| 1.00Supply, installation, testing and commissioning of: | ||||||
| 1.01 | 11kV Pilfer resistant metering cubicle for 3phase 4 wire metering system made of MS Sheet steel thickness not less than 2mm duly power coat painted suitable for indoor as well as outdoor as per the site requirement. The cubicle shall be painted through 7-tank process. The External dimensions should be adequate. Panel having two compartments upper Meter compartment and lower CT/PT compartment. Provided with synthetic or semi synthetic gasket firmly glued to the sufrace, Dust, weather and Vermin proof and shall comply degree of protection IP 65 both the chambers having one sided hinged door arrangments. The metering panel shall be provided with two No G.I channels of size 100 x 50 mm on the front and rear sides duly welded and 4 No of lifting hooks. It should be possible to take meter reading manually, through CMRI and computer without opening the LV chamber door. | 1 | Job | 20,000 ₹20,000 | 15,000 ₹15,000 Lowest | 26,000 ₹26,000 |
| 1.02 | Single Phase, Single core, single ratio, Epoxy resin Cast Current Transformers suitable for 11kV, copper wound primary type with rated burden 5VA and accuracy class 0.5 or better and conforming to IS2705 (part-I & II) amended upto date. ISF shall be upto 5The CT ratio shall be 20/5 fori. 2.5 /5 for 25kVA DTii. 5/5 for 63kVA DTiii. 7.5/5 for 100kVA DTiv. 15/5 for 200kVA DTv. 20/5 for 250kVA DTvi. 25/5 for 400kVA DTvii. 50/5 for 630kVA DTviii. 75/5 for 1MVA DT | 1 | Job | 21,000 ₹21,000 Lowest | 22,000 ₹22,000 | 22,000 ₹22,000 |
| 1.03 | 11kV/ 110 V, Three phase epoxy resin cast PT with rated burden 15VA per phase and accuracy class 0.5 or better and conforming to IS:3156 (part-I&II) amended upto date with proper colour coded identification. PTs shall be of uniform insulating and withstand separate source 23kV pf for one minute. | 1 | Job | 29,000 ₹29,000 | 30,000 ₹30,000 | 26,000 ₹26,000 Lowest |
| 1.04 | Bus Bar details:CTs bus bar:- 40x6 mm copper strip or adequate size PTs bus bar: Copper wire 8 SWG or 30x0.6mm copper flat strip to connect PT terminal or adequate size duly insulated by the monoplast tape | 1 | Job | 1,000 ₹1,000 | 500 ₹500 Lowest | 1,000 ₹1,000 |
| 1.05 | PVC Copper wire flexible multi-strand of required size for secondary connections for CT wiring the minimum wire size shall be 4 mm² (RYB) and for PT wiring minimum wire size shall be 2.5 mm² (RYB). | 1 | Job | 1,000 ₹1,000 | 500 ₹500 Lowest | 500 ₹500 Lowest |
| 1.06 | Copper Lugs preferably ring type duly crimped for termination of wires and tapes | 1 | Job | 200 ₹200 Lowest | 500 ₹500 | 400 ₹400 |
| 1.07 | Grounding bus of minimum 40mm copper, 25cm long fixed to the unit in HV chamber. The CTs, PT meter and 11kV Cable sheath shall be grounded to the bus through grounding wire (green) of min size 10mm² | 1 | Job | 2,000 ₹2,000 | 1,500 ₹1,500 | 1,000 ₹1,000 Lowest |
| 1.08 | 3Ph3 Wire HT CT/PT operated Fully static Smart Tri-Vector Energymeters DLMS Compliant Category 'C' with RS 232 port for modem compatibility. 11kV/110V, Ph-Ph (3P,3W) meters for measurement of different electrical parameters including Active Energy (kWh/ MWh), Reactive Energy (kVArh/MVArh), Apparent Energy (kVAh/ MVAh) etc. | 1 | Job | 12,000 ₹12,000 Lowest | 23,000 ₹23,000 | 12,000 ₹12,000 Lowest |
| 1.09 | Independent flexible PVC pipes for CT wiring and PT wiring of appropriate size from HT compartment to meter compartment | 1 | Job | 1,000 ₹1,000 | 1,000 ₹1,000 | 300 ₹300 Lowest |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
8 Sept 2025, 4:00 pmClosed
Executive Engineer ED I
Office of Ex Engineer EDI Basantbagh
Rate Contract for Supply Installation testing and commissioning of kiosk type outdoor HT metering units and LT Prodigy Meter
2025_PDD_284459_1
E NIT NO 025 OF ED-I
Open Tender
Electrical and Maintenance Works
Lump-sum
2 days
Office of Executive Engineer ED I
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
Yes
Executive Engineer ED I
₹20,000
Yes
18 Sept 2025
19 Aug 2025
9 Sept 2025
19 Aug 2025
8 Sept 2025
19 Aug 2025
19 Aug 2025 - 21 Aug 2025
Supply, installation, testing and commissioning of:
11kV Pilfer resistant metering cubicle for 3phase 4 wire metering system made of MS Sheet steel thickness not less than 2mm duly power coat painted suitable for indoor as well as outdoor as per the site requirement. The cubicle shall be painted through 7-tank process. The External dimensions should be adequate. Panel having two compartments upper Meter compartment and lower CT/PT compartment. Provided with synthetic or semi synthetic gasket firmly glued to the sufrace, Dust, weather and Vermin proof and shall comply degree of protection IP 65 both the chambers having one sided hinged door arrangments. The metering panel shall be provided with two No G.I channels of size 100 x 50 mm on the front and rear sides duly welded and 4 No of lifting hooks. It should be possible to take meter reading manually, through CMRI and computer without opening the LV chamber door.
Single Phase, Single core, single ratio, Epoxy resin Cast Current Transformers suitable for 11kV, copper wound primary type with rated burden 5VA and accuracy class 0.5 or better and conforming to IS2705 (part-I & II) amended upto date. ISF shall be upto 5The CT ratio shall be 20/5 fori. 2.5 /5 for 25kVA DTii. 5/5 for 63kVA DTiii. 7.5/5 for 100kVA DTiv. 15/5 for 200kVA DTv. 20/5 for 250kVA DTvi. 25/5 for 400kVA DTvii. 50/5 for 630kVA DTviii. 75/5 for 1MVA DT
11kV/ 110 V, Three phase epoxy resin cast PT with rated burden 15VA per phase and accuracy class 0.5 or better and conforming to IS:3156 (part-I&II) amended upto date with proper colour coded identification. PTs shall be of uniform insulating and withstand separate source 23kV pf for one minute.
Bus Bar details:CTs bus bar:- 40x6 mm copper strip or adequate size PTs bus bar: Copper wire 8 SWG or 30x0.6mm copper flat strip to connect PT terminal or adequate size duly insulated by the monoplast tape
PVC Copper wire flexible multi-strand of required size for secondary connections for CT wiring the minimum wire size shall be 4 mm² (RYB) and for PT wiring minimum wire size shall be 2.5 mm² (RYB).
Copper Lugs preferably ring type duly crimped for termination of wires and tapes
Grounding bus of minimum 40mm copper, 25cm long fixed to the unit in HV chamber. The CTs, PT meter and 11kV Cable sheath shall be grounded to the bus through grounding wire (green) of min size 10mm²
3Ph3 Wire HT CT/PT operated Fully static Smart Tri-Vector Energymeters DLMS Compliant Category 'C' with RS 232 port for modem compatibility. 11kV/110V, Ph-Ph (3P,3W) meters for measurement of different electrical parameters including Active Energy (kWh/ MWh), Reactive Energy (kVArh/MVArh), Apparent Energy (kVAh/ MVAh) etc.
Independent flexible PVC pipes for CT wiring and PT wiring of appropriate size from HT compartment to meter compartment
Pedestal made out of G.I Channel of size 75 x 40 mm or angle iron of size (65 x 65 x 5) mm, duly painted as per site requirement for mounting of metering panel including concrete foundation wherever required including cost of nuts and bolts
3 Core 11 kV Aluminium cable XLPE armoured 35 mm² including cost of clamp for its fixing where ever required.
Cable termination kits suitable for 3 x 35 mm² XLPE Cable (Indoor/Outdoor)
Earthing by way of 40 mm 2.5 mtr long GI Pipe. Job includes , excavation, enhancement material and Main Hole Chamber (500x450x600)mm with frame and cover.
3-Phase 4 wire Trivector Meter (Prodigy) with suitable ring type CT 200 Amp
MCCB-160 Amps, 36 kA, 4pole Ics=100% Icu at 415 (kA rms)
35 mm sq cable (4C) from LT line to meter, 1.1 kV grade Armoued XLPE insulated standard conductur FRLS type
Lugs, ferrules, aluminium thimbles etc
Laiba electrical Suppliers and mechanical work (BID ID -2462915)
M/S QADRI ELECTRICALS (BID ID -2482460)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .