Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.6 LAccepted-AOC A 63 ELDECO COUNTY PHASE II RAJGARH JHANSI U P 284135 | JHANSI | JHANSI | UTTAR PRADESH | 284135 | L1 | Accepted-AOC Being a L1 bidder | |
| 2 | L2₹32.7 LSame as L1Rejected-Finance 1308 MAIN ROAD BABINACANTT DIST JHANSI 284 401 | BABINA | JHANSI | UTTAR PRADESH | 284401 | L2 | Rejected-Finance Please refer
para 3.17
on page No
48 of
Manual on
Contracts
2007
(Reprint
2012) | |
| 3 | L3₹32.7 L+₹3,535.23 (0.11%)Rejected-Finance VILLAGE TAPARIYAN BABINA CANTT BABINA JHANSI UP 284401 | BABINA | JHANSI | UP | 284401 | L3 | Rejected-Finance Not being a
lowest
tender | |
| 4 | L4₹35.4 L+₹2.7 L (8.29%)Rejected-Finance 640 MAIN ROAD BABINA CANTT JHANSI UP 284401 | BABINA | JHANSI | UTTAR PRADESH | 284401 | L4 | Rejected-Finance Not being a
lowest
tender | |
| 5 | L5₹37.4 L+₹4.7 L (14.3%)Rejected-Finance 24 824 GOVERDHAN COLONY MAIN BHIND ROAD GOLE KA MANDIR | L5 | Rejected-Finance Not being a
lowest
tender |
Tender Value
Refer Docs
EMD Value
₹85,500
Closing Date
19 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE BABINA
GE BABINA CANTT 284401
OUTSOURCING OF SERVICES FOR MAINT AND OPERATION OF ELECTRIC POWER HOUSE, KLP AREA AND CONNECTED REPAIR WORKS AT BABINA CANTT UNDER GE BABINA
2020_MES_397206_1
GE/BAB/TOKEN /59 OF 2020-2021
Open Tender
Miscellaneous Works
Item Rate
330 days
GE BABINA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE BABINA
₹85,500
Yes
31 Dec 2020
21 Nov 2020
21 Dec 2020
21 Nov 2020
19 Dec 2020
5 Dec 2020
60 days
Amount
(PART-A) In case quoted amount of part-A are less than minimum wages including statutory provisions mentioned here in below the tender will be treated as NON BONAFIDE and will not be considered for acceptance.
Manning and operation of MES electric installations/ receiving cum distribution 11 KV Sub Station in KLP area for loacation of sub station No 'A' by deploying of 01 electrician ( Skilled Electrician ) in 3 continuous shift of 08 hours each { One electrician in each shift of 08 hours (Total No of electrician = 03 Nos for one day)} including Sundays & holidays for successfully running/ functioning of complete HT/LT installations etc complete all as specified and directed. Note : (i) 1st shift from 0600 hrs to 1400 hrs one electrician. (ii) 2nd shift from 1401 hrs to 2200 hrs one electrician. (iii) 3rd shift from 2201 hrs to 0600 hrs one electrician.
Manning and operation of MES electric installations/ receiving cum distribution 11 KV Sub Station in KLP area for loacation of JCO’s/OR and Officer living MAP PH-II Sub stn by deploying of 01 electrician ( Skilled Electrician ) in 2 continuous shift of 08 hours each { One electrician in each shift of 08 hours (Total No of electrician = 02 Nos for one day)} including Sundays & holidays for successfully running/ functioning of complete HT/LT installations etc complete all as specified and directed. Note : (i) 1st shift from 0600 hrs to 1400 hrs one electrician. (ii) 2nd shift from 1401 hrs to 2200 hrs one electrician.
Manning and operation of MES electric installations/ receiving cum distribution 11 KV Sub Station in KLP area for loacation of sub station No 'C' by deploying of 01 electrician ( Skilled Electrician ) in 3 continuous shift of 08 hours each { One electrician in each shift of 08 hours (Total No of electrician = 03 Nos for one day)} including Sundays & holidays for successfully running/ functioning of complete HT/LT installations etc complete all as specified and directed. Note : (i) 1st shift from 0600 hrs to 1400 hrs one electrician. (ii) 2nd shift from 1401 hrs to 2200 hrs one electrician. (iii) 3rd shift from 2201 hrs to 0600 hrs one electrician.
Manning and operation of MES electric installations/ receiving cum distribution 11 KV Sub Station in KLP area for loacation of sub station R Well by deploying of 01 electrician ( Skilled Electrician ) in 2 continuous shift of 08 hours each { One electrician in each shift of 08 hours (Total No of electrician = 02 Nos for one day)} including Sundays & holidays for successfully running/ functioning of complete HT/LT installations etc complete all as specified and directed. Note : (i) 1st shift from 0600 hrs to 1400 hrs one electrician. (ii) 2nd shift from 1401 hrs to 2200 hrs one electrician.
Rate required to be quoted for execution of the work as described in 2 to 5 here-in-before for the following :-
01 Skilled Electrician (Per shift) wages as per Minimum wages as per as latest notification issued by Government of India/ State Government/ Local body whichever is higher as on bid submission end date.
ESI (Insurance cover) @ 3.25% on minimum wage. If monthly minimum wages are exceeding Rupees twenty one thousand (Rs 21,000/-), ESI shall be exempted on minimum wages at Ser No 6.02.
EPF (Employee provident found) @ 13.00% on minimum wage. If monthly minimum wage are exceeding Rupees fifteen thousand (Rs 15,000/-). EPF shall be calculated for amount Rupees fifteen thousand (Rs 15,000/-) only on minimum wages at Ser No 6.02.
Contribution of bonus @ 8.33% on minimum wage at Ser No 6.02.
Over head & Contractor's profit.
Labour cess @ 1% on totoal amount of Ser No 6.02 to 6.06.
GST @ 18% on total amount of Ser No 6.02 to 6.07.
(Part-B)
S&F 1100 Volts grade heavy duty cable PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape & overall PVC sheathed in service connections , of following sizes.(Make :- Havells, Plaza cables, Polycab, Finolex or equivalent.) : -
one twin core cable flat or circular of size 16 sqmm
one twin core cable flat or circular of size 10 sqmm
S & F in replacement of change over switch with advanced neutral, ON LOAD, 63 Amps, 4 pole, AC 415 Volt, manual Change Over in sheet metal enclosure with operating side handle conforming to IS:60947 (Part-1&3) with all fixing arrangement on walls/angular frame including taking down of existing complete all as specified and directed. Make : Havells cat part No IHCFFE0063 /L&T/Indoasian
Description all as per item No 9 here in above but of capacity 100 Amps with ultimate breaking capacity 16 KA and -ditto-
Description all as per item No 9 here in above but of capacity 200 Amps with ultimate breaking capacity 16 KA and -ditto-
Description all as per item No 9 here in above but of capacity 315 Amps with ultimate breaking capacity 16 KA and -ditto-
Description all as per item No 9 here in above but of capacity 1000 Amps with ultimate breaking capacity 16 KA and -ditto-
S & F in replacement of MCCB, 04 Pole, capacity 40 Amps with ultimate breaking capacity 16 KA at 415 volts with fixed thermalsettings conforming to IEC 60947 Part-I/IS-13947 Part-I , (Ics=Icu=100%) in the existing panel with suitable connecting copper terminals at site complete all specified and directed. Make : Siemens, Schneider, ABB, AREVA, GE INDIA
Description all as per item No 14 here in above but of capacity 63 Amps with ultimate breaking capacity 16 KA and -ditto-
Description all as per item No 14 here in above but of capacity 100 Amps with ultimate breaking capacity 25 KA and -ditto-
Description all as per item No 14 here in above but of capacity 160 Amps with ultimate breaking capacity 25 KA and -ditto-
Description all as per item No 14 here in above but of capacity 200 Amps with ultimate breaking capacity 25 KA and -ditto-
Description all as per item No 14 here in above but of capacity 250 Amps with ultimate breaking capacity 25 KA and -ditto-
Description all as per item No 14 here in above but of capacity 315 Amps with ultimate breaking capacity 35 KA and -ditto-
Description all as per item No 14 here in above but of capacity 400 Amps with ultimate breaking capacity 35 KA and -ditto-
Description all as per item No 14 here in above but of capacity 630 Amps with ultimate breaking capacity 50 KA and -ditto-
M & L for disconnecting & taking out old/defective Current Transformer from 11 KV VCB panel, S & F installation & testing of Current transformer, indoor, comprising of 3 Nos single phase resin cast CTs of 300-150 / 5+5 Amps ratio, PS class, dual core with suitable VA burden and accuracy suitable for protection & metering incl making suitable arrangement for fixing in existing VCB panel and connection complete all as specified and directed. Make :- L&T /Crompton/ABB/C&S
Description all as per item No 23 here in above but ofcurrent ratio 100-50 / 5+5 Amps dual core and -ditto-
Description all as per item No 23 here in above but ofcurrent ratio 60-30 / 5+5 Amps dual core and -ditto-
laying only connecting,testing & commissioning underground cable, PVC insulated, armoured heavy duty electric cable with aluminium conductor of sizes 120 to 400 Sqmm 1100 volts grade inreplacement complete as directed by Engr-in -charge. The rate includes the connection of cable by providing copper thimbels at two ends of cables properly. Note The cables for laying shall be issued by department as Sch B
Excavation in trenches n. exc 1.5 mtr wide and n. exc 1.5 mtr depth for pole / cable / foundation etc including getting out in soft /loose soil complete all as specified and directed.
Returning, filling in, approved earth including spreading, levelling, watering and well ramming in layers n.exc 25 Cm thick after cable are laid and tested complete all as specified and directed.
Removing excavated material / surplus soil to a distance not exc. 50 mtrs & deposited where directed at a level not exc.1.5 mtr above the ground level complete all as specified & directed.
M&L for fine and clean sand (river sand) free from sharp materials in trenches for cushioning of cable 8 cm thick under cable and 15 cm thick over the cable including gently punning complete all as specified and directed . Note:- The total thickness of sand shall be measured 18 cm after punning.
Supplying and laying precast concrete cable cover class LV type -I flat size 250x150x40 mm laid parpendicular to the axis of cable in trenches etc complete as directed. Make: M/S MEHATAB TILES, Rani Shopping Centre, Bhanwar, Indore,(B) M/S NAVYA TILES, 68, NEHRU PARK, SARDARPUR,JODHPUR- 342003 Ph. 0291-2650094, 2627963(C) SAP PAVERS JODHPUR (D) SAGAR TILES SAHARANPUR (E) Star Tiles & Industries, Rama Devi, Kanpur
M & L for disconnecting & taking out old/defective PT from 11 KV VCB panel and S & F installation & testing of PT, indoor, comprising of 3 Nos single phase resin cast PTs of 11KV/110 Voltage ratio, 50 Hz PS class, with suitable VA burden and accuracy suitable for protection & metering incl making suitable arrangement for fixing in existing VCB panel and connection complete all as specified and directed. Make :- L&T /Crompton/ABB/C&S
S & F in replacement of 11 KV Silicon polymeric composite Disc insulator B&S type incl galvanised mild steel strap 38 mm X 5 mm, insulator bolts 20 mm dia with suitable washers and nut, suitable for working pressure upto 12 KV as per IS 731/1971 or latest amendment complete all as specified and directed
S & F in replacement of 11 kv silicon polymeric pin insulator, including one galvanized mild steel spindle two galvanised iron washers and one galvanised iron nut,11000 volt grade suitable for working pressure 12 KV as per IS 731/1971 or latest amendment complete all as specified and directed .
ROHIT ENTERPRISES
M/S Kharya Associates
m/s gupta trading
M/s Ravi Traders
anand enterprises
DIAMOND ELECTRICALS
Bal Singh and Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .