Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.3 LAccepted-AOC CHAMAVILA CHEELI CHITTADI POST PALAKKAD DIST KERALA 678706 | PALAKKAD | KERALA | 678706 | ₹47.3 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹48.2 L+₹90,341 (1.91%)Rejected-Finance | ₹48.2 L+₹90,341 (1.91%) | L2 | Rejected-Finance BEING NOT LOWEST TENDER |
| 3 | L3₹48.9 L+₹1.5 L (3.26%)Rejected-Finance D 235 ADG P CHENNAI | CHENNAI | TAMIL NADU | 600001 | ₹48.9 L+₹1.5 L (3.26%) | L3 | Rejected-Finance BEING NOT LOWEST TENDER |
| 4 | L4₹48.9 L+₹1.6 L (3.34%)Rejected-Finance | ₹48.9 L+₹1.6 L (3.34%) | L4 | Rejected-Finance BEING NOT LOWEST TENDER |
| 5 | L5₹49.0 L+₹1.7 L (3.64%)Rejected-Finance | ₹49.0 L+₹1.7 L (3.64%) | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
24 Feb 2020, 6:00 pmClosed
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
REPAIR MAINT TO BARBED WIRE FENCING BRICK STONE MASONARY WORK PATHWAYS CHAIN LINK FENCING BOUNDRY WALL INCLUDING PCC COPING AND OTHER MISC B R WORK AT AFS SULUR
2020_MES_321315_1
GE(AF)/SUL/Token/60 of 2019-2020
Open Tender
Miscellaneous Works
Item Rate
240 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE AF SULUR
₹98,000
Yes
6 Mar 2020
3 Feb 2020
25 Feb 2020
3 Feb 2020
24 Feb 2020
17 Feb 2020
3 Feb 2020 - 15 Feb 2020
Amount
SCHEDULE A BOQ
Dismantling timber scantling 40 sqcm and over in section in any position as in framed work.
2nd class softwood clean sawn boards or planks 40mm thick, width n exc. 25 cm with plain head, lost head,lath, mild steel wire nails exceding 50mm but not exceeding 80mm, bright finish complete all as specified and as directed
Demolition of Brick/stone masonary work built in cement mortor including all quoins arches pillars etc complete, all as specified.
Brickwork with sub class `B' Bricks straight or curved on plain exceeding 6 m mean radius built in CM 1:4 complete all as specified and as directed
Brickwork with sub class `B' Bricks straight or curved on plan to any radius built in CM 1:4 in half brick thick wall all as specified and directed by Engineer In Charge
Framed work such as ladders framed back stress walkways, railings and similar work conforming complete all as specified and as directed unserviceable CGI sheets in repairs.
Cement concrete in foundations, filling and mass concrete 1:4:8 type D2 40mm graded aggregate complete all as specified and as directed
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and as directed
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and as directed
Cement concrete type B-2, 1:2:4 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and as directed
Posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed in repairs. Make : TATA/ TISCO
Providing precast cement concrete 1:2:4 type B0 jallies, 45mm thick (measured solid) including all moulding but excluding frame set in CM 1:6 all as specified and directed in repairs.
Pre painted Coloured Galvalume roofing system sheet 0.50 mm thick having Zinc aluminum alloy coating AZ150 shall be as per IS:277/ASTM 1379 150 gsm/ sqm double ribbed trapezoidal profile steel sheet any colour having tensile strength of 550 Mpa as in Roof covering /cladding to wall fixed with self tapping screws including dismantling of old CGI sheeting complete all as directed.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws including dismantling of old PGI sheeting as specified
Note for Pre-painted coloured Galvalume roofing :-
(i) The manufacturer's test certificate and individual test certificate for the chemical and mechanical properties of sheet must be submitted for approval by the concerned authority prior to installation.
(ii) The contractor shall ensured that no leakages take place from the roof. The roofing shall be Coloured Galvalume roofing system (olive green colour or as approved by GE) with feed material manufactured from 0.50 mm Total coated thickness (TCT), minimum 550 MPa yield strength and shall conform to the physical specifications of IS: 2062 of 2011, coated with hot dip metallic Aluminium / Zinc alloy coating AZ150 as 150 gm/sq.mt total on both sides.
(iii) The painting shall be coloured baked enamel polyester with silicon coating of film thickness 25 microns nominal on the exposed face/exterior side and on the reverse side ( interior face) shall be white with 15 microns film thickness, over a coat of 5 micron nominal thickness Primer.
(iv) The contractor shall produce purchase vouchers for each lot for verification of Engineer-in-Charge.
Removing excavated material exc. 1.50km but n exc. 5km and depositing where directed complete all as specified and as directed
RCC 1:2:4 using (20mm graded aggregate as in coping including, weathering slightly or unded or chemfered angles and throating etc, including form work complete
Preparation of plastered or un plastered new surfaces of walls, etc. by brooming down or steel wire brushing scrapping down, smoke shoots moulds, mass efforescent salt, treating oil and greasy spots ect and applying two coats of cement based paint complete all as specified and directed.
Deformed TMTsteel bar of grade Fe-500/500D , 6 mm dia to 8 mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed in repairs.
Cement concrete 1:4:8 type D-2 ,100 mm thickness ( using 40 mm graded stone aggregate) to recive tile and including demolish existing concrete complete all as specified and directed in repairs.
chequered cement concrete tiles 30cm x 30 cm x 25 mm thick , set, jointed and pointed in neat slurry in floors , with grey cement and pigments, laid over and including cement screed bed 15 mm thick in CM 1:4 complete including demolish existing tile all as specified and directed in repairs.
Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size, polished confirming to IS-15658 of 60mm thickness M-35 grade, laid over and including M sand cushion of 50mm thick complete all as specified and directed in repairs. Note : The Unit rate quoted is included for Demolition of Stone Slabs and tiles of any description or thickness in floors,aprons etc laid bedded and pointed in any mortar
100mm thick, plain cement concrete (1:2:4), type B-2 (using 40 mm graded mechanically crushed stone aggregates), laid in 1:20 slope as in hard standing including making joints 1t 3.00 metre intervals and at each corner, the joint shall be filled with mastic filling (to full depth) comprising of one part heated hot blown bitumen 85/25 & two parts heated sand (by volume), surface finished even and smooth without using extra cement, complete including demolish existing concrete as specified and as directed including removal of debris outside MD land as directed. Note :- The concrete shall be laid at a stretch not exceeding 3 metre in length and width of joint shall not be more than 12 mm.
Stainless steel (Grade 304) hollow round or square pipe of any dia/ size fixed as in posts/ railing with knock-down fixing system & Top Mounted Round Balaster made of 38 to 50mm dia stailness steel 304 grade, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stailness steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stailess steel dash fasteners, stainless steel bolts etc, of required size suitable arrangement as per approval of Engineer-in-charge for any height including taking down old railing and make good the surfaces as required completed all as specified and as directed. Note :- The distance between vertical stailness steel posts should be as site requirement centre to centre.
Vitrified Ceramic tiles 10 mm thick, dark shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer ,15 mm thick in Cement Mortar 1:6 including taking down existing tile and removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
Note : (a) Vitrified tiles are classified under group B1a of the international Standard for ceramic tiles ISO: 13006. Tiles shall be hard, dense, impervious and frost resistant. Water absorption of tiles shall be less than 0.5% and flexural strength (Modulus of Rupture) shall be more than 35 N/Sqmm.
(b) The manufacturer's test certificate and individual test certificate for tiles must be submitted for approval by the concerned authority prior to installation.
Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other to be fitted with washers and one hexagonal or square nuts, n exc 5cm long diameter of neck 5 to 10mm complete all as specified and as directed in repairs.
preparation of new steel surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide complete all as specified and as directed in repairs.
Straining and fixing only chain link fencing including line wires, any mesh size and type of to any type of standards, rails, straining bolts etc inclunding provision 10mm dia MS bars as line wire welded to fencing posts and MS flat iron for fixing fencing wire mesh and including dismantling of fencing wire mesh of any type complete all as specified and directed.
Supply only Chain link mesh and made of galvanised wire and shall confirm to IS 2712.2003 and having zinc coating of type heavy as laid down in IS 4826 including line wires/ binding wire etc fixed to any type of standards posts complete all as specified and directed. Note :- Weight of chain link fencing to be assesed by BOO order by the GE prior to execution.
Taking down cement plaster on brick or stone walls, or concrete or ceilings etc., including raking out joints, hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises, removal and depositing serviceable materials where directed and leaving the work clear of any plastering and Rendering 15 mm thick in two layers on brick or stone or concrete surfaces,first coat 10mm thick in cement mortar 1:4 and 2nd coat 5mm thick in cement mortar 1:4 mixed with water proofing compound as per manufacturer instructions finished even and smooth without using extra cement complete all as specified and directed. Note: (a) Water proofing compound shall be measured and paid seperately. (b) The unit rate quoted is deemed to included for Removing of accumulated earth of any width and depth upto 15 cm cleaning/cutting the grass with hand operated petrol/kerosene driven grass cutting machine and removing the grass waste around 3 m from plinth protection to outside MD land Note: Periodicity of cutting of grass shall be before commencement of work and after completion of repairs.
Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing complete all as specified and as directed in repairs.
Deformed TMTsteel bar of grade Fe-500/500D , 5 mm dia to 10 mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips in stirrups , spacers and binders etc complete all as specified and directed in repairs.
Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size, polished confirming to IS-15658 of 80mm thickness M-40 grade, laid over and including M sand cushion of 50mm thick complete all as specified and directed including removal of debris outside MD land as directed. Note : The Unit rate quoted is included for Demolition of Stone Slabs and tiles of any description or thickness in floors,aprons etc laid bedded and pointed in any mortar
Vitrified Ceramic tiles 10 mm thick, dark shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in vertical surfaces such as dedo/ skiting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer, 10 mm thick in Cement Mortar 1:3 including taking down existing tile and removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. Note : (a) Vitrified tiles are classified under group B1a of the international Standard for ceramic tiles ISO: 13006. Tiles shall be hard, dense, impervious and frost resistant. Water absorption of tiles shall be less than 0.5% and flexural strength (Modulus of Rupture) shall be more than 35 N/Sqmm. (b) The manufacturer's test certificate and individual test certificate for tiles must be submitted for approval by the concerned authority prior to installation.
Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pins, etc as directed (each line of wire to be measured) complete all as specified and as directed in repairs.
Hard core of broken/crushed stone aggregate of gauge n.exc 63 mm deposited, spread and levelled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
Hard core of broken/crushed stone aggregate obtained from demolish materials deposited, spread and levelled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
Precast cement concrete block masonry with solid blocks ,exc 10 cm in width ( using precast cement concrete 1:2:4 type B1) and setting in mortar1:4 complete all as specified and directed in repairs.
Reinforced concrete pipes, class NP2 200mm bore laid and jointed complete with collars in repairs.
Reinforced concrete pipes, class NP2 150mm bore laid and jointed complete with collars in repairs.
A.GOVINDARAJ
T C KARUNANITHI
NAVEEN ENTERPRISES
eurekaenterprises
KUMAR AGENCIES
Neptune Engineers and Builders
DANDU CONSTRUCTIONS
Ravees Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .