Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.1 LAccepted-AOC C 40 BHAGAT SINGH NAGAR BHIND ROAD GWALIOR MP 474005 | NA | NA | 474005 | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹31.8 L+₹96,287.99 (3.12%)Rejected-Finance JAISALMER RAJASTHAN 345001 INDIA UDYAM RJ 18 0001538 | JAISALMER | RAJASTHAN | 345001 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹34.2 L+₹3.3 L (10.8%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹34.7 L+₹3.9 L (12.7%)Rejected-Finance 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L4 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹37 L
EMD Value
₹74,000
Closing Date
30 Sept 2023, 6:00 pmClosed
GE (AF) Jaisalmer
GE (AF) Jaisalmer
SPECIAL REPAIR TO FIRE ALARM SYSTEM AT VARIOUS LOCATIONS AND INSTALLATION OF ANTISTATIC DISCHARGE SYSTEM AT MISSILE TESTING LAB AT AIR FORCE STATION JAISALMER
2023_MES_616239_1
8969/GE/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Jaisalmer
As Per Tender Documents
7 documents required · 7 mandatory
₹500
GE (AF) Jaisalmer
₹74,000
Yes
30 Oct 2023
29 Aug 2023
2 Oct 2023
29 Aug 2023
30 Sept 2023
14 Sept 2023
Amount
Supply, install & testing of analog addressable type self acclimatising multi sensing certified to EN-54 (photo+ heat/smoke) detector with standard mounting base LED Address switch complete with junction box for mounting on surface/ false ceiling complete with necessary fixing accessories including taking down existing complete all as specified and directed.
Supply, install & testing of analog addressable type Rate of rise cum fixed temperature with standard mounting base LED Address switch complete with junction box for mounting on surface/ false ceiling/ below false ceing complete with necessary fixing accessories complete all as specified and directed
Supply, install & testing in repairs of addressable multi crieteria detector combining 4 fire signatures (smoke + heat+co+ IR) with standard mounting base LED Address switch complete with junction box for mounting on surface/ false ceiling/ below false ceing including taking down existing complete with necessary fixing accessories all as specified and directed
Supply, install & testing of analog addressable type Self acclimatising multi sensing (photo+ heat) detector with standard mounting base LED Address switch complete with junction box for mounting on above false ceiling with response indicator on false ceiling with matching screws complete with junction box complete with necessary fixing accessories including taking down existing complete all as specified and directed
Dual LED type response indicator fincluding including taking down complete all as specified and directed
Supply, install & testing of Addressable dual action pull station with address switch and all mounting accessories complete with junction box for mounting on surface including taking down existing complete all as specified and directed
Supply, install & testing of floor warden station complete with fireman's phone jack module with address switch housed in suitable RED enclosure for recessed wall mounting and with latch type or key lock door to the descretion of the consultant with all mounting accessories including taking down existing complete all as specified and directed.
Supply and install & testing of Addressable Control Module with Address switch and all mounting accessories complete with junction box for mounting on surface for sounders and strobes including taking down existing complete all as specified and directed .
Supply and install in repairs Wall mounted sounder with Strobe Lights with 110 cd complete with junction boxes and accessories for mounting on surface including taking down existing complete all as specified and directed.
Supply install and testing of addressable monitor module with address switch and all mounting accessories complete with junction box for mounting on surface including taking down existing complete all as specified and directed.
Supply and install of Addressable Relay Module with Address switch and all mounting accessories complete with pilot relay for Tripping of third party equipment suitable for switching 5A/ 15 A current through the relay contact including taking down existing complete all as specified and directed.
Supply and install of Fault Isolator Module complete with junction box for mounting on surface including taking down existing complete all as specified and directed
Ceiling mounted voice evacuation speaker having power taps up to 2 W and frequency response of 400 to 4000 Hz for voice Evacuation including taking down existing complete all as specified and directed
Supply and install in repairs wall mounted voice evacuation speaker having power taps up to 2 W and frequency response of 400 to 4000 Hz for voice Evacuation ncluding taking down existing complete all as specified and directed
Supply install & testing of Fire fighter telephone instrument including taking down existing complete all as specified and directed
Supply install testing of Floor wise serial outlying annunciator (Repeaters) with 640 Character Backlit LCD display and fixed fun ction keys and soft keys complete all as specified and directed by Eng In Charge. Note: The serial Annunciator shall repeat the signals from the FACP including taking down existing complete all as specified and directed
Supply install and testing in repairs of digital audio amplifier capable of processing one of 8 audio channels and total of 50 W at 70.7 VRMS output along with necessary enclosures. The shall be fully monitored for fault and alarm reportin g. The proposed digital amplifiers shall not be rail mounted/ dependent on fire panel CPU for operation complete as specified and comprising of the following: DAA-5070E-09 Nos, BDA-70V-8 Nos, EQBB-D4-2 Nos, EQDR-D4-2 Nos complete all as specified and directed
PVC insulated , multistranded Zero halogen low smoke fire survival FRLS cable 2 twisted pair 1.5 sqmm copper conductor in conduit confirming to IS 694 and ISI marked cable complete all as specified and directed
PVC insulated FRLS 6 Core 1.5 sqmm multistranded copper conductor cable in conduit confirming to IS 694 and ISI marked cable complete all as specified and directed
Rigid non metallic PVC conduit 25 mm dia inclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers lock nuts saddles pipe hooks as etc required complete all as specified and directed
Analog Addressable Type Manual Call Point having Surface or flush mounting Option fully complaint to EN54 having Rotary Decade Swicthes for Addressing from 01-99 complete with Back Box for Mounting Complete as required conforming to BS5839 Standards and Duly Approved by EN54/LPCB including taking down existing complete all as specified and directed .Make : Honeywell Morley,Siemens ,
Addressable Type Loop Powered Sounder complete with Mounting Base as required conforming to BS5839 Standards and Duly Approved by EN54/LPCB including taking down existing complete all as specified and directed Make : Honeywell Morley , Siemens, Gent
Supply install & testing 2 Loop Micro processor based 1 wire fault tolerant loop, required loop networkable type (each loop accessing 99 detectors and 99 modules ) fire alarm/detection control panel. The panel shall be able to give location of all fire/fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON /OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, Loop cards, 80 character LCD unit to indicate Fire/Fault Signal with addresses. The Panel Shall be Sheet Steel Painted, sealed to IP30. The panel have provision to integrate with PA System . The panel shall have a built in power supply and battery charger along with maintenance free 24 AH, 2 x 12 volt SMF dry batteries capable of running for a minimum of 48 hours with battery charger complete as required including taking down existing and conforming to BS5839 Standards and Duly Approved by EN54/LPCB. GSM Auto dialer intigration required. Make:Honeywell Morley,/ Gent,/Siemens
Battery charger along with maintenance free 24 AH, 2 x 12 volt SMF dry batteries capable of running for a minimum of 48 hours with battery charger suitable for fire alarm control panel microprocessor based including taking down existing complete all as specified and directed
Electric siren system, AC, 415 V, 50 HZ, including necessary foundation and protection from rain water of range 2 Kms installed at roof of Bldg fincluding taking down existing complete all as specified and directed
Supply, fixing and connecting in repairs conventional optical smoke Detectors Complying with and type certified complete with standard base for conventional detector including taking down existing complete all as specified and directed
Supply, installation, commisioning and testing in repairs 02 zone conventional fire alarm control panel with features such as non latching zones, false alarm management, EN 54-2, EN 54-4 LPCB approved including taking down existing complete all as specified and directed.
Supply, installation, commisioning and testing in repairs 04 zone conventional fire alarm control panel with features such as non latching zones, false alarm management, EN 54-2, EN 54-4 LPCB approved including taking down existing complete all as specified and directed.
Supply, fixing and connecting in repairs conventional type manual call point resettable including taking down existing complete all as specified and directed.
Supply, fixing, connecting and testing conventional wall sounder including taking down existing complete all as specified and directed.
Copper strip 20 x 3.15mm with saddles and fixing screw etc for roof conductors and down conductors above ground and connected to existing earthing complete all as specified and directed
Antistatic flooring 3 mm thick vinyl for electrostatic discharge as per manufactures specification complete including scraping down the existing surface to finished lwvel appropriate for laying of the ESD surface complete all as specified and directed.
M/s Ramesh & Company
vinayandsons
SANJOLI CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .