| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.1 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹44.6 L+₹3.3 L (7.99%)Rejected-Finance SAHEBPARA RAOD UPPER BAGDOGRA P O BAGDOGRA DISTRICT DARJEELING WEST BENGAL PIN 734014 | BAGDOGRA | DARJEELING | WEST BENGAL | 734014 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹47.4 L+₹6.1 L (14.7%)Rejected-Finance | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹47.7 L+₹6.4 L (15.4%)Rejected-Finance | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹47.8 L+₹6.4 L (15.6%)Rejected-Finance | L5 | Rejected-Finance Not lowest bidder |
Tender Value
₹42.4 L
EMD Value
₹85,000
Closing Date
27 Sept 2021, 6:00 pmClosed
GE Bengdubi
Bengdubi Military Station, PO-Bengdubi, Dist-Darjeeling, Pin 734424
GE/BENG/38 OF 2021-22 SPECIAL REPAIR TO LT OH LINE TO LT UG CABLE AND PROVN OF TRANSFORMER AT VARIOUS LOCATION UNDER AGE E/M OF GE BENGDUBI MIL STN
2021_MES_473503_1
GE/BENG/38 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bengdubi
MES Enlisted/ Un-enlisted contractor of D and above category b(i)
8 documents required · 8 mandatory
₹500
GE Bengdubi
₹85,000
Yes
7 Oct 2021
7 Sept 2021
29 Sept 2021
7 Sept 2021
27 Sept 2021
21 Sept 2021
9 Sept 2021 - 14 Sept 2021
Amount
SCHEDULE 'A'
Dismantling of ACSR or AAC conductor from service feeder or distributor span, complete all as specified and directed.
Dismantling cross arms of MS channels or angle sections etc, complete all as specified and directed.
Dismantling insulators any type any sizes complete all as specified and directed by Enge-in-Charge.
Supply and laying XLPE insulated, armoured, Heavy duty electric cables with aluminium conductor 1100 volts grade, cross sectional area 6 Sqmm 2 core laid in trenches /Through pipes / ducts or on poles/ wall / floorjointing to O/H conductor, LT panels, main switch with cable size aluminium lugs and testing complete all as specified and directed. (Note ;- Excavation & earthwork shall be measured and paid seperately under respective items of Sch 'A'/BoQ)
Ditto all as per item No. 4.00 here-in-before but 10 Sqmm 2 core
Ditto all as per item No. 4.00 here-in-before but 16 Sqmm 4 core
Ditto all as per item No. 4.00 here-in-before but 25 Sqmm 3.5 core
Ditto all as per item No. 4.00 here-in-before but 50 Sqmm 3.5 core
Ditto all as per item No. 4.00 here-in-before but 70 Sqmm 3.5 core
Ditto all as per item No. 4.00 here-in-before but 95 Sqmm 3.5 core
Ditto all as per item No. 4.00 here-in-before but 120 Sqmm 3.5 core
Ditto all as per item No. 4.00 here-in-before but 150 Sqmm 3.5 core
Excavation in trenches in any type of soil and not exc 1.5 m wide and n.exc 1.5 m in depth for laying of cable and fixing poles, stays etc and getting out complete all as specified and directed.
Returning, filling in approved earth, including spreading, leveling, watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50metre above the starting point complete all as specified and directed.
M&L for sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated (punned) upto 180mm thickness complete all as specified and as directed.
S&F in repair of GI Pipe 50 mm light grade including fittings to poles/laid under road for protection of under ground cable including making good in disturb surfaces and sound coundition complete all as specified and as directed.
S&F in repair of GI Pipe 100 mm light grade including fittings to poles/laid under road for protection of under ground cable including making good in disturb surfaces and sound coundition complete all as specified and as directed.
M&L for Sub Class 'B' Bricks,old size, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion for UG cable protection complete all as specified and directed.
Supply and fixing three core PVC sheathed aluminium conductor of size 1.5 sqmm with 20mm PVC conduit pipe and incl 2 Nos clamps with nut, washer & bolt etc. all as specified and directed.
S & F in repair of junction box made of polycarbonate with IP-65 protection of size of size 230mm x 170mm x 105mm, having terminals for termination of cable with necessary nuts and bolts, poly carbonate cable gland of 2 Nos including 01 No DIN rail for mounting of MC and 01 Nos of MCB SP 10 KA 6 Amps including fixing clamp of FI 50x6mm with necessary nuts and bolts complete all as directed. (Make : Hensel/Syntex)
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts outdoor type Feeder pillar box 'Pedastal type' Confirming to IP 54, CPRI approved, factory fabricated & factroy assembled , waterproof,dust and vermin proof cubical type with locking arrangement , LT Penal made out of suitable size angle iron, channel and fabricated from 3.15 mm thick ( minimum) CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), independently housing for each control switch gear and indicating lamps with & including busbars made of pure copper duly insulated with heat retardent fire proof (HRFR) heat shrinkable sleeves of relevant colours.Bus bar shell be properly supported/mounted on epoxy insulators.All live parts and joints shall be insulated with (HRFR) shrouds, conforming to IS, including provn for cable gland and lugs for incoming and out going cable and connecting suitable earth strips .Suitable openable doors shall be provided of all operational switchgear and MCCBs and detchable cover shall be provided on all other accessories. Grouting the pillar box in ground with & including suitable size foundation & plinth of PCC 1:3:6, type C-1 (using 20 mm grade stone aggregate) complete. Penal shall be manufactured suitable for housing and including the following duly control wiring with multistranded copper condutor FRLS with colour coding incl connection with copper lugs complete for 3 phase 50 Hz electric supply :- (Note : Necessary excavation including returning filling , PCC for grounting the feeder pillar box, connection of existing cable with lugs, cable gland etc. are deemed to be included in the rates.) :- Incoming (a) Copper bus bar - 400 amps rating - 03 Nos. for phases and 200 amp rating - 01 No. for neutral
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts outdoor type Feeder pillar box 'Pedastal type' Confirming to IP 54, CPRI approved, factory fabricated & factroy assembled, waterproof,dust and vermin proof cubical type with locking arrangement, LT Penal made out of suitable size angle iron, channel and fabricated from 3.15 mm thick (minimum) CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), independently housing for each control switch gear and indicating lamps with & including busbars made of pure copper duly insulated with heat retardent fire proof (HRFR) heat shrinkable sleeves of relevant colours. Bus bar shell be properly supported/mounted on epoxy insulators.All live parts and joints shall be insulated with (HRFR) shrouds, conforming to IS, including provn for cable gland and lugs for incoming and out going cable and connecting suitable earth strips .Suitable openable doors shall be provided of all operational switchgear and MCCBs and detchable cover shall be provided on all other accessories. Grouting the pillar box in ground with & including suitable size foundation & plinth of PCC 1:3:6, type C-1 (using 20 mm grade stone aggregate) complete. Penal shall be manufactured suitable for housing and including the following duly control wiring with multistranded copper condutor FRLS with colour coding incl connection with copper lugs complete for 3 phase 50 Hz electric supply :-(Note : Necessary excavation including returning filling , PCC for grounting the feeder pillar box, connection of existing cable with lugs, cable gland etc. are deemed to be included in the rates.) :- Incoming (a) Copper bus bar - 300 amps rating - 03 Nos. for phases and 150 amp rating - 01 No. for neutral
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts outdoor type Bus bar Feeder pillar box 'Pedastal type' Confirming to IP 43, CPRI approved, factory fabricated & factroy assembled, waterproof,dust and vermin proof cubical type with locking arrangement, LT Penal made out of suitable size angle iron, channel and fabricated from 3.15 mm thick (minimum) CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), independently housing for each control switch gear and indicating lamps with & including busbars made of pure copper duly insulated with heat retardent fire proof (HRFR) heat shrinkable sleeves of relevant colours.Bus bar shell be properly supported/mounted on epoxy insulators.All live parts and joints shall be insulated with (HRFR) shrouds, conforming to IS, including provn for cable gland and lugs for incoming and out going cable and connecting suitable earth strips .Suitable openable doors shall be provided of all operational switchgear and MCCBs and detchable cover shall be provided on all other accessories. Grouting the pillar box in ground with & including suitable size foundation & plinth of PCC 1:3:6, type C-1 (using 20 mm grade stone aggregate) complete. Penal shall be manufactured suitable for housing and including the following duly control wiring with multistranded copper condutor FRLS with colour coding incl connection with copper lugs complete for 3 phase 50 Hz electric supply. :- Incoming (a) Copper bus bar - 300 amps rating - 03 Nos. for phases and 150 amp rating - 01 No. for neutral
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts outdoor type Bus bar Feeder pillar box 'Pedastal type' Confirming to IP 43, CPRI approved, factory fabricated & factroy assembled, waterproof,dust and vermin proof cubical type with locking arrangement LT Penal made out of suitable size angle iron, channel and fabricated from 3.15 mm thick (minimum) CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), independently housing for each control switch gear and indicating lamps with & including busbars made of pure copper duly insulated with heat retardent fire proof (HRFR) heat shrinkable sleeves of relevant colours.Bus bar shell be properly supported/mounted on epoxy insulators.All live parts and joints shall be insulated with (HRFR) shrouds, conforming to IS, including provn for cable gland and lugs for incoming and out going cable and connecting suitable earth strips .Suitable openable doors shall be provided of all operational switchgear and MCCBs and detchable cover shall be provided on all other accessories. Grouting the pillar box in ground with & including suitable size foundation & plinth of PCC 1:3:6, type C-1 (using 20 mm grade stone aggregate) complete.Penal shall be manufactured suitable for housing and including the following duly control wiring with multistranded copper condutor FRLS with colour coding incl connection with copper lugs complete for 3 phase 50 Hz electric supply. :- Incoming (a) Copper bus bar - 300 amps rating - 03 Nos. for phases and 150 amp rating - 01 No. for neutral
S&F in repairs busbar chamber in sheet enclosure 100 Amps, 4 Pole, 415V, 50 Hz complete all as spcecified and directed. (Make : Legrand / ABB / L&T/ Schnieder/Havells)
S&F in repairs busbar chamber in sheet enclosure 200 Amps, 4 Pole, 415V, 50 Hz complete all as spcecified and directed. (Make : Legrand / ABB / L&T/ Schnieder/Havells)
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanised iron earth lead wire 4.00 mm dia by means of bolts, nuts, checknuts and washers of galvanised iron or steel, GI earth wire protected by 15mm bore light grade GI pipe and other end connected to earthing test point or main switch board as directed including funnel with watering pipe of 20mm bore light grade GI, wire mesh, charcoal or coke and common salt in alternate layer of 15cm compacted thickness all around the earth electrode PCC (1:3:6) type C-1 earth pit, cast iron cover and frame, including necessary excavation and earth work and refilling of black soil good conductor of earth and necessary testing complete all as specified and directed and shown on electrical plate No 3 of MES Schedule Part-I complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick buried directly in ground ( earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less thab 1.5 Meter below normal ground level connected to GI strip 25x4 by means of bolts, nuts, check nuts and washers of GI and GI tubing 20 mm bore light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1 pre cast RCC (1:2:4) type B1 cover slab 54 x 54 x 5 cm with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing (LG) for watering, charcoal or coal and salt in alternate layers including excavation earth work complete all as specified and directed electrical plate No. 3 of SSR part-I complete all as per directed and specified.
Cutting and trimming of tree branches of any grith all around the LT over head lines upto 2 mtrs from all around the over head lines complete and removing the cut branches from the site to a distance not exc 50 mtr all as specified and directed.
S&F in repairs MCCB 200 Amps 4 Pole, 415 V, Adjustable type with breaking capacity 25 KA ICU including spreader terminals & connected accessories complete as specified and directed. Make : Legrand/ABB/Havells.
S&F in repairs MCCB 250 Amps 4 Pole, 415 V, Adjustable type with breaking capacity 25 KA ICU including spreader terminals & connected accessories complete as specified and directed. Make : Legrand/ABB/Havells.
Supply, lnstall, testing & commissioning of Transformer floor mounted capacity 160 KVA step down, outdoor type 11/0.433 KV, 50 Hz, AC double wound core type, copper wound, oil immersed, air naturally cooled with external cooling tubes transformer delta connection on HV side and star connection on LV side in accordance with vector symbol DyN- 11(Vector group 4) and having tapping as per IS in equal step of 2.5 %, changed by means of off load tap changing arrangement. The voltage regulation shall be as per lS 1180 Pt -1 of 2014 including first fill of transformer oil as per lS -335 and including all fitting /accessories of transformer as specified in SSR Part-1 and lS-1180 Pt -1 of 2014. The transformer should have cable box on LT side and brass brushing on HT side. The limit of Temp rise after continuous full load run as specified in SSR part-l and lS-1180 Pt -1 of 2014 shall be suitably adjusted to suit the maximum ambient temperature prevailing at site all as specified comprising with and including the following specifications:- (i) 01 No Cable box on LT side consisting of 04 Nos porcelain bushing with bushing brass rods and nuts washers and cable glands of suitable size for reception of cable LT 1100 Volt grade XLPE insulated heavy duty including gland joint complete. (ii) HV bushing with arching horn on 11 KV side (iii) Oil conservator with ilter type drain valve and oil level gauge. (iv) Dehydrating breather with irst tilling of Dehydrating Agent . (v) Explosion vent (vi) THERMOMETER Pocket (vii) Two Earthing Terminal on tank body to facilitate fixing 32 x 6 mm Gl strips
Item no 33.00 Contd../- (viii) One No. Thermometer Dail Type vapour pressure type having range 0-120 degreecentigrade g with maximum temperature indicator and re-setting device to maximum temperature including needle of temperature gauge 3 Max reading painted terminal (ix) Rating plate with terminal marking. (x) Oil level guage. (xi) Oil drain filter valve. (xii) Oil filling port on top cover with plug. (xiii) Air release valve/plug. (xiv) 4 Nos plain solid cast steel detachable rollers. (xv) First fill of transformer oil confirming to relevant IS and tested upto 60 KV dielectric strength. (xvi) Inspection cover (xvii) Lifting lugs and jack lifting pad support. (xviii) Bi-directional plan/falnged rullers. (xix) Explosion vent with double diaphragm and sight glass. (xx) Sililca gel breather or with connecting pipe, first fill of dehydrating agent. (xxi) Hand hole of sufficient size to assess the interior of the tank. (xxii) Cover lifting eyes. (xxiii) Rail section and channel embedded in foundation of suitable size in and including PCC 1:3:6 type C-l plate form size 3.0 x 2.5 x1.0 Mtr. including ramp and necessary earth work and excavation and as per manufacturer's instructions or as directed by Engr-in-charge. (xxiv) Oil temp indicator of approved range, including shutt of valve between conservator and main tank.
Item no 33.00 Contd../- (xxv) Winding temp indicator of approved range, including shut of valve between conservator and main tank. (xxvi) Drain valve with threaded adaptor. (xxvii) Filter valve with threaded adaptor. (xxviii) Sample valve. (xxix) Extra bushing for neutral outside the LV side. Transformer details to be embossed :- (a) impendence (b) ohmie loss (c) iron loss (d) voltage regulation (xxxii) The transformer shall have losses within tolerance limit as specified in IS : 1180 NOTE :- (a) Manufacturer test certificate & warranty certificate shall be submitted by the contractor before completion report. (b) Factory test shall be carried out by the the Rep of Accepting Officer at factory permises after manufacture and before despatched at site. Contractor shall arrange for factory visit for Rep of Accepting Officcer for testing at factory. (c) Pre commissioning test shall be carried out by AEI/EI at site before completion of work and energisation of transformer. Contractor shall be provided all necessary testing equipments T&P etc. at site. (d) Any thing missed out above but technically required for proper operation of the Transformer is deemed to be included in the quoted rate.
(Note : The Scope of Work contained in 'Sch of Credit' amounting to Rs. 14,300.00 (refer Tender Srl Page No 33(R)). The Quoted sum shall be arrived at after deducting the amount of “Sch of Credit” from the total amount of the ‘BoQ’
M/S G D CONSTRUCTION
Shree Ram Construction
M/S K M CONSTRUCTION
UNIVERSAL CONSTRUCTION
SHRI S K BHATTACHARJEE
M/S Joy Construction
GURUNG CONSTRUCTION
M/S CONTRACTS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .