Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.8 LAccepted-AOC 145H 2G AQAMA MODEL APARTMENT LUKERGANJ PRAYAGRAJ UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211001 | L1 | Accepted-AOC AOC Awarded | |
| 2 | L2₹44.5 L+₹98,072 (2.26%)Rejected-Finance | L2 | Rejected-Finance Other than lowest quoted tenderer | |
| 3 | L3₹44.6 L+₹1.1 L (2.61%)Rejected-Finance | L3 | Rejected-Finance Other than lowest quoted tenderer | |
| 4 | L4₹47.9 L+₹4.4 L (10.2%)Rejected-Finance | L4 | Rejected-Finance Other than lowest quoted tenderer | |
| 5 | Rejected-Technical | - | Rejected-Technical Requisite document not uploaded |
Tender Value
Refer Docs
EMD Value
₹93,000
Closing Date
30 Apr 2022, 6:55 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST ALLAHABAD
GE WEST ALLAHABAD NEW CANTT ALLAHABAD
PROVN OF REVENUE, LBW AND MINOR WORKS UNDER AGE BR-I AT NEW CANTT ALLAHABAD
2022_MES_512723_2
8541/E8
Open Tender
Civil Works
Item Rate
180 days
NEW CANTT ALLAHABAD
Please refer tender documents
7 documents required · 7 mandatory
₹500
GE WEST ALLAHABAD
₹93,000
Yes
30 May 2022
9 Apr 2022
2 May 2022
9 Apr 2022
30 Apr 2022
16 Apr 2022
60 days
Amount
Demolition of brick work built in cement mortar of any description including all quions arches, pillars, etc complete all as specified and directed.
Taking down cement plaster on brick or stone walls incl wall tiles etc. with raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed
M & L for brickwork with sub class 'B' bricks (old size), straight or curved on plan exc 6 m mean radius, built in CM 1:6 complete all as specified and directed.
M & L for half brick work with sub class 'B' bricks (old size) straight or curved on any radius built in CM 1:4 complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces complete all as specified and directed.
M&L for rendering 10mm thick in CM 1:3 on ceiling surfaces of RCC or brick complete all as specified and directed.
Preparation of newly plaster surface of wall and applying two coats of oil bound distemper over a coat of 1mm thick wall care putty complete all as specified and directed.
Preparation of newly plaster surface of wall and applying two coats of cement base paint including one coat of primer complete all as specified and directed.
Preparation of newly plaster surface of ceiling and applying two coats of white wash complete all as specified and directed.
Dismantling of floor hearth or wall tling including cement mortar bedding (but not backing), removing servicesable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for 25 mm thick plain cement concrete type B0 1:2:4 (12.5mm graded aggregate) as in levelling course of floor and other similar works complete all as specified and directed.
M & L for non skid coloured ceramic floor tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.06 sqm but n exc 0.11 sqm,in floor ,wall etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the surface with 15mm thick screed bed or bedding layer in CM (1:6) complete all as specified and directed.
M & L for non skid joint free coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface with 15mm thick screed bed or bedding layer in CM (1:6) complete all as specified and directed.
All as per Sr Item No 14 here-in-above but used as in dado and skirting over and including 10 mm thick 1:4 CM backing on vertical surface of wall complete all as specified and as directed.
M&L for glazed ceramic coloured wall tiles in vertical surface 450X300X7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering in 1:4 CM complete all as specified and directed.
M&L for 18 mm thick green marble of approved quality of any size set and jointed in grey cement slurry laid over and including 15 mm thick screed bed in CM (1:4) including granite polish to be done by mechanical grinder and moulding of edges including demolation of old stone slab compete all as specified and as directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situations compete all as specified and as directed.
Demolition of cement concrete including floor tiles or stone in any description and any position etc removal from site and complete all as specified and directed.
M&L for 75 mm thick cement concrete 1:3:6 type B2 using 20 mm graded BT stone aggregate in plinth protection finished even and fair including necessary form work and cutting of joints using extra cement etc complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate as in surface channel or surface drain including forming and finishing with extra cement including taking down existing concrete complete all as specified and directed.
M&L RCC type B-1 1:2:4 using 20mm graded stone aggregate as in kitchen shelves etc including demolation of old slab complete all as specified and directed.
M&L form work to suspended slab financial even and smooth as in kitchen shelves etc complete all as specified and directed.
M&L TMT bar 10 mm dia and over, cut to length, bent to shape required ,including cranking ,bending spirally for hooping for columns,hooking end and binding with and including mild steel wire and annealed not less than .9 mm dia or securing with clips complete all as specified and directed.
Demolition of plain cement concrete in any position including tar felt & cement mortar bedding etc from roof or sunken complete all as specified and directed.
Dismantaling of brick tiles or terracing tiles, single layer on roofs complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B-0 (12.5mm graded stone aggregate) as in roof padding,roof kerbs, benching on roof slab and other similar works laid as per slop required finished even and fair complete all as specified and directed.
M&L for 10mm thick plaster in CM 1:3, mixed with liquid water proofing compound @ 200 ml per bag of cement over concrete surface of roof when concrete is green complete all as specified and directed. (Note : WPC to be mesured and paid separately under appropriate item)
Cleaning the dust,durt and any other foreign material from roof surface and applying a coat of bituminous primer @ 0.40 ltr / Sqm uniformily and primer shall be allowed to dry over night as conforming to IS 3384-1986 complete all as specified and directed.
M&L for Laying of 3mm thick APP membrane of (reinforced with non-woven fabric polyester type) (weight not less than 3 kg per sqm) shall be done using butane torch maintaining 100mm side overlap and 150mm end overlap,sealing all overlaps and bonded to the surface by fusing and bonding torchon method complete all as specified and directed. (Note: All water proofing work shall be done as per manufacturer instruction and under supervision of manufacturer technical representative.)
Supply only Liquid water proofing compound (ISI marked) complete all as specified and directed.
M&L for 40mm thick brick tiles laid over and including 15mm thick screed bed in CM 1:4 mixed with polymer based liquid water proofing additive @ 5 % by weight of cement or as per manufacturer's instruction and the joints of tiles shall be filled with CM 1:3 mixed with crude oil as per SSR-2009 (Part-I) on non assesible roof area complete all as specified and directed.
M&L for refixing of 40mm thick brick tiles (Brick Tiles obtained from Sr Item No 27 here-in-above) laid over and including 15mm thick screed bed in CM 1:4 mixed with polymer based liquid water proofing additive @ 5 % by weight of cement or as per manufacturer's instruction and the joints of tiles shall be filled with CM 1:3 mixed with crude oil as per SSR-2009 (Part-I) on non assesible roof area complete all as specified and directed.
M&L for Applying two coats of bitumen based aluminium painting @ 0.15 Kg / sqm on water proofing treatment with preparation of surface as on non assesible area complete all as specified and directed.
M&L for Sunken floor treatment as in following sequence:- (a) The surface of Sunken floor is to be properly cleaning the dust,durt and any other foreign material,fungus moss etc from the surface. (b) M&L for 10mm thick plaster in CM 1:3, mixed with liquid water proofing compound over concrete surface of sunken area when concrete is green. (c) Applying a coat of bituminous primer @ 0.40 ltr / Sqm uniformily and primer shall be allowed to dry over night as conforming to IS 3384-1986. (c) M&L for APP based polymeric water proofing membrane of 3mm thick (reinforced with non-woven fabric polyester type) (weight not less than 3 kg per sqm) shall be done using butane torch maintaining 100mm side overlap and 150mm end overlap,sealing all overlaps including at all junction and corners with bonded to the surface by fusing and bonding torchon method complete all as specified and directed.
M&L for cement concrete 1:5:10,type E2 (40 mm graded aggregate) as in sunken filling and mass concrete works complete all as specified and directed.
M&L for 32 mm bore galvanised steel tubes 'medium grade' as in sunken spout pipe complete all as specified and directed.
M&L for Cutting holes in full brick walls, built in cement mortar for inserting of sunken pipe , holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed.
S&F in repair rotational moulded polyethylene water storage tank of capacity 500 ltr (Cylindrical/vertical with closed top) double layer construction, ISI marked hoisted & fixed in position including dismantling of old tank and removing from site complete all as specified and directed.
S&F in repair ball/ float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed 20mm bore minimum weight 210 gms complete all as specified and directed.
S&F in repairs WC squatting pan “Orissa Pattern” of size 580 x 440mm white with integral foot rest (excluding flushing cistern & flush pipe) including connection to trap and to flush pipes etc and lime concrete bedding complete all as specified in SSR and including 'P' or 'S' trap complete all as specified and directed.
S&F in repair vitreous china wash and basin, white, flat back, size 550 mm x 400 mm fixed on existing bracket, fixing of tap, waste fitting,pipe and union complete all as specified and directed.
S&F in repair PVC flushing cistern 10 ltr capacity valve less syphonic action type low level with and including ball valve float & handle, waste pipe & brackets complete set all as specified and directed.
S & F in repair PVC connection 450 mm long, 15 mm size with brass chromium plated nuts complete all as specified and directed.
Demolition of reinforced concrete Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Taking up or down 15 mm bore GI steel tubing and connections on (walls, ceiling, floors, etc.) including cleaning complete all as specified and as directed
Refixing old 15 mm bore GI steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and as directed
S&F 15 mm bore GI steel tubing "medium grade" with all fittings and fixed to wall, floor and ceiling etc complete all as specified and directed.
Taking up or down 20 mm bore GI steel tubing and connections on (walls, ceiling, floors, etc.) including cleaning complete all as specified and as directed
Refixing old 20 mm bore GI steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and as directed
S&F 20 mm bore GI steel tubing "medium grade" with all fittings and fixed to wall, floor and ceiling etc complete all as specified.
S&F in repair for 15mm bore bib taps chromium plated with crutch or butterfly handle ,screwed down , screwed for iron pipes or brass ferrule complete all as specified and directed.
S&F in repair CP angle stop valve or cock of 15mm bore screwed down for high pressure with crutch or butter fly handle ,screwed both end for iron pipes complete all as specified and directed..
S&F in repairs fancy type Pillar tap 15mm bore, cast copper alloy,with capstan heads, chromium plated, screwed down, high pressure with long shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
S&F in repair 15 mm bore CP fancy stop valve (concealed type) with long shanks and cup fixed with pipes complete all as specified and directed.
S & F in repair for 90 to 125 mm size fancy type chromium plated shower rose with swivel joints,and connecting rod including fixing to steel pipe or union complete all as specified and directed.
S & F in repairs 600 mm long tubular towel rail , brass chromium plated of 20 mm dia complete all as specified and directed.
S&F in repairs Stainless steel grating dome 100 mm dia with or without waste holes as required complete all as specified and directed.
S&F in repair 32 mm bore low density polyethylene (LDPE) pipes of pressure rating 6 kgf/sqcm white in colour fixed in repairs to walls or laid in floors including all fittings such as bend, elbow, tee etc complete all as specified and directed.
S&F in repair 20 mm dia Stainless steel curtain rod of wall thickness not less than 1mm with both side decorative brakets and fixing brakets complete all as specified and directed.
S&F in repair stainless steel sinks with drainage board of 1mm thick in kitchen or laboratory with plug washers and waste pipe including bedding in cement mortar to dwaft wall or including fixing cantilever brackets and connecting union or waste fitting to pipe over all size 915mm x 460mm bowl size 410mm x 330 mm x 160mm complete all as specified and directed.
S&F in repair stainless steel plate rack (utensil rack) of size 900mm X 750mm X 260mm made out of stainless steel 0.63mm thick fixed with brass screw complete all as specified and directed.
M&L for Cutting holes in brick walls in brick walls built in cement mortar or cement lime mortar and stone walls built in lime mortar for purpuse made cutting and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required in full brick wall complete all as specified and directed.
S & F in repairs 110 mm bore PVC (SWR) pipes singles socket in any length with rubber ring joints fixed to walls or floor or in trench complete all as specified and directed.
S & F in repairs 75 mm bore PVC (SWR) pipes singles socket in any length with rubber ring joints fixed to walls or floor or in trences complete all as specified and directed.
S & F in repair 110 mm bore PVC (SWR) bend any radius complete all as specified and directed.
S & F in repair 75 mm bore PVC (SWR) bend any radius complete all as specified and directed.
S & F in repair 110 mm bore PVC (SWR), junction single, (Single T) equal or unequal complete all as specified and directed.
S & F in repair 75 mm bore PVC (SWR), junction single, (Single T) equal or unequal complete all as specified and directed.
S & F in repairs PVC (SWR) floor trap plain or multi with stainless steel grating incl joinig to waste pipe with solvent cement joint dia of outlet 75 mm bore complete all as specified and directed.
Taking down chowkat with shutter (without taking off shutters from the frame) area not exc 1.5 Sqm each and removing from site complete all as specified and directed.
Taking down chowkat with shutter (without taking off shutters from the frame) exc 1.5 Sqm but not exc 4.0 Sqm each and removing from site complete all as specified and directed.
S&F hollow MS steel double / single rebated door frame or any other similar works of approved shape and size complete all as specified and directed.
M&L for 32 mm thick flush shutter,solid core construction with block board core and plywood face panels,commercial type on both sides complete all as specified and directed.
S&F 35 mm thick factory made 2nd class hard wood glazed and skeleton shutters, open repeated and prepared to receive glass, gauze etc (with sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc, size of member of shutter as per specified in SSR part-I section 8,clause 8.24(a) and for door and fixed with chowkats,chemically pressure treated complete all as specified and directed.
S&F Steel windows with side hung shutters including projecting type hinges for glass/wiremess with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S&F steel ventilator with top hung shutter including hinges, steel peg stay etc complete all as specified and directed.
S&F factory made solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawingcomplete all as specified and directed.
S&F 100 mm long mild steel butt hinges, cold rolled, medium weight complete all as specified and directed.
S&F 100 mm long stainless steel butt hinges with steel pin complete all as specified and directed.
S&F for 200mm long anodised aluminium barrel tower bolt of extruded section complete all as specified and directed.
S&F 150mm long anodised aluminium handles, fabricated type complete all as specified and directed.
S&F 300mm long, aluminium alloy, anodised aldrop door bolt including fixing clips of sheet, cast or exturded section and fixing bolts and 16mm dia bolt of sliding bolts of extruded sections complete all as specified and directed.
S&F 150mm long aluminium alloy floor door stopper ,fabricated type complete all as specified and directed.
S&F including fabrication of framed work such as in grills, grating ,hold fast of door and window chowkat etc., with ends of bars shouldered and or riveted or forget into spikes, frames guard bars, barred iron doors, and similar work conforming toFe 290 Gde-E-165 complete all as specified and directed
S&F 3mm thick sheet glass ordinary quality in square n.exc 0.5 Sqm in each pane new door / window shutter complete all as specified and directed.
S&F 3mm thick figured glass pin head type in square n.exc 0.5 Sqm in each pane new ventilator / window shutter complete all as specified and directed.
S & F for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S&F of galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks of galvanised wire staples complete all as specified and directed.
S&F in repair prelaminated MDF type board 18/19 mm thick, interior grade, prelaminated on one side with decorative choice lamination and other side balancing white lamination as in Cupboard Shutter / Cupboard shelves complete all as specified and directed.
S&F 30mm width of flaps continuous (piano) hinges, mild steel, bright finish or electro galvanised complete all as specified and directed.
S&F 100 mm hasp & staple sfety type of stainless steel including bolt to hinges plate and fixed with screws complete all as specified and directed.
S&F 100mm size stainless steel handle cast type polished bright complete all as specified and directed.
M&L preparation of newly steel surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
M&L preparation of new wooden surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of old decorated surface of walls and applying one coat of white wash on wall complete all as specified and directed.
M&L for preparation of old decorated surface of ceiling and applying one coat of white wash on ceiling complete all specified and as directed.
M&L for preparing old decorated surfaces of wall and applying one coat of oil bound distemper white or tinted complete all as specified and directed.
M&L preparation of old decorated surface of wall and applying two coats of apex weather proof external paint over a coat of putty complete all as specified and directed.
M&L preparation of old decorated surface of wall and applying one coat of cement base paint complete all as specified and directed.
Excavation in trenches n exc 1.5 m wide n exc 1.5 m deep in hard soil for foundation etc or for shaft, wells, manholes etc n exc 10 Sqm on plan and not exc 1.5 m in depth and getting out. complete all as specified and directed.
Returning ,filling in including spreading ,levelling watering and well ramming of soft/loose soil in layers n exc 25 cm thick complete all as specified and directed.
Removing excavated soil not exceeding 50 m distance but not exc 100 m distance and depositing where directed at alevel n exc 1.5 metre above the starting point . complete all as specified and directed.
M&L Cement concrete (1:4:8) typeD-2 using 40 mm graded sotne aggregate as in foundation, sub base filling and mass concrete all as specified and directed.
M&L RCC M-25 Design Mix in Foundations,including rafts, footings, foundation beams, plinth beams, bases for column,etc basement slabs, under-reamed piles and mass concrete as all spfd and directed.
M&L RCC M-25 Design Mix in Columns, pillars, piers, posts and struts complete as all spfd and directed.
M&L RCC M-25 Design Mix in Beams, Cantilevers, bressurmmers, Lintels over 1.5 m span complete as all spfd and directed.
Use & waste Formwork to fair finished surfaces of concrete foundations,footings, bases of columns, raft and raft beams, sides and soffit(if any) of foundation and plinth beams, and similar work, vertical or to batter complete as all spfd and directed.
Use & waste Formwork to rough finished square,rectangular or polygonal surfaces of concrete to sides of pillars, posts, struts, piers, columns and stanchions complete as all spfd and directed.
Use & waste of Formwork to rough finished flat surface of concrete to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels,cantilevers, shelves including supports, overhangs, etc, also splays between floors and beam etc complete as all spfd and directed.
All as per Sr Item No 24 here-in-above but 5mm dia and over up to and including 10mm dia in stirrups,spacers and binders complete all as specified and directed.
M&L Rendering 15 mm thick in CM(1:6) on fair faces of brick work or concrete surfaces to be finished even and fair without using extra cement complete as all spfd and directed.
Surface excavation n exc 30 cm deep and above 15 cm avg deep and getting out in soft/loose soil complete all as specified and directed.
M & L for hardcore of broken Stones of gauge n exc 63 mm , deposited spreaded , levelled in layers n exc 15 cm thick watered and rammed to true surface complete all as specified and directed.
M&L 100mm thick PCC type B1, 1:2:4 using 20 mm graded aggregate as in hard standing complete all as specified and directed.
M & L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed.
Surface dressing n.exc 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
Spreading and levelling of soil in layers n exc. 25 cm thick with well ramming including watering as required for filling under floor complete all as specified and directed.
Removing excavated material exc 250 m but n exc 500 m distance and depositing complete all as specified and directed.
M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate as in slabs supported on walls, roof beams etc and the like, complete all as specified and directed.
M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate as in chajjas, shelves etc and the like, complete all as specified and directed.
Use and weste of form work to soffits of suspended slabs such as roof slab etc. n.exc. 200mm thick for fair finished surfaces of concrete complete all as specified and directed.
Use and weste of form work to chullah hood, chajjas, troughs and similar items including edges complete all as specified and directed.
Use and weste of form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed
M&L for treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M&L for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed.
M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed.
M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M&L for treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed.
M&L for brickwork with fly ash bricks (old size), straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 complete all as specified and as directed
M&L for rendering 15mm thick in CM 1:4 on other than fair faces of brick or concrete surface complete all as specified and directed.
M&L for 5 mm thick rendering in CM 1:3 on ceiling surface plaster complete all as specified and as directed.
M&L for water proofing treatment to roof and edges (vertical or tapered) etc. in following sequence:- (a) Properly cleaning and drying the surface (b) Applying a coat of bituminous primer @ 0.40 ltr / Sqm conforming to IS 3384-1986 and primer shall be allowed to dry over night. (c) Laying of 3mm thick APP membrane of (non-woven polyester type) (weight not less than 3 kg per sqm) shall be done using butane torch maintaining 100mm ie overlap and 150mm end overlap,sealing all overlaps and bonded to the surface by fusing and bonding torchon method complete all as specified and directed.(Note: All water proofing work shall be done as per manufacturer instruction and under supervision of manufacturer technical representative.)
M&L for 40mm thick brick tiles laid over 20mm thick screed bed in CM 1:4 mixed with polymer based liquid water proofing additive @ 5 % by weight of cement and the joints of tiles shall be filled with CM 1:3 mixed with crude oil as per SSR-2009 (Part-I) on non assesible roof area complete all as specified and directed.
S&F mild steel framed work as in doors or gates of angle iron,door frame or other section with gusset plate, rails, braces etc complete, drilled for fixing of steel sheeting or other covering etc. to prepared for hanging or sliding with including either hooks and hinges, also fastening and fixing and similar work confirming to Fe 290 Gde-E-165 complete all as specified and as directed.
S&F for steel windows or ventilators, fixed type, with glazing bars complete all as specified and directed.
S&F 20 mm dia Stainless steel curtain rod of wall thickness not less than 1mm with both side decorative brakets and fixing brakets complete all as specified and specified.
S&F for WC squatting pan “Orissa Pattern” of size 580 x 440mm white with integral foot rest (excluding flushing cistern & flush pipe) including connection to trap and to flush pipes etc and lime concrete bedding complete all as specified in SSR and including 'P' or 'S' trap complete all as specified and directed.
S&F for vitreous china wash and basin, white, flat back, size 550 mm x 400 mm fixed on MS bracket including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe, waste fitting,pipe and union complete all as specified and directed.
S&F for PVC flushing cistern 10 ltr capacity valve less syphonic action type low level with and including ball valve float & handle, waste pipe & brackets complete set all as specified and directed.
S&F 15mm bore CP angle stop valve (fancy type) of screwed down for high pressure with crutch or butter fly handle ,screwed both end for iron pipes complete all as specified and directed..
S & F PVC connection 450 mm long, 15 mm size with brass chromium plated nuts complete all as specified.
S&F 15mm bore CP bib taps (fancy type) with crutch or butterfly handle ,screwed down , screwed for iron pipes or brass ferrule complete all as specified and directed.
S&F 15mm bore CP pillar tap (fancy type) cast copper alloy,with capstan heads, chromium plated, screwed down, high pressure with long shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
S & F 110 mm bore PVC (SWR) pipes singles socket in any length with rubber ring joints fixed to wall complete all as specified and directed.
S & F 110 mm outlet dia PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed.
M&L for sand / crused stone dust filling under interloking paver block as in sand cussion bed including leveling complete all as specified and as directed.
M&L for machine pressed precast concrete interlocking glossy paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 grade with grey cement and pigment complete all as specified and directed.
S&F DWC pipe class- SN8 (double wall corrugated pipe of structured wall polyethelene piping systems) of 150 mm internal dia (with coupler and elastometric rubber sealing ring) with non smooth external annular corrugated and smooth internal surfaces (double wall) for non pressure underground sewerage and drainage application confirming to IS: 16098-2013 including all materials, labour, T&P required for proper completion of work complete all as specified and directed.
M&L for granular sub base of class-B type bed for laying of DWC pipe including packing under and haunching against the sides of pipes after they are laid & tested with local sand complete all as specified and directed.
Cutting holes into existing manhole brick wall manhole built in CM, connection new drains making good to pipes and rendering cuttting out existing benching for and forming branch channel ( 1/2 round or 3/4 section) in cement concrete (1:2:4) type B1 smooth finished and reforming benching as required for intenal dia of pipe 150mm complete all as specified and directed.
Taking down carefully point wiring of any type complete for light, fan socket or power point with fittings & fixtures such as ceiling rose, electric fittings, holders, switches, sockets, regulators, wooden batten, surface conduit/casing caping/conceal etc. removing materials including accessories for taking credit and making good disturbed surface to match the existing complete all as specified and directed.
M&L for point wiring with FRLS PVC insulated unsheathed stranded copper conductor cable 1.5 sqmm (nominal area) 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly drawn in and including non metallic PVC rigid, medium grade conceal conduit with all fixing accessories of 20mm dia, using new MS sunk terminal boxes of thickness not less 1.2mm, new 3mm thick laminated sheet cover with brass screw and cup washers with all acessories and making good to disturbed conceal surfaces complete all as specified and directed for the following :-
(a) One light/fan/bell point controlled by one switch
(b) One point for socket outlet 5 amps on independent board but not below the switch board in same vertical plane
(c) One point for socket outlet 5 amps on independent board but below the switch board in same vertical /horizontal plane
(d) One point for socket outlet 5 amp same board
(e) One bell/ buzzer point controlled by one push button on the same board with other switches or independent
(f) One 3 pin 15 Amp socket outlet point controlled by one switch using 2.5 sqmm copper conductor cable with continuous earth wire of 2.5 sqmm copper conductor on independent board.
(g) One 3 pin socket outlet. 15 amps, independent, with cables 4 sq. mm size on independent board
S&F in repair ceiling rose surface type bakelite 65x50mm three terminal complete all as specified and directed.
S&F angle/batten type holder insulated body with back plate suitable for light point complete all as specified and directed.
S&F call bell, ding dong type, AC, 230 V, single pole complete all as specified & directed.
S&F switch piano flush type, 5 amps, 230V AC,single pole, one way complete all as specified & directed.
S&F socket out let 2-in-1, 3 pin, 5 amp flush type complete all as specified & directed.
S&F switch piano flush type 16 amps, 230V AC single pole one way complete all as specified & directed.
S&F socket out let 2-in-1, 3 pin, 5 & 15 amp flush type complete all as specified & directed.
S&F fan regulator, 5 stepped, electronic type, single phase, 80 watt, socket size incl connection complete complete all as specified & directed.
S&F bell push piano flush type 5 amp, SP , 230V AC complete all as specified & directed.
S&F in replacement of sheet metal enclosure single pole and neutral enclosure with a two pin and earth plug and socket along with one MCB, single pole of current rating 20 amps, C series 240 volts AC complete all as specified & directed.
Taking down main switches fuse unit, MCB/Kit kat distribution board with steel enclosure along with MCB’s /Kit kat fuse of any amps/ways including wooden board or from steel board and making good disturbed surfaces complete all as specified & directed.
S&F sheet metal enclosure for MCB's 240 volt 8 way single pole and neutral with 200 amps rated bus bar, double door on wall with and including suitable flat iron clamps duly grouted/ fixed flush in the wall complete all as specified and directed.
S&F MCB single pole, 6 to 32 amps rating, 240 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
S&F MCB single pole & Neutral, 32 amps rating, 240 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
S&F MCB single pole & neutral 40/63 amp, 240 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
Taking down carefully sub main wiring of any nos of wire and size with earth wire on wooden batten/surface conduit/casing caping complete with its all accessories complete all as specified & directed.
M&L for two single core (submain) FRLS PVC insulated cable and one single core green PVC insulated copper conductor earth continuity cable as mentioned below is drawn in and including non metallic, medium duty, rigid PVC conduit not less than 20 mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making good to disturbed surfaces with cement mortar ratio of 1:4 and colour wash complete all as directed. Note :- (I) The cost for cutting, chases required shall deemed to be included in the quoted unit rate. (II) Two run of submain wire, one run of earth wire and one run of PVC conduit shall be measured one RM
(a) 2x4.0 sq. mm + 1x4.0 sq. mm earth wire
(b ) 2x6.0 sq. mm + 1x6.0 sq. mm earth wire
Taking down existing old /worn out tube/CFL/bulk head/sketch light fittings of indoor type fixed on wall of any type/size with its all accessories including lamp complete all as specified & directed
Supply & fixing surface /wall mounted light fitting in CRCA powder coated white housing with pre wired suitable for single T8 LED tube along with supply and fixing one number LED tube in polycarbonate housing of nominal wattage - 18 Watt, Lumen out put - 2100 Lm, Colour Temp - 6500 Kelvin, Size & Length - G13/ T8/ 4 Feet with integral/in built driver, having short circuit and surge protection including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Cat Part No for batten:- REGALBATTENT8UPTO1X18WDSBSWH of make Havells 'or' IGP161LT8-16 of make Crompton 'or' TMC501 P 1xT-LED 22W P3241 of make Philips or its equivalent as approved Cat Part No for Tubelight:- PHOTANULTRA2.01213T8SSTL18WLED865SPC of make Havells 'or' LTT8-20 of make Crompton 'or' MAS LEDtube 1200MM 18W865 T8 I-2100 lm of make Philips or its equivalent as approved
Supply & fixing energy efficient LED light of 10 Watt of length - 02 Feet long having minimum 1150 Lumen output, wide voltage protection range 140-270 Volt AC housed in extruded aluminum housing (enhances safety) with high quality polycarbonate diffuser including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Cat part No: -LUMILINEPLUSSBS10WLED865SPCSS of make Havells 'or' BN 021 LED10S- 6500 PSU GR S1 of make Philips 'or' LDL-10-WW of make Crompton or its equivalent as approved
S&F LED light fitting 10 Watt bulkhead luminaires in high pressure die cast aluminium housing, lumen out put - 700 Lm, colour Temp - 6500 K having Ingress protection - IP 65 fpr dust, water & IK 08 for external impact including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Cat Part No - WT140 LED7S NW PSU S1 PC; Vistaglow of make - Philips 'or' LBHP-10-CDL of make Crompton 'or' LW07-11-XXX-57-XX of make Wipro or its equivalent as approved
Taking down fan, sealing cable end, dismantling blades and removing fan and blades, oiling, greacing and painting of ceiling fans complete with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. incl Hanging and connecting up including provision of cable from ceiling rose or connector to fan as specified and directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
S&F (in replacement) bracket for street light made out of 40 mm bore GI pipe medium grade not less than 1.2 mtr length bent at 120 degree to shape fixed on pole/wall with and including 50x6mm FI clamps = 02 Nos with nut bolts, washers including painting of clamps with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Cutting & Chasing required on on brick wall, exceeding 20 CM girth and making good to disturbed surface with cement mortar 1:3 including facing / finishing where as required to match with existing surfaces to recess the MCB DB/sheet steel enclousure complete all as specified and directed.
Cutting & chasing required not exceeding 10 CM girth for concealed conduit wiring and for GI earth wire including making good to disturbed surface with cement mortar 1:3 and distemper / colour wash to match with existing surfaces including facing / finishing where as required complete in all respect as specified and directed.
M &L for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25M deep below normal ground level) with top edge of the plate not less than 1.5m below normal GL. Connected to galvanized earth lead wire 4mm dia by means of nut, bolt, check nut and washers including necessary excavation and earth work in soft/loose soil, GI protection pipe light grade 15mm bore for protecting the GI wire mesh funnel alternate layer of charcoal dust, and salt PCC pit 1:3:6 type C1 using 20mm graded stone aggregate and 50mm thick RCC 1:2:4 type BO using 20mm graded stone aggregate cover re-inforced with 8 mm dia MS TMT bars 80mm C/C both ways complete all as specified and shown in Electrical plate No.3 SSR part-1 and connected to the earth point and testing complete all as specified and directed.
Supply, installation, testing and commissioning in replacement of outdoor type cubical panel board, doule door suitable for 3 phase, 4 wire, 415V, 50 Hz and CPRI approved manufacturer factory fabricated with CRCA sheet not less than 3 mm thick having modern fabrication process powder coating in approved shade provided with suitable gaskit to make it dust and varmin proof and general constructions conforming to IS : 8623/93. The LT panel shall be front and back openable and duly compartmentalized for each control gears.The panel should have suitable size of aluminium Bus -bar three phase 4 wire system having current carrying capacity 400 Amps of the incomer MCCB. The panel should have the following incoming and out going controlls duly fixed with the panel by means of suitable link plates complete all as specified and as directed by Engineer -in-charge. (PCC platform of suitable size for mounting the LT Panel is deemed to be included in the quoted rate )
(i) Microprocessor based MCCB 4, pole 35 KA with adjustable thermal setting, 415V, 250 Amp - 01 No. (ii) MCCB 4, pole 35 KA with adjustable thermal setting, 415V, 160 Amp - 01 No (iii) MCCB 4, pole 35 KA with adjustable thermal setting, 415V, 125 Amp - 01 No (iv) MCCB 4, pole 25 KA with adjustable thermal setting, 415V, 63 Amp - 01 No (v) Digital Volt meter 0-500 volts (vi) Ammeter 0-500 amps with suitable size of Cts (vii) All connections to be done through suitable size PVC insulated copper cables (viii) LED RYB indicator - 01 Set Make of MCCB : L&T, Havells, Sneider,
M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm complete all as specified and directed.
M&L for brick laid in trenches for cable protection of burnt clay sub class ‘B’ complete laid dry flat complete all as specified and directed.
Supply, laying and testing inreplacement of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and directed.
Supply, laying and testing inreplacement of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core complete all as specified and directed.
Supply and fix steel tubular swaged poles type 410SP-31(9.0 meter long) Swan Neck Type complete with CI base plate and finial and single swan neck, Including foundation and coping complete all as specified and directed.
S&F PVC insulated PVC sheathed stranded copper conductor cable 1.5 Sqmm three core complete all as specified and directed.
S&F rigid PVC conduite 'medium grade' of size 15 mm bore incl fittings, ISI marked, fixing with PCC pole/ steel tubular pole for wiring connection from pole box to light fitting and supporting with 03 Nos GI strip clamp , nut bolt and complete all as specified and directed.
Supply, fixing, connecting, & testing LED streetlight fitting of 70/72 Watt high pressure die cast aluminium housing, with minimum 120 lumen/watt system efficacy, covered potted designed driver of same make as fitting, heat resistant toughened glass with silicon gasket for IP-66 protection, better optics for uniform distribution roadway luminaires complete and fixing on existing bracket of steel tubular pole and connecting the fitting electrically using 3 way 10 amp connector and s&f PVC conduit 20 mm &pvc copper cable 2.5 sqmm 3core from junction pole box to fitting complete all as specified and directed.
S& F Pole box junction three phase of size 297x 250 x 130 mm, made of 2 mm MS sheet factory painted with synthetic enamel paint, and inbuilt locking arrangement, out door type , fix to pole with suitable MS clamp comprising of alluminium busbar 16 Amp 04 Nos fix on epoxy insulated support and MCB 6 Amp 10 kA 240 volt complete all as specified and directed.
M&L for earthing of galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to GI strip 32x6mm as earth lead by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge mesh, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of GI strip protected by 40 mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, and including all excavation and earth work & connecting the earthing to an earthing test point complete all as specified & directed by Engr-in-Charge.
Siddhi Constructionn
M/S PRAGATEE ENTERPRISES
M/S Garg Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .