| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.8 LAccepted-AOC CHITRAKALA ART STUDIO GALLERY DREAMLAND JAKHU ROAD SHIMLA 171001 H P | SHIMLA | SHIMLA | HIMACHAL PRADESH | 171001 | ₹4.8 L | 1 | Accepted-AOC L1 |
| 2 | 2₹5.1 LRejected-Finance WARD NO 09 SUJANPUR TIRA DISTT HAMIRPUR 176110 | HAMIRPUR | HIMACHAL PRADESH | 176110 | ₹5.1 L | 2 | Rejected-Finance L2 |
| 3 | 3₹5.2 LRejected-Finance 127 3 LOWER BAZAR SHIMLA HP | SHIMLA | SHIMLA | HIMACHAL PRADESH | ₹5.2 L | 3 | Rejected-Finance L3 |
Tender Value
₹4.9 L
EMD Value
₹4,856
Closing Date
7 Feb 2026, 11:00 amClosed
Sr. Executive Engineer
City Electrical Division, HPSEBL, Shimla
Estimate for R/M of HT/LT Lines at various location CESD, HPSEBL, Boileauganj under the jurisdiction of this division.
2026_HPSEB_127135_1
Tender No27/2025-26
Open Tender
Electrical Works
30 days
Shimla
As per tender document
2 documents required · 2 mandatory
₹590
₹4,856
20 Feb 2026
31 Jan 2026
7 Feb 2026
31 Jan 2026
7 Feb 2026
31 Jan 2026
Estimate for R/M of HT/LT Lines at various locations in (E ) Section Summer Hill CESD, HPSEBL Boileauganj under the jurisdiction of this division
Estimate for R/M of HT/LT Lines at various locations in (E ) Section Vice Regal Lodge CESD, HPSEBL Boileauganj under the jurisdiction of this division
Estimate for R/M of HT/LT Lines at various locations in (E ) Section Kumar House CESD, HPSEBL Boileauganj under the jurisdiction of this division
Note:- Bidder are instructed to fill in the (+/-)% after referring to the irem, rate and quantity in Annexures uploaded online alongwith tender documents
Please Enable Macros to View BoQ information
Chargeable to : 74.510
SCHEDULE OF QUANTITIES AND PRICE
Tender No. HPSEBL/CED/P-Tender No.27 /2025-26 Annexure A
Straightening of STP 8/9 mtr Long and filling of pit and ramming complete the job in all respect complete the job in all respect. Co operative Bank Sangti, middle sangti
Providing, Fixing, Testing & Commissioning of Cable End Termination Kit Heat Shrinkable suitable for 11kV Cable 3x120 mm2. O/D(CPRI) type Tested as per ISI specifications with latest amendments, if any make 3M/Rychem/Denson complete in all respect.at Co operative Bank Sangti
Laying, stringing &sagging of ACSR 6/1./2.59 mm2 conductor along with binding with insulator, nuts and bolts in the STP complete the job in all respect HPU Chowk (180 mtr), Middle sangti (210 mtr)
Laying, stringing &sagging of ACSR 6/1./3.35 mm2 conductor along with binding with insulator, nuts and bolts in the STP complete the job in all respect at HPU Chowk
De-stringing, re-laying, re-stringing &re- sagging of ACSR 6/1./3.35 mm2 conductor along with binding with insulator, nuts and bolts in the STP complete the job in all respect Cooeprative bank Sangti
Relaying, re-sagging of HT 11KV AB cable 120 mm2 alongwith fixing of all the accessories compete in all respect at May Villa and butter mare (70 mtr), Cooperative bank (15 mtr)
Providing, Fixing, Testing & Commissioning of Cable Straight Through Kit Heat Shrinkable suitable for 11kV AB Cable 3x120 mm Sq. (CPRI) O/D type Tested as per ISI specifications with latest amendments, if any make 3M/Rychem/Denson complete in all respect, at May Villa and butter mare
Repair of LT distribution Panel by dismantling of burnt 2 Nos 400A MCCB and providing, fixing, testing & commissioning of 2 Nos MCCB 400 Amp. Capacity, Thermal Magnetic Release (Range 320-400 Amp.) Breaking Capacity 36kA, 4 Pole Fixed Type make Schneider/Siemens/Havels//ABB/ Legrand along with spreader links complete in all respect.
Dismantaling ( removing of cables/end termination kit etc) of old/ burnt 11/0.4KV 630 KVA Transformer complete in all respect. At Cooperative Bank Sangti S/stn
Manual Dragging(50mtr) , Loading, Transportation, (Vehicle should be provided by the HPSEBL), Unloading with the help of hydraulic equipment and manually and Manual Dragging(50mtr) of materials such as burnt/old 11/0.4KV 630 KVA Transformer from Cooperative Bank Sangti to Central Store Maliana complete the job in all respect
Manual Dragging(50mtr) , Loading, Transportation, (Vehicle should be provided by the HPSEBL), Unloading with the help of hydraulic equipment and manually and Manual Dragging(50mtr) of materials such as new 11/0.4KV 630 KVA Transformer from Central Store Maliana to Cooperative Bank Sangti complete the job in all respect
Installation, testing and commissioning of new 11/0.4KV 630 KVA Transformer etc complete in all respect. At Cooperative Bank Sangti S/Stn
Grand Total
Chargeable to : 74.510
SCHEDULE OF QUANTITIES AND PRICE
Tender No. HPSEBL/CED/P-Tender No.27 /2025-26 Annexure B
Excavation work by mechanical/manual means in foundation trenches or drains for Pole Pit for STP 9mtr long
Excavating trenches of required width for pipes,cables etc, including excavation for sockets,depth upto 1.5m,including getting out the excavated materials,returning the soil as required in layers not exceeding 20 cm in depth ,including consolidating each deposited layers by ramming ,watering etc and disposing of surplus excavated soil as directed,within a lead of 50m (Pipes,cablesetc. exceeding 80mm dia but not exceeding 300mm dia) in all respect as per direction of Engineer in Charge.
Providing & fixing of MS Angle of size (50mmx50mmx6mm) length 750 mm compete in all respect
Providing of nuts and bolts(various size with flat and spring washers) in the complete the job in all respect.
Providing Shackle Insulator along with D-iron complete in all respect. At lower tutikandi, Avalodge, AG Colony, Verma Appartment, NCC gate, Hotel Blossom, Kotshera
Providing and fixing of Half Clamp complete the job in all respect.
Providing, Fixing, Testing & Commissioning of Cable Straight Through Kit Heat Shrinkable suitable for 11kV Cable 3x300mm2.. (CPRI) O/D type Tested as per ISI specifications with latest amendments, if any make 3M/Rychem/Denson complete in all respect, at kumar house feeder HPU Chowk (1 Nos), HP Press Feeder ENC Chowk (2 Nos), 11 KV Barrier Feeder near HP Press Gate (1 Nos),
Erection of STP 9 mtr Long , drilling of holes in Pole X-Arm, erection of X-Arms, fixing of Insulators and filling of pit and ramming complete the job in all respect at Avalodge
Straightening of STP 8/9 mtr Long and filling of pit and ramming complete the job in all respect complete the job in all respect at AG Colony, Avalodge, Tutikandi, Lower Tutikandi
Dismantaling of STP 8/9 mtr Long complete the job in all respect.at Avalodge
Re-erection of complete LT Stay set with rod, stay wire, nozzeling & tightening as per the direction of Engineer-in-Charge complete in all respect. Avalodge
De-stringing, re-laying, re-stringing &re- sagging of ACSR 6/1./2.59 mm2 conductor along with binding with insulator, nuts and bolts in the STP complete the job in all respect at Lower Tutikandi, AG Colony, Avalodge, NCC gate, Hotel Blossom, Kotshera
De-stringing, re-laying, re-stringing &re- sagging of ACSR 6/1./4.72 mm2 conductor along with binding with insulator, nuts and bolts in the STP complete the job in all respect at Lower Tutikandi, AG Colony, Avalodge, NCC gate, Hotel Blossom, Kotshera, NCC gate, Hotel Blossom, Kotshera, verma appartment
Lopping/cutting of bushes , tree branches etc in different locations complete in all respect in E section VRL at different location such as tutikandi, HPTCL, Jungli Ground, Janta Store, Avalodge, etc
Providing, Fixing, Testing & Commissioning of Cable End Termination Kit Heat Shrinkable suitable for 11kV Cable 3x300mm2. O/D(CPRI) type Tested as per ISI specifications with latest amendments, if any make 3M/Rychem/Denson complete in all respect.near Chakkar Crossing
Grand Total
Chargeable to : 74.510
SCHEDULE OF QUANTITIES AND PRICE
Tender No. HPSEBL/CED/P-Tender No.27 /2025-26 Annexure C
Excavating trenches of required width for pipes,cables etc, including excavation for sockets,depth upto 1.5m,including getting out the excavated materials,returning the soil as required in layers not exceeding 20 cm in depth ,including consolidating each deposited layers by ramming ,watering etc and disposing of surplus excavated soil as directed,within a lead of 50m (Pipes,cablesetc. exceeding 80mm dia but not exceeding 300mm dia) in all respect as per direction of Engineer in Charge.
Providing, Fixing, Testing & Commissioning of Cable Straight Through Kit Heat Shrinkable suitable for 11kV Cable 3x300mm2.. (CPRI) O/D type Tested as per ISI specifications with latest amendments, if any make 3M/Rychem/Denson complete in all respect, at near Kumar House
Grand Total
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
TENDERDOCUMENT30.pdf
Tender Documents • 0.21 MB
BOQ_187668.xls
BOQ • 0.25 MB
ES27.xls
Additional Documents • 0.05 MB
Download all tender documents and submit your bid