| 1 | L1₹34.2 LAccepted-AOC 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L1 | Accepted-AOC Ok | |
| 2 | L2₹37.2 L+₹2.5 L (7.20%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹40.5 L+₹5.8 L (16.8%)Rejected-Finance 194 IIND FLOOR POCKET 9 SECTOR 24 ROHINI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹40.7 L+₹6.0 L (17.4%)Rejected-Finance 131 SHINGANAPUR ROAD KOLKI KOLKI SATARA MAHARASHTRA 415523 | SATARA | MAHARASHTRA | 415523 | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹44.0 L+₹9.3 L (26.9%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹45.0 L
EMD Value
₹89,900
Closing Date
8 Jun 2022, 6:00 pmClosed
GE E/M BASE HOSPITAL DELHI CANTT
GE E/M BASE HOSPITAL DELHI CANTT-110010
REPAIR/ MAINTENANCE OF UNSERVICEABLE NURSING CALL BELL SYSTEM ALONG WITH DISPLAY PANEL AND REMOTE PUSH SWITCHES BED SIDE LAMPS OT LIGHTS OT LOW GLARE LIGHTS OT SENSOR DOORS AND SCRUB SINK SENSORS AND CONNECTED MISC E/M WORKS AT DIFFERENT WARDS AT
2022_MES_518451_1
GE/BH-06/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE E/M BASE HOSPITAL DELHI CANTT
Class D Category b(i)
7 documents required · 7 mandatory
₹500
GE E/M BASE HOSPITAL DELHI CANTT
₹89,900
Yes
3 Aug 2022
5 May 2022
10 Jun 2022
5 May 2022
8 Jun 2022
20 May 2022
Amount
S & F in repair of Handy and light weight remote control for patients with remote with jacket to fix mount on wall and having Battery type: 12 Volts DC / 23A & Range indoors: 20-30 meters complete all as specified and directed. Make:- Model No. (FBX521) of Make- FORBIX SEMICON or equivalent model of Make- Honeywell/ Hochiki.
S & F in repair of 3-digit receiver display Operates on 12VDC (comes along with 220-110VAC converter) having display size of extra large alphabets complete all as specified and directed. Make:- Model No.FBXDL04 of Make- FORBIX SEMICON or equivalent model of Make- Honeywell/ Hochiki.
S & F in repair of Repeater booster enhances the range of signals furthermore high power repeater provides additional 50-60meters and additional repeater improves the signal to noise ratio (SNR), at some multiple repeaters in series are required complete all as specified and directed. Make : Model No. (FBXCSRPT01C) Signal booster repeater of Make- FORBIX SEMICON or equivalent model of Make- Honeywell/ Hochiki.
S & F in repair Power supply adapter converter of input as 220vac to 12v dc as out put complete all as specified and directed.
S & F in repair alkaline battery 23A 12V as out put complete all as specified and directed.
Supply, Installation Testing & Commissioning in replacement Weatherproof Analogue Addressable Manual Call Point with Integral Short Circuit Isolator. The call point shall have Fast response, Integral short-circuit isolator, Bi-coloured status LED, Non-frangible element fitted as standard (conforms to EN54), Surface mounted, IP67 rated, LPCB approved to EN54 complete all as specified and as directed. Make:- Honeywell/ Siemens/ Panasonic
Supply, Installation Testing & Commissioning in replacement microprocessor based Networkable Analogue Addressable Fire Alarm Control Panel. The Panel shall be compliant with EN54-2, EN54-4 and approved by LPCB. The Fire Alarm Control Panel shall have expandable capacity up to 16 loops. The Panel must have Full colour 800 x 480 LCD with resistive touch screen and automatic backlight dimming. The Panel must also have the capability to take Addressable Intelligent Wired and Wireless Devices on same loop. Each loop shall have a capacity of 127 analogue Addressable devices and 127 Base sounders/Base Sounder Beacons. The panel shall have an event log of minimum 10,000 events @ 1 second resolution, Filterable and Printable. The Panel shall have Three access levels. Panel shall support upto 5000 Cause & Effects entries, with upto 20,000 inputs controlling & 20,000 Controlling outputs across the network. The Panel shall have capability for Peer to Peer networking through RS485 network card. The Panel must have 4 inbuilt programmable sounder circuits, each circuit rated at 2.5A. The Panel must have inbuilt 3 programmable inputs and 5 inbuilt programmable relay outputs. The Panel shall have up to sub-addressable 512 programmable Inputs/Outputs via optional RS485 COMMS serially connected expansion cards. The Panel shall have 240 V AC power supply along with automatic Battery Charger. The Panel shall be fully expandable via common plug in loop driver boards. The user shall have a choice of using the panel with 5.25 Amp or 10.25 Amp power supply unit which is inbuilt in the FACP and should be approved to EN54-4. The Panel shall have configurable via USB port to PC or memory stick. The Panel shall have dedicated RS232 serial port for optional printer approved by LPCB complete all as specified and as directed. Make:- Honeywell/ Siemens/ Panasonic
Supply, installation, commissioning and testing in replacement of LED based ceiling suspended double dome Operation Theater Light with provision only for Camera to be fitted inside the dome as and when required at later stage in compliance with medical device electric standard IEC-60601-2-41, with each dome consisting of minimum 30 LED's and maximum 120 LED's housed in dome with diameter ranging between 500 mm, suspended through a ceiling assembly with spring arm system to provide precise positioning of the OT light as required during surgery complete with UPS including sealed Maintenance free batteries to provide instantaneous backup in case of power failure for 30 minutes complete with all necessary wiring from and hanging arrangements as per manufacturers guidelines with following specifications:-
TECHNICAL SPECIFICATION MAIN DOME SATELLITE DOME Intensity @ 1 Meter (Lux) 1,60,000 + 10% 1,60,000 +10% Adjustable Field diameter (cm) 14-38 14-38 Depth of illumination L1+L2 (cm) > 100 > 100 Color Rendering Index (CRI) (Ra) 95 + 3% 95 + 3% Color temperature (K) 4,500 + 10 % 4,500 + 10 % Intensity control (%) 25-100 25-100 Type of field focusing control By sterllizable handle By sterllizable handle Type of Intensity control By control panel on lamp head By control panel on lamp head
ELECTRICAL & MECHANICAL SPECIFICATIONS Power Supply input voltage (V) 220-230 V Power Consumption (W) < 150 Frequency (Htz) 50/60 Dome Diameter 600-700 mm LED service life (hrs) > 40,000 Make:- Philips/Dr Mach/Hospedia medicare. Note:- The contractor shall submit the details of Make/Model/Specification of the OT light for approval of GE before placing order. The Make and Model of OT light shall fulfill the requirement given here-in-before. In case of any discrepancy/ difference of opinion, the decision of Accepting officer shall be final and binding and nothing extra shall be paid on this account.
S & F in repair of LED 50 inner 8 port circuit complete all as specified and directed.
S & F in repair of LED 50 outer controller circuit complete all as specified and directed.
S & F in repair of LED 50 keypad complete all as specified and directed.
S & F in repair of LED 50 LED's, 6 LED's with lens complete all as specified and directed.
S & F in repair of LED 50 SMPS(switching mode power supply) with lens complete all as specified and directed.
S & F in repair of extra sterilizable handle (yellow/white colour) complete all as specified and directed.
S & F in repair of 650 VA UPS complete all as specified and directed.
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete (fitting such as switches, ceiling roses, pendent, regulator socket etc to be measured separately) and making good disturbed surfaces of wall floor etc complete all as specified and directed.
M&L point wiring for modular switches with 1.5 Sqmm, PVC insulated, unsheathed, multistranded, copper conductor Cable, FRLS, 1100 Volt grade, drawn through and including concealed, rigid non-metallic PVC Conduit of minimum 25mm dia or as per site requirement with all fittings, including cadmium plated screws as per IS, including 1.5 Sqmm size, PVC insulated, unsheathed, copper earth continuity conductor, connected to earth dolly, suitable for One light/fan/bell point controlled by one No, 5 Amp, one way switch/bell push complete all as specified and as directed.
All as per item No. 19 above but one three pin 5 Amps socket out let on independent board.
All as per item No. 19 above but one three pin 5 Amps socket out let on same board.
All as per item No. 19 above but point wiring of copper cable multi stranded 2.5 Sqmm size for 15 Amps socket outlet on independent board with 2.5 Sqmm size of earth conductor complete all as specified and directed.
All as per item No. 19 above but point wiring of copper cable multi stranded 4.00 Sqmm size for AC point wiring with 4.0 Sqmm size of earth conductor complete all as specified and directed.
S&F in replacement modular switch, 1 way, 6 Amp, 1 Module, complete all as specified and as directed.
S&F in replacement modular switch, 1 way, 16 Amp, 1 Module, complete all as specified and as directed.
S&F in replacement modular Socket, 16/6 Amp, 3/5 Pin, combined, 2 module complete all as specified and as directed.
S&F in replacement modular Socket, 6Amp, 2/3 Pin, combined, 2 module complete all as specified and as directed.
S&F in replacement modular cover plate with frame, 3 modules complete all as specified and as directed.
S&F in replacement modular cover plate with frame, 4 modules complete all as specified and as directed.
S&F in replacement modular cover plate with frame, 6 modules complete all as specified and as directed.
S&F in replacement modular cover plate with frame, 8 modules complete all as specified and as directed.
S&F in replacement modular cover plate with frame, 12 modules complete all as specified and as directed.
S&F in replacement modular cover plate with frame, 16 modules complete all as specified and as directed.
S&F in replacement modular metal flush box, 3 modules complete all as specified and as directed.
S&F in replacement modular metal flush box, 4 modules complete all as specified and as directed.
S&F in replacement modular metal flush box, 6 modules complete all as specified and as directed.
S&F in replacement modular metal flush box, 8 modules complete all as specified and as directed.
S&F in replacement module metal flush box, 12 modules complete all as specified and as directed.
S&F in replacement module metal flush box, 16 modules complete all as specified and as directed.
S&F in replacement sub main wiring with 2 runs of 4 Sqmm, single core, PVC insulated & unsheathed cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 20 mm dia, concealed, PVC rigid, non metallic conduit, medium grade, as per IS, with all fittings and one run of 4 Sqmm size PVC insulated copper conductor complete all as specified and as directed. Note:- Two run of cable along with earth conductor including PVC rigid conduit shall be measured as one RM length).
S&F in replacement sub main wiring with 2 runs of 6 Sqmm, single core, PVC insulated & unsheathed cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 25 mm dia, concealed, PVC rigid, non metallic conduit, medium grade, as per IS, with all fittings and one run of 6 Sqmm size PVC insulated copper conductor complete all as specified and as directed. Note:- Two run of cable along with earth conductor including PVC rigid conduit shall be measured as one RM length).
S&F in replacement sub main wiring with 4 runs of 10 Sqmm, single core, PVC insulated & unsheathed cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 32 mm dia, concealed, PVC rigid, non metallic conduit, medium grade, as per IS, with all fittings and one run of 10 Sqmm size PVC insulated copper conductor complete all as specified and as directed. Note:- Four run of cable along with earth conductor including PVC rigid conduit shall be measured as one RM length).
S & F in repair for distribution board double door type, SPN, 12 way, complete including 200 Amps rated bus bar, neutral link, blanking plates etc complete all as specified and directed.
S & F in repair for distribution board double door type, SPN, 4way, complete including 200 Amps rated bus bar, neutral link, blanking plates etc complete all as specified and directed.
S & F in repair for distribution board double door type, SPN, 8 way, complete including 200 Amps rated bus bar, neutral link, blanking plates etc complete all as specified and directed.
S & F in repair MCCB 415 V, 125 Amps, 25 KA, 4 Pole complete all as specified and directed.
S & F in repair MCB TPN, 415 Volts, 63 Amps complete all as specified and directed.
S & F in repair MCB DP, 240 Volts, 40 Amps complete all as specified and directed.
S & F in repair MCB DP, 240 Volts, 63 Amps complete all as specified and directed.
S & F in repair MCB SP, 240 Volts, 16 Amps complete all as specified and directed.
S & F in repair MCB SP, 240 Volts, 32Amps complete all as specified and directed.
S & F in repair MCB SP, 240 Volts, 63 Amps complete all as specified and directed.
M&L Earthing complete with galvanised Iron earth plate eletrode 600x600x6mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of the plate not less than 1.5 metre below normal grond level, surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate with using 4mm dia GI wire as earth wire electrode welded and revetted to earth plate at one end connected to main DBs of Building at another end GI earth wire encased in and including 15mm bore GI light grade pipe through upper end of earth plate upto main DB of bldg, with 20mm bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, MS funnel with wire mesh fixed on water pipe including execvation earth work, Provn of PCC pit in PCC 1:2:4 type B-1 chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type BI duly reinforeced with MS bars 8mm dia @ 150 mm centre to centre, both ways complete with lifting handle all as shown in electrical plate No 3 of SSR of part-I complete all as specified and as directed.
Supplying, installation, testing & Commissioning of recessed Type Full window opal Diffuser Ultra modern slim LED Panel 2x2 with clip support (4 Nos) light of not more than 36W, size 595X595mm (Nominal) suitable for Existing false ceiling with CRCA powder coated White Housing & Isolated Electronic Driver with Output Short-circuit protection, Surge Voltage protection min 3KV, safety & performance test as per IS:15885 Part 2/Sec 13. Total system Lumen not less than 4200 in Cool day Light(5700K), Power factor>0.95, CRI (Ra) >80 with Average life of 50000 Burning hours. Complete with all accessories as required with connections. All above mentioned Specs will be verified through NABL Certified LM79 & LM80 Report before supply of LED Fixture onsite. Make- Havells/ CG/ Polycab
Supply, fixing and connecting in replacement Surface/ Wall Mounted, 20 Watt, integrated LED, 4 feet Fitting, with polycarbonate housing & opal diffuser finish, Integral electronic driver with Output short circuit protection, Surge Voltage Protection of minimum 3 KV and Safety test as per IS15885 Part 2/ Sec 13. Total system Lumen shall be 2000 or above in Cool day Light (6500K), Power factor>0.95, CRI (Ra) >80, System Lumen Efficacy 100 Lm/w, THD(%) < 20, LED with Average life of 50000 Burning hours. Complete with all accessories as required complete all as specified and as directed. Make- Havells/ CG/ Polycab
Supply, fixing and connecting in replacement Surface/Wall Mounted, 9 Watt, integrated LED, 2 feet Fitting with Epoxy powder coated white polycarbonate channel housing. Total system Lumen of 9W LED shall be 800 or above in Cool day Light (6500K), Power factor>0.95, CRI (Ra) >80, System Lumen Efficacy>100 Lm/w, THD(%) < 20, Complete with all accessories as required complete all as specified and as directed. Make- Havells/ CG/ Polycab
S&F in repair load line, distribution board, double door type, TPN, vertical, 8 way, suitable for accomodating upto 125 Amps MCCB with incomming frame three pole, including 250 Amp copper bus bar, neutral link, blanking plates etc complete all as specified and as directed. Make : Legrand Model: 5077 47 or equivalent model of Make mentioned in PS.
M&L for comprehensive maintenance of 02 Nos Motorized door, detailed as under complete all as specified and directed:- (i) Free maintenance and repair of Normal accessories (Spare Parts) for 02 Nos Doors. (ii) Preventive maintenance of all systems on quarterly basis. (iii) Attending all complaints within 24 Hours of complaint intimated by JE-in-Charge. (iv) Field service report shall be maintained and submitted to the JE-in-Charge after expiry of every quarter. Note:- (a) The rates quoted by the contractor shall deemed to be inclusive of T&P etc. (b) Major Spares Parts shall be measured and paid separately under respective item of this Schedule. (c) A penalty of Rs 500.00 per complaint per day shall be imposed on contractor, if the complaint shall not attended within 24 Hours of complaint intimated by JE-in-Charge.
S&F in repair AC, single phase, 230 V, induction motor for motorized door, of carrying capacity 1600 kg, to carry the load with safety sensor limit switches, to ensure end stationing of the gate to safeguard over travelling and over loading of drives, controlling through remote and other connecting accessories and guide bar complete all as specified and as directed.
M&L for comprehensive maintenance of 05 Nos sensor door, detailed as under complete all as specified and directed:- (i) Free maintenance and repair of Normal accessories (Spare Parts) for 05 Nos Doors. (ii) Preventive maintenance of all systems on quarterly basis and upkeep of log book. (iii) Attending all complaints within 24 working hours intimated by JE-in-Charge. (iv) Field service report shall be maintained and submitted to the JE-in-Charge after expiry of every quarter. Note:- (a) The rates quoted by the contractor shall deemed to be inclusive of T&P etc. (b) Major Spares Part shall be measured and paid for separately under respective item of this Schedule as supply only. (c) A penalty of Rs 500.00 per complaint per day shall be imposed on contractor, if the complaint shall not attended within 24 Hours of complaint intimated by JE-in-Charge.
S&F in repair motor for sliding door complete all as specified and as directed.
S&F in repair controller for sliding door complete all as specified and as directed.
S&F in repair power supply for sliding door complete all as specified and as directed.
S&F in repair fotocell for sliding door complete all as specified and as directed.
S&F in repair side pully for sliding door complete all as specified and as directed.
S&F in repair Belt for sliding door complete all as specified and as directed.
S&F in repair foot switch for sliding door complete all as specified and as directed.
S&F in repair hand senser for sliding door complete all as specified and as directed.
S&F in repair door lever handle for sliding door complete all as specified and as directed.
S&F in repair guide roller for sliding door complete all as specified and as directed.
S&F in repair door cover strip for sliding door complete all as specified and as directed.
S&F in repair end stoper for sliding door complete all as specified and as directed.
S&F in repair end stoper plate for sliding door complete all as specified and as directed.
S&F in repair wheel for sliding door complete all as specified and as directed.
S&F in repair wheel chair bkt for sliding door complete all as specified and as directed.
S&F in repair track for sliding door complete all as specified and as directed.
S&F in repair Canopy for track sliding door complete all as specified and as directed.
S&F in repair gasket for sliding door complete all as specified and as directed.
S&F in repair Bedside Light 7 Watt, warm white, separate on/off switches, shade material aluminium with white powder coating, finish colour white, adjustable head for better beam and focus standard complete all as specified and as directed. Make- Philips.
S&F in repair Bedside Light 3 Watt warm white round cylindrical reading light complete all as specified and as directed. Make - Glitz/ Philips/ Bajaj
S&F in repair sheet metal enclosure with socket plug top, single pole and neutral enclosure with a two pin earth plug and socket complete with one MCB of capacity 20 Amps, 240 Volts complete all as specified and directed.
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .