| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.5 LAccepted-AOC | ₹16.5 L Quoted ₹16.8 L | L1 | Accepted-AOC LOWEST |
| 2 | L2₹21.3 L+₹4.6 L (27.2%)Rejected-Finance 227 NEW GANESH VIHAR ADARSH MILL ROAD GHOSIPURA LASHKAR GWALIOR 474012 M P | GWALIOR | MADHYA PRADESH | 474012 | ₹21.3 L+₹4.6 L (27.2%) | L2 | Rejected-Finance NOT LOWEST |
| 3 | L3₹22.5 L+₹5.7 L (34.1%)Rejected-Finance | ₹22.5 L+₹5.7 L (34.1%) | L3 | Rejected-Finance NOT LOWEST |
| 4 | L4₹25.1 L+₹8.3 L (49.6%)Rejected-Finance 24 824 GOVERDHAN COLONY MAIN BHIND ROAD GOLE KA MANDIR | ₹25.1 L+₹8.3 L (49.6%) | L4 | Rejected-Finance NOT LOWEST |
| 5 | L5₹25.5 L+₹8.7 L (52.0%)Rejected-Finance | ₹25.5 L+₹8.7 L (52.0%) | L5 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹38,900
Closing Date
6 Jan 2021, 6:00 pmClosed
GE (AF) ADM AREA GWALIOR
AF Station Gwalior
REPAIR REPLACEMENT OF EARTHING LIGHTENING CONDUCTORS AND CONNECTED WORKS AT AF STATION GWALIOR
2020_MES_402881_1
8985/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
AF Station Gwalior
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE AF ADM AREA GWALIOR
₹38,900
Yes
31 Mar 2021
16 Dec 2020
8 Jan 2021
16 Dec 2020
6 Jan 2021
30 Dec 2020
16 Dec 2020 - 25 Dec 2020
Amount
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level), connected to GI wire 4 mm dia main earthing lead by means of galvanized bolts, nuts and washers all as shown in electrical plate no 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board etc with & including all necessary excavation and earth work, adequate quantity of charcoal dust and common salt alround earth plate, PCC 1:3:6 type C-1 using 20mm graded black trap/granite/Basalt stone aggregate for earth pit with pre cast RCC 1:2:4 type B-1 using 20mm graded black trap/granite/Basalt stone aggregate, 40mm thick cover reinforced with 8mm dia TMT bars 3 Nos both way with 08mm dia round bar handle, GI light grade watering pipe 20 mm dia with funnel and wire mesh, and 15mm dia GI light grade earth lead protection pipe complete all as specified and directed.
NOTE :- (i) The cost of earth lead and its protection pipe upto and including 7.5 m only from the top of earth electrode are deemed to be included under this item and additional earth lead & protection pipe, if any, required at site shall be measured and paid for separately under appropriate item of Schedule `A’. (ii) Any joints in earth lead from earth electrode to test point shall not be allowed / permitted.
Material & labour for extension of earth continuity conductor or main earthing lead, 4mm dia GI wire laid in pipe/fixed on walls or any other position, all as specified & directed.
Supply & fixing, light grade, 15mm dia GI water tubing with all fittings fixed on walls/ poles/ in trenches as in earth lead protection pipe all as specified & directed. Make :TATA / Jindal / TT Swastik.
M&L for earthing complete with galvanised steel earth plate electrode 600mm X 600mm X 6mm thick buried directly in ground vertically earth pit not less than 2.25 meter deep below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI earth strip of size 32x6 mm as earthing lead by means of bolts, nuts and washers all as shown in electrical plate No 3 of MES Scedule part I (2009) with conected to eath test point including necessary excavation and earth work, adequate quantity of charcoal dust and comman salt, PCC (1:3:6) type C-1 chamber and for earth pit with 40x40x6mm mild steel angle iron frame for cover. precast RCC cover 40mm thick (1:2:4) type B1 using 20 mm graded stone aggregate reinforced with 8 mm dia round bars both ways with MS handle 8 mm dia. PGI funnel and wire mesh 20 mm dia GI pipe medium grade for watering and 40mm dia medium earth lead protection pipe complete all as specified and directed. Note: GI earth strip and protection pipe upto and including 7.5m is deemed included in unit rate quoted by contractor.
S&F earth continuity conductor or main earthing lead 32x 6 mm GI strip laid in pipe / fixed to poles or any other indicated situation including jointing using by GI nuts, bolts and washer in addition to welding complete all as shwon in drawings, & all as specified and directed .
S&F in repair arresters, expulsion type complete with all fittings, transmission class, discharge capacity 65 KA, suitable for 11000 Volts complete all as specified and directed. Make: BHEL, GE Power, Schneider
Taking down carefully existing unserviceable aluminum point wiring of any description & in any position with and including pvc/steel conduit all fitting, accessories & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings call bell, lamp holders etc and making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as directed. NOTE: Old fittings/fixtures/accessories like switch, sockets, lamp holders, regulators etc found in serviceable condition shall be removed carefully for reuse in the work and shall be paid for separately under appropriate item of Schedule `A’.
Material and labour for point wiring for one light point or one fan point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable FR, 1100 volts grade in and including surface PVC conduit (Medium grade) of suitable size not less then 20 mm dia all as directed with using new sunken type pressed steel box/terminal boxes of suitable size, 2mm thick duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings wiring accessories with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable FR as in earth wire connected to common earth dolly complete all as specified.
NOTE : (i) The portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using PVC rawl plugs and provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick laminated sheet fixed with suitable GI screws and cup washers) (ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of BOQ . (Make of Cable/wire:- : Havells /Finolex/Polycab/Plaza, Make of PVC Conduit:-Finolex/Kilinga Make of Laminated Sheet:-Hylam/National/Anchor)
All as per item No 08 here-in-before but point wiring for 5 pin switch socket outlet, 5 Amps on independent board.
All as per item No 08 here-in-before but point wiring for one 5 pin socket outlet, 5/6 Amps on same board with other switch.
All as per item No 08 here-in-before but point wiring for one six pin socket outlet, 15/5 Amps (independent board) controlled by one switch with using 2.5 Sqmm (nominal area) stranded copper conductor
M&L for point wiring for one light point or one fan point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable FR, 1100 volts grade in existing conduit of any description all as directed with using old existing sunken type pressed steel box/cast iron switch boards/terminal boxes for mounting fittingsaccessories and wiring to be terminated in existing sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core FR. PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete incl taking out old u/s wring from conduit all as specified and directed
NOTE :- (i) The quoted rates shall be deemed to be inclusive for provision of covering existing sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick laminated sheet fixed with suitable GI screws and cup washers) (ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of BOQ (Make of Cable/wire:- : Havells /Finolex/Polycab Make of Laminated Sheet:-Hylam/National/Anchor)
All as per item no 12 hereinbefore but point wring two way switch.
All as per item No 12 hereinbefore but point wiring for one bell/buzzer point controlled by one push button on the same board with other switches or independent.
All as per item No 12 hereinbefore but point wiring for 5 pin switch socket outlet, 5/6 Amps on independent board.
All as per item No 12 here-in-before but point wiring for one six pin socket outlet, 15/5 Amps (independent) controlled by one switch with using 2.5 Sqmm (nominal area) stranded copper conductor.
Material and labour for point wiring for one light point or one fan point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor cable FR, single core, PVC insulated & unsheathed cable, 1100 volts grade in and including concealed PVC conduit (Medium grade) of suitable size not less then 20mm dia all as directed with using new sunken type pressed steel box/terminal boxes of suitable size, 2mm thick duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/junction boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor cable FR single core. PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed.
NOTE : (i) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing colour of surface. The portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using PVC rawl plugs and provision of 8covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick laminated sheet fixed with suitable GI screws and cup washers) (ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of BOQ (Make of Cable/wire:- : Havells /Finolex/Polycab Make of PVC Conduit:-Finolex/Ess Ess Kay Engineering, Make of Laminated Sheet:-/Hylam/National)
All as per item No 17 hereinbefore but point wiring for one bell/buzzer point controlled by one push button on the same board with other switches or independent.
All as per item No 17 hereinbefore but point wiring for 5 pin switch socket outlet combination, 5/6 Amps on independent board.
All as per item No 17 hereinbefore but point wiring for one 5 pin socket outlet, on same board .
All as per item no 17 hereinbefore but point wring two way switch.
All as per item No 17 hereinbefore but point wiring for one six pin socket outlet, 15/5 Amps (independent board) controlled by one switch with using 2.5 Sqmm (nominal area) stranded copper conductor.
S&F switch flush type single pole one way 5 Amps, 240 volts, white ivory finish complete all as specified and directed. (Make :- Anchor(Panta)/ Cona/ Leader)
S&F in repair switch flush type single pole one way 5 Amps, 240 volts, white ivory finish complete all as specified and directed. (Make :- Anchor(Panta)/ Cona/ Leader)
M & L for switch flush type single pole two way 5 Amps, 240 volts, white ivory finish complete all as specified. (Make :-Anchor(Panta) , Cona , Leader )
M&L for socket outlet 2 in 1, 5 pin, 6 Amps flush type white ivory finish complete all as specified. (Make :- Anchor(Panta) , Cona , Leader)
S&F for switch socket combination multi purpose, 5 Pin 6 amps, flush typeWith Indicator complete all as specified and directed.Make:-Cat part No 2216 of cona or equivalent of Leader/ Anchor(Panta).
S&F for switch socket combination multi purpose, 6 Pin 6/16 amps, flush typeWith Indicator complete all as specified and directed. Make:-Cat part No 2711 of cona or equivalent of Leader/ Anchor(Panta).
M&L for ceiling rose surface Bakelite three terminal, 18 x 50 mm complete all as specified. (Make :- Anchor(Panta) , Cona , Leader)
M&L for lamp holder insulated body with back plate for batten fitting complete all as specified. (Make :- Anchor(Panta) , Cona , Leader)
S&F switch bell push, flush type, 5 Amps, single pole, one way , 230 volts AC circuit white ivory finish complete all as specified. (Make : Anchor(Panta)/Cona/Leader)
S&F for bell Ding Dong ,AC 230 V.single pole.Complete all as specified. (Make:-Cat part No Grand Stereo 3421 of cona or equivalent of Leader/ Anchor(Panta)
S&F for step type electronic fan regulator single phase ,230 volt, 100/120 watt . Complete all as specified. (Size of PT switch ) Make:-Cat part No 3211 of cona or equivalent of Leader/ Anchor(Panta).
Supply and laying or fixing or passing through pipe, 1100 Volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed, twin core, 4 Sqmm nominal cross section, stranded aluminium conductor as in service connection including suspension wire as required complete all as specified and directed.
Supply and laying or fixing or passing through pipe, 1100 Volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed, twin core, 6 Sqmm nominal cross section, stranded aluminium conductor as in service connection including suspension wire as required complete all as specified and directed.
Supply and laying or fixing or passing through pipe, 1100 Volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed, twin core, 10 Sqmm nominal cross section, stranded aluminium conductor as in service connection including suspension wire as required complete all as specified and directed.
Supply and fixing in replacement 1100 Volts grade, heavy duty PVC insulated copper conductor of size 1.50 Sqmm complete all as specified and directed. Make of Cable/wire:- : Havells /Finolex/Polycab
Supply and fixing in replacement 1100 Volts grade, heavy duty PVC insulated copper conductor of size 2.50 Sqmm complete all as specified and directed. Make of Cable/wire:- : Havells /Finolex/Polycab
Supply and fixing in replacement 1100 Volts grade, heavy duty PVC insulated copper conductor of size 4.0 Sqmm complete all as specified and directed. Make of Cable/wire:- : Havells /Finolex/Polycab
S&F flexible wire of size 23/.0076 twin twister complete all as specified and directed. Make of Cable/wire:- : Havells /Finolex/Polycab
Dismaintling & Taking out MCB DBs any size , any type and capacity and remove materials from site of works complete all as specified and directed.
S&F for sheet metal enclosure Double door for DB’s 8 way 240 volts with 200 Amps rated bus bar for single phase and neutral supply complete fixed properly on in concealed position and to connect their incoming/outgoing electric connections by means of suitable sizes of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB’s of cables/wires. Complete all as specified. (Make;ABB,Schneider,Legrand)
Dismaintling & Taking out MCBs and isolator any size , any type and capacity and remove materials from site of works complete all as directed.
S&F for MCB single pole 6 to 32 Amps, "C" Curve ,240 Volts complete all as specified (Make:Legrand/ABB/Schneider )
S&F for MCB Single pole and neutral 32 Amps 10 KA, 'C' series, 240 Volts complete all as specified. (Make:Legrand/ABB/Schneider )
M&L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable FR of size 10.0 Sqmm of voltage rating upto and including 1100 Volts grade in existing steel / PVC conduit, along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 10 Sqmm as earth continuity conductor cable FR all as specified and directed.(NOTE : Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.) incl taking out existing sub main wiring with any type of conduit.
All as per item No 46 as above but 6 Sqmm and 6 Sqmm earth wire
All as per item No 46 as above but 4 Sqmm and 4 Sqmm earth wire
All as per item No 46 as above but 2.5 Sqmm and 2.5 Sqmm earth wire
M&L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable FR of size 10.0 Sqmm of voltage rating upto and including 1100 Volts grade in and including concealed PVC conduit, med grade of size not less then 25 mm bore along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 10 Sqmm as earth continuity conductor cable FR all as specified and directed including taking down old submain wiring with any type of conduit. Complete all as specified. (NOTE : Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.) incl taking out old sub main wiring with any type of conduit.
All as per item No 50 hereinbefore but 6 Sqmm and 6 Sqmm earth wire with PVC conduit 20mm dia med grade
All as per item No 50 hereinbefore but 4 Sqmm and 4 Sqmm earth wire with PVC conduit 20mm dia med grade
All as per item No 50 hereinbefore but 2.5 Sqmm and 2.5 Sqmm earth wire with PVC conduit 20mm dia med grade
M&L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable FR of size 10.0 Sqmm of voltage rating upto and including 1100 Volts drawn in and including surface PVC conduit med grade of dia not less than 25mm with standard accessories, along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor cable FR of size 10 Sqmm as earth continuity conductor all as specified and directed including taking down old submain wiring with any type of conduit.(NOTE : Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.) incl taking out existing sub main wiring with any type of conduit
All as per item No 54 hereinbefore but 6 Sqmm and 6 sqmm earth wire and 20mm pvc conduit
All as per item No 54 hereinbefore but 4 Sqmm and 4 sqmm earth wire and 20mm pvc conduit
S&F in replacement single phase electronic energy meter in polycarbonate sheet, steel body with counter display in class 1.0, 50 Hz, 240 V, AC, single phase, ISI marked, capacity 10 Amp to 60 Amp complete all as specified and directed. Make: L&T Cat Part No. WM 101 BC 7 DLO or equivalent in HPL/ Secure/Havells
S&F in replacement 34W LED recess softline luminaire suitable for armstrong/grid ceiling with high brightness LEDs and PMMA extruded diffuser giving glare free light and good aesthetic appeal. Fixture size 595x595x70mm complete with LED tube and all accessories specified. (Make : Havells cat part No PLUTONEO2X2PLR34WLED840S/Surya Cat No- SLEFP36R 22/ CG Cat Part No -LCTLSN36- CDL.)
S&F in replacement LED lamp pin type, 18 Watt, 4 Pin, single phase, 230 Volts, ultra bright with very high efficacy, suited for installation in existing 2G11 lamp holders complete all as specified and directed. Make: Havell's cat Part No. PHOTONULTRAPLL419TL18WLED865SPC/ Surya Cat Part No. SLE 18W PLL/ CG Cat Part No LPLLA-18-CDL
Supply & Fixing in replacement shelter PRO round LED down lighter high lumen package for indoor application, surface mounted LED in engineering plastic housing with clear prismatic diffuser 15 Watt LED complete with lamp and all accessories prewired and including connecting up with twin core twisted flexible copper coductor cable with suitable size upto the ceiling rose complete all as specified and directed. Make: C&S Cat Part No. CG80B 15W LED/ Surya Cat Part No. SLEDLR 15W SHELTER PRO XX/ Havells Cat Part No. RISEDLR 15WV LED 830S.
S&F in replacement PVC exhaust ventilitating fan, 230/ 300 mm sweep including making necessary connection and provision of wire from ceiling rose to fan complete all as specified and directed. Make: Bajaj/ Havells/ CG
Disconnecting of GI earthing strips/ earth wire leads of any size, any description and in any position from test point carefully and testing the earth resistance of any type of earthing with the help of earth tester of suitable capacity, making/ numbering of earthing and recording Ohm value in the resister and at site on wall near test point/ Earth Pit with paint as per performa approved by Engineer-in-Charge & reconnecting of GI earthing strip/ wire lead after test on original position complete all as specified and directed. Note:- (a) The contractor will arrrange earth tester, all T&P & accessories for recording the reading. (b) The contractor shall arrange for watering of the earth pit through watering pipe in the earthing to improve the resistance. The common salt minimum 10 Kg with potassium nitrate (KNO3)-02 Kg for each earthing pit shall be mixed with water at site and filled/ dropped in earthing through watering pipe as per site condition and as directed. The water for this purpose shall be made available by the Department at the nearest source available and contractor shall make their own arrangement from drawing water from the source.
(c) The records of resistance value of each earthing alongwith date of testing shall be maintained as per format approved by Engineer-in-Charge. (d) Testing of the earthing shall be carried out periodically as per site requirement and unit rates quoted by the contractor shall be deemed to include for all provisions for one time testing of the earthing.
M/s KKPARASHAR
m/s varsha traders
anand enterprises
UNIVERSAL AGENCY
SWAMI CONSTRUCTION
m/s anil traders
M/S Rakesh Verma
M/s. Ravi and brothers
lodhi builders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .