORNER RAHATNI PIMPRI DP ROAD RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | L4 | Rejected-Finance NOT A LOWEST BID | |
| 5 | L5₹18.0 L+₹4.0 L (28.8%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L5 | Rejected-Finance NOT A LOWEST BID |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
11 Feb 2020, 6:00 pmClosed
GE MH RH KIRKEE
GE MH RH KIRKEE RANGE HILLS ROAD KIRKEE PUNE 411003
REPAIR MAINTENANCE AND RENEWAL OF INTERNAL ELECTRIC WIRING INCLUDING REPAIRS OF FANS GEYSERS OF CERTAIN OTM AND MD ACCN OFFRS JCOS AND ORS MAP AT AUNDH MIL STN UNDER GE MH AND RH KIRKEE
2020_MES_314688_1
8101/E8
Open Tender
Civil Works
Works
270 days
KIRKEE AND AUNDH
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE MH RH KIRKEE
₹40,000
Yes
12 Mar 2020
14 Jan 2020
12 Feb 2020
14 Jan 2020
11 Feb 2020
28 Jan 2020
14 Jan 2020 - 21 Jan 2020
Amount
M & L for point wiring complete with and including 1.5 sqmm (nominal area) single core multi stranded copper conductor PVC insulated but unsheated FRLS cable 1100 Volts drawn in to and including PVC casing caping ISI marked of suitable size including its accessories such as tee, bend ,elbow, socket complete and making good the disturbed surfaces of wall / ceiling by cement mortar 1:4 including painting to existing surfaces and also including 1.5 sqmm PVC insulated and PVC unsheathed single core multistranded copper conductor FRLS cable 1100 V grade as earth wire ISI marked of suitable size / 3 mm thick hylam sheet on MS terminal box sunken to wall for housing switch ,socket,regulators etc including taking down old unserviceable/burnt point wiring of any type or size complete for One light point controlled by one switch.
All as per item No 1 above but One Fan point controlled by one switch
All as per item No 1 above but One 5 pin 6 Amps socket outlet on independent board.
All as per item No 1 above but One 5 pin 6 Amps socket outlet on same board.
All as per item No 1 above but bell /buzzer point controlled by one push button on the same board with other switches or indipendent with cables 1.5 sqmm size.
All as per item No 1 above but one light point controlled by two way switch.
All as per item No 01 here-in-before but wiring with 2.5 sqmm single core multi stranded copper condcutor 1100 v grade PVC insulated but unsheheted copper conductor FRLS cable 1100 volts grade and 2.5 sqmm PVC insulated but unsheathed FRLS cable as earthwire for 16 Amps power point on independent board complete including taking down old unserviceable/burnt wiring of any type or size all as specified and directed by Engr-in-charge.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. and making good disturbed surfaces of walls, floors, etc. and M & L for point wiring complete with and including 1.5 sqmm (nominal area) single core multi stranded copper conductor PVC insulated but unsheated FR cable 1100 Volts drawn in to and including PVC rigid metallic / non metallic existing concealed conduit ISI marked of suitable size including its accessories such as tee, bend ,elbow, socket and if required chisselling on wall complete and al so making good the disturbed surfaces of wall / ceiling by cement mortar 1:4 including painting to existing surfaces and also including 1.5 sqmm PVC insulated and PVC unsheathed single core multistranded copper conductor FR cable 1100 V grade as earth wire including concealed MS terminal box ISI marked of suitable size / 3 mm thick hylam sheet on MS terminal box for housing switch ,socket,regulators etc complete for One light point controlled by one switch.
All as per item No 8 above but One Fan point controlled by one switch
All as per item No 8 above but One 5 pin 6 Amps socket outlet on independent board.
All as per item No 8 above but One 5 pin 6 Amps socket outlet on same board.
All as per item No 8 above but bell /buzzer point controlled by one push button on the same board with other switches or indipendent with cables 1.5 sqmm size.
All as per item No 8 above but one light point controlled by two way switch.
All as per item No 08 here-in-before but wiring with 2.5 sqmm single core multi stranded copper condcutor 1100 v grade PVC insulated but unsheheted copper conductor FRLS cable 1100 volts grade and 2.5 sqmm PVC insulated but unsheathed FRLS cable as earthwire for 16 Amps power point on independent board complete including taking down old unserviceable/burnt wiring of any type or size all as specified and directed by Engr-in-charge.
S & F switch piano type pole one way 6 Amps including taking down old unserviceable/burnt piano switch all as specified and directed by Engr-in-Charge.
S & F switch piano type 16 Amps including taking down old unserviceable/burnt piano switch all as specified and directed by Engr-in-Charge.
S&F Bell push, flush type, 6 Amp including taking down old unserviceable/burnt piano switch all as specified and directed by Engr-in-Charge.
S & F switch piano type two way 6 Amps including taking down old unserviceable/burnt piano switch all as specified and directed by Engr-in-Charge.
S & F socket outlet 2 in1,3 pin 5 Amps including taking down old unserviceable/burnt socket all as specified and directed by Engr-in-Charge.
S & F socket outlet 2 in 1, 3 pin, 6 and 16 Amps flush type including taking down old unserviceable/burnt p socket all as specified and directed by Engr-in-Charge.
S & F fan regulator suitable for 1200/1400 mm ceiling fans (electronics step type) Make-Anchor
S & F PVC ceiling rose/ lamp holder angle / battam PVC type including taking down old unserviceable all as specified and directed by Engr-in-Charge.
S & F Buzzer / call bell/ ding dong AC 230 volts, 6 Amp single Phase in white /Ivory colour finish including PVC mounting block complete all as specified and directed
Taking down old unserviceable conventional fitting and S & F wall mounted high quality indoor batten LED tube light with PVC housing,T-8 LED tube rod 18 Watt with T-8 LED Batten type with integral electronic driver 18 W, colour temperature 6500 K (4') , operating lifte 50000 hrs, lumen 1800-3000, diffused connecting with three core flexible copper wire from connector to ceiling rose / Angle Holder as per existing site requriement as directed by engineer in charge. Make: Havells / Bajaj / Philips / Crompton Greaves
Taking down old unserviceable conventional light fitting and S & F wall/ceiling mounted high quality indoor T-8 LED tube light 10 watt with PVC housing and T-8 batten with intergrated electronic driver 10 watt, colour temperature 6500 K, operating life 30000 hrs, 900-1350 lumen (2'), diffused connecting with three core flexible coopper wire from connector to ceiling rose/ Angle Holder as per existing site requriement as directed by engineer in charge. Make: Havells / Bajaj / Philips / Crompton Greaves
S & F in repairs 30 W Street /buidling security light fitting cast aluminium housing, toughened glass, IP 65/66, and pre wired with all accessories complete including entry for mounting on pipe bracket including extendable/supported 40 mm GI medium grade pipe of suitable size bracket bend to shape fixed as on wall / pole with suitable size of MS flat iron clamps 02 nos including grouting on wall / fixed on pole with nut, bolts and washers and painting with single coat of aluminium paint over one coat of primer on MS items complete all as specified & directed. Make; Havells / Bajaj /Crompton Greaves/Philips.
Supply and fixing including taking down MCCB, 3 pole, 36 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, upto 100 amps, incl dismentling taking down unsv one, make- L & T Schneider/ABB /Legrand/Merlin Gerin.
Supply and fixing including taking down MCCB, 4 pole, 36 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, upto 160 amps, incl dismentling taking down unsv one, make- L & T Schneider/ABB /Legrand/Merlin Gerin.
S & F distribution board factory made TPN 4 way in, 415 Volt, Double door metal type suitable for fixing MCBs as out going and including TPN MCB 63 Amps as main incoming all as specified & directed. Make; Legrand / L&T / ABB. Note; Cost of MCBs will be measured and paid seperately.
S & F distribution board factory made SPN 4 way in, 240 Volt, Double door metal type suitable for fixing MCBs as out going and including SPN MCB 32 Amps as main incoming all as specified & directed. Make; Legrand / L&T / ABB. Note; Cost of MCBs will be measured and paid seperately.
S & F distribution board factory made SPN 8 way in, 240 Volt, Double door metal type suitable for fixing MCBs as out going and including SPN MCB 32 Amps as main incoming all as specified & directed. Make; Legrand / L&T / ABB. Note; Cost of MCBs will be measured and paid seperately.
S & F Isolator TPN 63 Amps Make Anchor/ Legrand/ Seimense /ABB
S & F Isolator TPN 100 Amps Make Anchor/ Legrand/ Seimense /ABB
S & F MCB SPN 10 to 32 Amps .Make Havells/ Anchor/ Legrand/ Seimense /ABB
S & F MCB SP 5 to32 amps, .Make Havells / Anchor/ Legrand/ Seimense /ABB
M&L for sub main wiring but using two single core multistranded PVC insulated copper conductor FRLS Cable of size 4 sqmm 1100 volt grade drawn into PVC casing capping of suitable size including 4 sqmm. PVC multi standard copper conductor FRLS cable in green colour for continious earthing including chislling/cutting of wall, floor, making hole through wall & making good disturbed surfaces of wall/floor/ceiling to match with existing surface including taking down old unserviceable/burnt wiring of any type or size all as directed by Engr-in-Charge..
M&L for sub main wiring but using two single core multistranded PVC insulated copper conductor FRLS Cable of size 6 sqmm 1100 volt grade drawn into PVC casing capping of suitable size including 6 sqmm. PVC multi standard copper conductor FRLS cable in green colour for continious earthing including chislling/cutting of wall, floor, making hole through wall & making good disturbed surfaces of wall/floor/ceiling to match with existing surface including taking down old unserviceable/burnt wiring of any type or size all as directed by Engr-in-Charge..
M & L for repairs to storage type elect. water heater (geyser) of storage capacity 25/35/50 ltrs of any make comprising of the following tasks at different locations as directed by Engineer -in-charge. (a) Inspection, taking down, opening ( dismantling ) descaling, brushing, cleaning of storage tank and painting internally with one coat of proprietary bituminous composition not liable to impart test or otherwise contaminate the water. (b) Examine water tightness of storage tank after cleaning . (c) Carry out operation of all stop cocks, pressure reducing valves etc. to ensures free movement of the working parts. (d) Replace washers and glands of all taps and ball valves to ensure water tightness. (e) Inspect overflow / vent pipes and remove blockages obstructions if any. (f) Check and correct earth continuty of eletrical items. (g) Check maintain and refit thermostates and test its functioning. (h) Checking and adjustment of pressure reducing valves. (j) Visual examination of fusible plug to ensure its intactness and replace the same if found unserviceable. (k) Descaling of the immertion type heating element and cleaning with diluted hydrocloric acid or clear pedette solution and testing before refixing. (l) Replacement / repair of neon lamp / indicator lamp. (m) Replacement of the rubber / PVC gasket to ensure water tightness. (n) Testing of geysers after repairs.
S & F in repairs thermostats ISI marked as required at site for geyser of capacity 25/35/50 Ltr of any make all as directed by Engr-in-charge
S & F in repairs of safety valve/high pressure valve ISI marked as per site requirement or all as per directed by Engineer-in-Charge.
S & F in repairs heating element of rating 1.5/2 KW as required at site including rubber washers all as specified and directed by Engr-in-charge..
S & F in repairs of PVC pipe with brass hexagonal adopters both side, suitable for 15 mm dia pipe 45 cm long for cold water connection all as specified and directed by Engineer-in-charge.
S & F in repairs metal braided PVC/CP pipe with brass hexagonal adopters both side, suitable for 15 mm dia pipe 45 CM long for hot water connection all as specified and directed by Engineer-in-charge.
S & F in repairs, non return valve 15 mm dia of brass, ISI marked all as specified and directed by Engineer-in-charge.
M & L for preparation of steel surface and applying of one coat of syntheic enamel paint white including writing of MES Nos with black paint complete to geysers of any capacity or make all as specified and directed by Engineer-in-charge.
S&F Metal plug top 20 Amps for single phase application.
M & L for stop valve, cast copper alloy screw down high pressure crutch handle, screwed both end for iron pipe suitable for 15 mm bore
M & L for rewinding of ceiling fans of 1200 mm sweep of any make with supper enamelled copper winding wire appropriate gauge and after cutting the old burnt winding and cleaning the slots including varnishing and replacement of flexible cable 23/0.0076 mm to the required length, replacement of unserviceable bearing, capacitor as required including taking down and refixing, making connection and testing complete all as specified and directed by Engr-in-Charge. Note : (a) The winder of the contractor will collect the ceiling fans from user's Accn by the advice of MCM IC Complaint Cell and rewind the same in workshop. After rewinding, the same will be deposited with the MCM I/C duly tested and then fitted at site. (b) Bearing will measured and paid separately under relevant item of sch
All as per item No 48 above but Exhaust Fan of sweep 225-450 mm
M & L ball bearing to match the existing make suitable for 1200/1400 mm sweep ceiling fan including greasing complete all as specified and directed by Engr-in-charge. Make : SKF/NBC or equivalent
M & L ball bearing to match the existing make suitable for 225-450 mm exhaust fan inclduing greasing. Make : SKF/NBC or equivalent
S&F in repair of rotor shaft for ceiling fan 1200/1400 mm sweep as directed by Engr-in-charge
M & L only capacitor 2.5/4 mfd for ceiling fan all as specified and as directed by Engr-in-chargeMake:Havells/Epcos)
M & L Painting and overhauling of building panel board including one coat to red oxide and two coat of synthetic enamlled paint & necessary welding to hinges including replacement of PVC cable with new connection wire stranded FRLS of 4 sqmm two run from TPN DB to existing electric meter, replacement of bottle lugs, connection wire from DB to meter including New PVC Cable tray 35 mm X 25 mm, cable glands etc. necessary connection wire to meter, GI nut bolts, GI washers, Fastern bolts for 9/6 Quarters of MD Accn all as directed by engineer-in-charge. Note : TPN DB and MCB's will be measured and paid seperately.
M & L for earthing complete with galvansihed steel earth plate electrode 600 mm x 600 mm x 6.3 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level connected to 4.0 mm dia galvansihed earth lead wire by means of nuts bolts check nuts and GI washers including PCC pit in PCC 1:2:4 type B-1 RCC cover 20 mm dia (medium grade) GI watering pipe with funnel wire mesh and protection pipe of GI of suitbale size upto 7.5 mtr length including charcoal black cotton soil as required at site to achieve the earthing result and common salt, excavation earth work etc in any type of starta complete all as shown in electrical palte No 3 of SSR part-I, GI wire suitable size and length for continuity earth wire from test point to main distribution Board and all as directed. (Note: Rate for achieving required depth by compressor machine/breaker if required is deemed included in item unit rate.)
M & L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire all as directed by Engr-in-Charge
PURVA ELECTRICALS AND ENGINEERS
M/S VR Construction Services
M/S. Niksun Electro-Infra Private Limited
metro electrical services
PAMS ENTERPRISES
ANUSHKA BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .